Search NASA⌕ Search

SEARCH · Search NASA

Results for “BLOOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Initial blood storage experiment

The possibility of conducting experiments with the formed elements of the blood under conditions of microgravity opens up important opportunities to improve the understanding of basic formed element physiology, as well as, contribution to improved preservation of the formed elements for use in transfusion. The physiological, biochemical, and physical changes of the membrane of the erythrocyte, platelet, and leukocyte was studied during storage under two specific conditions: standard blood bank conditions and microgravity, utilizing three FDA approved plastic bags. Storage lesions; red cell storage on Earth; platelet storage on Earth; and leukocyte storage Earth were examined. The interaction of biomaterials and blood cells was studied during storage.

Surgenor, Douglas MACN.↗

Evaluation of Cutaneous Blood Flow During Lower Body Negative Pressure to Prevent Orthostatic Intolerance of Bedrest

Orthostatic tolerance is markedly impaired in most of the crewmembers during space flight and could seriously compromise crew safety during and immediately after landing. NASA investigators are studying the use of lower body negative pressure (LBNP) as a countermeasure to this intolerance. It is hypothesized that the continuously changing vascular pressure induced by sinusoidal LBNP with an additional countermeasure of salt and water will help crewmembers to be in a more acceptable physiologic condition to enter the earth's atmosphere. In ground based studies, subjects on bedrest provide the model for studying the physiologic effects of weightlessness. When subjects are treated with sinusoidal LBNP, negative pressures ranging from 0 to -60 mm/Hg are administered during a two hour period. This increases body fluids in the legs and lower body. This paper reports the results of two subjects who were placed on bedrest for six days. The subjects were randomly selected for either the control or treatment mode. The subject receiving the treatment mode ingested salt tablets and water on day 4 of the bedrest period. A ramp LBNP of two hours was next administered to this subject. The control subject did not receive anything during the bedrest period. Laser Doppler was used to measure the cutaneous blood flow of the forearm and calf to monitor vasoconstrictor effects of the baroreceptor reflex. Data indicated that skin blood flow in the treatment subject was higher than baseline in the forearm while the skin blood flow was decreased in the control subject.

Rubin, Marilyn↗

Fatigability and blood flow in the rat gastrocnemius-plantaris-soleus after hindlimb suspension

The hypothesis that hindlimb suspension (HS) increases the fatigability of the soleus during intense contractile activity and that the increased fatigue is associated with a reduced muscle blood flow was tested using caged control rats and rats subjected to HS for 15 days. After 15 days, either the soleus or the gastrocnemius-plantaris-soleus (G-P-S) muscle group was stimulated in situ (10 min at 100 Hz, 100 ms trains at 120/min), and in the G-P-S preparation, blood flow was measured with radiolabeled microspheres before and at 2 min and 10 min after the start of contractile activity. The results indicate that 15 days of HS resulted in increased fatigability of the soleus, but the effect was not caused by a reduced muscle blood flow.

Mcdonald, K. S.↗

Cerebral blood flow - Comparison of ground-based and spaceflight data and correlation with space adaptation syndrome

The relationship between the cerebral blood flow velocity and the space adaptation syndrome (SAS), which includes symptoms of motion sickness, stuffy head, and/or headaches, was investigated by measuring (using a transcranial Doppler device) differences between the preflight and the inflight cerebral blood flow velocity in crew members who were motion sick and in those who were not sick during a flight aboard KC-135. It was found that the cerebral artery bloodflow inflight did not differ significantly from that recorded preflight, nor did the severity of SAS symptoms correlate directly with the cerebral blood flow.

Bagian, James P.↗

Direct measurement of capillary blood pressure in the human lip

In this study, we developed and tested a new procedure for measuring microcirculatory blood pressures above heart level in humans. Capillary and postcapillary venule blood pressures were measured directly in 13 human subjects by use of the servonulling micropressure technique adapted for micropuncture of lip capillaries. Pressure waveforms were recorded in 40 separate capillary vessels and 14 separate postcapillary venules over periods ranging from 5 to 64 s. Localization and determination of capillary and postcapillary vessels were ascertained anatomically before pressure measurements. Capillary pressure was 33.2 +/- 1.5 (SE) mm Hg in lips of subjects seated upright. Repeated micropunctures of the same vessel gave an average coefficient of variation of 0.072. Postcapillary venule pressure was 18.9 +/- 1.6 mm Hg. This procedure produces a direct and reproducible means of measuring microvascular blood pressures in a vascular bed above heart level in humans.

