Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bone Fracture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

162 records · Page 9

Spaceflight-induced Bone Loss: Countermeasures and Their Evaluations

The learning objectives of this viewgraph presentation are to: (1) Understand the biomedical effects of spaceflight and their associated health risks. (2) Understand how the "Factor of Risk" for fracture can be calculated in the adult skeleton for space travel. and (3) Understand how various countermeasures [CMs] influence the Factor of Risk.

Sibonga, Jean D.↗

Evaluation of HCF strength of Alloy 625 with non-optimum additive manufacturing process parameters

An extensive experimental program was undertaken to generate the process-structure-HCF property data for additive-manufactured Alloy 625. Round tensile and flat dog-bone HCF specimens were fabricated using a laser powder bed fusion process. Several builds were fabricated with different processing parameters. The fatigue strengths were determined using a step-test method and fracture surfaces were characterized to identify the critical microstructure feature associated with the formation of the fatigue crack. Finally, a fracture mechanics-based methodology using fatigue crack growth data measured on a wrought alloy is shown to provide conservative estimates of the HCF lives for the additive-manufactured alloy.

36 MATERIALS SCIENCE↗

CD206 + Trem2 + macrophage accumulation in the murine knee joint after injury is associated with protection against post-traumatic osteoarthritis in MRL/MpJ mice

Post-traumatic osteoarthritis (PTOA) is a painful joint disease characterized by the degradation of bone, cartilage, and other connective tissues in the joint. PTOA is initiated by trauma to joint-stabilizing tissues, such as the anterior cruciate ligament, medial meniscus, or by intra-articular fractures. In humans, ~50% of joint injuries progress to PTOA, while the rest spontaneously resolve. To better understand molecular programs contributing to PTOA development or resolution, we examined injury-induced fluctuations in immune cell populations and transcriptional shifts by single-cell RNA sequencing of synovial joints in PTOA-susceptible C57BL/6J (B6) and PTOA-resistant MRL/MpJ (MRL) mice. We identified significant differences in monocyte and macrophage subpopulations between MRL and B6 joints. A potent myeloid-driven anti-inflammatory response was observed in MRL injured joints that significantly contrasted the pro-inflammatory signaling seen in B6 joints. Multiple CD206 + macrophage populations classically described as M2 were found enriched in MRL injured joints. These CD206 + macrophages also robustly expressed Trem2 , a receptor involved in inflammation and myeloid cell activation. These data suggest that the PTOA resistant MRL mouse strain displays an enhanced capacity of clearing debris and apoptotic cells induced by inflammation after injury due to an increase in activated M2 macrophages within the synovial tissue and joint space.

60 APPLIED LIFE SCIENCES↗

Miniature X-Ray Bone Densitometer

The purpose of the Dual Energy X-ray Absorptiometry (DEXA) project is to design, build, and test an advanced X-ray absorptiometry scanner capable of being used to monitor the deleterious effects of weightlessness on the human musculoskeletal system during prolonged spaceflight. The instrument is based on the principles of dual energy x-ray absorptiometry and is designed not only to measure bone, muscle, and fat masses but also to generate structural information about these tissues so that the effects on mechanical integrity may be assessed using biomechanical principles. A skeletal strength assessment could be particularly important for an astronaut embarking on a remote planet where the consequences of a fragility fracture may be catastrophic. The scanner will employ multiple projection images about the long axis of the scanned subject to provide geometric properties in three dimensions, suitable for a three-dimensional structural analysis of the scanned region. The instrument will employ advanced fabrication techniques to minimize volume and mass (100 kg current target with a long-term goal of 60 kg) of the scanner as appropriate for the space environment, while maintaining the required mechanical stability for high precision measurement. The unit will have the precision required to detect changes in bone mass and geometry as small as 1% and changes in muscle mass as small as 5%. As the system evolves, advanced electronic fabrication technologies such as chip-on-board and multichip modules will be combined with commercial (off-the-shelf) parts to produce a reliable, integrated system which not only minimizes size and weight, but, because of its simplicity, is also cost effective to build and maintain. Additionally, the system is being designed to minimize power consumption. Methods of heat dissipation and mechanical stowage (for the unit when not in use) are being optimized for the space environment.

