Transmission diamond imaging detector

Many modern synchrotron techniques are trending toward use of high flux beams and/or beams which require enhanced stability and precise understanding of beam position and intensity from the front end of the beamline all the way to the sample. For high flux beams, major challenges include heat load management in optics (including the vacuum windows) and a mechanism of real-time volumetric measurement of beam properties such as flux, position, and morphology. For beam stability in these environments, feedback from such measurements directly to control systems for optical elements or to sample positioning stages would be invaluable. To address these challenges, we are developing diamond-based instrumented vacuum windows with integrated volumetric x-ray intensity, beam profile and beam-position monitoring capabilities. A 50 µm thick single crystal diamond has been lithographically patterned to produce 60 µm pixels, creating a >1kilopixel free-standing transmission imaging detector. This device, coupled with a custom, FPGA-based readout, has been used to image both white and monochromatic x-ray beams and capture the last x-ray photons at the National Synchrotron Light Source (NSLS). This technology will form the basis for the instrumented end-station window of the x-ray footprinting beamline (XFP) at NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the Primary Beam of the Tianlai Cylindrical Antenna Using an Unmanned Aerial Vehicle

The Tianlai Cylinder Pathfinder Array consists of three adjacent cylindrical reflectors fixed on the ground, each 40 m long and 15 m wide, with the cylinder axis oriented along the North–South (N–S) direction. Dual linear polarization feeds are distributed along the focus line, parallel to the cylinder axis. Measurement of the primary beam profile of these cylindrical reflectors is difficult, as they are too large to be placed in an anechoic chamber. While the beam profile along the East–West (E–W) direction can be measured with the transit observations of bright astronomical radio sources, the beam profile along the N–S direction remains very uncertain. Here, we present a preliminary measurement of the beam profile of the Tianlai cylindrical antenna along both the N–S direction and E–W direction in the frequency range of 700–800 MHz, using a calibrator source carried by an unmanned aerial vehicle (UAV) flying in the far field. The beam profile of the Tianlai cylindrical antenna is determined from the analysis of the auto-correlation signals from the cylinder array correlator, taking into account the emitter antenna beam profile, itself measured with a dipole antenna on the ground. The accuracy of the UAV-based determination of the cylinder beam profiles is validated by comparing the results with the one derived from bright astronomical source transits, and with simulated beams.

Li, Jixia [Chinese Academy of Sciences (CAS), Beij↗

Dosimetric effects of rotational output variation and x-ray target degradation on helical tomotherapy plans

In this study, two potential sources of IMRT delivery error have been identified for helical tomotherapy delivery using the HiART system (TomoTherapy, Inc., Madison, WI): Rotational output variation and target degradation. The HiArt system is known to have output variation, typically about {+-}2%, due to the absence of a dose servo system. On the HiArt system, x-ray target replacement is required approximately every 10-12 months due to target degradation. Near the end of target life, the target thins and causes a decrease in the beam energy and a softening of the beam profile at the lateral edges of the beam. The purpose of this study is to evaluate the dosimetric effects of rotational output variation and target degradation by modeling their effects and incorporating them into recalculated treatment plans for three clinical scenarios: Head and neck, partial breast, and prostate. Models were created to emulate both potential sources of error. For output variation, a model was created using a sine function to match the amplitude ({+-}2%), frequency, and phase of the measured rotational output variation data. A second model with a hypothetical variation of {+-}7% was also created to represent the largest variation that could exist without violating the allowable dose window in the delivery system. A measured beam profile near the end of target life was used to create a modified beam profile model for the target degradation. These models were then incorporated into the treatment plan by modifying the leaf opening times in the delivery sinogram. A new beam model was also created to mimic the change in beam energy seen near the end of target life. The plans were then calculated using a research version of the PLANNED ADAPTIVE treatment planning software from TomoTherapy, Inc. Three plans were evaluated in this study: Head and neck, partial breast, and prostate. The D{sub 50} of organs at risk, the D{sub 95} for planning target volumes (PTVs), and the local dose difference were used to evaluate the changes in the modified treatment plans. Dosimetric effects from rotational variation were found to be low (less than 1%) for a typical variation of {+-}2%. Even using a variation of {+-}7%, DVH values and dose distributions were altered by less than 2% for all scenarios. The dosimetric effects of target degradation were found to be slightly more significant. For a model using data taken just before target failure, dosimetric differences of 2%-4% were observed in the recalculated plans when compared to the original plans. The largest effects (up to 4.5%) were observed for PTVs that were located at deeper depths as seen in the prostate plan. Overall, the recalculated plans show that the dosimetric effects of rotational variation and target degradation are on the order of 1%-4% for helical tomotherapy on the HiART system and do not pose a risk for significant deviations from the original treatment plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators

