Search NASA⌕ Search

SEARCH · Search NASA

Results for “Base heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

FY23 Progress Report on Viscosity and Thermal Conductivity Measurements of Molten Salts

As presented in this report, thermal conductivity and viscosity measurements were performed on key chloride pseudo-binary molten salt systems of relevance to molten salt reactor developers. Thermal conductivity measurements were conducted with a variable gap technique, in which a known heat flux is driven across a molten salt specimen and the temperature difference is measured, allowing calculation of the thermal conductivity. This is achieved by establishing a small gap between the bottom of a cylindrical inner containment, which houses electrical heating elements, and an outer containment, which houses cooling channels; the gap size can be varied by compression of a formed bellows. A new calibration scheme was developed herein, involving a correction factor to the heat flux based on He measurements at various temperatures. Furthermore, the data processing methodology was improved to minimize the impact of radiative heat transfer in the calculation of salt specimen thermal conductivity from the temperature difference measurements. Viscosity measurements were conducted with a rolling ball viscometer, in which a ball rolls some known distance in an angled tubular crucible, and the terminal velocity can be used to calculate the viscosity of the salt. The measurement can be performed in a quartz crucible, with which a standard camera can be used to track the ball, or in a metal crucible, with which x-ray radiography is required to track the ball. A new custom x-ray system was made and dedicated to the rolling ball viscometer to enable high throughput automated measurements with salts which require containment with metal. Both systems have been integrated with a ventilation stack which allows for off-gassing of radioactive material, enabling future measurements with U-bearing salts. The thermal conductivity measurements performed herein were with NaCl-KCl (44 mol% NaCl). This salt system was measured in the previous fiscal year, however the thermal conductivity values obtained were comparatively low, and so the system was remeasured with the aforementioned calibration scheme and improved post-processing techniques. The newly obtained thermal conductivity values for NaCl-KCl (44 mol% NaCl) indicate good agreement with kinetic theory and ab-initio models (within 5–10 %). The viscosity measurements performed herein were with three different compositions of NaCl-KCl: 75, 50, and 25 mol% NaCl; a new calibration scheme was applied to account for variable flow effects in the laminar regime. The results show reasonable agreement with literature (5–20 %, depending on the temperature, composition, and study); however, literature values are likely higher than true values based on pure end-member measurements performed in the comparative studies. The measurements conducted herein do show a trend such that viscosity increases with increasing NaCl concentration, which agrees well with one of two comparative studies. In general, the measurements conducted herein gives confidence in the capability to use these systems to accurately measure thermal conductivity and viscosity of actinide-bearing salts within the next fiscal year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗

Fast-airflow tumble clothes dryer with small thermoelectric heat pump: Experimental evaluation

Residential clothes drying accounts for about 5% of the total residential-sector energy consumption in the United States. Most dryers use electric resistance heaters to dry clothes and have low efficiencies. Higher-efficiency dryers that use vapor compression heat pumps are expensive and complex and have not gained a large market share in the United States. A novel tumble clothes dryer using a small thermoelectric heat pump with faster airflow than typical dryers is presented in this work. The benchtop performance of the thermoelectric heat pump and high-speed blower are presented, and the development of the prototype dryer is described. The dryer was tested for efficiency and dry time for a range of airflow rates and applied currents to the thermoelectric heat pump. The combined efficiency factor was 5.09–6.29 lb BDW /kWh (specific moisture extraction rate of 1.23–1.53 kg w /kWh) with 100–138 min dry times for these tests. The measured efficiency was 36 %–68 % greater than the minimum efficiency standard in the United States, and compared with vapor compression heat pump–based clothes dryers, the prototype dryer had less expensive, less complex components and did not use refrigerants. Finally, the performance of this small thermoelectric heat pump clothes dryer is also compared with previous iterations of the thermoelectric tumble clothes dryer described in the literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lower Urban Humidity Moderates Outdoor Heat Stress

