Engineering Aspects in Blood Pump Development

NASA turbomachinery computer codes assisted in the design of the Cleveland Clinic Foundation's centrifugal bladed blood pump. The codes were originally developed for the aerospace industry, but are applicable to the blood pump because of a high degree of synergy with this application. Traditional turbomachinery design criteria were used in the design of the blood pump centrifugal impeller and volute casing. The fluid dynamic performance of the blood pump is meeting the engineering design goals of flow rate and pressure rise.

Golding, Leonard↗

Blood Analyzer

In the 1970's, NASA provided funding for development of an automatic blood analyzer for Skylab at the Oak Ridge National Laboratory (ORNL). ORNL devised "dynamic loading," which employed a spinning rotor to load, transfer, and analyze blood samples by centrifugal processing. A refined, commercial version of the system was produced by ABAXIS and is marketed as portable ABAXIS MiniLab MCA. Used in a doctor's office, the equipment can perform 80 to 100 chemical blood tests on a single drop of blood and report results in five minutes. Further development is anticipated.

Source record↗

Expression of extracellular calcium (Ca2+o)-sensing receptor in human peripheral blood monocytes

The calcium-sensing receptor (CaR) is a G protein-coupled receptor playing key roles in extracellular calcium ion (Ca2+o) homeostasis in parathyroid gland and kidney. Macrophage-like mononuclear cells appear at sites of osteoclastic bone resorption during bone turnover and may play a role in the "reversal" phase of skeletal remodeling that follows osteoclastic resorption and precedes osteoblastic bone formation. Bone resorption produces substantial local increases in Ca2+o that could provide a signal for such mononuclear cells present locally within the bone marrow microenvironment. Indeed, previous studies by other investigators have shown that raising Ca2+o either in vivo or in vitro stimulated the release of interleukin-6 (IL-6) from human peripheral blood monocytes, suggesting that these cells express a Ca2+o-sensing mechanism. In these earlier studies, however, the use of reverse transcription-polymerase chain reaction (RT-PCR) failed to detect transcripts for the CaR previously cloned from parathyroid and kidney in peripheral blood monocytes. Since we recently found that non-specific esterase-positive, putative monocytes isolated from murine bone marrow express the CaR, we reevaluated the expression of this receptor in human peripheral blood monocytes. Immunocytochemistry, flow cytometry, and Western blot analysis, performed using a polyclonal antiserum specific for the CaR, detected CaR protein in human monocytes. In addition, the use of RT-PCR with CaR-specific primers, followed by nucleotide sequencing of the amplified products, identified CaR transcripts in the cells. Therefore, taken together, our data show that human peripheral blood monocytes possess both CaR protein and mRNA very similar if not identical to those expressed in parathyroid and kidney that could mediate the previously described, direct effects of Ca2+o on these cells. Furthermore, since mononuclear cells isolated from bone marrow also express the CaR, the latter might play some role in the "reversal" phase of bone remodeling, sensing local changes in Ca2+o resulting from osteoclastic bone resorption and secreting osteotropic cytokines or performing other Ca2+o-regulated functions that contribute to the control of bone turnover.

NASA Discipline Musculoskeletal↗

Elevated Skin Blood Flow Influences Near Infrared Spectroscopy Measurements During Supine Rest

Near infrared spectroscopy is a non-invasive technique that allows determination of tissue oxygenation/blood flow based on spectrophotometric quantitation of oxy- and deoxyhemoglobin present within a tissue. This technique has gained acceptance as a means of detecting and quantifying changes in tissue blood flow due to physiological perturbation, such as that which is elicited in skeletal muscle during exercise. Since the NIRS technique requires light to penetrate the skin and subcutaneous fat in order to reach the muscle of interest, changes in skin blood flow may alter the NIRS signal in a fashion unrelated to blood flow in the muscle of interest. The aim of this study was to determine the contribution of skin blood flow to the NIRS signal obtained from resting vastus lateralis muscle of the thigh.

