Materials Data on BO3 by Materials Project

BO3 crystallizes in the trigonal P3_2 space group. The structure is zero-dimensional and consists of six boric acid molecules. B is bonded in a trigonal planar geometry to three O atoms. There is one shorter (1.37 Å) and two longer (1.38 Å) B–O bond length. There are three inequivalent O sites. In the first O site, O is bonded in a single-bond geometry to one B atom. In the second O site, O is bonded in a single-bond geometry to one B atom. In the third O site, O is bonded in a single-bond geometry to one B atom.

36 MATERIALS SCIENCE↗

Materials Data on NaB7(H9O10)2 by Materials Project

NaB6H13O16H3BO3H2O crystallizes in the monoclinic P2_1/c space group. The structure is zero-dimensional and consists of four boric acid molecules, four water molecules, and two NaB6H13O16 clusters. In each NaB6H13O16 cluster, Na1+ is bonded in a 6-coordinate geometry to one H1+ and five O2- atoms. The Na–H bond length is 2.50 Å. There are a spread of Na–O bond distances ranging from 2.33–2.60 Å. There are six inequivalent B3+ sites. In the first B3+ site, B3+ is bonded in a trigonal planar geometry to three O2- atoms. There are a spread of B–O bond distances ranging from 1.37–1.39 Å. In the second B3+ site, B3+ is bonded in a trigonal planar geometry to three O2- atoms. There are a spread of B–O bond distances ranging from 1.35–1.41 Å. In the third B3+ site, B3+ is bonded in a trigonal planar geometry to three O2- atoms. There are a spread of B–O bond distances ranging from 1.37–1.40 Å. In the fourth B3+ site, B3+ is bonded in a trigonal planar geometry to three O2- atoms. There is two shorter (1.37 Å) and one longer (1.41 Å) B–O bond length. In the fifth B3+ site, B3+ is bonded in a distorted trigonal planar geometry to three O2- atoms. There are a spread of B–O bond distances ranging from 1.32–1.45 Å. In the sixth B3+ site, B3+ is bonded in a trigonal planar geometry to three O2- atoms. There are a spread of B–O bond distances ranging from 1.35–1.42 Å. There are thirteen inequivalent H1+ sites. In the first H1+ site, H1+ is bonded in a single-bond geometry to one O2- atom. The H–O bond length is 0.98 Å. In the second H1+ site, H1+ is bonded in a distorted single-bond geometry to two O2- atoms. There is one shorter (1.00 Å) and one longer (1.68 Å) H–O bond length. In the third H1+ site, H1+ is bonded in a single-bond geometry to one O2- atom. The H–O bond length is 0.99 Å. In the fourth H1+ site, H1+ is bonded in a single-bond geometry to one O2- atom. The H–O bond length is 0.98 Å. In the fifth H1+ site, H1+ is bonded in a distorted linear geometry to two O2- atoms. There is one shorter (1.01 Å) and one longer (1.64 Å) H–O bond length. In the sixth H1+ site, H1+ is bonded in a single-bond geometry to one Na1+ and one O2- atom. The H–O bond length is 1.00 Å. In the seventh H1+ site, H1+ is bonded in a single-bond geometry to one O2- atom. The H–O bond length is 0.98 Å. In the eighth H1+ site, H1+ is bonded in a single-bond geometry to one O2- atom. The H–O bond length is 0.98 Å. In the ninth H1+ site, H1+ is bonded in a single-bond geometry to one O2- atom. The H–O bond length is 0.98 Å. In the tenth H1+ site, H1+ is bonded in a single-bond geometry to one O2- atom. The H–O bond length is 0.98 Å. In the eleventh H1+ site, H1+ is bonded in a distorted single-bond geometry to one O2- atom. The H–O bond length is 0.99 Å. In the twelfth H1+ site, H1+ is bonded in a single-bond geometry to one O2- atom. The H–O bond length is 1.00 Å. In the thirteenth H1+ site, H1+ is bonded in a single-bond geometry to one O2- atom. The H–O bond length is 1.00 Å. There are sixteen inequivalent O2- sites. In the first O2- site, O2- is bonded in a distorted bent 120 degrees geometry to two B3+ atoms. In the second O2- site, O2- is bonded in a distorted bent 120 degrees geometry to two B3+ atoms. In the third O2- site, O2- is bonded in a bent 120 degrees geometry to two B3+ atoms. In the fourth O2- site, O2- is bonded in a bent 120 degrees geometry to two B3+ atoms. In the fifth O2- site, O2- is bonded in a bent 120 degrees geometry to two B3+ atoms. In the sixth O2- site, O2- is bonded in a distorted bent 150 degrees geometry to two B3+ atoms. In the seventh O2- site, O2- is bonded in a bent 120 degrees geometry to two B3+ atoms. In the eighth O2- site, O2- is bonded in a bent 120 degrees geometry to one B3+ and one H1+ atom. In the ninth O2- site, O2- is bonded in a bent 120 degrees geometry to one B3+ and one H1+ atom. In the tenth O2- site, O2- is bonded in a distorted bent 120 degrees geometry to one B3+ and one H1+ atom. In the eleventh O2- site, O2- is bonded in a distorted water-like geometry to one Na1+ and two H1+ atoms. In the twelfth O2- site, O2- is bonded in a water-like geometry to one Na1+ and two H1+ atoms. In the thirteenth O2- site, O2- is bonded in a distorted water-like geometry to two H1+ atoms. In the fourteenth O2- site, O2- is bonded in a distorted water-like geometry to one Na1+ and two H1+ atoms. In the fifteenth O2- site, O2- is bonded in a 1-coordinate geometry to one Na1+, one B3+, and two H1+ atoms. In the sixteenth O2- site, O2- is bonded in a distorted water-like geometry to one Na1+ and two H1+ atoms.