Purpose: Accurate modeling of beam profiles is important for precise treatment planning dosimetry. Calculated beam profiles need to precisely replicate profiles measured during machine commissioning. Finite detector size introduces perturbations into the measured profiles, which, in turn, impact the resulting modeled profiles. The authors investigate a method for extracting the unperturbed beam profiles from those measured during linear accelerator commissioning. Methods: In-plane and cross-plane data were collected for an Elekta Synergy linac at 6 MV using ionization chambers of volume 0.01, 0.04, 0.13, and 0.65 cm{sup 3} and a diode of surface area 0.64 mm{sup 2}. The detectors were orientated with the stem perpendicular to the beam and pointing away from the gantry. Profiles were measured for a 10x10 cm{sup 2} field at depths ranging from 0.8 to 25.0 cm and SSDs from 90 to 110 cm. Shaping parameters of a Gaussian response function were obtained relative to the Edge detector. The Gaussian function was deconvolved from the measured ionization chamber data. The Edge detector profile was taken as an approximation to the true profile, to which deconvolved data were compared. Data were also collected with CC13 and Edge detectors for additional fields and energies on an Elekta Synergy, Varian Trilogy, and Siemens Oncor linear accelerator and response functions obtained. Response functions were compared as a function of depth, SSD, and detector scan direction. Variations in the shaping parameter were introduced and the effect on the resulting deconvolution profiles assessed. Results: Up to 10% setup dependence in the Gaussian shaping parameter occurred, for each detector for a particular plane. This translated to less than a {+-}0.7 mm variation in the 80%-20% penumbral width. For large volume ionization chambers such as the FC65 Farmer type, where the cavity length to diameter ratio is far from 1, the scan direction produced up to a 40% difference in the shaping parameter between in-plane and cross-plane measurements. This is primarily due to the directional difference in penumbral width measured by the FC65 chamber, which can more than double in profiles obtained with the detector stem parallel compared to perpendicular to the scan direction. For the more symmetric CC13 chamber the variation was only 3% between in-plane and cross-plane measurements. Conclusions: The authors have shown that the detector response varies with detector type, depth, SSD, and detector scan direction. In-plane vs cross-plane scanning can require calculation of a direction dependent response function. The effect of a 10% overall variation in the response function, for an ionization chamber, translates to a small deviation in the penumbra from that of the Edge detector measured profile when deconvolved. Due to the uncertainties introduced by deconvolution the Edge detector would be preferable in obtaining an approximation of the true profile, particularly for field sizes where the energy dependence of the diode can be neglected. However, an averaged response function could be utilized to provide a good approximation of the true profile for large ionization chambers and for larger fields for which diode detectors are not recommended.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled Target-Beam-Moderator Optimization for the Second Target Station

This report describes the results for a coupled target-beam-moderator optimization analysis for the Second Target Station (STS) at ORNL's Spallation Neutron Source. This study is a continuation of the optimization analysis for the moderators in the preliminary design of STS performed in 2022. In the 2022 analysis the dimensions of the moderators are parameterized, while the target and the proton beam profile are kept constant. In this analysis the target height and the proton beam profile are added as parameters. This allows to study the coupled effects of changing target, moderator and beam dimensions. Similar to the 2022 analysis, this work is performed with an automated optimization workflow that uses the optimization toolbox DAKOTA, parameterized geometries in CREO and SpaceClaim, the unstructured mesh generation in Attila4MC, and the particle transport code MCNP6.2©. This workflow enables an efficient optimization using high-fidelity geometries. The main conclusions of this analysis are the following: • Coupled beam-target-moderator optimization provides a few additional percent performance gain over stand-alone moderator optimization. • The moderator performance is not very sensitive to the target height (between ≈60 and ≈80 mm) as long as the beam profile is chosen adequately. • The moderator performance is sensitive to the choice of beam spatial standard deviations, even when the footprint is kept constant. • The optimal moderator radius is the same for a beam footprint of 30 cm 2 , 62.5 cm 2 , and 90 cm 2 . Also the slope of the super-gaussian beam profile does not significantly impact the optimal moderator radius. • The optimal parameters and sensitivities are very similar to the 2022 optimization analysis. These results only indicate a a difference in the optimal radius of the cylindrical moderator, however, this has been corrected in the final design moderator optimization. The main purpose of this report is to document the simulations, results and lessons learned. The most impactful results are summarized in. We also note that the target geometry used in this work is not the final design.