Lee, Stuart M. C.↗

Microvascular Branching as a Determinant of Blood Flow by Intravital Particle Imaging Velocimetry

The effects of microvascular branching on blood flow were investigated in vivo by microscopic particle imaging velocimetry (micro-PIV). We use micro-PIV to measure blood flow by tracking red blood cells (RBC) as the moving particles. Velocity flow fields, including flow pulsatility, were analyzed for the first four branching orders of capillaries, postcapillary venules and small veins of the microvascular network within the developing avian yolksac at embryonic day 5 (E5). Increasing volumetric flowrates were obtained from parabolic laminar flow profiles as a function of increasing vessel diameter and branching order. Maximum flow velocities increased approximately twenty-fold as the function of increasing vessel diameter and branching order compared to flow velocities of 100 - 150 micron/sec in the capillaries. Results from our study will be useful for the increased understanding of blood flow within anastomotic, heterogeneous microvascular networks.

Parsons-Wingerter, Patricia↗

Blood-Pressure Measuring System Gives Accurate Graphic Output

The problem: To develop an instrument that will provide an external (indirect) measurement of arterial blood pressure in the form of an easily interpreted graphic trace that can be correlated with standard clinical blood-pressure measurements. From sphygmograms produced by conventional sphygmographs, it is very difficult to differentiate the systolic and diastolic blood-pressure pulses and to correlate these indices with the standard clinical values. It is nearly impossible to determine these indices when the subject is under physical or emotional stress. The solution: An electronic blood-pressure system, basically similar to conventional ausculatory sphygmomanometers, employing a standard occluding cuff, a gas-pressure source, and a gas-pressure regulator and valve. An electrical output transducer senses cuff pressure, and a microphone positioned on the brachial artery under the occluding cuff monitors the Korotkoff sounds from this artery. The output signals present the conventional systolic and diastolic indices in a clear, graphical display. The complete system also includes an electronic timer and cycle-control circuit.

Source record↗

Blood monitoring systems and methods thereof

A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

Mir, Jose↗

Characterization of Jugular Venous Blood Flow During Acute Fluid Shifts

INTRODUCTION Exposure to weightlessness induces a headward fluid shift and redistribution of fluids, resulting in increased internal jugular vein (IJV) cross-sectional area and altered IJV blood flow dynamics, including stasis and retrograde flow. These findings may contribute to various risks of spaceflight, including thrombosis or other risks affected by cerebral venous blood flow. To date, our understanding of the cerebral venous outflow dynamics in weightlessness is limited to the left IJV assessed ~45 and ~150 days into spaceflight. Therefore, it is unknown how quickly the alterations in venous blood flow dynamics change as a result of weightlessness. The purpose of this study is to determine 1) if venous stasis is an immediate effect of weightlessness and therefore a risk for short-duration missions and 2) the effect of weightlessness on brachiocephalic venous flow. METHODS In this study, we investigated the effects of acute weightlessness during parabolic flight on the right and left IJV in 12 healthy subjects. Baseline ultrasound images were obtained on the ground (1g) in the seated and supine postures and during 0g parabolic flight. Each data collection session included 2D ultrasonography to quantify IJV cross-sectional area and Doppler ultrasonography to characterize venous blood flow patterns in the bilateral IJVs. RESULTS There was a similar pattern of response in the left and right IJV area across postures and g-levels. IJV area increased from seated to supine by 0.74 mm2 (95% CI: 0.56 to 0.91 mm2, p<.001) and increased further during weightlessness by 0.29 mm2 (95% CI: 0.11 to 0.47 mm2, p=.0015). IJV Doppler images revealed stagnant flow in the left IJV in one subject during 0g exposure that was not present during any imaging on the ground; the right IJV continued to show pulsatile, nominal flow patterns in both 0g and 1g. CONCLUSIONS This study characterized the immediate effect of the weightlessness-induced headward fluid shift on venous parameters in the left and right IJV. The left IJV appears to be more susceptible to flow alterations, including stagnant flow, during both short and long-duration exposure to weightlessness that may contribute to the risk of thrombosis inflight.