Charles, Harry K., Jr.↗

Assessment of metabolic bone diseases by quantitative computed tomography

Advances in the radiologic sciences have permitted the development of numerous noninvasive techniques for measuring the mineral content of bone, with varying degrees of precision, accuracy, and sensitivity. The techniques of standard radiography, radiogrammetry, photodensitometry, Compton scattering, neutron activation analysis, single and dual photon absorptiometry, and quantitative computed tomography (QCT) are described and reviewed in depth. Results from previous cross-sectional and longitudinal QCT investigations are given. They then describe a current investigation in which they studied 269 subjects, including 173 normal women, 34 patients with hyperparathyroidism, 24 patients with steroid-induced osteoporosis, and 38 men with idiopathic osteoporosis. Spinal quantitative computed tomography, radiogrammetry, and single photon absorptiometry were performed, and a spinal fracture index was calculated on all patients. The authors found a disproportionate loss of spinal trabecular mineral compared to appendicular mineral in the men with idiopathic osteoporosis and the patients with steroid-induced osteoporosis. They observed roughly equivalent mineral loss in both the appendicular and axial regions in the hyperparathyroid patients. The appendicular cortical measurements correlated moderately well with each other but less well with spinal trabecular QCT. The spinal fracture index correlated well with QCT and less well with the appendicular measurements. Knowledge of appendicular cortical mineral status is important in its own right but is not a valid predictor of axial trabecular mineral status, which may be disproportionately decreased in certain diseases. Quantitative CT provides a reliable means of assessing the latter region of the skeleton, correlates well with the spinal fracture index (a semiquantitative measurement of end-organ failure), and offers the clinician a sensitive means of following the effects of therapy.

Minerals/analysis↗

Zoledronate Prevents Simulated Weightlessness-Induced Bone Loss in the Cancellous Compartment While Blunting the Efficacy of a Mechanical Loading Countermeasure