36 MATERIALS SCIENCE↗

HB-Line Anion Exchange Purification of AFS-2 Plutonium for MOX

Non-radioactive cerium (Ce) and radioactive plutonium (Pu) anion exchange column experiments using scaled HB-Line designs were performed to investigate the feasibility of using either gadolinium nitrate (Gd) or boric acid (B as H 3 BO 3 ) as a neutron poison in the H-Canyon dissolution process. Expected typical concentrations of probable impurities were tested and the removal of these impurities by a decontamination wash was measured. Impurity concentrations are compared to two specifications - designated as Column A or Column B (most restrictive) - proposed for plutonium oxide (PuO 2 ) product shipped to the Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF). Use of Gd as a neutron poison requires a larger volume of wash for the proposed Column A specification. Since boron (B) has a higher proposed specification and is more easily removed by washing, it appears to be the better candidate for use in the H-Canyon dissolution process. Some difficulty was observed in achieving the Column A specification due to the limited effectiveness that the wash step has in removing the residual B after ~4 BV's wash. However a combination of the experimental 10 BV's wash results and a calculated DF from the oxalate precipitation process yields an overall DF sufficient to meet the Column A specification. For those impurities (other than B) not removed by 10 BV's of wash, the impurity is either not expected to be present in the feedstock or process, or recommendations have been provided for improvement in the analytical detection/method or validation of calculated results. In summary, boron is recommended as the appropriate neutron poison for H-Canyon dissolution and impurities are expected to meet the Column A specification limits for oxide production in HB-Line.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

California GAMA Special Study: Stable isotopic composition of groundwater boron – Analytical method development

Boron is a ubiquitous dissolved constituent in natural waters due to its high solubility, natural occurrence in continental crust, and anthropogenic use in fertilizers, consumer products, and other non-natural sources. The two stable isotopes of boron, 10 B and 11 B (natural abundances ≈ 19.9 and ≈ 80.1 atom percent, respectively), undergo isotopic fractionation due to a variety of chemical processes related to boron speciation ( 10 B is preferentially incorporated into B(OH) 4 - versus B(OH) 3 , e.g. Byrne et al., 2006). The isotopic composition of dissolved boron in groundwater can be used to determine the source(s) of boron; this information can be used to infer the source(s) of other co-migrating contaminants (e.g. nitrate, pharmaceuticals, etc.). Boron behaves as a conservative element in groundwater and surface water systems (Barth, 2000), and the isotopic signature of boron is most useful in conjunction with other stable and radiogenic isotope systems (e.g. δ 18 O, δ 15 N, δ 13 C, 87 Sr/ 86 Sr; Tirez et al., 2010; Widory et al., 2004; Widory et al., 2005) to determine the source(s) of contaminants of interest. We present here a method for boron purification in natural water samples (groundwater, surface water, and seawater) by ion exchange chemistry and measurement of boron isotopic composition by MC-ICP-MS. These methods can be applied to samples with boron concentrations as low as 10 ppb with precision on δ 11 B measurements better than ± 1 ‰. We utilize boron isotopic measurements of boric acid, groundwater, and seawater standards to validate the methods. We also present boron isotopic measurements of San Diego County domestic well samples to demonstrate how these methods can be applied to any study of natural water samples.