K Marshall-Goebel↗

Decreases in bone blood flow and bone material properties in aging Fischer-344 rats

The purpose of this study was to quantify precisely aging-induced changes in skeletal perfusion and bone mechanical properties in a small rodent model. Blood flow was measured in conscious juvenile (2 months old), adult (6 months old), and aged (24 months old) male Fischer-344 rats using radiolabeled microspheres. There were no significant differences in bone perfusion rate or vascular resistance between juvenile and adult rats. However, blood flow was lower in aged versus adult rats in the forelimb bones, scapulas, and femurs. To test for functional effects of this decline in blood flow, bone mineral density and mechanical properties were measured in rats from these two age groups. Bone mineral density and cross-sectional moment of inertia in femoral and tibial shafts and the femoral neck were significantly larger in the aged versus adult rats, resulting in increased (+14%-53%) breaking strength and stiffness. However, intrinsic material properties at midshaft of the long bones were 12% to 25% lower in the aged rats. Although these data are consistent with a potential link between decreased perfusion and focal alterations in bone remodeling activity related to clinically relevant bone loss, additional studies are required to establish the mechanisms for this putative relationship.

Non-NASA Center↗

Blood flow dynamics in heart failure

BACKGROUND: Exercise intolerance in heart failure (HF) may be due to inadequate vasodilation, augmented vasoconstriction, and/or altered muscle metabolic responses that lead to fatigue. METHODS AND RESULTS: Vascular and metabolic responses to rhythmic forearm exercise were tested in 9 HF patients and 9 control subjects (CTL) during 2 protocols designed to examine the effect of HF on the time course of oxygen delivery versus uptake (protocol 1) and on vasoconstriction during exercise with 50 mm Hg pressure about the forearm to evoke a metaboreflex (protocol 2). In protocol 1, venous lactate and H+ were greater at 4 minutes of exercise in HF versus CTL (P<0.05) despite similar blood flow and oxygen uptake responses. In protocol 2, mean arterial pressure increased similarly in each group during ischemic exercise. In CTL, forearm blood flow and vascular conductance were similar at the end of ischemic and ambient exercise. In HF, forearm blood flow and vascular conductance were reduced during ischemic exercise compared with the ambient trial. CONCLUSIONS: Intrinsic differences in skeletal muscle metabolism, not vasodilatory dynamics, must account for the augmented glycolytic metabolic responses to moderate-intensity exercise in class II and III HF. The inability to increase forearm vascular conductance during ischemic handgrip exercise, despite a normal pressor response, suggests that enhanced vasoconstriction of strenuously exercising skeletal muscle contributes to exertional fatigue in HF.

NASA Discipline Cardiopulmonary↗

Blood biochemical and cellular changes during a decompression procedure involving eight hours of oxygen prebreathing

Chemical and cellular parameters were measured in human subjects before and after exposure to a decompression schedule involving 8 h of oxygen prebreathing. The exposure was designed to simulate space-flight extravehicular activity (EVA) for 6 h. Several statistically significant changes in blood parameters were observed following the exposure: increases in calcium, magnesium, osmolality, low-density lipoprotein cholesterol, monocytes, and prothrombin time, and decreases in chloride, creatine phosphokinase and eosinophils. The changes, however, were small in magnitude and blood factor levels remained within normal clinical ranges. Thus, the decompression profile used in this study is not likely to result in blood changes that would pose a threat to astronauts during EVA.

Oxygen/administration & dosage↗

Establishing metrics to quantify spatial similarity in spherical and red blood cell distributions

As computational power increases and systems with millions of red blood cells can be simulated, it is important to note that varying spatial distributions of cells may affect simulation outcomes. Since a single simulation may not represent the ensemble behavior, many different configurations may need to be sampled to adequately assess the entire collection of potential cell arrangements. In order to determine both the number of distributions needed and which ones to run, we must first establish methods to identify well-generated, randomly placed cell distributions and to quantify distinct cell configurations. We utilize metrics to assess (1) the presence of any underlying structure to the initial cell distribution and (2) similarity between cell configurations. We propose the use of the radial distribution function to identify long-range structure in a cell configuration and apply it to a randomly distributed and structured set of red blood cells. To quantify spatial similarity between two configurations, we make use of the Jaccard index, and characterize sets of red blood cell and sphere initializations. As an extension to our work submitted to the International Conference on Computational Science, we significantly increase our data set size from 72 to 1048 cells, include a similar set of studies using spheres, compare the effects of varying sphere size, and utilize the Jaccard index distribution to probe sets of extremely similar configurations. Our results show that the radial distribution function can be used as a metric to determine long-range structure in both distributions of spheres and RBCs. We determine that the ideal case of spheres within a cube versus bi-concave shaped cells within a cylinder affects the shape of the Jaccard index distributions, as well as the range of Jaccard values, showing that both the shape of particle and the domain may play a role. Furthermore, we also find that the distribution is able to capture very similar configurations through Jaccard index values greater than 95% when appending several nearly identical configurations into the data set.