Parazynski, S. E.↗

Ambulatory blood pressure and heart rate during shuttle flight, entry and landing

Ambulatory blood pressures (BP) and heart rates (HR) were recorded on a series of early Shuttle flights during preflight and pre-entry, entry, landing and egress. There were no significant differences between flight and preflight values during routine activity. Systolic blood pressure was slightly elevated in the deorbit period and systolic and diastolic blood pressure and heart rates were all elevated with onset of gravitoinertial loads and remained so through egress. Two of seven subjects had orthostatic problems in egress but their data did not show significant differences from others except in heart rate. Comparison of this data to that from recent studies show even larger increase in HR/BP values during current deorbit and entry phases which is consistent with increased heat and weight loads imposed by added survival gear. Both value and limitations of ambulatory heart rate/blood pressure data in this situation are demonstrated.

Thornton, W.↗

Extended duration orbiter medical project variability of blood pressure and heart rate (STS-50/USML-1)

Decreases in arterial baroreflex function after space flight may be related to changes in blood pressure and heart rate patterns during flight. Ambulatory blood pressure and heart rate were measured for 24 hours, in fourteen astronauts on two occasions before flight, two to three occasions in flight, and 2 days after landing on Shuttle missions lasting 4 to 14 days. Blood pressure and heart rate were recorded every 20minutes during awake periods and every 30 minutes during sleep. In pre- and postflight studies, the 24-hour ambulatory measurements were followed by studies of carotid baroreceptor-cardiac reflex responses. Carotid baroreceptors were stimulated using a sequence of neck pressure and suction from +40 to -65 mmHg.

Fritsch-Yelle, Janice M.↗

Responses of heart rate and blood pressure to KC-135 hyper-gravity

Many investigators have clarified the effects of hyper gravitational-inertial forces (G) upon the cardiovascular system, using the centrifugal apparatus with short rotating radius. We investigated the cardiovascular responses to KC-135 hyper-G flight with negligibly small angular velocity. Six normal, healthy subjects 29 to 40 years old (5 males and 1 female) took part in this experiment. Hyper gravitational-inertial force was generated by the KC-135 hyper-G flight, flown in a spiral path with a very long radius of 1.5 miles. Hyper-G was sustained for 3 minutes with 1.8 +Gz in each session and was repeatedly exposed to very subject sitting on a chair 5 times. The preliminary results of blood pressure and R-R interval are discussed. An exposure of 1.8 +Gz stress resulted in a remarkable increase of systolic and diastolic blood pressure, while the pulse pressure did not change and remained equal to the control level regardless of an exposure of hyper-G. These results in blood pressure indicate an increase of resistance in the peripheral vessels, when an exposure of hyper-G was applied. The R-R interval was calculated from ECG. R-R interval in all subjects was changed but not systematically, and R-R interval became obviously shorter during the hyper-G period than during the 1 +Gz control period although R-R interval varied widely in some cases. The coefficient of variation of R-R interval was estimated to determine the autonomic nerve activity, but no significant change was detectable.

Satake, Hirotaka↗

Blood Pump Bearing System

Methods and apparatus are provided for a blood pump bearing system within a pump housing to support long-term high-speed rotation of a rotor with an impeller blade having a plurality of individual magnets disposed thereon to provide a small radial air gap between the magnets and a stator of less than 0.025 inches. The bearing system may be mounted within a flow straightener, diffuser, or other pump element to support the shaft of a pump rotor. The bearing system includes a zirconia shaft having a radiused end. The radiused end has a first radius selected to be about three times greater than the radius of the zirconia shaft. The radiused end of the zirconia shaft engages a flat sapphire endstone. Due to the relative hardness of these materials a flat is quickly produced during break-in on the zirconia radiused end of precisely the size necessary to support thrust loads whereupon wear substantially ceases. Due to the selection of the first radius, the change in shaft end-play during pump break-in is limited to a total desired end-play of less than about 0.010 inches. Radial loads are supported by an olive hole ring jewel that makes near line contact around the circumference of the shaft to support high speed rotation with little friction. The width of olive hole ring jewel is small to allow heat to conduct through to thereby prevent heat build-up in the bearing. A void defined by the bearing elements may fill with blood that then coagulates within the void. The coagulated blood is then conformed to the shape of the bearing surfaces.