43 PARTICLE ACCELERATORS↗

User defined intensity profile laser beam

A high-power laser beam with an arbitrary intensity profile is produced. Such beam has a variety of uses including for laser materials processing such as powder bed fusion additive manufacturing. Several challenges in additive manufacturing are mitigated with the present non-uniform intensity laser profiles. Nonuniform shapes include a set of intensity pixels in a line that could print a wide stripe area instead of just a single line. One example uses the multimode interference pattern from the output of a ribbon fiber which is imaged onto a work piece. The interference pattern is controlled to allow turning on or off of ‘pixels’ along a line which can be used to shape the beam and form the additively manufactured part.

Drachenberg, Derrek R.↗

Study of Muon Monitor Data to Maintain the Quality of the NuMI Neutrino Beam at Fermilab [Poster]

A muon monitor which measures muon beam profile, is a key beam element to maintain the quality of muon neutrino beam. Three arrays of muon monitors located in the downstream of the hadron absorber provide the measurements of the primary beam quality. We studied the response of muon monitors with the proton beam profile changes and focusing horn current variations. The responses of muon monitors have been used to implement Machine Learning (ML) algorithms to monitor the beam quality.

43 PARTICLE ACCELERATORS↗

The extraction of true profiles for TPS commissioning and its impact on IMRT patient-specific QA

The aim of this work is to investigate the clinical impact of detector size effect on patient specific intensity-modulated radiation therapy (IMRT) quality assurance (QA). Two photon beam models, BM6 and BM4, were commissioned using photon beam profiles measured with a 6 mm diameter and a 4 mm diameter ion chambers, respectively. A method was developed to extract the ''true'' cross beam profiles, free of volume averaging effect, using analytic fitting/deconvolution. The method was validated using beam profiles measured with a small (0.8 mm) diode detector for small ({<=}10x10 cm{sup 2}) field sizes. These profiles were used to commission a third beam model (BM08). Planar dose distributions for eight IMRT plans (total of 53 fields) were calculated using the three beam models and measured with a two-dimensional detector array. Analysis using percent dose difference and distance-to-agreement criteria between the calculation and measurement was done to benchmark the performance of each beam model. The average passing rates between calculation and measurement were 93.8%, 98.9%, and 99.4% for BM6, BM4, and BM08, respectively, when 3%/3 mm criteria were used. A gradual increase in passing rates was noticed with the decrease in the size of the detector used to collect commissioning data. When 2%/2 mm criteria were used, the average passing rates increased significantly from 81.6% (BM6) to 92.6% (BM4) and 96.8% (BM08). These results quantify the enhancement of IMRT dose calculation accuracy with the reduction in detector size used for photon beam profiles measurement. Our study indicates that volume averaging effect can significantly affect the results of IMRT patient specific QA. By removing the detector size effect in beam commissioning, excellent passing rates can be achieved with more stringent criteria such as 2%/2 mm. The use of more stringent criteria for IMRT patient specific QA would likely result in higher chances of detecting any dosimetric errors arising from the treatment planning or delivery system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commissioning of a Varian Clinac iX 6 MV photon beam using Monte Carlo simulation

Monte Carlo modelling of a linear accelerator is the first and most important step in Monte Carlo dose calculations in radiotherapy. Monte Carlo is considered today to be the most accurate and detailed calculation method in different fields of medical physics. In this research, we developed a photon beam model for Varian Clinac iX 6 MV equipped with MilleniumMLC120 for dose calculation purposes using BEAMnrc/DOSXYZnrc Monte Carlo system based on the underlying EGSnrc particle transport code. Monte Carlo simulation for this commissioning head LINAC divided in two stages are design head Linac model using BEAMnrc, characterize this model using BEAMDP and analyze the difference between simulation and measurement data using DOSXYZnrc. In the first step, to reduce simulation time, a virtual treatment head LINAC was built in two parts (patient-dependent component and patient-independent component). The incident electron energy varied 6.1 MeV, 6.2 MeV and 6.3 MeV, 6.4 MeV, and 6.6 MeV and the FWHM (full width at half maximum) of source is 1 mm. Phase-space file from the virtual model characterized using BEAMDP. The results of MC calculations using DOSXYZnrc in water phantom are percent depth doses (PDDs) and beam profiles at depths 10 cm were compared with measurements. This process has been completed if the dose difference of measured and calculated relative depth-dose data along the central-axis and dose profile at depths 10 cm is ≤ 5%. The effect of beam width on percentage depth doses and beam profiles was studied. Results of the virtual model were in close agreement with measurements in incident energy electron 6.4 MeV. Our results showed that photon beam width could be tuned using large field beam profile at the depth of maximum dose. The Monte Carlo model developed in this study accurately represents the Varian Clinac iX with millennium MLC 120 leaf and can be used for reliable patient dose calculations. In this commissioning process, the good criteria of dose difference in PDD and dose profiles were achieve using incident electron energy 6.4 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Initial evaluation of a commercial EPID modified to a novel direct-detection configuration for radiotherapy dosimetry