59 BASIC BIOLOGICAL SCIENCES↗

Antimicrobial Peptides Can Facilitate Whole Blood Safety from Bacteria: A Proof of Concept

With continuous improvements to blood donor deferrals and the availability of sensitive tests for donation screening for infectious agents, bacterial contamination of whole blood (WB) and blood components stored for transfusion is a rare event. Nonetheless, it still occurs and remains a transfusion-associated risk in terms of septic transfusion reactions (STRs) and transfusion-transmitted bacterial infections with morbidity and mortality outcomes. One of the risk mitigation strategies for bacterial contamination is to implement treatment with currently available proactive pathogen reduction technologies (PRTs) for these transfusion products. Here, as a proof of concept, we tested two recently developed unique cationic antimicrobial peptides (AMPs; D-CONGA and D-CONGA-Q7) for WB safety from bacterial contamination. In this study, WB was inoculated with Escherichia coli and Staphylococcus epidermidis and treated with the two peptides to evaluate their bactericidal efficacy. The results demonstrated that D-CONGA and D-CONGA-Q7 exhibit potent inhibitory activity against the bacteria with a minimal inhibitory concentration (MIC) range of 4–8 and 1–8 μM, respectively, depending on the bacterial species tested. Time-kill kinetics further confirmed that the peptides exhibit bactericidal efficacy at 8 μM by achieving a 5-log 10 reduction (99.999%) of the bacterial load in WB with a time-dependent killing profile. Furthermore, even at 20 μM, the AMPs did not negatively impact hemolysis or hemostatic properties. We have further demonstrated using a cationic exchange resin that the cationic AMPs can be separated and removed from WB after the peptide treatments. During 35-day WB storage at 2–8 °C, 4 μM D-CONGA-Q7 one-time treatment prevented S. epidermidis growth and preserved WB quality and integrity. Overall, the results described here provide the first proof of concept that certain AMPs, such as D-CONGA and D-CONGA-Q7, can facilitate WB safety from bacteria during storage.

60 APPLIED LIFE SCIENCES↗

Peripheral blood hematology, plasma biochemistry, and the optimization of an in vitro immune-based assay in the brown watersnake ( Nerodia taxispilota )

Reptiles represent a phylogenetic lineage that provides a unique link between ectothermic anamniotes and endothermic amniotes. Compared to mammalian and avian species, our understanding of the reptilian immune system is greatly lacking. This gap in knowledge is largely due to an absence of established immune-based assays or specific reagents for these species. In the present study, brown watersnakes (Nerodia taxispilota) were live-captured in the wild, sexed, weighed, measured, bled via the caudal vein and released. At 24 hr post-collection, peripheral blood leukocytes were enriched and evaluated with an established mammalian in-vitro lymphocyte proliferation assay. Snake peripheral blood leukocyte enrichment yielded > 90% lymphocytes with viabilities averaging 81.5%. Baseline physiologic data for N. taxispilota, including hematology and total solids, leukocyte differentials, cell recovery and plasma biochemistry, were also collected. Cells cultured with Concanavalin A exhibited significantly increased proliferation at both 72 and 96 hr. Furthermore, these preliminary results show that enriched peripheral blood from wild-caught N. taxispilota provides a sufficient yield of leukocytes that can be cultured and functionally evaluated using a standard mammalian in-vitro immune-based assay.

59 BASIC BIOLOGICAL SCIENCES↗

Defining blood hematology reference values in female pig-tailed macaques ( Macaca nemestrina ) using the Isolation Forest algorithm

Background: Pig-tailed macaques (PTMs) are commonly used as preclinical models to assess antiretroviral drugs for HIV prevention research. Drug toxicities and disease pathologies are often preceded by changes in blood hematology. To better assess the safety profile of pharmaceuticals, we defined normal ranges of hematological values in PTMs using an Isolation Forest (iForest) algorithm. Methods: Eighteen female PTMs were evaluated. Blood was collected 1–24 times per animal for a total of 159 samples. Complete blood counts were performed, and iForest was used to analyze the hematology data to detect outliers. Results: Median, IQR, and ranges were calculated for 13 hematology parameters. From all samples, 22 outliers were detected. These outliers were excluded from the reference index. Conclusions: Using iForest, we defined a normal range for hematology parameters in female PTMs. This reference index can be a valuable tool for future studies evaluating drug toxicities in PTMs.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of Blood Rheology and Turbulence Models in the Numerical Simulation of Aneurysms

