Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bone imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SU-E-T-588: Optimization of Imaging Following 223Ra Administration in Targeted Alpha-Emitting Radionuclide Therapy of Bone Metastases

Purpose: With a growing demand of alpha-emitting radiopharmaceuticals, especially Xofigo ({sup 223}RaCl{sub 2}) which is used in the treatment of metastatic bone disease, the optimization of dosimetry becomes necessary. Indeed, in Europe, as stated on the council directive 2013/59/euratom, exposures of target volumes for radiotherapeutic purposes shall be individually planned taking into account that doses to non-target volumes and tissues shall be as low as reasonably achievable. To that aim, the possibility of imaging {sup 223}Ra was first investigated. Methods: The experiments were conducted at the Hopital Europeen Georges Pompidou with an Infinia Hawkeye 4 gamma camera, equipped with a medium-energy collimator. Imaging parameters, such as sensibility, spatial resolution and energy spectrum, were determined using several physical phantoms with a source of 6 MBq of {sup 223}Ra. Bone metastases were modeled with a NEMA Body Phantom to investigate image degradation based on the concentration of {sup 223}Ra. Results: The acquired energy spectrum allowed to visualize several photon peaks: at 85, 154 and 270 keV. Camera sensitivity measured from the phantom study was 102.3 cps/MBq for the 85 keV ± 20 %, 89.9 cps/MBq for the 154 ± 20 % window and 65.4 cps/MBq for the 270 ± 10 % window. The spatial resolution (full-width at half-maximum) was respectively 1.7, 1.9 and 1.8 cm for the three energy windows. SPECT/CT images of NEMA Body Phantom without and with attenuation have permitted to determine the best reconstruction parameters. Conclusion: This study has demonstrated that it is possible to obtain clinically relevant information from images of {sup 223}Ra. All these results will be valuable to analyze biodistribution imaging of the radiopharmaceutical in the patient body and go further in the reconstruction of patient images in order to personalize the dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Removal of bone in CT angiography by multiscale matched mask bone elimination

For clear visualization of vessels in CT angiography (CTA) images of the head and neck using maximum intensity projection (MIP) or volume rendering (VR) bone has to be removed. In the past we presented a fully automatic method to mask the bone [matched mask bone elimination (MMBE)] for this purpose. A drawback is that vessels adjacent to bone may be partly masked as well. We propose a modification, multiscale MMBE, which reduces this problem by using images at two scales: a higher resolution than usual for image processing and a lower resolution to which the processed images are transformed for use in the diagnostic process. A higher in-plane resolution is obtained by the use of a sharper reconstruction kernel. The out-of-plane resolution is improved by deconvolution or by scanning with narrower collimation. The quality of the mask that is used to remove bone is improved by using images at both scales. After masking, the desired resolution for the normal clinical use of the images is obtained by blurring with Gaussian kernels of appropriate widths. Both methods (multiscale and original) were compared in a phantom study and with clinical CTA data sets. With the multiscale approach the width of the strip of soft tissue adjacent to the bone that is masked can be reduced from 1.0 to 0.2 mm without reducing the quality of the bone removal. The clinical examples show that vessels adjacent to bone are less affected and therefore better visible. Images processed with multiscale MMBE have a slightly higher noise level or slightly reduced resolution compared with images processed by the original method and the reconstruction and processing time is also somewhat increased. Nevertheless, multiscale MMBE offers a way to remove bone automatically from CT angiography images without affecting the integrity of the blood vessels. The overall image quality of MIP or VR images is substantially improved relative to images processed with the original MMBE method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-248: Comparative Study of Two Image Registration for Image-Guided Radiation Therapy in Esophageal Cancer