07 ISOTOPE AND RADIATION SOURCES↗

Results From The Salt Disposition Project Next Generation Solvent Demonstration Plan

Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Solvent Hold Tank (SHT) samples were taken throughout the Next Generation Solvent (NGS) Demonstration Plan. These samples were analyzed and the results are reported. SHT: The solvent behaved as expected, with no bulk changes in the composition over time, with the exception of the TOA and TiDG. The TiDG depletion is higher than expected, and consideration must be taken on the required rate of replenishment. Monthly sampling of the SHT is warranted. If possible, additional SHT samples for TiDG analysis (only) would help SRNL refine the TiDG degradation model. CWT: The CWT samples show the expected behavior in terms of bulk chemistry. The 137Cs deposited into the CWT varies somewhat, but generally appears to be lower than during operations with the BOBCalix solvent. While a few minor organic components were noted to be present in the Preliminary sample, at this time these are thought to be artifacts of the sample preparation or may be due to the preceding solvent superwash. DSSHT: The DSSHT samples show the predicted bulk chemistry, although they point towards significant dilution at the front end of the Demonstration. The 137Cs levels in the DSSHT are much lower than during the BOBCalix operations, which is the expected observation. SEHT: The SEHT samples represent the most different output of all four of the outputs from MCU. While the bulk chemistry is as expected, something is causing the pH of the SEHT to be higher than what would be predicted from a pure stream of 0.01 M boric acid. There are several possible different reasons for this, and SRNL is in the process of investigating. Other than the pH issue, the SEHT is as predicted. In summary, the NGS Demonstration Plan samples indicate that the MCU system, with the Blend Solvent, is operating as expected. The only issue of concern regards the pH of the SEHT, and SRNL is in the process of investigating this. SRNL results support the transition to routine operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced Severe Transient Analysis for Prevention Technical Program Plan

This document outlines the development of a high fidelity, best estimate nuclear power plant severe transient simulation capability that will complement or enhance the integral system codes historically used for licensing and analysis of severe accidents. As with other tools in the Risk Informed Safety Margin Characterization (RISMC) Toolkit, the ultimate user of Enhanced Severe Transient Analysis and Prevention (ESTAP) capability is the plant decision-maker; the deliverable to that customer is a modern, simulation-based safety analysis capability, applicable to a much broader class of safety issues than is traditional Light Water Reactor (LWR) licensing analysis. Currently, the RISMC pathway’s major emphasis is placed on developing RELAP-7, a next-generation safety analysis code, and on showing how to use RELAP-7 to analyze margin from a modern point of view: that is, by characterizing margin in terms of the probabilistic spectra of the “loads” applied to systems, structures, and components (SSCs), and the “capacity” of those SSCs to resist those loads without failing. The first objective of the ESTAP task, and the focus of one task of this effort, is to augment RELAP-7 analyses with user-selected multi-dimensional, multi-phase models of specific plant components to simulate complex phenomena that may lead to, or exacerbate, severe transients and core damage. Such phenomena include: coolant crossflow between PWR assemblies during a severe reactivity transient, stratified single or two-phase coolant flow in primary coolant piping, inhomogeneous mixing of emergency coolant water or boric acid with hot primary coolant, and water hammer. These are well-documented phenomena associated with plant transients but that are generally not captured in system codes. They are, however, generally limited to specific components, structures, and operating conditions. The second ESTAP task is to similarly augment a severe (post-core damage) accident integral analyses code with high fidelity simulations that would allow investigation of multi-dimensional, multi-phase containment phenomena that are only treated approximately in established codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydra-TH Extensions for Multispecies and Thermosolutal Convection