Aber, Gregory S.↗

Launch Conditions Might Affect the Formation of Blood Vessel in the Quail Chorioallantoic Membrane

AS 2 part of the first joint USA-Russian MIR/Shuttle program, fertilized quail eggs were flown on the MIR 18 mission. Post-flight examination indicated impaired survival of both the embryos in space and also of control embryos exposed to vibrational and g-forces simulating the conditions experienced during the launch of Progress 227. We hypothesized that excess mechanical forces and/or other conditions during the launch might cause abnormal development of the blood supply in the chorioallantoic membrane (CAM) leading to the impaired survival of the embryos. The CAM, a highly vascularized extraembryonic organ, provides for the oxygen exchange across the egg shell and is thus pivotal for proper embryonic development. To test our hypothesis, we compared angiogenesis In CAMS of eggs which were either exposed to the vibration and g-force profile simulating the conditions at launch of Progress 227 (synchronous controls), or kept under routine conditions in a laboratory Incubator (laboratory controls). At various time points during Incubation, the eggs were fixed in paraformaldehyde for subsequent dissection. At the time of dissection, the CAM was carefully lifted from the egg shell and examined as whole mounts by bright-field and fluorescent microscopy. The development or the vasculature (angiogenesis) was assessed from the density of blood vessels per viewing field and evaluated by computer aided image analysis. We observed a significant decrease In blood-vessel density in the synchronous controls versus "normal" laboratory controls beginning from day 10 of Incubation. The decrease in vascular density was restricted to the smallest vessels only, suggesting that conditions during the launch and/or during the subsequent Incubation of the eggs may affect the normal progress of angiogenesis in the CAM. Abnormal angiogenesis In the CAM might contribute to the impaired survival of the embryos observed in synchronous controls as well as in space.

Henry, M. K.↗

Development of a Whole Blood Staining Device for use During Space Shuttle Flights

Exposure to microgravity during space flight results in profound physiologic changes. Numerous studies have shown changes in circulating populations of peripheral blood immune cells immediately after space flight. It is currently unknown if these changes result from exposure to microgravity or are caused by the stress of reentry and readaptation to gravity. We have developed the whole blood staining device as a system for the staining of whole blood collected during space flight for subsequent flow cytometric analysis, This device contains all liquids to address safety issues concerned with space flight and also moves the cells through the staining, lyse/fixation and dilution steps.

Sams, Clarence F.↗

Blood Pump Bearing System

An apparatus is provided for a blood pump bearing system within a pump housing to support long-term highspeed rotation of a rotor with an impeller blade having a plurality of individual magnets disposed thereon to provide a small radial air gap between the magnets and a stator of less than 0.025 inches. The bearing system may be mounted within a flow straightener, diffuser, or other pump element to support the shaft of a pump rotor. The bearing system includes a zirconia shaft having a radiused end. The radiused end has a first radius selected to be about three times greater than the radius of the zirconia shaft. The radiused end of the zirconia shaft engages a flat sapphire endstone. Due to the relative hardness of these materials a flat is quickly produced during break-in on the zirconia radiused end of precisely the size necessary to support thrust loads whereupon wear substantially ceases. Due to the selection of the first radius, the change in shaft end-play during pump break-in is limited to a total desired end-play of less than about 0.010 inches. Radial loads are supported by an olive hole ring jewel that makes near line contact around the circumference of the Ir shaft to support big speed rotation with little friction. The width of olive hole ring jewel is small to allow heat to conduct through to thereby prevent heat build-up in the bearing. A void defined by the bearing elements may fill with blood that then coagulates within the void. The coagulated blood is then conformed to the shape of the bearing surfaces.

