Search NASA⌕ Search

SEARCH · Search NASA

Results for “BLADDER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Urinary diversions: a primer of the surgical techniques and imaging findings

Objective: The article attempts to describe the indications, classification, and surgical anatomy of the commonly performed urinary diversion procedures, followed by the imaging protocol and radiological appearances of the normal postoperative anatomy and complications related to these procedures. Contents: Diversion procedures are used to reroute urine after cystectomy and in patients with refractory neurogenic or outlet obstruction of the urinary bladder. Broadly, these can be classified as continent and incontinent diversions. Patients with urinary diversions frequently undergo radiological investigations for the detection of complications. Commonly, a loopogram or pouchogram is performed few weeks after the surgery to look for leak, whereas CT or MRI is used for long-term follow-up. Postoperative complications can be early (within 30 days of the surgery) or delayed and include leaks, collections, strictures, calculi, parastomal hernia, small bowel obstruction, and oncologic recurrence. Conclusion: A variety of urinary diversion procedures are commonly performed and interpretation of the postsurgical anatomy can be overwhelming for the general radiologist. This article provides a basic understanding of the normal anatomy as well as a thorough discussion on the imaging protocol and radiological appearances of the potential complications associated with these procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Impact of Intrafraction Motion in Online-Adaptive Intensity Modulated Proton Therapy for Cervical Cancer

A method was recently developed for online-adaptive intensity modulated proton therapy (IMPT) in patients with cervical cancer. The advantage of this approach, relying on the use of tight margins, is challenged by the intrafraction target motion. The purpose of this study was to evaluate the dosimetric effect of intrafraction motion on the target owing to changes in bladder filling in patients with cervical cancer treated with online-adaptive IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Reported Outcomes in the Acute Phase of the Randomized Hypofractionated Irradiation for Prostate Cancer (HYPRO) Trial

Many patients experience bowel and bladder toxicity during the acute phase of radiation therapy for prostate cancer. Recent literature indicates that hypofractionation (HF) might increase this acute response but little is known on patient-reported outcome during this phase with HF. We evaluated the course of patient-reported acute symptoms during HF versus standard fractionated (SF) radiation therapy within the hypofractionated irradiation for prostate cancer (HYPRO) trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

cTULIP: application of a human-based RNA-seq primary tumor classification tool for cross-species primary tumor classification in canine

The domestic dog, Canis familiaris, is quickly gaining traction as an advantageous model for use in the study of cancer, one of the leading causes of death worldwide. Naturally occurring canine cancers share clinical, histological, and molecular characteristics with the corresponding human diseases. In this study, we take a deep-learning approach to test how similar the gene expression profile of canine glioma and bladder cancer (BLCA) tumors are to the corresponding human tumors. We likewise develop a tool for identifying misclassified or outlier samples in large canine oncological datasets, analogous to that which was developed for human datasets. We test a number of machine learning algorithms and found that a convolutional neural network outperformed logistic regression and random forest approaches. We use a recently developed RNA-seq-based convolutional neural network, TULIP, to test the robustness of a human-data-trained primary tumor classification tool on cross-species primary tumor prediction. Our study ultimately highlights the molecular similarities between canine and human BLCA and glioma tumors, showing that protein-coding one-to-one homologs shared between humans and canines, are sufficient to distinguish between BLCA and gliomas. The results of this study indicate that using protein-coding one-to-one homologs as the features in the input layer of TULIP performs good primary tumor prediction in both humans and canines. Furthermore, our analysis shows that our selected features also contain the majority of features with known clinical relevance in BLCA and gliomas. Our success in using a human-data-trained model for cross-species primary tumor prediction also sheds light on the conservation of oncological pathways in humans and canines, further underscoring the importance of the canine model system in the study of human disease.