Purpose: Image-guided radiation therapy (IGRT) is one of the major treatment of esophageal cancer. Gray value registration and bone registration are two kinds of image registration, the purpose of this work is to compare which one is more suitable for esophageal cancer patients. Methods: Twenty three esophageal patients were treated by Elekta Synergy, CBCT images were acquired and automatically registered to planning kilovoltage CT scans according to gray value or bone registration. The setup errors were measured in the X, Y and Z axis, respectively. Two kinds of setup errors were analysed by matching T test statistical method. Results: Four hundred and five groups of CBCT images were available and the systematic and random setup errors (cm) in X, Y, Z directions were 0.35, 0.63, 0.29 and 0.31, 0.53, 0.21 with gray value registration, while 0.37, 0.64, 0.26 and 0.32, 0.55, 0.20 with bone registration, respectively. Compared with bone registration and gray value registration, the setup errors in X and Z axis have significant differences. In Y axis, both measurement comparison results of T value is 0.256 (P value > 0.05); In X axis, the T value is 5.287(P value < 0.05); In Z axis, the T value is −5.138 (P value < 0.05). Conclusion: Gray value registration is recommended in image-guided radiotherapy for esophageal cancer and the other thoracic tumors. Manual registration could be applied when it is necessary. Bone registration is more suitable for the head tumor and pelvic tumor department where composed of redundant interconnected and immobile bone tissue.

60 APPLIED LIFE SCIENCES↗

Experimental study of transmission of a pulsed focused beam through a skull phantom in nonlinear regime

In the paper the use of receiving and radiating system, which allows to determine the parameters of bone by nonlinear pulse-echo technique and to image of brain structures through the skull bones, was proposed. Accuracy of the skull bone characterization is due to higher measured harmonic and is significantly better than in linear case. In the experimental part focused piezoelectric transducer with diameter 100 mm, focal distance 100 mm, the frequency of 1.092 MHz was used. It was shown that skull bone profiling can be performed with the use of 3rd harmonic since 1st harmonic can be used for visualization of the underlying objects. The use of wideband systems for both skull profiling and brain visualization is restricted by skull attenuation and resulting low effective sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Management of Lumbar Spondylolysis in Athletes: Role of Imaging

Purpose of review: Spondylolysis is a broad term, with advances in imaging enabling more accurate diagnosis of the activity and severity of a lesion. This review discusses the role of different imaging modalities in the diagnosis and management of lumbar spondylolysis in athletes. Recent Findings: Magnetic resonance imaging (MRI) has diagnostic and practical advantages over other imaging modalities and is particularly useful for detecting early stages of bone stress, including pre-symptomatic screening for active lumbar bone stress injuries. Whilst computed tomography remains the best imaging technique to visualise cortical breaches, specialised MRI sequences offer a viable alternative to detect active bone stress and chronic non-united defects. Summary: Imaging provides important information for the clinical management of athletes with lumbar spondylolysis. Roles for imaging, in particular MRI, include: (a) proactive screening and early detection, (b) diagnosis of a symptomatic lesion and (c) monitor healing and readiness to return to sport.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved UTE-based attenuation correction for cranial PET-MR using dynamic magnetic field monitoring