Astronauts using high-force resistance training while weightless show a high-turnover remodeling state within the skeletal system, with resorption and formation biomarkers being elevated. One countermeasure for the skeletal health of astronauts includes an antiresorptive of the bisphosphonate (BP) drug class. We asked, does the combination of an anti-resorptive and high-force exercise during weightlessness have negative effects on bone remodeling and strength? In this study, we developed an integrated model to mimic the mechanical strain of exercise via cyclical loading (CL) in mice treated with the BP Zoledronate (ZOL) combined with hind limb unloading (HU) to simulate weightlessness. We hypothesized that ZOL prevents structural degradation from simulated weightlessness and that CL and ZOL interact to render CL less effective. Thirty-two C57BL/6 mice (male, 16 weeks old, n=8/group) were exposed to 3 weeks of either HU or normal ambulation (NA). Cohorts of mice received one subcutaneous injection of ZOL (45μg/kg), or saline vehicle (VEH), prior to the start of HU. The right tibia was axially compressed in vivo 60x/day to 9N (+1200μstrain on the periosteal surface) and repeated 3x/week during HU. Left tibiae served as a within subject, non-compressed control. Ex vivo μCT was performed on all subjects to determine cancellous and cortical architectural parameters. Static and dynamic histomorphometry were carried out for the left and right tibiae to determine osteoclast- and osteoblast relevant surfaces. Further, micro damage was assessed in select groups by basic-fuchsin staining to test whether CL had an effect. For all assays, a multivariate (2x2x2) ANCOVA model was used to account for body weight changes. Additionally, for the tibiae, we incorporated a random effect for the subject (hence, a mixed model) to account for observations of both left and right tibiae within each subject. P < 0.05 was considered significant. In the cancellous compartment of the proximal tibial metaphysis, we observed a main effect from each independent variable, as determined by structural and histomorphometric assays. Specifically, as expected, ZOL showed an increase in the cancellous bone volume to total volume fraction (BV/TV, +32%) and trabecular number (+18%) compared to the VEH. As expected, ZOL decreased osteoclast surface (OC/BS) by -45% compared to VEH. Surprisingly, ZOL reduced mineralizing surface (MS/BS) and bone formation rate (BFR), indicators of osteoblast activity, by -40% and -54%, respectively, compared to VEH. Altogether, ZOL-treated mice displayed a low turnover state of remodeling in the metaphysis. In the context of skeletal aging, we speculate that ZOL prevented age-related cancellous strut loss during the experiment. As a main effect, as expected, HU decreased BV/TV by - 31% via reductions in both trabecular thickness (-11%) and number (-22%) compared to NA controls. Additionally, HU decreased MS/BS by -38% and bone formation rate (BFR) by -50% compared to NA controls. Altogether, these data are consistent with structural degradation resulting from imbalanced remodeling that favors resorption. As a main effect, CL increased BV/TV by +15% via increased trabecular thickness (+12%) compared to the noncompressed limb. As expected, CL increased MS/BS (+20%) and BFR (+24%), indicating osteoblast mineralization contributed to bone gains. These data show that CL provided an anabolic stimulus to the cancellous tissue. We observed unique interactions in ZOL*CL and HU*CL. First, ZOL prevented CL-induced increases in BV/TV and trabecular number, as compared to VEH. In the context of skeletal aging, these data suggest no added benefit from CL in the ZOL-treated mice. Interestingly, no microdamage was observed in mice that were unloaded and treated with ZOL (independent of CL). Secondly, HU prevented CL-induced increases in BFR, as compared to NA controls. These data suggest that either exercise is less effective or the kinetics of formation are slower during simulated weightlessness. Osteoclast surface was unchanged by either treatment. Thus, in contrast to exercising astronauts, these data do not suggest a high-turnover state in the metaphysis. To assess mechanical properties as a function of HU or ZOL, we tested the left femur in three-point bending ex vivo. As expected, HU decreased stiffness (-30%) compared to NA, and ZOL increased stiffness compared to VEH (+28%). Interestingly, HU increased the post-yield displacement, related to collagenous tensile loading, compared to NA (+20%). ZOL increased yield force (+11%) and ultimate force (+17%), which seems to explain the significant effect of ZOL increasing total energy (work-to-fracture, +15%), while not affecting the post yield displacement. Taken together, ZOL did not have detrimental affect on mechanical properties. Our integrated model simulates the combination of weightlessness, exercise-induced mechanical strain, and anti-resorptive treatment that astronauts experience during space missions. We conclude that Zoledronate was an effective countermeasure against weightlessness-induced bone loss, though zoledronate, as well as weightlessness, rendered exercise-related mechanical loading less effective.

bone↗

In situ synchrotron tensile investigations on ultrasonic additive manufactured (UAM) zirconium

The microstructure evolution during room temperature uniaxial tensile straining of ultrasonic additive manufactured (UAM) zirconium was evaluated using the Advanced Photon Source (APS) facility. Miniature dog-bone tensile specimens of two orientations were cut from a UAM-fabricated zirconium bar for in situ synchrotron tensile tests. Wide-angle X-ray scattering (WAXS) scanning was used to unveil the changes in microstructure of the entire gauge regions throughout the straining. A series of WAXS data analysis methods were utilized to quantify both elastic and plastic deformation mechanisms within the strained specimens. Stress concentrations were identified during early stages of plastic deformation, which become candidate necking positions and eventually lead to failure. Additionally, fracture surface analysis implied that these stress concentration locations may be correlated to the fabrication defects, providing insightful guidance for future improvements of the UAM zirconium fabrication process.

36 MATERIALS SCIENCE↗

Risk Of Early Onset Osteoporosis Due To Spaceflight

Bone minerals decline in microgravity, and bone mineral density (BMD) losses of approximately -1 to -1.5% per month were calculated for astronauts serving on long-duration missions prior to 2009. It is unclear whether BMD losses will stabilize with time in space, or continue to diminish with time. In addition, it is unknown if fractional gravity, present on the moon and Mars, will mitigate the mineral loss. Clinicians diagnose osteoporosis in premenopausal females and males younger than 50 years on the basis of BMD T-scores < -2.5 (hip and lumbar spine) accompanied by clinical evidence of a fragility fracture. If mission-related changes to the skeleton cannot be corrected by rehabilitation after the mission, crewmembers could be at risk for premature osteoporosis-related fractures in later life. To mitigate this risk it is necessary to understand the dynamics underlying the BMD changes that occur in microgravity, to monitor for the persistence of changes after space flight, and to evaluate if and how current and future osteoporosis treatments might be used to mitigate the risk of long-term skeletal problems in astronauts.