60 APPLIED LIFE SCIENCES↗

Liquid propulsion systems

Bladder and expulsion devices for spacecraft liquid propulsion systems - pinhole leak test fixture, heat sterilization of ethylene propylene with hydrazine, and metal diaphragms

PROPYLENE↗

Polymer Research

Network density of filled composites, nitroso compound reactions with hydrocarbons, cryogenic bladder bag materials, thermoplastic rubbers as binders, and other polymer research studies

COMPOSITE MATERIAL↗

Liquid propulsion

Expulsion bladders for liquid propellant systems, resonant combustion injector, and propellant flow separation

FLOW SEPARATION↗

Benchmark Performance Metrics of a Vane Propellant Management Device for a 0.15 m3 Liquid Hydrogen Tank

The use of cryogenic propellants has and will continue to play an integral role in manned-space exploration due the high specific impulses offered and its ubiquity through in-situ resource utilization. But guaranteeing vapor-free transfer of such low-surface tension liquids is difficult for traditional capillary-action propellant management devices (PMDs). Screen-channel liquid acquisition devices and compliant origami bladders are potential solutions, but to quantify the benefits these technologies offer, this paper present a cast study analyzing the performance metrics of an orthodox vane PMD as a benchmark for comparison. A 0.15 m3 liquid hydrogen tank at 20.3 K and 103 kPa was selected for study. Then assuming no body forces and no heat transfer (for simplicity), a steady-state 1-D differential equation was numerically solved in tandem with four possible wetted area configurations to yield an expulsion efficiency for a theoretically maximum inputted expulsion flow rate. Maximization of the flow rate was constrained by the onset of choked flow. Additional inputs, including vane height and vane number, were parametrically varied between 0.1 – 10 cm and 4 – 28 vanes, respectively.

Liquid Acquisition Device↗

Uncovering novel mutational signatures by de novo extraction with SigProfilerExtractor

Mutational signature analysis is commonly performed in cancer genomic studies. Here, we present SigProfilerExtractor, an automated tool for de novo extraction of mutational signatures, and benchmark it against another 13 bioinformatics tools by using 34 scenarios encompassing 2,500 simulated signatures found in 60,000 synthetic genomes and 20,000 synthetic exomes. For simulations with 5% noise, reflecting high-quality datasets, SigProfilerExtractor outperforms other approaches by elucidating between 20% and 50% more true-positive signatures while yielding 5-fold less false-positive signatures. Applying SigProfilerExtractor to 4,643 whole-genome- and 19,184 whole-exome-sequenced cancers reveals four novel signatures. Two of the signatures are confirmed in independent cohorts, and one of these signatures is associated with tobacco smoking. In summary, this report provides a reference tool for analysis of mutational signatures, a comprehensive benchmarking of bioinformatics tools for extracting signatures, and several novel mutational signatures, including one putatively attributed to direct tobacco smoking mutagenesis in bladder tissues.

59 BASIC BIOLOGICAL SCIENCES↗

Mechanical Performance of the First Two Prototype 4.5 m Long Nb$_3$Sn Low-$β$ Quadrupole Magnets for the Hi-Lumi LHC Upgrade

The U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) team is collaborating with CERN in the design and fabrication of the first 4.5 m long MQXFA magnets, a 150 mm aperture high-field Nb$_3$Sn quadrupole magnet that uses the aluminum shell-based bladder-and-key technology. The first two prototype magnets, MQXFAP1 and MQXFAP2, were assem-bled and tested while the first pre-series structure (MQXFA03) was in fabrication. This paper summarizes the mechanical perfor-mance of these prototype structures based on the comparison of measured strain gauge data with finite element model analyses from all load steps to powering. The MQXFAP1 magnet almost reached ultimate current before a short to ground was detected and the test was stopped. The MQXFAP2 magnet experienced a low training performance due to a fractured aluminum shell. MQXFAP1b was rebuilt with a new replacement coil, but an old coil limited the magnet from achieving the ultimate current. The mitigations and analyses of these prototype magnets are discussed in the context of the transition to pre-series production.

43 PARTICLE ACCELERATORS↗

Magnetic and Mechanical Analysis of a Large Aperture 15 T Cable Test Facility Dipole Magnet

The US Department of Energy (DOE) Office of Science (SC), is funding a large bore “Cable Test Facility Magnet” for testing advanced cables and inserts in high transverse field. This is a joint effort between the Office of High Energy Physics (HEP) and the Office of Fusion Energy Sciences (FES). The background field magnet for this facility is being developed at Lawrence Berkeley National Laboratory (LBNL) while the cryostat and test facility will be located and operated by Fermi National Accelerator Laboratory (FNAL). The Nb 3 Sn dipole magnet, which will provide the transverse background field, is designed to generate a field of 15 T in a 100 × 150 mm bore at 1.9 K. The conceptual design of a block-type dipole with flared ends and a structure based on key-and-bladder technology will be introduced. The results of the magnetic and mechanical analysis will be presented.