Abstract Surface temperature is often used to examine heat exposure in multi‐city studies and for informing urban heat mitigation efforts due to scarcity of urban air temperature measurements. Cities also have lower relative humidity, traditionally not accounted for in large‐scale observational urban heat risk assessments. Here, using crowdsourced measurements from over 40,000 weather stations in ≈600 urban clusters in Europe, we show the moderating effect of this urbanization‐induced humidity reduction on outdoor heat stress during the 2019 heatwave. We demonstrate that daytime differences in heat index between urban clusters and their surroundings are weak, and associations of this urban‐rural difference with background climate, generally examined from the surface temperature perspective, are diminished due to moisture feedbacks. We also examine the spatial variability of surface temperature, air temperature, and heat index within these clusters—relevant for detecting hotspots and potential disparities in heat exposure—and find that surface temperature is a poor proxy for the intra‐urban distribution of heat index during daytime. Finally, urban vegetation shows much weaker (∼1/6th as strong) associations with heat index than with surface temperature, which has broad implications for optimizing urban heat stress mitigation strategies. These findings are valid for operational metrics of heat stress for shaded conditions (apparent temperature and humidex), thermodynamic proxies (wet‐bulb temperature), and empirical heat indices. Based on this large‐scale empirical evidence, surface temperature, used due to the lack of better alternatives, may not be suitable for accurately informing heat mitigation strategies within and across cities, necessitating more urban‐scale observations and better urban‐resolving models.

54 ENVIRONMENTAL SCIENCES↗

Long Term Per-Component Power and Thermal Measurements of the OLCF Summit System

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide a dataset that records the long-term power and thermal behavior of the 200PF pre-exascale supercomputer at the Oak Ridge Leadership Computing Facility (OLCF), Summit. This system is an IBM AC922 based system that has 9,252 IBM Power9 CPUs and 27,756 Nvidia V100 GPUs and can consume up to 13MW power at peak. Heat removal is performed using medium temperature direct liquid cooling and rear-door heat exchanger based secondary cooling loop. Originally extracted from a high-resolution (1Hz) per-component (GPUs, CPUs) measurements from the system, we primarily provide a dataset that has 10-second and 1-minute mean power and thermal measurements selected from five month-long segments over the course of 2020 (January and August), 2021 (February and August), and 2022 (January). For convenience, we also provide various sub datasets randomly sampled from the time and space (hosts) of the cluster. Further details and example code for analysis can be found in the following GitHub repository: https://github.com/at-aaims/summit_power_and_thermal_data

97 MATHEMATICS AND COMPUTING↗

Phenomena Identification and Ranking Table (PIRT) for Heat Pipes

This Phenomena Identification and Ranking Table (PIRT) report provides an evaluation of key phenomena affecting the performance and operational regimes of heat pipes, particularly in the context of heat pipe microreactors (HPMRs). Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in the heat pipe, including phase change, turbulent transition, and compressibility effects, among others, there is high uncertainty in identifying and ranking the important phenomena affecting the operation of heat pipes and the current knowledge for their modeling and simulation and experimental measurements and instrumentation. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. The report analyzes phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics, discussing challenges and future research directions for improving their modeling and simulation and experimental measurements. Additionally, the report addresses phenomena with low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geysering, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. This comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Bio-inspired alula-based winglet design for enhanced heat transfer in high temperature fin-and-tube heat exchangers