Sibonga, Jean↗

In Situ Synchrotron Tensile Investigations on Ultrasonic Additive Manufactured (UAM) Zirconium

The microstructure evolution of ultrasonic additive manufactured (UAM) zirconium under room temperature uniaxial tensile straining is reported. Miniature dog-bone tensile specimens of two orientations were cut from a UAM zirconium bar for in situ synchrotron tensile tests. Wide-angle X-ray scattering (WAXS) scanning at the Advanced Photon Source (APS) at Argonne National Laboratory was used to unveil the changes in microstructure of the entire gauge regions throughout the straining. A series of WAXS data analysis methods were utilized to quantify both elastic and plastic deformation mechanisms within the strained specimens. Stress concentrations were identified during early stage of plastic deformation, which become candidate necking positions and eventually lead to failure. Fracture surface analysis implied that these stress concentration locations may be correlated to the fabrication defects, providing insightful guidance for future improvement of the UAM zirconium process.

36 MATERIALS SCIENCE↗

Numerical Evaluation of Mode 1 Stress Intensity Factor as a Function of Material Orientation For BX-265 Foam Insulation Material

Foam; a cellular material, is found all around us. Bone and cork are examples of biological cell materials. Many forms of man-made foam have found practical applications as insulating materials. NASA uses the BX-265 foam insulation material on the external tank (ET) for the Space Shuttle. This is a type of Spray-on Foam Insulation (SOFI), similar to the material used to insulate attics in residential construction. This foam material is a good insulator and is very lightweight, making it suitable for space applications. Breakup of segments of this foam insulation on the shuttle ET impacting the shuttle thermal protection tiles during liftoff is believed to have caused the space shuttle Columbia failure during re-entry. NASA engineers are very interested in understanding the processes that govern the breakup/fracture of this complex material from the shuttle ET. The foam is anisotropic in nature and the required stress and fracture mechanics analysis must include the effects of the direction dependence on material properties. Material testing at NASA MSFC has indicated that the foam can be modeled as a transversely isotropic material. As a first step toward understanding the fracture mechanics of this material, we present a general theoretical and numerical framework for computing stress intensity factors (SIFs), under mixed-mode loading conditions, taking into account the material anisotropy. We present mode I SIFs for middle tension - M(T) - test specimens, using 3D finite element stress analysis (ANSYS) and FRANC3D fracture analysis software, developed by the Cornel1 Fracture Group. Mode I SIF values are presented for a range of foam material orientations. Also, NASA has recorded the failure load for various M(T) specimens. For a linear analysis, the mode I SIF will scale with the far-field load. This allows us to numerically estimate the mode I fracture toughness for this material. The results represent a quantitative basis for evaluating the strength and fracture properties of anisotropic foam insulation material.

Knudsen, Erik↗

Influence of Processing Parameters on the Mechanical Properties of 3D Printed Borosilicate Particulate Reinforced Polymer Composites

Emerging composite materials are expanding the potential of additive manufacturing and enabling applications previously restricted by traditional manufacturing methods. The multi-phase nature of these composite materials combined with the complex in-ternal geometry of additively manufactured parts have enabled unique behavior, and potentially new applications. Additionally, these materials can be pyrolyzed to create dense metal, ceramic, and glass parts with geometries typically not achievable by tra-ditional processes. Additive manufacturing of borosilicate glass-based systems can open new applications in nuclear engineering, astronomy, and bone regrowth therapy. To elucidate the process-parameter relationship of borosilicate-polylactic acid (PLA) composites, mechanical testing was conducted and compared with a pure polylactic acid polymer baseline. Test specimens were fabricated by fused-filament fabrication with minimal post-processing. Yield strength, ultimate strength, and elastic modulus were calculated from stress-strain curves. Optical and scanning electron microscopy were conducted to observe the specimen microstructure before and after testing. The highest compressive yield strength for the composite was 28.22 MPa, and the highest compressive yield strength for PLA was 49.30 MPa. Print orientation was found to benefit the composite material but have a detrimental effect on the pure matrix material. An elastic modulus of 2.66 GPa was recorded for the borosilicate-PLA composite at 100% infill, 1 shell wall, and layer lines parallel to compression axis. Microscopy revealed that lower modulus composite specimens had the particulates re-distributed within the matrix. Tensile testing was done according to a polymer testing standard, which caused difficulties obtaining consistent fracture within the gauge length.

