At least 163 records · Page 9

Jovian probe wake flowfield

The base heating problem in the Jovian probe was examined. The entire wake flowfield is defined to calculate the radiative heating to the base region of the Jovian probe. Engineering tools for calculating the probe's wake flowfield are developed. The near and far viscous and inviscid flowfields for three entry conditions are calculated. The flowfields include pressure, temperature, and species concentration for radiation analysis. A mathematical model used in the calculations is described. The results obtained indicate that temperatures in the Jovian probe range from 4,000 to 10,00 K and pressures range from 10 to 1,000 times the free stream value.

Engel, C. D.↗

In-Flight Thermal Performance of the OCO-2 Instrument

The Orbiting Carbon Observatory-2 (OCO-2), launched on July 2, 2014, continues to operate nominally after successfully completing its primary mission of two years in space. It is hoped that, following a Senior Review and proposal phase, NASA will fund a two year extended mission, which would start in June 2017. The thermal design provides three temperature zones required by the instrument, specifically at 120 K, 267 K and 297 K. A single-stage pulse tube cryocooler provides refrigeration to three focal plane arrays to 120 K, via a high conductance flexible thermal strap. A variable conductance heat pipe (VCHP) based heat rejection system transports waste heat from the instrument, located inside the spacecraft, to the space-viewing radiators, providing tight temperature control of the spectrometer optics to 267 K, and maintains the electronics and cryocooler at 297 K. Soon after entering the A-Train on August 3, 2014, the optics and focal planes were cooled to their operating temperatures. Ice contamination of the cryogenic surfaces led to increased cryocooler loads and drove the need for two focal plane decontamination cycles between September 2014 and October 2014. A decrease in the radiometric gain of the O2 A-Band channel led to five additional focal plane decontamination cycles, between January 2015 and February 2017, and is now the primary driver of decontamination cycles. This paper provides a general overview of the thermal and cryogenic system design and reviews the inflight thermal performance for the mission.

Na-Nakornpanom, Arthur↗

Evaluation of dispersion strengthened nickel-base alloy heat shields for space shuttle application

The results obtained in a program to evaluate dispersion-strengthened nickel-base alloys for use in a metallic radiative thermal protection system operating at surface temperatures to 1477 K for the space shuttle were presented. Vehicle environments having critical effects on the thermal protection system are defined; TD Ni-20Cr characteristics of material used in the current study are compared with previous results; cyclic load, temperature, and pressure effects on sheet material residual strength are investigated; the effects of braze reinforcement in improving the efficiency of spotwelded joints are evaluated; parametric studies of metallic radiative thermal protection systems are reported; and the design, instrumentation, and testing of full scale subsize heat shield panels in two configurations are described. Initial tests of full scale subsize panels included simulated meteoroid impact tests, simulated entry flight aerodynamic heating, programmed differential pressure loads and temperatures simulating mission conditions, and acoustic tests simulating sound levels experienced during boost flight.

Johnson, R., Jr.↗

Technology Activities in the Aerodynamics and Hydrodynamics of Propulsion Elements at MSFC (NASA)

This presentation discusses the work towards a second generation reusable launch vehicle (RLV). The goals of the second generation RLV program are reviewed. These include cost, safety, and propulsion advances. The Fluid dynamics technologies under development are discussed. These include the altitude compensating nozzle technology, the Aerospike plume induced base heating, the inducer testing technology. Pictures of altitude compensating nozzles Aerospike Plume Induced Base Heating results and Inducer testing technologies are included. Further goals of the program are to improve the methodology for optimizing design of the injectors, to improve the optimization of the turbopump and improvement of the methodology to analyze the engine performance. This presentation consists of outline view slides

Garcia, Roberto↗

Evaluation of a Passive Heat Exchanger Based Cooling System for Fuel Cell Applications

Fuel cell cooling is conventionally performed with an actively controlled, dedicated coolant loop that exchanges heat with a separate external cooling loop. To simplify this system the concept of directly cooling a fuel cell utilizing a coolant loop with a regenerative heat exchanger to preheat the coolant entering the fuel cell with the coolant exiting the fuel cell was analyzed. The preheating is necessary to minimize the temperature difference across the fuel cell stack. This type of coolant system would minimize the controls needed on the coolant loop and provide a mostly passive means of cooling the fuel cell. The results indicate that an operating temperature of near or greater than 70 C is achievable with a heat exchanger effectiveness of around 90 percent. Of the heat exchanger types evaluated with the same type of fluid on the hot and cold side, a counter flow type heat exchanger would be required which has the possibility of achieving the required effectiveness. The number of heat transfer units required by the heat exchanger would be around 9 or greater. Although the analysis indicates the concept is feasible, the heat exchanger design would need to be developed and optimized for a specific fuel cell operation in order to achieve the high effectiveness value required.