Aber, Gregory S.↗

Blood Collection

The method that is used for the collection, storage and real-time analysis of blood and other bodily fluids has been licensed to DBCD, Inc. by NASA. The result of this patent licensing agreement has been the development of a commercial product that can provide serum or plasma from whole blood volumes of 20 microliters to 4 milliliters. The device has a fibrous filter with a pore size of less than about 3 microns, and is coated with a mixture of mannitol and plasma fraction protein. The coating causes the cellular fraction to be trapped by the small pores, leaving the cellular fraction intact on the fibrous filter while the acellular fraction passes through the filter for collection in unaltered form from the serum sample collection chamber. The method used by this product is useful to NASA for blood analysis on manned space missions.

Source record↗

Blood Pressure Control

Engineering Development Laboratory developed a system for the cardiovascular study of weightless astronauts. This was designed to aid people with congestive heart failure and diabetes. While in space, astronauts' blood pressure rises, heart rate becomes unstable, and there are sometimes postflight lightheadedness or blackouts. The Baro-Cuff studies the resetting of blood pressure. When a silicone rubber chamber is strapped to the neck, the Baro-Cuff stimulates the carotid arteries by electronically controlled pressure application. Blood pressure controls in patients may be studied.

Source record↗

Storing Blood Cells

The National Cancer Institute worked with Goddard Space Flight Center to propose a solution to the blood-cell freezing problem. White blood cells and bone marrow are stored for future use by leukemia patients as a result of Goddard and Jet Propulsion Laboratory expertise in electronics and cryogenics. White blood cell and bone marrow bank established using freezing unit. Freezing unit monitors temperature of cells themselves. Thermocouple placed against polyethylene container relays temperature signals to an electronic system which controls small heaters located outside container. Heaters allow liquid nitrogen to circulate at constant temperature and maintain consistent freezing rate. Ability to freeze, store, and thaw white cells and bone marrow without damage is important in leukemia treatment.

Source record↗

Simulation of Local Blood Flow in Human Brain under Altered Gravity

In addition to the altered gravitational forces, specific shapes and connections of arteries in the brain vary in the human population (Cebral et al., 2000; Ferrandez et al., 2002). Considering the geometric variations, pulsatile unsteadiness, and moving walls, computational approach in analyzing altered blood circulation will offer an economical alternative to experiments. This paper presents a computational approach for modeling the local blood flow through the human brain under altered gravity. This computational approach has been verified through steady and unsteady experimental measurements and then applied to the unsteady blood flows through a carotid bifurcation model and an idealized Circle of Willis (COW) configuration under altered gravity conditions.

Kim, Chang Sung↗

PIV Investigations of the Flow Field in the Volute of a Rotary Blood Pump

A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indecies of the fluid, the pump casing and the impeller were matched to facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 90 mmHg and at a maximum flow condition. Four hundred data pairs were used for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately 2.9%.

Sankovic, John M.↗

Effects of spaceflight on rat peripheral blood leukocytes and bone marrow progenitor cells

The white blood cell (WBC) elements and the bone marrow myeloid progenitor cell populations were analyzed to ascertain adaptation to micro-gravity and subsequent readaptation to 1 G in rats flown on the 14-day Spacelab Life Sciences-2 (SLS-2) mission. Bone marrow cells were harvested from one group of rats killed inflight (FD13) and blood was drawn from three other groups at various times. The WBC level was normal on FD14 with the exception of neutrophilia. On FD13, numbers of colony-forming units-granulocyte (CFU-G), CFU-GM, and CFU-M from flight animals were decreased compared with ground controls when incubated with recombinant rat interleukin-3 (rrIL-3) alone or in combination with recombinant human erythropoietin (rhEpo). On recovery (R + 0), flight rats had decreased numbers of total leukocytes and absolute numbers of lymphocytes and monocytes with elevated neutrophils compared with control rats. They had lower numbers of CD4, CD8, CD2, CD3, and B cells in the peripheral blood but no differences in spleen lymphocytes.

NASA Discipline Number 00-00↗