mechanical testing↗

Bone Density Following Three Years of Recovery from Long-Duration Space-Flight

Bone loss during long-duration space flight is well recognized, but the long-term implications on bone health following return from flight remain unclear. Among US crew who were involved in long-duration missions in space (Mir and ISS), we have previously shown that at approximately 12 months following return, men, but not women, had BMD values at most sites that were still lower than would be expected had they not been exposed to a prolonged period of microgravity. We now extend our observations to 3 years of follow-up post-flight. Using their age, pre-flight BMD and follow-up time, post-flight BMD values for each US crew were predicted based on the model developed from the community sample. We found BMD measures to be either stable or improve by 3 years relative to their immediate post-flight BMD, however only total hip BMD still remains significantly lower than would be expected had they not been exposed to microgravity. Among male US crew, who have had their BMD measured following at least 3 years of recovery post long-duration flight, they continue to have lower BMD at the hip than would be expected, raising potential concerns regarding future hip fracture risk.

Amin, S.↗

Ultrasound Imaging of Spine: State of the Art and Utility for Space Flight

Introduction: Ultrasound imaging (sonography) has been increasingly used for both primary diagnosis and monitoring of musculoskeletal injury, including fractures. In certain injuries, sonography has been shown to equal or surpass Magnetic Resonance Imaging in accuracy. Long-term exposure to reduced gravity may be expected to cause physiological and anatomical changes of the musculoskeletal system, which are not fully described or understood. In a limited-resource environment like space flight, sonography will likely remain the only imaging modality; therefore, further attention to its potential is warranted, including its ability to image anatomical deviations as well as irregularities of vertebrae and the spinal column. Methods: A thorough review of literature was conducted on the subject. A multipurpose ultrasound system was used to identify specific vertebrae, intervertebral disks, and other structures of the cervical spine in healthy volunteers, selected to represent various age, gender, and Body Mass Index (BMI) groups. Sonographic views were sought that would parallel radiographic views and signs used in the diagnosis of cervical spine injuries. Results: While using widely accepted radiographic signs of cervical spine injury, this sonographic protocol development effort resulted in successful identification of scanning planes and imaging protocols that could serve as alternatives for radiography. Some of these views are also applicable to diagnosing degenerative disk and bone disease, and other non-traumatic spine pathology. Strong, preliminary correlation has been demonstrated in a number of clinical cases between sonography and other imaging modalities. Conclusion: In the absence of radiography, sonography can be used to diagnose or rule out certain common types of cervical spine conditions including injury. Clinical validation of the findings appears to be realistic and would facilitate establishment of new sonographic protocols for special environments with lacking radiographic capability, such as human space flight.