43 PARTICLE ACCELERATORS↗

Computation of the Strain Induced Critical Current Reduction in the 16 T Nb 3 Sn Test Facility Dipole

A test facility dipole is being developed at LBNL, targeting a 16 T field in a 144 mm wide aperture. The magnet uses a block design, with two double-pancake coils. In order to minimize motion under the large Lorentz forces, the coils are preloaded against a thick aluminum shell and iron yoke using bladder and key technology. It is then crucial to verify that the performance of the magnet is not degraded due to strain induced on the Nb 3 Sn conductor during assembly, cool-down and powering. The critical current of extracted strands was measured in a varying background magnetic field and as a function of the applied longitudinal strain. Finite element analysis was used to extract the strain state inside the superconducting strands during magnet assembly and operation. This strain was then compared to the measurements to evaluate potential reversible and irreversible effects on the magnet performances. Here the results suggest that the magnet can reach 16 T with sufficient margin, with no irreversible degradation in the high field region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Novel Design for Improving the Control on the Stainless-Steel Vessel Welding Process for Superconducting Magnets

Stainless steel vessels see widespread use in superconducting magnets for particle accelerator applications. Their function varies in different magnet designs: they always provide the necessary liquid helium containment, but in some cases are also used to provide azimuthal prestress and can also be welded to the magnet end plate to provide additional longitudinal stiffness. A magnet designed with the bladder and key technology does not rely on the structural role of the vessel. They are structurally supported using azimuthally prestressed aluminum shells, and the longitudinal constraint by rods. In this case, the magnet designer would generally like to minimize the interaction between the magnet and the stainless-steel vessel and to minimize the coil stress variation due to the vessel. The stress state in the vessel and in the coil is a function of the circumferential interference, defined as the vessel azimuthal length minus the magnet circumference. The vessel and the magnet azimuthal length machining tolerances are relatively large resulting in significant stress variations in the superconducting coils. Here in this paper we introduce an interference-control shim, which can significantly limit the stress variation of the coils for a given variation of the interference. The effectiveness of the interference-control shim is evaluated numerically on the MQXF, the low-β quadrupole for the High Luminosity LHC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual Structural Design and Analysis of a 20 T Hybrid Cos Dipole for Future Particle Colliders

Here, to reach high collision energy for future high-energy particle colliders, like the Future Circular Collider (FCC) or the Muon Collider, it is required to achieve high field strength of the bending dipoles. Currently, the practical limit for Nb$_{\text{3}}$ Sn technology is around 16 T and, in order to further increase the magnetic field, the superconducting magnet community is considering High Temperature Superconductors (HTS), in particular Bi-2212 and REBCO conductors. However, their relevant higher cost has led the community to consider a hybrid approach where HTS materials are used in the high field region of the coils with so-called insert coils, and Low Temperature Superconductors are involved in the lower field part ($< $ 16 T) with so-called outsert coils. This paper describes the conceptual mechanical design of a 20 T hybrid cos$\theta$ dipole configuration. The high stress levels that the structure is facing due to the high magnetic field are discussed. Moreover, it presents the results of the optimization analysis of the shell-based support structure based on the key-and-bladder technology that provides the azimuthal pre-stress during room temperature assembly and cooldown to cryogenic temperatures. The aim of this work is to present a feasible design that satisfies the stress requirements.

D'Addazio, Marika [Politecnico di Torino (Italy); ↗

Design of B2PF: A Large Aperture Nb-Ti Dipole Magnet for the Electron-Ion Collider

Here, we present the initial design of the matching dipole B2PF, a large aperture cosine-theta magnet for the Electron-Ion Collider (EIC). First we share an optimized 2D magnet cross-section based on a double-layer design with Nb-Ti Rutherford cable. This cross-section is optimized to meet the required field quality in the 120 mm coil aperture both at the nominal operating current and considering iron saturation effects during the ramp. Next, we share a first design of the 3D coil ends optimized for windability, field quality, and minimizing the conductor peak field. Based on the resulting peak field, we evaluate the short-sample margin of the design for an operating target of 6.3 T dipole field at 1.9 K. Finally, we share an initial mechanical design study which utilizes a key-and-bladder support structure capable of adjusting magnet preload.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

US HL-LHC Accelerator Upgrade Project (MQXFA Final Design Report)

The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.

43 PARTICLE ACCELERATORS↗