Search NASA⌕ Search

SEARCH · Search NASA

Results for “BOLTS - STRESSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Optimized bolted joint

A method is disclosed for joining segments of the skin of an aircraft. The ends of the skin are positioned in close proximity or abutt each other. The skin is of constant thickness throughout the joint and is sandwiched between splice plates, which taper in thickness from the last to the first bolt rows in order to reduce the stiffness of the splice plate and thereby reduce the load transfer at the location where bypass loads are the highest.

Hart-Smith, L. J.↗

An Application of Retroduction to Analyzing and Testing the Backing off of Nuts and Bolts During Dynamic Loading

The method of retroduction, adapted from the doctoral thesis of Dr. A. Croce, relies on a process of dialectic questioning that begins with the information sought, proceeds to Given items (either in the form of dimensions or limits of research). and to Known mathematical forms of analysis in design or to principles of study in research. Finally, analysis and synthesis are used to abstract the dielectic questions and to arrive at the information desired. This method is used to solve the engineering design problem of a beam and to determine why bolts and nuts vibrate apart. Both mathematical analysis and dialectic logical analysis are utilized. Results are provided of tests conducted to check the retroductive study of why and how nuts back off.

Kerley, James J.↗

Bearing-Bypass Loading On Bolted Composite Joints

Unexpected interaction between effects of bypass and bearing loads reported. Combined experimental and analytical study described in NASA technical memorandum conducted to investigate effects of simultaneous bearing and bypass loading on graphite/epoxy laminate. Results important in emerging technology of composites for use in wide range of applications. Includes applications in aircraft, boats, and automobiles, in which bolted connections to composites increasingly important.

Crews, John H.↗

Spring-Loaded-Bolt Locking Device

Locking device designed to clamp small objects temporarily onto object or vehicle that accelerates. Intended to be used in place of toggle clamp, which can snap out of lock during excessive shock or vibration or because of accidental contact of person or object with toggle locking handle. Device looks and operates somewhat like spring-loaded door bolt. Moderate vibrations do not cause accidental unlocking.

Calco, Frank S.↗

Experimental determination of satellite bolted joints thermal resistance

The thermal resistance was experimentally determined of the bolted joints of the first Brazilian satellite (SCD 01). These joints, used to connect the satellite structural panels, are reproduced in an experimental apparatus, keeping, as much as possible, the actual dimensions and materials. A controlled amount of heat is forced to pass through the joint and the difference of temperature between the panels is measured. The tests are conducted in a vacuum chamber with liquid nitrogen cooled walls, that simulates the space environment. Experimental procedures are used to avoid much heat losses, which are carefully calculated. Important observations about the behavior of the joint thermal resistance with the variation of the mean temperature are made.

Mantelli, Marcia Barbosa Henriques↗

Repeated Torque Cycles Reduce Bolt Preload

Report describes experiment to determine effect of repeated torque cycles upon preload applied by bolt tightened to given torque. Results indicate preload attainable at given torque decreases on subsequent cycles.

Akian, Richard A.↗

Crushable Washers For Bolting Composite Panels

Crushable washers proposed for use in protecting composite-material (matrix/fiber) panels against overloads applied by nut-and-bolt fasteners. Intended for use at drilled holes, where strengths of composite panels reduced by exposure of ends of fibers. Washer consists of metal skin filled with microcapsules of epoxy resin and hardener. Alternatively, filled with fibers collapsing under given load. Crushing action simultaneously fractures microcapsules (if used), releasing components of epoxy. These components mix and fill bolthole and fiber-reinforcement interstices. Epoxy then hardens, locking fasteners in place.

Daech, Alfred F.↗

Reinsertable Captive Bolt

Captive bolt installed, removed, and reinstalled easily, even with heavily gloved hands depriving technicians of feeling of engagement of threads. Has two threads with different diameters but same pitch. Engages either housing or mating part. Useful in construction in environments where visibility, tactility, and/or maneuverability poor.

Smallcombe, Richard D.↗

Safety Retainer For Shackle Bolt

Shackle-bolt retainer installed and removed quickly. Retainer installed on shackle used to lift heavy loads. Reusable locking device replaces safety wire.

Falls, Elwood S.↗

Analysis Of Bolt Loads In Simple Joints

NASA technical memorandum presents theoretical analysis of tensile loads on preloaded and nonpreloaded bolts in simple symmetric and asymmetric joints.

Lee, H. M.↗

Apparatus For Eddy-Current Inspection Of Bolts

Eddy-current apparatus for inspection of bolts, studs, and other threaded fasteners detects flaws in threads, shanks, and head fillets. With help of apparatus, technician quickly inspects fasteners of various dimensions. Accommodates fasteners with diameters from 0.190 in. to 1 in. and with lengths up to 5 in. Basic design modified to accommodate fasteners of other sizes.

