Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Prelaunch self-discharge and charge-acceptance characteristics of the Hubble Space Telescope nickel hydrogen batteries

Tests performed at NASA/MSFC on the Hubble Space Telescope (HST) nickel-hydrogen batteries (flight spare module and flight spare battery) were used to determine self-discharge and charge-acceptance characteristics when the batteries were exposed to charged wet-stand conditions, pulse charging on the launch pad, and battery capacity at solar array deployment. An equation is presented which was used to predict the capacity that would be available in the HST NiH2 batteries after an extended stand time on the launch pad plus up to 2 days on orbit prior to solar array deployment (either ground power or orbiter power were used to supply HST loads until shortly before the solar arrays were deployed). It is shown that a fairly accurate estimate of the available capacity was made.

Lanier, John R., Jr.↗

Results of electric-vehicle propulsion system performance on three lead-acid battery systems

Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

Ewashinka, J. G.↗

Results of electric-vehicle propulsion system performance on three lead-acid battery systems

Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries) were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

Ewashinka, J. G.↗

Investigation of metal hydride materials as hydrogen reservoirs for metal-hydrogen batteries

The performance and suitability of various metal hydride materials were examined for use as possible hydrogen storage reservoirs for secondary metal-hydrogen batteries. Lanthanum pentanickel hydride appears as a probable candidate in terms of stable hydrogen supply under feasible thermal conditions. A kinetic model describing the decomposition rate data of the hydride has been developed.

ONISCHAK↗

Design and Performance of Tropical Rainfall Measuring Mission (TRMM) Super NiCd Batteries

The Tropical Rainfall Measuring Mission (TRMM) is a joint mission between NASA and the National Space Development Agency (NASDA) of Japan. The observatory is designed to monitor and study tropical rainfall and the associated release of energy that helps to power the global atmospheric circulation shaping both weather and climate around the globe. The spacecraft was launched from Japan on November 27,1997 via the NASDA H-2 launch vehicle. The TRMM Power Subsystem is a Peak Power Tracking system that can support the maximum TRMM load of 815 watts at the end of its three year life. The Power Subsystem consists of two 50 Ampere Hour Super NiCd batteries, Gallium Arsenide Solar Array and the Power System Electronics. This paper describes the TRMM Power Subsystem, battery design, cell and battery ground test performance, and in-orbit battery operations and performance.

Ahmad, Anisa J.↗

Nickel-cadmium batteries for the Modular Power Subsystem

Nickel-cadmium batteries of 20 and 50 ampere-hour (AH) capacity have been developed and qualified. These batteries provide an energy storage capability of 40 to 150 AH for the Modular Power Subsystem, which is the power source for NASA's Multimission Modular Spacecraft. Battery fabrication is rigidly controlled to assure uniform performance from battery to battery. A unique feature of the battery design is that cells from various manufacturers can be used for battery assembly without modification. Both 20 and 50-AH batteries have been delivered, and an MPS module with three 20-AH batteries is currently operating satisfactorily in low earth orbit. Design characteristics and performance of the batteries are described.

Mueller, V. C.↗

Update of the IUE battery in-flight performance

The in-flight performance data of two 17-cell, 6-ampere-hour nickel cadmium spacecraft batteries are presented covering 22 months of operation. Fluctuations in the battery voltage and the battery temperature are presented for spacecraft movement throughout a beta range of 0 to 130 deg. The battery discharge voltages during the peak eclipse seasons, daily seasons, and daily eclipse periods are noted. Finally, the spacecraft data are compared to data from a 6-ampere-hour test pack and test flight data.

Tiller, S. E.↗

Probabilistic modeling of solar power systems

The author presents a probabilistic approach based on Markov chain theory to model stand-alone photovoltaic power systems and predict their long-term service performance. The major advantage of this approach is that it allows designers and developers of these systems to analyze the system performance as well as the battery subsystem performance in the long run and determine the system design requirements that meet a specified service performance level. The methodology presented is illustrated by using data for a radio repeater system for the Boston, Massachusetts, location.