Colozza, Anthony J.↗

Code Validation Study for Base Flows

New and old rocket launch concepts recommend the clustering of motors for improved lift capability. The flowfield of the base region of the rocket is very complex and can contain high temperature plume gases. These hot gases can cause catastrophic problems if not adequately designed for. To assess the base region characteristics, advanced computational fluid dynamics (CFD) is being used. As a precursor to these calculations the CFD code requires validation on base flows. The primary objective of this code validation study was to establish a high level of confidence in predicting base flows with the USA CFD code. USA has been extensively validated for fundamental flows and other applications. However, base heating flows have a number of unique characteristics so it was necessary to extend the existing validation for this class of problems. In preparation for the planned NLS 1.5 Stage base heating analysis, six case sets were studied to extend the USA code validation data base. This presentation gives a cursive review of three of these cases. The cases presented include a 2D axi-symmetric study, a 3D real nozzle study, and a 3D multi-species study. The results of all the studies show good general agreement with data with no adjustments to the base numerical algorithms or physical models in the code. The study proved the capability of the USA code for modeling base flows within the accuracy of available data.

Ascoli, Edward P.↗

A hybrid method to evaluate the life cycle climate performance of heat pumps

Heat pumps have a significant impact on the climate, and numerous studies exist discussing the environmental impact of heat pumps quantitatively. Life Cycle Climate Performance (LCCP) is a widely accepted metric and can evaluate the carbon footprint of heat pumps from cradle to grave. LCCP calculation typically requires inputs like annual energy consumption, the material used, refrigerant type, and charge level, which are usually the intermediate or final results from heat pump simulation tools. Thus, a platform linking the heat pump simulation software, local weather conditions, and LCCP evaluation tool can simplify the heat pump design process, especially for complicated systems. This paper presents an LCCP evaluation tool accessing the outputs from the DOE Heat Pump Design Model and the building loads and temperature bin data from AHRI standard 210/240. As for case studies, this paper investigates the LCCP values and life cycle electricity costs (LCEC) of a given cooling-based heat pump with R410A in five typical US cities. In conclusion, this cooling-based heat pump has the highest LCCP value at Chicago and lowest LCCP value at Seattle. In contrast, the heat pump has the highest LCEC at Seattle and the lowest LCEC at Miami. As a future work, a more comprehensive carbon emission and cost analysis of heat pump systems will be conducted through all major cities around the world.

Shen, Bo↗

Options For Large-Scale Installation of Individual Heat Substations Based on International Best Practices

The purpose of this report is to provide recommendations for actions Ukraine could take to implement large-scale installation of IHSs as part of comprehensive district heating reform. The report discusses the importance of IHS in the district heating sector, then presents several case studies of approaches that European countries have taken to facilitate large-scale IHS installation in multi-apartment buildings. These case studies focus on the ownership and financing of IHS, as there are different models for how this can be done (the DH company can make the investments and recover the costs through the tariff, or building residents can make the investments themselves). They also include details on the approval process and technical specifications, as these can add additional barriers and time to the installation process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Woven Thermal Protection System Based Heat-shield for Extreme Entry Environments Technology (HEEET)

NASA's future robotic missions utilizing an entry system into Venus and the outer planets, namely, Saturn, Uranus, Neptune, result in extremely severe entry conditions that exceed the capabilities of state of the art low to mid density ablators such as PICA or Avcoat. Therefore mission planners typically assume the use of a fully dense carbon phenolic heat shield similar to what was flown on Pioneer Venus and Galileo. Carbon phenolic (CP) is a robust TPS material however its high density and relatively high thermal conductivity constrain mission planners to steep entries, with high heat fluxes and pressures and short entry durations, in order for CP to be feasible from a mass perspective. The high entry conditions pose challenges for certification in existing ground based test facilities and the longer-­‐term sustainability of CP will continue to pose challenges. In 2012 the Game Changing Development Program (GCDP) in NASA's Space Technology Mission Directorate funded NASA ARC to investigate the feasibility of a Woven Thermal Protection System (WTPS) to meet the needs of NASA's most challenging entry missions. This project was highly successful demonstrating that a Woven TPS solution compares favorably to CP in performance in simulated reentry environments and provides the opportunity to manufacture graded materials that should result in overall reduced mass solutions and enable a much broader set of missions than does CP. Building off the success of the WTPS project GCDP has funded a follow on project to further mature and scale up the WTPS concept for insertion into future NASA robotic missions. The matured WTPS will address the CP concerns associated with ground based test limitations and sustainability. This presentation will briefly discuss results from the WTPS Project and the plans for WTPS maturation into a heat-­‐shield for extreme entry environment.