This report describes the Consortium for Advanced Simulation of Light Water Reactors (CASL) work conducted for completion of the Thermal Hydraulics Methods (THM) Level 3 Milestone THM.CFD.P11.02: Hydra-TH Extensions for Multispecies and Thermosolutal Convection. A critical requirement for modeling reactor thermal hydraulics is to account for species transport within the fluid. In particular, this capability is needed for modeling transport and diffusion of boric acid within water for emergency, reactivity-control scenarios. To support this need, a species transport capability has been implemented in Hydra-TH for binary systems (for example, solute within a solvent). A species transport equation is solved for the species (solute) mass fraction, and both thermal and solutal buoyancy effects are handled with specification of a Boussinesq body force. Species boundary conditions can be specified with a Dirichlet condition on mass fraction or a Neumann condition on diffusion flux. To enable enhanced species/fluid mixing in turbulent flow, the molecular diffusivity for the binary system is augmented with a turbulent diffusivity in the species transport calculation. The new capabilities are demonstrated by comparison of Hydra-TH calculations to the analytic solution for a thermosolutal convection problem, and excellent agreement is obtained.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nanocoating for High-efficiency Industrial Hydraulic and Tooling Systems

Characterization of the AlMgB14-based coatings revealed their semi-crystalline nature; as a single phase, AlMgB 14 appears amorphous. Combining this material with TiB2 through comminution of very fine-scale powders (~100 nm), produces a bulk solid that exceeds the hardness of its respective constituent phases. Through physical vapor deposition processing, the resulting nanocomposite coating combines the wear resistance characteristic of hard materials (e.g. the AlMgB 14 ) with a regenerating lubricant. Within the top layers (10-20 nm) of the nanocomposite coating, the same TiB2 phase used to enhance the strength and provide ductility to the otherwise brittle AlMgB 14 material reacts with available oxygen to form boron oxide. As the atoms of TiB 2 continue to react, layers of boric acid begin to form at the surface. This affords an exceptionally low coefficient of friction (as low as 0.02) to the coating. Physical vapor deposition processing parameters were evaluated and optimized during the project to minimize the difficulties common to transitioning a laboratory-scale process or technology to a salable product. Coating process times and temperatures, process gas flows and ramp rates, and a number of other adjustable parameters were optimized based on the results of testing and coating characterization. The overriding goal of all of these efforts was a repeatable coating process that yields the benefits observed in the laboratory, independent of the intended product or market.

36 MATERIALS SCIENCE↗

Characterization of Solids Deposited on the Modular Caustic-Side Solvent Extraction Unit (MCU) Strip Effluent (SE) Coalescer Media Removed in April 2015

On June 2015, Savannah River National Laboratory (SRNL) received a Strip Effluent (SE) coalescer (FLT-304) from MCU. That coalescer was first installed at MCU in late October 2014 and removed in April 2015. While processing approximately 48,700 gallons of strip solution, the pressure drop steadily increased linearly from 1 psi to near 16 psi (the administrative limit is 17 psi) with the total filtrate volume (2.1E-4 psi/gal of filtrate). The linear behavior is due to the combined effect of a constant deposition of material that starts from the closed-end to the mid-section of the coalescer reducing the available surface area of the coalescer for fluid passage (linearly with filtrate volume) and the formation of a secondary emulsion (water in NG-CSSX) on the fibers of the coalescer media. Both effects reduced the coalescer porosity by at least 13% (after processing 48,700 gallons). Before the coalescer was removed, it was flushed with a 10 mM boric acid solution to reduce the dose level. To determine the nature of the deposited material, a physical and chemical analysis of the coalescer was conducted. Characterization of this coalescer revealed the adsorption of organic containing amines (secondary amides and primary amines), TiDG, degraded modifier (with no hydroxyl group), MaxCalix, and oxidized hydrocarbon (possibly from Isopar™L or from lubricant used at MCU) onto the coalescer media. The amide and amines are possibly from the decomposition of the suppressor (TiDG). The modifier and MaxCalix were the largest components of the deposited organic material, as determined from leaching the coalescer with dichloromethane. Both the Fourier-Transformed Infrared (FTIR) and Fourier-Transformed Hydrogen Nuclear Magnetic Resonance (FT-HNMR) results indicated that some of the modifier was degraded (missing their OH groups). The modifier was observed everywhere in the examined coalescer pieces (FTIR), while the TiDG and its decomposition products were observed at the entrance discs of the coalescer. A solvent trim (a cocktail of solvent components with a high concentration of modifier) was added to the solvent on 2/22/2015. It is believed that the trim did not mix completely with the solvent and that it was subsequently spread around the MCU components including the coalescers, where it may have deposited. Chronologically, the modifier, the TiDG’s decomposition products and silicates deposited on the entrance discs first and after the pressure drop increased significantly, parts of the coalescer media detached itself from the central porous steel mandrel and a significant amount of steel debris, mercury, titanium, and additional aluminum and silicates deposited on the coalescer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Executive Summary: Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room