Safie, Fayssal M.↗

Results from the testing and analysis of LDEF batteries

Batteries were used on the Long Duration Exposure Facility (LDEF) to provide power to both the active experiments and the experiment support equipment such as the Experiment Initiative System, Experiment Power and Data System (data acquisition system), and the Environment Exposure Control Canisters. Three different types of batteries were used: lithium sulfur dioxide (LiSO2), lithium carbon monofluoride (LiCF), and nickel cadmium (NiCd). A total of 92 LiSO2, 10 LiCF, and 1 NiCd batteries were flown on the LDEF. In addition, approximately 20 LiSO2 batteries were kept in cold storage at NASA LaRC. The various investigations and post-flight analyses of the flight and control batteries are reviewed. The primary objectives of these studies was to identify degradation modes (if any) of the batteries and to provide information useful to future spacecraft missions. Systems SIG involvement in the post-flight evaluation of LDEF batteries was two-fold: (1) to fund SAFT (original manufacturer of the LiSO2 batteries) to perform characterization of 13 LiSO2 batteries (10 flight and 3 control batteries); and (2) to integrate investigator results.

Spear, Steve↗

The Long-Term Performance of Small-Cell Batteries Without Cell-Balancing Electronics

Tests approx.8 yrs ago showed Sony HC do not imbalance. AEA developed a theory (ESPC 2002): a) Self-discharge (SD) decreases with state-of-charge (SOC); b) Cells diverge to a state of dynamic equilibrium; c) Equilibrium spread depends on cell SD uniformity. Balancing model verified against test data. Short-term measures of SD difficult in Sony cells and very small values, depends on technique. Long-term evidence supports lower SD at low SD. Battery testing best proof of performance, typically mission specific tests.

Pearson, C.↗

X-57 Cruise Motor and High-Lift Motor Mission Profile Power Analysis

The X-57 Mission Profile Power Analysis was developed to evaluate the X-57 traction battery’s performance against Mod II, Mod III and Mod IV generic flight mission profiles. Traction battery system performance acceptance testing requirements were developed using data generated by this analysis. This analysis was also used to define the maximum power requirements for the traction system components.

Keith Harris↗

Operator strategies under varying conditions of workload

An attempt was made to operationally define and measure strategic behavior in a complex multiple task environment. The Multi-Attribute Task battery was developed to simulate various aspects of flight and consisted of an auditory communication task, monitoring tasks, a tracking tasks, a resource management task which allowed a wide range of responding patterns, and a scheduling window which allowed operators to predict changes in workload. This battery was validated for its sensitivity to strategic behavior, and baseline measures for each individual task were collected. Twenty-four undergraduate and graduate students then performed the battery for four 64 minute sessions which took place over a period of 2 days. Each subject performed the task battery under four levels of workload, which were presented for equal lengths of time during all four sessions. Results indicated that in general, performance improves as a function of experience with the battery, but that performance decreased as workload level increased. The data also showed that subjects developed strategies for responding to the resource management task which allowed them to manage the high workload levels more efficiently. This particular strategy developed over time but was also associated with errors of complacency. These results are presented along with implications for the aviation field and areas of future research.

Arnegard, Ruth J.↗

Upgraded demonstration vehicle task report

Vehicle/battery performance capabilities and interface problems that occurred when upgraded developmental batteries were integrated with upgraded versions of comercially available electric vehicles were investigated. Developmental batteries used included nickel zinc batteries, a nickel iron battery, and an improved lead acid battery. Testing of the electric vehicles and upgraded batteries was performed in the complete vehicle system environment to characterize performance and identify problems unique to the vehicle/battery system. Constant speed tests and driving schedule range tests were performed on a chassis dynamometer. The results from these tests of the upgraded batteries and vehicles were compared to performance capabilities for the same vehicles equipped with standard batteries.

Bryant, J.↗

Program Diagnoses Nickel/Cadmium Batteries

Nickel Cadmium Battery Expert System-2 (NICBES2) computer program is prototype expert-system program for diagnosis and management of health of nickel/cadmium batteries. Intended to support evaluation of performance of batteries in Hubble Space Telescope spacecraft and to alert personnel to possible malfunctions. Oversees status of batteries by evaluating data gathered in orbit packets, and when so merits, raises alarm and provides diagnosis of faults as well as advice on actions to be taken to remedy condition giving rise to alarm. Provides history of statuses of batteries pertaining to health of batteries, and graphical display to help operator assimilate information generated. Written in C language.

Johnson, Yvette B.↗

Design, development, performance, and reconditioning of Ni-Cd batteries using polyropylene separators

A performance assessment is made for the Viking Mars Lander Program's sealed, sterilizable, 8-ampere hour Ni-Cd batteries, which use a nonwoven polypropylene separator material. Attention is given to separator wettability, the optimization of electrolyte quantity, and the reduction of plate carbonate, in view of thermal considerations and other environmental design and test requirements generated by mission characteristics. Life data based on mission experience identify, in addition to performance and degradation behavior, a series of shallow discharge reconditioning cycles and an intensive program of deep discharge reconditioning.

Britting, A. O., Jr.↗