Chinnapongse, Ronald↗

Woven Thermal Protection System Based Heat-shield for Extreme Entry Environments Technology (HEEET)

NASA's future robotic missions utilizing an entry system into Venus and the outer planets, namely, Saturn, Uranus, Neptune, result in extremely high entry conditions that exceed the capabilities of state of the art low to mid density ablators such as PICA or Avcoat. Therefore mission planners typically assume the use of a fully dense carbon phenolic heat shield similar to what was flown on Pioneer Venus and Galileo. Carbon phenolic is a robust TPS material however its high density and relatively high thermal conductivity constrain mission planners to steep entries, with high heat fluxes and pressures and short entry durations, in order for CP to be feasible from a mass perspective. The high entry conditions pose challenges for certification in existing ground based test facilities and the longer‐term sustainability of CP will continue to pose challenges. In 2012 the Game Changing Development Program (GCDP) in NASA's Space Technology Mission Directorate funded NASA ARC to investigate the feasibility of a Woven Thermal Protection System (WTPS) to meet the needs of NASA's most challenging entry missions. This project was highly successful demonstrating that a Woven TPS solution compares favorably to CP in performance in simulated reentry environments and provides the opportunity to manufacture graded materials that should result in overall reduced mass solutions and enable a much broader set of missions than does CP. Building off the success of the WTPS project GCDP has funded a follow on project to further mature and scale up the WTPS concept for insertion into future NASA robotic missions. The matured WTPS will address the CP concerns associated with ground based test limitations and sustainability. This presentation will briefly discuss results from the WTPS Project and the plans for WTPS maturation into a heat‐shield for extreme entry environment.

Ellerby, Donald↗

Heat Transfer of an Integrated Counterflow Ceramic Heat Exchanger

The ceramic-based heat exchanger is one of the leading contenders for high-efficiency concentrating solar power plants using a molten salt heat transfer fluid and a supercritical carbon dioxide Brayton power cycle operating at temperatures above 700 °C due to the excellent resistance of ceramics to corrosion, oxidation, erosion, creep, and fouling. In the present study, the thermal performance of a ceramic silicon carbide prototype heat exchanger, with semi-elliptical heat transfer channels, integrated header channels, and a counterflow configuration fabricated by using binder jetting additive manufacturing, was experimentally investigated. Experimental heat transfer tests of the prototype were conducted at high temperatures and under various test fluid flow rates and inlet temperatures. The experimental heat transfer rates compared favorably with simulation predictions.

Yu, Wenhua (ORCID:0000000219457014)↗

Shuttle Upgrade Program: Tile TPS

One of the areas where the thermal protection system on the Space Shuttle Orbiter could be improved is the RSI (Reusable Surface Insulation) tile. The improvement would be in damage resistance that would reduce the resultant maintenance and inspection required. It has performed very well in every other aspect. Improving the system's damage resistance has been the subject of much research over the past several years. One of the results of that research was a new system developed for damage prone areas on the orbiter (i.e., base heat shield). That system, designated as TUFI, Toughened Uni-Piece Fibrous Insulation, was successfully demonstrated as an experiment on the Orbiter and is now baselined for the base heat shield. This paper describes the results of a current research program to further improve the TUFI tile system, thus making it applicable to more areas on the orbiter. The way to remove the current limitations of the TUFI system (i.e., weight or thermal conductivity differences between it and the baseline tile (LI-900)) is to improve the characteristics of LI-900 or AETB-8. Specifically this paper describes the results of two efforts. The first shows performance data of an improved LI-900 system involving the application of TUFI and the second describes data that shows a reduced difference in thermal conductivity between the advanced TUFI substrate (AETB-8) now used on the orbiter and LI-900.

Daniel B Leiser↗

Ares I-X Ascent Base Environments

Plume induced base heating environments were measured during the flight of the NASA Constellation Ares I-X developmental launch vehicle, successfully flown on October 28, 2009. The Ares IX first stage is a four segment Space Shuttle derived booster with base consisting of a flared aft skirt, deceleration and tumble motors, and a thermal curtain surrounding the first stage 7.2 area ratio nozzle. Developmental Flight Instrumentation (DFI) consisted of radiometers, calorimeters, pressure transducers and gas temperature probes installed on the aft skirt and nozzle to measure the base environments. In addition, thermocouples were also installed between the layers of the flexible thermal curtain to provide insight into the curtain response to the base environments and to assist in understanding curtain failure during reentry. Plume radiation environment predictions were generated by the Reverse Monte Carlo (RMC) code and the convective base heating predictions utilized heritage MSFC empirical methods. These predictions were compared to the DFI data and results from the flight videography. Radiation predictions agreed with the flight measured data early in flight but gauge failures prevented high altitude comparisons. The convective environment comparisons demonstrated the need to improve the prediction methodology; particularly for low altitude, local plume recirculation. The convective comparisons showed relatively good agreement at altitudes greater than 50,000 feet.

Mobley, B. L.↗

Research Study: Space Shuttle Main Engine Plume Flowfield Model

The initial research effort was an in-depth analysis of the shuttle main engine plumes in an effort to improve the flowfield model and to enhance shuttle base heating equipment predictions during ascent. A prediction methodology code was developed incorporating the improved plume model into a predictive tool which could consider different trajectoreis and engine perfromance variables. Various plume flow model improvement studies were ongoing at the time of the 51-L accident. Since that time, base heating and plume methodology improvements have continued as part of the overall emphasis on Shuttle design assurance before resuming flight schedule.

Bender, Robert L.↗