An aneurysm is a vascular malformation that can be classified according to its location (cerebral, aortic) or shape (saccular, fusiform, and mycotic). Recently, the study of blood flow interaction with aneurysms has gained attention from physicians and engineers. Shear stresses, oscillatory shear index (OSI), gradient oscillatory number (GON), and residence time have been used as variables to describe the hemodynamics as well as the origin and evolution of aneurysms. However, the causes and hemodynamic conditions that promote their growth are still under debate. The present work presents numerical simulations of three types of aneurysms: two aortic and one cerebral. Simulation results showed that the blood rheology is not relevant for aortic aneurysms. However, for the cerebral aneurysm case, blood rheology could play a relevant role in the hemodynamics. The evaluated turbulence models showed equivalent results in both cases. Lastly, a simulation considering the fluid–structure interaction (FSI) showed that this phenomenon is the dominant factor for aneurysm simulation.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of furosemide on pulmonary blood flow distribution in resting and exercising horses

We determined the spatial distribution of pulmonary blood flow (PBF) with 15-micron fluorescent-labeled microspheres during rest and exercise in five Thoroughbred horses before and 4 h after furosemide administration (0.5 mg/kg iv). The primary finding of this study was that PBF redistribution occurred from rest to exercise, both with and without furosemide. However, there was less blood flow to the dorsal portion of the lung during exercise postfurosemide compared with prefurosemide. Furosemide did alter the resting perfusion distribution by increasing the flow to the ventral regions of the lung; however, that increase in flow was abated with exercise. Other findings included 1) unchanged gas exchange and cardiac output during rest and exercise after vs. before furosemide, 2) a decrease in pulmonary arterial pressure after furosemide, 3) an increase in the slope of the relationship of PBF vs. vertical height up the lung during exercise, both with and without furosemide, and 4) a decrease in blood flow to the dorsal region of the lung at rest after furosemide. Pulmonary perfusion variability within the lung may be a function of the anatomy of the pulmonary vessels that results in a predominantly fixed spatial pattern of flow distribution.

NASA Discipline Cardiopulmonary↗

Effects of exposure to simulated microgravity on neuronal catecholamine release and blood pressure responses to norepinephrine and angiotensin

We tested the hypothesis that exposure to microgravity reduces the neuronal release of catecholamines and blood pressure responses to norepinephrine and angiotensin. Eight men underwent 30 days of 6 degrees head-down tilt (HDT) bedrest to simulate exposure to microgravity. Plasma norepinephrine and mean arterial blood pressure (MAP) were measured before and after a cold pressor test (CPT) and graded norepinephrine infusion (8, 16 and 32 ng/kg/min) on day 6 of a baseline control period (C6) and on days 14 and 27 of HDT. MAP and plasma angiotensin II (Ang-II) were measured during graded Ang-II infusion (1, 2 and 4 ng/kg/min) on C8 and days 16 and 29 of HDT. Baseline total circulating norepinephrine was reduced from 1017ng during the baseline control period to 610 ng at day 14 and 673ng at day 27 of HDT, confirming a hypoadrenergic state. An elevation of norepinephrine (+178 ng) to the CPT during the baseline control period was eliminated by HDT days 14 and 27. During norepinephrine infusion, similar elevations in plasma norepinephrine (7.7 pg/ml/ng/kg/min) caused similar elevations in MAP (0.12 mmHg/ng/kg/min) across all test days. Ang-II infusion produced higher levels of plasma Ang-II during HDT (47.3 pg/ml) than during baseline control (35.5 pg/ml), while producing similar corresponding elevations in blood pressure. While vascular responsiveness to norepinephrine appears unaffected, impaired neuronal release of norepinephrine and reduced vascular responsiveness to Ang-II might contribute to the lessened capacity to vasoconstrict after spaceflight. The time course of alterations indicates effects that occur within two weeks of exposure.