Sargsyan, Ashot E.↗

Blunt Impact Brain Injury using Cellular Injury Criterion

The Advanced Combat Helmet (\ACH") military specification (\mil-spec") requires a helmeted magnesium (\Mg") Department of Transportation (\DOT") headform be dropped vertically, with an impact speed of 3.1 m/s (10 ft/s), onto a steel hemispherical target. The pass/fail criteria are based on translational acceleration (150 G) alone, absent of any rotational component. Without a rotational component, the specification's injury risk application is limited to skull fracture and peripheral hematomas (subdural, subarachnoid), since this translational acceleration injury risk assessment is based on the Wayne State Tolerance Curve (\WSTC"). To provide a more comprehensive view of injury for the entire brain, an alternative approach is needed. To meet this need, we worked with a larger group called PANTHER, a collaboration between national laboratories, industry, and academia. Collaborations specific to research and results presented here come from efforts led by Mr. Ron Szalkowski and Mr. Sushant Malave, Ms. Alice Fawzi, and Dr. Christian Franck. We have developed a prototypical injury risk criterion based on the neuronal response to abrupt changes in general motion (translation, rotation, or both). The cellular-based mild traumatic brain injury (\cbmTBI") criterion utilizes both the strain and strain rate of brain tissue to account for the stretch and rate of stretch that occurs throughout the brain as a result of blunt impact to the head. We conducted physical experiments of an ACH-fitted magnesium headform, which produced repeatable headform peak accelerations. Then, we developed a simulation of the experiment, and validated the simulation output with the experimental data. We then substituted the magnesium headform with a human headform, consisting of skin, muscle, bone, gray matter, white matter, cerebral-spinal fluid, membranes, vasculature, intravertebral discs, airway and sinus. We quantified brain injury risk using the cbmTBI criterion, using the current mil-spec test and a modified test. The modified mil-spec test used an inclined anvil target that was located posterior to the crown of the helmet in the axial plane. While the current mil-spec test produced brain deformation from head translation alone, the modified test produced brain deformation from head translation and rotation, which is closer to most real world and combat theater impacts (e.g., such as occur in tertiary blast exposure). Compared to the current mil-spec test, the modified test produced elevated strains in the human digital twin. These data, mapped to the cbmTBI criterion, suggest increased injury risk for blunt impacts that cause rotation and translation, rather than just translation alone. Moreover, these data may lead to a rotational performance metric, which is rooted in the biology and pathology of the brain's response to impact and blast, and which should be used to improve next-generation helmet designs.

42 ENGINEERING↗

Toughening materials: enhancing resistance to fracture

It has been said that ‘God invented plasticity, but the Devil invented fracture!’ Both mechanisms represent the two prime modes of structural failure, respectively, plastic collapse and the rupture/breaking of a component, but the concept of developing materials with enhanced resistance to fracture can be difficult. This is because fracture resistance invariably involves a compromise—between strength and ductility, between strength and toughness—fundamentally leading to a ‘conflict’ between nano-/micro-structural damage and the mechanisms of toughening. Here, we examine the two major classes of such toughening: (i) intrinsic toughening, which occurs ahead of a crack tip and is motivated by plasticity—this is the principal mode of fracture resistance in ductile materials, and (ii) extrinsic toughening, which occurs at, or in the wake of, a crack tip and is associated with crack-tip shielding—this is generally the sole mode of fracture resistance in brittle materials. We briefly examine how these distinct mechanistic processes have been used to toughen synthetic materials—intrinsically in gradient materials and in multiple principal-element metallic alloys with the example of metallic glasses and high-entropy alloys, and extrinsically in ceramics with the example of ceramic-matrix composites—in comparison to Nature which has been especially adept in creating biological/natural materials which are toughened by one or both mechanistic classes, despite often consisting of constituents with meagre mechanical properties. The success of Nature has been driven by its ability to cultivate the development of materials with multiple length-scale hierarchical structures that display ingenious gradients and structural adaptability, a philosophy which we need to emulate and more importantly learn to synthesize to make structural materials of the future with unprecedented combinations of mechanical properties.

36 MATERIALS SCIENCE↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗

Mineralogical, magnetic and geochemical data constrain the pathways and extent of weathering of mineralized sedimentary rocks