Electronic portal imaging devices (EPIDs) integrated with medical linear accelerators utilize an indirect-detection EPID configuration (ID-EPID). Amorphous silicon ID-EPIDs provide high quality low dose images for verification of radiotherapy treatments but they have limitations as dosimeters. The standard ID-EPID configuration includes a high atomic number phosphor scintillator screen, a 1 mm copper layer, and other nonwater equivalent materials covering the detector. This configuration leads to marked differences in the response of an ID-EPID compared to standard radiotherapy dosimeters such as ion chambers in water. In this study the phosphor and copper were removed from a standard commercial EPID to modify the configuration to a direct-detection EPID (DD-EPID). Using solid water as the buildup and backscatter for the detector, dosimetric measurements were performed on the DD-EPID and compared to standard dose-in-water data for 6 and 18 MV photons. The sensitivity of the DD-EPID was approximately eight times less than the ID-EPID but the signal was sufficient to produce accurate and reproducible beam profile measurements for open beams and an intensity-modulated beam. Due to the lower signal levels it was found necessary to ensure that the dark field correction (no radiation) DD-EPID signal was stable or updated frequently. The linearity of dose response was comparable to the ID-EPID but with a greater under-response at low doses. DD-EPID measurements of field size output factors and beam profiles at the depth of maximum dose (d{sub max}), and tissue-maximum ratios between the depths of 0.5 and 10 cm, were in close agreement with dose in water measurements. At depths beyond d{sub max} the DD-EPID showed a greater change in response to field size than ionisation chamber measurements and the beam penumbrae were broader compared to diode scans. The modified DD-EPID configuration studied here has the potential to improve the performance of EPIDs for dose verification of radiotherapy treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fluctuation of an ion beam extracted from an AC filament driven Bernas-type ion source

Argon ion beam fluctuation from an AC filament driven Bernas-type ion source is observed. The ion beam was measured by an 8 measurement elements beam profile monitor. The amplitude of the beam current fluctuation stayed in the same level from 100 Hz to 1 kHz of the filament heating frequency. The beam current fluctuation frequency measured by the beam profile monitor was equal to the frequency of the AC filament operation. The fluctuation amplitudes of the beam current by AC operation were less than 7% and were in the same level of the DC operation.

43 PARTICLE ACCELERATORS↗

Multiple-type solutions for multipole interface solitons in thermal nonlinear media

We address the existence of multipole interface solitons in one-dimensional thermal nonlinear media with a step in the linear refractive index at the sample center. It is found that there exist two types of solutions for tripole and quadrupole interface solitons. The two types of interface solitons have different profiles, beam widths, mass centers, and stability regions. For a given propagation constant, only one type of interface soliton is proved to be stable, while the other type can also survive over a long distance. In addition, three types of solutions for fifth-order interface solitons are found.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

A High Count Rate Beam Monitor for Thermal Neutrons

Beam monitors are an important diagnostic tool in neutron science facilities. Present beam monitors use either ionization chambers in integration mode, which are slow and have no timing information, or pulse counters which can easily be saturated by high beam intensities. Neutron beam monitors indicate the number of neutrons incident on a scattering sample and allow neutron experimental data to be analyzed even when the source strength varies with time. At high flux neutron scattering facilities, neutron beam monitors with very low efficiency (10-5) are presently selected to keep the counting rate within a feasible range, even when a higher efficiency would improve the counting statistics and yield a better measurement of the incident beam. In this work, we report on a high count rate neutron beam monitor which also offers position sensitivity to provide a beam profile. This beam monitor offers good timing (less than 1 s) in addition to position resolution and will therefore improve the counting statistics at neutron energies up to 10 eV and allow moderator studies. The detector s main characteristics will be presented including its background rate, its count rate capability which is an order of magnitude higher than present counting monitors, and its efficiency for thermal neutrons.