Fin-and-tube heat exchangers (FTHEs) are widely used for high-temperature flue-gas heat recovery, but their performance is often limited by wake regions and non-uniform fin-surface temperatures. This study proposes and numerically evaluates four bio-inspired longitudinal vortex generator (VG) configurations in a high-temperature FTHE with flue-gas inlet temperature ∼1230 K: double-delta, curved double-delta, alula, and a new curved-alula geometry. The reference fin is not hydraulically plain; it already incorporates leading-edge separation columns and convex protrusions, so the alula-type winglets are assessed as downstream add-ons acting on a strongly disturbed flow. In a second step, perforations (one, two and three circular holes) are introduced into the curved-alula VGs to further tailor the flow field. Three-dimensional simulations with the Shear Stress Transpor (SST) $k - ω$ model, temperature-dependent flue-gas properties and conjugate conduction are carried out for gas-side Reynolds numbers $Re_g ≈ 8.0$ x $10^2 - 3.6$ x $10^3$ (mass flow rates 0.5 – 2.5 g/s), and the designs are compared in terms of surface heat flux, Nusselt number, friction factor and hydrothermal performance factor (HTPF). For this already-promoted fin, the additional downstream winglets provide moderate, incremental hydrothermal gains. At the highest Reynolds number, the best non-perforated design (curved-alula) increases surface heat flux from 1630.9 to 1794.7 kW/m² (∼ 10 % gain) and the Nusselt number from 227.6 to 242.6 (∼ 7 % gain), while the friction factor rises from 0.26 to about 0.30, yielding HTPF values close to unity (∼ 0.9 – 1.0). Introducing circular perforations into the curved-alula winglets acts mainly as a wake-bleeding refinement: the three-hole configuration provides a heat flux of 1824.7 kW/m² and a pressure drop of 127.9 Pa, with HTPF in the range ∼ 1.03 – 1.14 and a small (∼ 1 – 3 %) improvement over the solid curved-alula design. Flow-field analysis shows that the perforated curved-alula VGs shrink tube-wake regions, thin the thermal boundary layer and homogenize the fin-surface temperature (outlet-gas temperature ∼ 510 – 520 K and fin-surface temperature ∼ 420 – 421 K for the three-hole case). An optimal flue-gas mass flow rate of ∼ 1 g/s ($Re_g ≈ 1.5$ x $10^3$) is identified, beyond which additional heat-transfer gains are offset by rapidly increasing pressure losses. Overall, the results highlight that initial fin geometry and VG placement are as important as VG shape: alula-based winglets are expected to yield larger relative gains on simpler flat-fin layouts or when positioned closer to the fin leading edge and tube

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phenomena Identification and Ranking Table (PIRT) for heat pipes

Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in heat pipes, including capillary, phase change, turbulence, and compressibility effects, there are high uncertainties in the predictability of their operational regimes and performance. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. Additional analyses and discussion are provided for phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics. The discussions included the recognizing challenges and proposing future research directions for both modeling and simulation and experimental efforts. Additionally, the report addresses phenomena with medium importance and low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geyser boiling, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. In conclusion, this comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

The Relationship Between Dose Rate and Decay Heat for Spent Nuclear Fuel Casks

Decay heat and dose rate are two important limits used for determining the allowable contents of spent fuel (SNF) in dry storage systems and transportation packages. While the decay heat limit is used to maintain fuel cladding integrity and ensure retrievability, dose rates are used to demonstrate compliance with regulatory requirements on radiation protection. Because both dose rate and decay heat result from decay of radioisotopes in SNF, this study is an attempt to examine the relationship between dose rate and decay heat for a given cask design. Dose rates were evaluated for 198 cask configurations, that include various SNF system designs (e.g., storage, transfer, transport), SNF characteristics (e.g., fuel types, burnup, cooling time), and loading maps (e.g., uniform loading, zone loading), while a constant decay heat was maintained. The decay heat was calculated using US Nuclear Regulatory Commission (NRC) Regulatory Guide (RG) 3.54, Revision 2, and verified using ORIGEN sequence within SCALE code system. The ORIGEN outputs were used as source terms in the dose analysis using 198 different configurations. A computer script was developed to calculate the cooling time necessary to achieve a given decay heat for a given enrichment, assembly average burnup, assembly mass, and in-core history using a rootfinder algorithm. Initially the computer script was developed to provide cooling time and burnup calculations directly to the analysis of dose rates and decay heats, so a comparison between Used Nuclear Fuel-Storage Transportation and Disposal Analysis Resource Data System (UNF-ST&DARDS) results and RG3.54 data was made; results are included in the appendix to this document. However, an iterative approach was used to compute cooling time, and its accuracy did not depend on the results of the RG3.54r2 algorithm, although the algorithm was still used. The results of the evaluation presented herein clearly demonstrate that a given decay heat does not correspond to a unique dose rate for a variety of cask and package designs. There is no clear pattern to develop a correlation between decay heat and the source terms. Depending on burnup, enrichment, cask type, and loading pattern, dose rates varied for the exact same decay heat—in some cases by 400% for a given cask. For cases in which decay heat was held constant through selection of the appropriate cooling time, dose rates would decrease with increasing burnup, and in other cases, dose rates would increase. The large variation in dose rates for a constant decay heat indicates that casks loaded based on decay heat—that is allowing any burnup, cooling time, and enrichment combinations that yield the qualified decay heat limit(s) —cannot ensure that an Independent Spent Fuel Storage Installation or a spent fuel transportation package will meet the regulatory limits set forth by the respective regulations, i.e., 10 CFR 72 or 10 CFR 71.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decarbonizing Solvent Chemistry Through Microwave Processing [Abstract]