Under the United States Department of Energy Light Water Sustainability Program (LWRS), Idaho National Laboratory (INL) is collaborating with Palo Verde Generating Station (PVGS) to support human factors engineering efforts in the modernization of PVNGS’ radiological waste system (LRS) control room. The studies proposed and/or conducted by INL are designed to address the inconsistency between different human factors standards, guidance, and conventions. Guidance such as NUREG-0700 leave much of the information open to interpretation. INL will identify whether maintaining a design that is consistent with population stereotypes actually enhances performance, or whether there are alternative designs that yield performance that is better than the designs that maintain those stereotypes. The overall design concept for the LRS workstation includes system overview displays for the Evaporator system and the Boric Acid Concentrator system. A third display contains overview information for the rest of the LRS. The forth display contains alarm information. Each display will be presented on one of four monitors in the control room. The system overview displays contain embedded controls for valves and pumps, mini-trends, and micro-trends. The mini-trends present data for the controllers and contain alarm set point information as well as trending. All other relevant system parameters are shown on micro-trends. The semi-dull screen approach utilized present dynamic data in green, active components are white (gray when closed or off). The product stream flow paths are indicated by different colors. Alarm states are presented in saturated red and selected components are indicated by bright blue. In addition to the micro task study described below, the INL researchers also conducted an evaluation of the semi-dull screen approach as well as an ergonomic evaluation of the suggested upgrades in the local control room. A detailed report of all INL’s activities related to the modernization of the LRS conducted between October 2016 and September 2017 are found in these two reports; • INL-EXT-17-43226, Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room, and • INL-EXT-17-43250, Evaluation of Control Room Interface Designs to Support Modernization in Nuclear Power Plants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the SRNL Studies of the MCU Strip Effluent Coalescers

Three potential causes of the strip effluent (SE) coalescer (SEC) failure were investigated: inorganic fouling, organic fouling, and biological fouling. From the analysis of the SEC and leachate samples from the SEC, there is no evidence that the fouling is caused by inorganic precipitates, solids, or salts. The analysis of the SEC shows the presence of organic material such as sec-butylphenol and Modifier (1-(2,2,3,3-Tetrafluoropropoxy)-3-(4-secbutylphenoxy)-2- propanol). The source of the sec-butylphenol would be from the decomposition of the Modifier in the solvent. The analysis of the SEC shows the presence of amide bonds that are likely from bacteria and other biological material. In addition, samples from the Strip Feed Tank (StFT) and the boric acid delivery tanker showed the presence of bacteria and other biological material. The most likely cause of the SEC fouling is biofouling by bacteria and other organisms that form a biofilm on the SEC fibers. The biofilm would sorb organic material in the feed to the SEC, and not readily release this material. The bacteria would use this trapped organic material to grow the biofilm, which would decrease the porosity of the SEC. The biofilm would thereby impede SEC operation through biofouling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PAL Experimental Report Form

We constructed the first simultaneous dark- and bright-field X-ray microscope in this experiment, coupling it to simultaneous measurements of the wide-angle Xray diffraction, and the XFEL pulse intensity and energy spectrum on each shot. This experiment established proof of concept for this new advanced measurement technique and demonstrated DFXM at an XFEL for the first time. Within this complex experiment, we also acquired data that advanced our research goals within materials science and mathematics. These included: A preliminary study of how local effects reduce the X-ray damage threshold in diamond; A preliminary study of how X-ray radiation imparts heat into materials based on irreversible phase transitions that occur in boric acid with increasing temperature (based on hydration); A study of X-ray radiation damage from ultrafast thermal cycling and nonthermal melting in bismuth selenide; We also began developing software to automate alignment of compound refractive lenses (CRLs) using stochastic Nelder-Mead optimization methods. This work will expedite and improve the accuracy of alignments for many future experiments using CRLs.