Amos, Jay M.↗

Experimental observations of scale effects on bonded and bolted joints in composite structures

The objective is to observe size (scale) effects in (1) fiber dominated laminates and bolted joints, (2) adhesive (matrix) dominated bonded joints with fiber dominated laminate adherends, and (3) matrix dominated laminates. Selected literature on scale effects is reviewed with comments and test data from one source that is analyzed for predicted and actual scale effects utilizing uniaxial loaded static strength, spectrum fatigue residual strength, and spectrum fatigue lifetime test results. Causes of scale effects are discussed, the results are summarized, and conclusions are made.

Grimes, Glenn C.↗

Design and evaluation of a bolted joint for a discrete carbon-epoxy rod-reinforced hat section

The use of prefabricated pultruded carbon-epoxy rods has reduced the manufacturing complexity and costs of stiffened composite panels while increasing the damage tolerance of the panels. However, repairability of these highly efficient discrete stiffeners has been a concern. Design, analysis, and test results are presented in this paper for a bolted-joint repair for the pultruded rod concept that is capable of efficiently transferring axial loads in a hat-section stiffener on the upper skin segment of a heavily loaded aircraft wing component. A tension and a compression joint design were evaluated. The tension joint design achieved approximately 1.0% strain in the carbon-epoxy rod-reinforced hat-section and failed in a metal fitting at 166% of the design ultimate load. The compression joint design failed in the carbon-epoxy rod-reinforced hat-section test specimen area at approximately 0.7% strain and at 110% of the design ultimate load. This strain level of 0.7% in compression is similar to the failure strain observed in previously reported carbon-epoxy rod-reinforced hat-section column tests.

Rousseau, Carl Q.↗

Design and Evaluation of a Bolted Joint for a Discrete Carbon-Epoxy Rod-Reinforced Hat Section

The use of pre-fabricated pultruded carbon-epoxy rods has reduced the manufacturing complexity and costs of stiffened composite panels while increasing the damage tolerance of the panels. However, repairability of these highly efficient discrete stiffeners has been a concern. Design, analysis, and test results are presented in this paper for a bolted-joint repair for the pultruded rod concept that is capable of efficiently transferring axial loads in a hat-section stiffener on the upper skin segment of a heavily loaded aircraft wing component. A tension and a compression joint design were evaluated. The tension joint design achieved approximately 1.0 percent strain in the carbon-epoxy rod-reinforced hat-section and failed in a metal fitting at 166 percent of the design ultimate load. The compression joint design failed in the carbon-epoxy rod-reinforced hat-section test specimen area at approximately 0.7 percent strain and at 110 percent of the design ultimate load. This strain level of 0.7 percent in compression is similar to the failure strain observed in previously reported carbon-epoxy rod-reinforced hat-section column tests.

Baker, Donald J.↗

Quick-Connect Bolt

A quick-connect bolt that can be inserted into a threaded receptacle without rotation and tightened with a minimum number of rotations is described.

Weddendorf, Bruce↗

Torque Limit for Bolted Joint For Composites: Experimentation - Part B

Today, aerospace quality composite parts are generally made from either a unidirectional tape or a fabric prepreg form depending on the application. The matrix material, typically epoxy because of it dimensional stability, is pre-impregnated onto the fibers to ensure uniform distribution. Both of these composite forms are finding themselves used in applications where a joint is required. Two widely used joint methods are the classic mechanically fastened joint, and the contemporary bonded joint; however, the mechanically fastened joint is most commonly used by design engineers. A major portion of the research up-to-date about bolted composite joints has dealt with the inplane static load capacity. This work has helped to spawn standards dealing with filled-hole static joint strength. Other research has clearly shown that the clamp-up load in the mechanical fastener significantly affects the joint strength in a beneficial manner by reducing the bearing strength dependence of the composite laminate. One author reported a maximum increase in joint strength of 28%. This finding has helped to improve the reliability and efficiency of the joint in a composite structure.

Kostreva, Kristian M.↗

Stable, Thermally Conductive Fillers for Bolted Joints

A commercial structural epoxy [Super Koropon (or equivalent)] has been found to be a suitable filler material for bolted joints that are required to have large thermal conductances. The contact area of such a joint can be less than 1 percent of the apparent joint area, the exact value depending on the roughnesses of the mating surfaces. By occupying the valleys between contact peaks, the filler widens the effective cross section for thermal conduction. In comparison with prior thermal joint-filler materials, the present epoxy offers advantages of stability, ease of application, and -- as a byproduct of its stability -- lasting protection against corrosion. Moreover, unlike silicone greases that have been used previously, this epoxy does not migrate to contaminate adjacent surfaces. Because this epoxy in its uncured state wets metal joint surfaces and has low viscosity, it readily flows to fill the gaps between the mating surfaces: these characteristics affect the overall thermal conductance of the joint more than does the bulk thermal conductivity of the epoxy, which is not exceptional. The thermal conductances of metal-to-metal joints containing this epoxy were found to range between 5 and 8 times those of unfilled joints.

LeVesque, Raymond J., II↗