Barnett, Amanda↗

OMEGA polar-drive target designs

Low-adiabat polar-drive (PD) [Skupsky et al., Phys. Plasmas 11, 2763 (2004)] implosion designs for the OMEGA [Boehly et al., Opt. Commun. 133, 495 (1997)] laser are described. These designs for cryogenic deuterium-tritium and warm plastic shells use a temporal laser pulse shape with three pickets followed by a main pulse [Goncharov et al., Phys. Rev. Lett. 104, 165001 (2010)]. The designs are at two different on-target laser intensities, with different in-flight aspect ratios (IFARs). These designs permit studies of implosion energetics and target performance closer to ignition-relevant intensities ({approx}7 Multiplication-Sign 10{sup 14} W/cm{sup 2} at the quarter-critical surface, where nonlocal heat conduction and laser-plasma interactions can play an important role) but at lower values of IFAR {approx} 22 or at lower intensity ({approx}3 Multiplication-Sign 10{sup 14} W/cm{sup 2}) but at a higher IFAR (IFAR {approx} 32, where shell instability can play an important role). PD geometry requires repointing of laser beams to improve shell symmetry. The higher-intensity designs optimize target performance by repointing beams to a lesser extent, compensating for the reduced equatorial drive by increasing the energies of the repointed beams. They also use custom beam profiles that improve equatorial illumination at the expense of irradiation at higher latitudes. These latter designs will be studied when new phase plates for the OMEGA Laser System, corresponding to the custom beam profiles, are obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode

Since its introduction the PinPoint (PTW-Freiburg) micro-ionization chamber has been proposed for relative dosimetry (output factors, depth dose curves, and beam profiles) as well as for determination of absolute dose of small high-energy photon beams. This paper investigates the dosimetric performance of a new design (type 31014) of the PinPoint ion chamber with a central aluminum electrode. The study included characterization of inherent and radiation-induced leakage, ion collection efficiency and polarity effect, relative response of the chamber, measurement of beam profiles, and depth dose curves. The 6 and 15 MV photon beams of a Varian 2100 C/D were considered. At the nominal operating voltage of 400 V the PinPoint type 31014 chamber was found to present a strong field size dependence of the polarity correction factor and an excess of the collected charge, which can lead to an underestimation of the collection efficiency if determined with the conventional ''two-voltage'' method. In comparison to the original PinPoint design (type 31006) the authors found for type 31014 chamber no overresponse to large-area fields if polarity correction is applied. If no correction is taken into consideration, the authors found the chamber's output to be inaccurate for large-area fields (0.5% accuracy limited up to the 12x12 and 20x20 cm{sup 2} field for the 6 and 15 MV beams, respectively), which is a direct consequence of the stem and polarity effects due to the chamber's very small sensitive volume (0.015 cc) and cable irradiation. Beam profiles and depth dose curves measured with type 31014 PinPoint chamber for small and medium size fields were compared to data measured with a 0.125 cc ion chamber and with high-resolution Kodak EDR2 films. Analysis of the penumbra (80%-20% distance) showed that the spatial resolution of type 31014 PinPoint ion chamber approaches (penumbra broadening {<=}0.6 mm) EDR2 film results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRD-04: Development of a Secondary MU Calculation Tool for An Integrated MR-LINAC

Purpose: To develop a fast secondary MU calculation tool for an integrated MR-Linac, an emerging technology for delivering image-guided on-line adaptive therapy. Methods: A software tool was developed to implement a modified Clarkson integration algorithm for point-dose calculation, considering the dosimtric effect of a magnetic field. A research planning system, considering the presence of a perpendicular 1.5 T magnetic field, was used to extract the beam data (e.g., depth doses and beam profiles) required for the MU calculation in homogeneous phantom of 60×60×40 cm3 for a prototype of MR-Linac integrating a 1.5 T MR scanner with 6MV photon beams. These dosimetric data may be replaced with those to be collected during the commissioning measurement of the MR-Linac. Results: The presence of the magnetic field resulted in noticeable changes including (1) shifts in beam profiles for small fields (< 2×2 cm2), and (2) changes in central-axis doses when one of field edges is < 2 cm away from the central axis. For example, the maximum change in central-axis dose was up to 8% for one of the field borders with a distance away from the central axis of <1 cm. These changes are relevant for the MU calculation particularly for IMRT and VMAT, where most of segments are small. These magnetic field affected beam profiles and depth doses were included in the software tool. The MU calculations from the software tool for selective representative plans were found to agree with those from the research planning system within 10%. Conclusion: The presence of a perpendicular magnetic field results in noticeable changes in beam profiles and depth doses for small fields. These changes are included in the secondary MU calc{sup 33}u{sup 3}lation to be used as a redundancy check for an integrated MR-Linac.