36 MATERIALS SCIENCE↗

Low Activity Waste Tuning Feed Material Testing VSL-18R4350-1 (Final Report)

High level waste (HLW) from the Hanford tank farms will be retrieved and transferred to the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The waste will be pretreated to separate the soluble chemical salts (mostly sodium nitrate/nitrite and sodium hydroxide) from the bulk of the radioactive materials. This decontaminated salt solution is the low activity waste (LAW) stream which constitutes most of the total waste volume. The remaining HLW contains most of the radioactive materials but a fraction of the volume. Each of these waste streams is directed to an independent processing facility where the waste is mixed with glass forming chemicals (mostly silica and borax or boric acid) and fed into the melters for stabilization by conversion into glass. The molten glass is poured into stainless steel containers to produce packages for disposal: local shallow burial for the LAW containers and a future geologic repository for the HLW containers. The LAW facility melters produce significant quantities of NOx-laden off-gas that require abatement in accordance with 10 CFR 830 and air emission requirements. The NOx emissions also pose a safety risk. The LAW facility commissioning sequence requires that the melters be operated and process control loops tuned prior to introducing waste or waste feed materials that produce NOx. Therefore, a temporary or permanent system architecture is needed that provides a feed supply to the melters for the purpose of melter testing and off-gas tuning that does not result in the production of significantly hazardous off-gas products.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Business Case Analysis for Artificial Intelligence-Large Language Model Technology Integration

AI-assisted processes are expected to enhance operational efficiency and improve decision-making, supporting the long-term economic viability of nuclear power plants. However, detailed business analyses of AI-generated cost savings are rarely performed. Given the recent industry interest in Large Language Model (LLM), the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program has conducted a comprehensive business case analysis of LLM Artificial Intelligence (AI) implementation in nuclear plant engineering workflows. The research employed three complementary business case approaches to evaluate impact of an LLM, using three representative engineering processes as use-cases: Boric Acid Corrosion (BAC) Evaluations, Maintenance Rule Evaluations, and 10 CFR 50.59 Screenings. Through detailed workload analyses and structured interviews, the study quantified significant efficiency improvements ranging from 11% to 59% across these processes. The research further considers how these efficiency gains could translate into tangible reliability improvements through enhanced engineering capacity. Analysis of historical plant trip data indicates that enabling engineers to focus on proactive reliability activities could provide substantial financial benefits through avoided outages, potentially generating greater value than the direct efficiency improvements alone. By documenting successful applications, implementation challenges, and strategic opportunities, this research provides nuclear utilities with a practical framework for evaluating the value of AI technology to support long-term operations through advanced digital technologies.

97 MATHEMATICS AND COMPUTING↗

Caustic-Side Solvent-Extraction Modeling for Hanford Interim Pretreatment System

The purpose of this work is to examine the applicability of the Caustic-Side Solvent Extraction (CSSX) process for the removal of cesium from Hanford tank-waste supernatant solutions in support of the Hanford Interim Pretreatment System (IPS). The Hanford waste types are more challenging than those at the Savannah River Site (SRS) in that they contain significantly higher levels of potassium, the chief competing ion in the extraction of cesium. It was confirmed by use of the CSSX model that the higher levels of potassium depress the cesium distribution ratio (DCs), as validated by measurement of DCs values for four of eight specified Hanford waste-simulant compositions. The model predictions were good to an apparent standard error of ±11%. It is concluded from batch distribution experiments, physical-property measurements, equilibrium modeling, flowsheet calculations, and contactor sizing that the CSSX process as currently employed for cesium removal from alkaline salt waste at the SRS is capable of treating similar Hanford tank feeds. For the most challenging waste composition, 41 stages would be required to provide a cesium decontamination factor (DF) of 5000 and a concentration factor (CF) of 5. Commercial contacting equipment with rotor diameters of 10 in. for extraction and 5 in. for stripping should have the capacity to meet throughput requirements, but testing will be required to confirm that the needed efficiency and hydraulic performance are actually obtainable. Markedly improved flowsheet performance was calculated for a new solvent formulation employing the more soluble cesium extractant BEHBCalixC6 used with alternative scrub and strip solutions, respectively 0.1 M NaOH and 10 mM boric acid. The improved system can meet minimum requirements (DF = 5000 and CF = 5) with 17 stages or more ambitious goals (DF = 40,000 and CF = 15) with 19 stages. Potential benefits of further research and development are identified that would lead to reduced costs, greater adaptability of the process to DOE alkaline salt wastes, and greater readiness for implementation. Such benefits accrue from optimal sizing of centrifugal contactors for application of the CSSX process for the IPS; more accurate modeling of cesium extraction with greater flexibility and applicability to a variety of feeds and flowsheet conditions; and further improving and optimizing the alternative CSSX solvent and scrub/strip system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RHEOLOGICAL AND ELEMENTAL ANALYSES OF SIMULANT SB5 SLURRY MIX EVAPORATOR-MELTER FEED TANK SLURRIES