National Energy Technology Laboratory and Covestro LLC. will collaborate on a project titled, “Decarbonizing Solvent Chemistry Through Microwave Processing”, which was selected for funding by DOE’s Office of Energy Efficiency and Renewable Energy (EERE) Industrial Efficiency and Decarbonization Office (IEDO) FOA DE-EE0002997. The project aims to develop a microwave-based approach for low-heat aqueous-based industry-relevant reactions currently conducted using a conventional fossil-energy fueled hydrothermal reactor. The team has combined expertise in the areas of polymer production, microwave assisted reactions and scale-up, and life cycle analysis to perform the tasks proposed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗

Performance and durability of electrically conductive tape for shingled Si heterojunction technology cells

We report electrically conductive tape (ECT) was characterized and used to assemble shingled cell strings at low temperature to achieve high reliability Pb- and Ag-free interconnections. The volume resistivity for two considered ECTs are 0.13 ± 0.06 mΩ·cm and 0.47 ± 0.20 mΩ·cm and specific contact resistances, 6.85± 2.00 mΩ·cm 2 and 6.30 ± 0.37 mΩ·cm 2 using the emerging IEC 62788-8-1 Technical Specification for assessment of electrically conductive adhesives (ECA). Durability and performance of the technology in glass–glass mini modules were evaluated with temperature cycling, damp heat testing, and combined-accelerated stress testing (CAST). Through temperature cycling (-40°C to 85°C) applying five times the mini module short-circuit current in forward bias and in the multi climate CAST protocol, there was negligible degradation of fill factor after replacing connectors at the modules' cable leads; however, CAST resulted in short circuit current loss attributed to degradation in light collection by the cells, not the ECT. The IEC 61215-2 85°C, 85% relative humidity damp heat testing showed susceptibility of the HJT cells to effects of humidity in the electroluminescence intensity around the module perimeter that degraded power performance by 4% (relative). Contrasting the IEC 61215-2 qualification testing-based damp heat testing with CAST, factors such as the optical stress of CAST may precipitate the degradation of the modules whereas the humidity levels and duration of IEC 61215-2 damp heat testing may lead to excessive levels of humidity diffused into the modules, potentially resulting in degradation that is unrepresentative of the field.

14 SOLAR ENERGY↗

Magnetocaloric refrigerator

The invention is for an apparatus and method for a refrigerator and a heat pump based on the magnetocaloric effect (MCE) offering a simpler, lighter, robust, more compact, environmentally compatible, and energy efficient alternative to traditional vapor-compression devices. The subject magnetocaloric apparatus alternately exposes a magnetocaloric material to strong and weak magnetic field while switching heat to and from the material. Action of the heat switches is coordinated with the magnetic field strength to move heat up the thermal gradient. The invention may be practiced with multiple magnetocaloric stages to attain large differences in temperature. Key applications include thermal management of electronics, as well as industrial and home refrigeration, heating, and air conditioning. The invention offers a simpler, lighter, compact, and robust apparatus compared to magnetocaloric devices of prior art. Furthermore, the invention may be run in reverse as a thermodynamic engine, receiving low-level heat and producing mechanical energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Atomistic insights into the heat conductance across the interfaces between erythritol and different metals: A non-equilibrium molecular dynamics study