The oxidative weathering of sulfidic rock can profoundly impact watersheds through the resulting export of acidity and metals. Weathering leaves a record of mineral transformation, particularly involving minor redox-sensitive phases, that can inform the development of conceptual and quantitative models. In sulfidic sedimentary rocks, however, variations in depositional history, diagenesis and mineralization can change or overprint the distributions of these trace minerals, complicating the interpretation of weathering signatures. Here we show that a combination of bulk mineralogical and geochemical techniques, micrometer-resolution X-ray fluorescence microprobe analysis and rock magnetic measurements, applied to drill core samples and single weathered fractures, can provide data that enable the development of a geochemically consistent weathering model. This work focused on one watershed in the Upper Colorado River Basin sitting within the Mesaverde Formation, a sedimentary sandstone bedrock with disseminated sulfide minerals, including pyrite and sphalerite, that were introduced during diagenesis and subsequent magmatic-hydrothermal mineralization. Combined analytical methods revealed the pathways of iron (Fe), carbonate and silicate mineral weathering and showed how pH controls element retention or release from the actively weathering fractured sandstone. Drill core logging, whole rock X-ray diffraction, and geochemical measurements document the progression from unweathered rock at depth to weathered rock at the surface. X-ray microprobe analyses of a 1-cm size weathering profile along a fracture surface are consistent with the mobilization of Fe(II) and Fe(III) into acidic pore water from the dissolution of primary pyrite, Fe-sphalerite, chlorite, and minor siderite and pyrrhotite. These reactions are followed by the precipitation of secondary minerals such as of goethite and jarosite, a Fe-(oxyhydr)oxide and hydrous Fe(III) sulfate, respectively. Microscale analyses also helped explain the weathering reactions responsible for the mineralogical transformations observed in the top and most weathered section of the drill core. For example, dissolution of feldspar and chlorite neutralizes the acidity generated by Fe and sulfide mineral oxidation, oversaturating the solution in both Fe-oxides. The combination of X-ray spectromicroscopy and magnetic measurements show that the Fe(III) product is goethite, mainly present either as a coating on fracture surfaces in the actively weathering region of the core or more homogeneously contained within the unconsolidated regolith at the top of the core. Low-temperature magnetic data reveal the presence of ferromagnetic Fe-sulfide pyrrhotite that, although it occurs at trace concentrations, could provide a qualitative proxy for unweathered sulfide minerals because the loss of pyrrhotite is associated with the onset of oxidative weathering. Pyrrhotite loss and goethite formation are detectable through room-temperature magnetic coercivity changes, suggesting that rock magnetic measurements can determine weathering intensity in rock samples at many scales. In conclusion, this work contributes evidence that the weathering of sulfidic sedimentary rocks follows a geochemical pattern in which the abundance of sulfide minerals controls the generation of acidity and dissolved elements, and the pH-dependent mobility of these elements controls their export to the ground- and surface-water.

58 GEOSCIENCES↗

Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators

A shape reminiscent of a dog bone has been found to be superior to other shapes for mechanical-amplification horns that are components of piezoelectrically driven actuators used in a series of related devices denoted generally as ultrasonic/sonic drill/corers (USDCs). The first of these devices was reported in Ultrasonic/Sonic Drill/Corers With Integrated Sensors (NPO-20856), NASA Tech Briefs, Vol. 25, No. 1 (January 2001), page 38. The dog-bone shape was conceived especially for use in a more recent device in the series, denoted an ultrasonic/ sonic gopher, that was described in Ultrasonic/Sonic Mechanisms for Drilling and Coring (NPO-30291), NASA Tech Briefs, Vol. 27, No. 9 (September 2003), page 65. The figure shows an example of a dog-bone-shaped horn and other components of an ultrasonic gopher. Prerequisite to a meaningful description of this development is an unavoidably lengthy recapitulation of the principle of operation of a USDC and, more specifically, of the ultrasonic/sonic gopher as described previously in NASA Tech Briefs. The ultrasonic actuator includes a stack of piezoelectric rings, the horn, a metal backing, and a bolt that connects the aforementioned parts and provides compressive pre-strain to the piezoelectric stack to prevent breakage of the rings during extension. The stack of piezoelectric rings is excited at the resonance frequency of the overall ultrasonic actuator. Through mechanical amplification by the horn, the displacement in the ultrasonic vibration reaches tens of microns at the tip of the horn. The horn hammers an object that is denoted the free mass because it is free to move longitudinally over a limited distance between hard stops: The free mass bounces back and forth between the ultrasonic horn and a tool bit (a drill bit or a corer). Because the longitudinal speed of the free mass is smaller than the longitudinal speed of vibration of the tip of the horn, contact between the free mass and the horn tip usually occurs at a phase of the vibration favorable to transfer of momentum from the horn to the free mass. Therefore, the free mass picks up momentum and is accelerated back to the tool bit. Upon impact of the free mass on the tool bit, momentum is transferred to the tool bit. The impacts of the free mass on the tool bit repeat at a sonic frequency that can range from tens of hertz to about 1 kHz. The shock waves caused by the impacts of the free mass propagate to the interface between the tool bit and the medium (typically, rock, ice, or other brittle material) to be drilled or cored. The medium becomes fractured when its ultimate strain is exceeded at the medium/tool-bit interface. This concludes the description of the principle of operation.

Sherrit, Stewart↗