The Defense Waste Processing Facility (DWPF) will complete Sludge Batch 5 (SB5) processing in fiscal year 2010. DWPF has experienced multiple feed stoppages for the SB5 Melter Feed Tank (MFT) due to clogs. Melter throughput is decreased not only due to the feed stoppage, but also because dilution of the feed by addition of prime water (about 60 gallons), which is required to restart the MFT pump. SB5 conditions are different from previous batches in one respect: pH of the Slurry Mix Evaporator (SME) product (9 for SB5 vs. 7 for SB4). Since a higher pH could cause gel formation, due in part to greater leaching from the glass frit into the supernate, SRNL studies were undertaken to check this hypothesis. The clogging issue is addressed by this simulant work, requested via a technical task request from DWPF. The experiments were conducted at Aiken County Technology Laboratory (ACTL) wherein a non-radioactive simulant consisting of SB5 Sludge Receipt and Adjustment Tank (SRAT) product simulant and frit was subjected to a 30 hour SME cycle at two different pH levels, 7.5 and 10; the boiling was completed over a period of six days. Rheology and supernate elemental composition measurements were conducted. The caustic run exhibited foaming once, after 30 minutes of boiling. It was expected that caustic boiling would exhibit a greater leaching rate, which could cause formation of sodium aluminosilicate and would allow gel formation to increase the thickness of the simulant. Xray Diffraction (XRD) measurements of the simulant did not detect crystalline sodium aluminosilicate, a possible gel formation species. Instead, it was observed that caustic conditions, but not necessarily boiling time, induced greater thickness, but lowered the leach rate. Leaching consists of the formation of metal hydroxides from the oxides, formation of boric acid from the boron oxide, and dissolution of SiO{sub 2}, the major frit component. It is likely that the observed precipitation of Mg(OH){sub 2} and Mn(OH){sub 2} caused the increase in yield stress. The low pH run exhibited as much as an order of magnitude greater B and Li (frit components) leachate concentrations in the supernate. At high pH a decrease of B leaching was found and this was attributed to adsorption onto Mg(OH){sub 2}. A second leaching experiment was performed without any sludge to deconvolute the leach rate behavior of Frit 418 from those of the SB5 sludge-Frit 418 system. At high pH, the sludgeless system demonstrated very fast leaching of all the frit components, primarily due to fast dissolution of the main component, silica, by hydroxide anion; various semiconductor studies have established this reactivity. Overall, the frit-water system exhibited greater leaching from a factor two to almost three orders of magnitude (varying by conditions and species). The slower leaching of the sludge system is possibly due to a greater ionic strength or smaller driving force. Another possible reason is a physical effect, coating of the frit particles with sludge; this would increase the mass transfer resistance to leaching. Based on this study, the cause of clogs in the melter feed loop is still unknown. A possible explanation is that the SME product, like the simulant, is too thin and could contribute to a loss of two-phase flow which could cause plugging of a restricted and poorly mixed zone like the melter feed loop. This is feasible since a previous study of a slurry showed an increase in resistance to flow at lower flow rates. Testing with a radioactive SME sample is underway and should help understand this potential mechanism.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modified carbon fibers to improve composite properties

Thin coatings, 5 to 10 wt. percent, were applied to PAN-based carbon fibers. These coatings were intended to make the carbon fibers less electrically conductive or to cause fibers to stick together when a carbon fiber/epoxy composite burned. The effectiveness of the coatings in these regards was evaluated in burn tests with a test rig designed to simulate burning, impact and wind conditions which might release carbon fibers. The effect of the coatings on fiber and composite properties and handling was also investigated. Attempts at sizing carbon fibers with silicon dioxide, silicon carbide and boron nitride meet with varying degrees of success; however, none of these materials provided an electrically nonconductive coating. Coatings intended to stick carbon fibers together after a composite burned were sodium silicate, silica gel, ethyl silicate, boric acid and ammonium borate. Of these, only the sodium silicate and silica gel provided any sticking together of fibers. The amount of sticking was insufficient to achieve the desired objectives.

Shepler, R. E.↗