The heat conductance across the interface between a phase change material (PCM) and the metal shell is important for thermal design of latent heat storage systems. Non-equilibrium molecular dynamics simulations were carried out in this work to unravel, at the atomistic level, the interfacial heat conductance mechanisms between erythritol (the most promising medium-temperature polyol PCM) and two different metals (i.e., copper and aluminum). The interfacial contact ratio was introduced as a parameter to represent different contact conditions at the interfaces, for example, different surface roughness levels of the metals. It was found that with the increase of interfacial contact ratio, the temperature difference between the erythritol/metal interfaces decreases, whereas the interfacial heat transfer coefficient increases gradually. At the perfect contact condition, i.e., the interfacial contact ratio reaches 100%, the interfacial heat transfer coefficients across the erythritol/Cu and erythritol/Al interfaces were predicted to be 398 ± 26 MW/m 2 K and 544 ± 11 MW/m 2 K, respectively. The interfacial heat conductance of erythritol/Al is better than that of erythritol/Cu. The mismatch of atomic spectral density across the interfaces between erythritol and the two metals was analyzed and distinguished. These results could guide the selection of packaging materials and the thermal design of erythritol-based latent heat storage systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetocaloric refrigerator

The invention is for an apparatus and method for a refrigerator and a heat pump based on the magnetocaloric effect (MCE) offering a simpler, lighter, robust, more compact, environmentally compatible, and energy efficient alternative to traditional vapor-compression devices. The subject magnetocaloric apparatus alternately exposes portions of an MCE material to strong and weak magnetic field while coordinating the heat flow between the exposed portions by heat bridges to move the heat up the thermal gradient. The invention may be practiced with multiple MCE material portions or segments to attain large differences in temperature. Key applications include thermal management of electronics, as well as industrial and home refrigeration, heating, and air conditioning. The invention offers a simpler, lighter, compact, and robust apparatus compared to magnetocaloric devices of prior art. Furthermore, the invention may be run in reverse as a thermodynamic engine, receiving low-level heat and producing mechanical energy.

Vetrovec, Jan↗

Nonnuclear Experimental Capabilities to Support Design, Development, and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support nonnuclear testing and demonstration of technology in support of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the Single Primary Heat Extraction and Removal Emulator (SPHERE) and the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes noncontact infrared thermal imaging, surface thermocouples, spatially distributed fiber optic temperature and strain sensors, electrical power meters, and a water-cooled, gas-gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions. The MAGNET facility is a large-scale, 250-kW electrically heated microreactor test bed to enable nonnuclear experimental evaluation of a variety of microreactor concepts. It can be supplied to electrically heat a scaled section of a microreactor and further test the capabilities of heat rejection systems. The initial MAGNET experiments will support technology maturation and reduce uncertainty and risk associated with the design, operation, and deployment of monolithic heat pipe–based reactors. However, this test bed can broadly be applied to multiple microreactor concepts to evaluate a wide range of thermal-hydraulic and structural phenomena such as interface coupling with power conversion units and other collocated systems. MAGNET can evaluate integral thermomechanical effects during electrical heating of an array of heat pipes in a larger test article. Examples of initial testing will include thermal stresses in the monolith and the impact of debonding of a heat pipe from the core block and how that failure could impact surrounding heat pipes, i.e., understanding the potential for cascading failure. This work also discusses some modeling capabilities that can support experiment design, analysis, and interpretation, including the heat pipe code Sockeye and a comparison of thermal-structural simulations performed using ABAQUS and STAR-CCM+.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Relaxing the constant molar overflow assumption in distillation optimization

Abstract The constant molar overflow (CMO) framework, while useful for shortcut distillation models, assumes that all components have the same latent heats of vaporization. A simple transformation, from molar flows to latent‐heat flows, allows shortcut models to retain the mathematical simplicity of the CMO framework while accounting for different latent heats, resulting in the constant heat transport (CHT) framework for adiabatic distillation columns. Although several past works have already proposed this transformation in the literature, it has not been well utilized in recent times. In this article, we show the utility of this transformation in upgrading various applications such as identifying energy‐efficient multicomponent distillation configurations based on heat duty rather than surrogate vapor flow. The method transforms the diagram to a diagram. Furthermore, we derive new and insightful analytical results in distillation, such as cumulative latent‐heat stage fractions having monotonic profiles within a distillation column under the CHT framework.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