Purpose: Ultrashort echo time (UTE) MRI has been proposed as a way to produce segmented attenuation maps for PET, as it provides contrast between bone, air, and soft tissue. However, UTE sequences require samples to be acquired during rapidly changing gradient fields, which makes the resulting images prone to eddy current artifacts. In this work it is demonstrated that this can lead to misclassification of tissues in segmented attenuation maps (AC maps) and that these effects can be corrected for by measuring the true k-space trajectories using a magnetic field camera. Methods: The k-space trajectories during a dual echo UTE sequence were measured using a dynamic magnetic field camera. UTE images were reconstructed using nominal trajectories and again using the measured trajectories. A numerical phantom was used to demonstrate the effect of reconstructing with incorrect trajectories. Images of an ovine leg phantom were reconstructed and segmented and the resulting attenuation maps were compared to a segmented map derived from a CT scan of the same phantom, using the Dice similarity measure. The feasibility of the proposed method was demonstrated inin vivo cranial imaging in five healthy volunteers. Simulated PET data were generated for one volunteer to show the impact of misclassifications on the PET reconstruction. Results: Images of the numerical phantom exhibited blurring and edge artifacts on the bone–tissue and air–tissue interfaces when nominal k-space trajectories were used, leading to misclassification of soft tissue as bone and misclassification of bone as air. Images of the tissue phantom and thein vivo cranial images exhibited the same artifacts. The artifacts were greatly reduced when the measured trajectories were used. For the tissue phantom, the Dice coefficient for bone in MR relative to CT was 0.616 using the nominal trajectories and 0.814 using the measured trajectories. The Dice coefficients for soft tissue were 0.933 and 0.934 for the nominal and measured cases, respectively. For air the corresponding figures were 0.991 and 0.993. Compared to an unattenuated reference image, the mean error in simulated PET uptake in the brain was 9.16% when AC maps derived from nominal trajectories was used, with errors in the SUV{sub max} for simulated lesions in the range of 7.17%–12.19%. Corresponding figures when AC maps derived from measured trajectories were used were 0.34% (mean error) and −0.21% to +1.81% (lesions). Conclusions: Eddy current artifacts in UTE imaging can be corrected for by measuring the true k-space trajectories during a calibration scan and using them in subsequent image reconstructions. This improves the accuracy of segmented PET attenuation maps derived from UTE sequences and subsequent PET reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sol–Gel‐Based Advanced Porous Silica Materials for Biomedical Applications

Abstract Porous silica‐based materials have burgeoning applications ranging from fillers and additives, to adsorbents, catalysts, and recently therapeutic agents and vaccines in nanomedicine. The preponderance of these materials is made by sol–gel processing wherein soluble silica precursors are reacted to form amorphous networks composed of siloxane bonds. The facile sol–gel approach allows for an unlimited variety of binary tertiary and more complex chemical compositions including organic ligands and networks resulting in so‐called organic–inorganic hybrid materials. Here, a brief review of the recent progress in sol–gel‐derived silica materials prepared as particles, thin films, biosilica/silica bioreplicas (of molecules, cells and organisms), and their related preparation, properties, and bioapplications is provided. First, it highlights the recent achievements of mesoporous silica nanoparticles in biomedical applications, including therapeutic agent delivery, multimodal imaging and theranostics, and bone tissue engineering and repair. Second, the research in evaporation‐induced self‐assembly (EISA)‐based mesostructured silica thin films and cell‐directed EISA in bio/nano interfaces for various bioapplications, such as bioactive coatings, biosensing, and living cell immobilization, has been reviewed. Third, the pioneering work in biomimetic silicification/immobilization of biomolecules and bio‐organisms and silica bioreplication of complex bio‐organisms is summarized. Finally, it is concluded with personal perspectives on the directions of future work on this field.

Lei, Qi↗

Preprocessing Prediction of Advanced Algorithms for Medical Imaging

Advanced medical imaging algorithms (such as bone removal, vessel segmentation, or a lung nodule detection) can provide extremely valuable information to the radiologists, but they might sometimes be very time consuming. Being able to run the algorithms in advance can be a possible solution. However, we do not know which algorithm to run on a given dataset before it is actually used. It is possible to manually insert matching rules for preprocessing algorithms, but it requires high maintenance and does not work well in practice. This paper presents a dynamic machine learning solution for predicting which advanced visualization (AV) algorithm needs to be applied on a given series. The system gets a handful of free text DICOM tags as an input and builds a model in the clinical setting. It incorporates a Bag of Words (BOW) feature extractor and a Random Forest classifier. The approach was tested on two datasets from clinical sites which use different languages and varying scanner models. We show that even without feature extraction, sensitivity of above 90% can be reached on both of them. By using BOW feature extractor, precision and sensitivity can usually be further improved. Even on a noisy and highly unbalanced dataset, only around 100 samples were needed to reach sensitivity of above 80% and specificity of above 97%. We show how the solution can be part of a Smart Preprocessing mechanism in a viewing software. Using such a system will ultimately minimize the time to launch studies and improve radiologists reading time efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tip of the Iceberg Findings: Subtle Radiographic Abnormalities Indicating Significant Pathology in the Knee

Purpose of Review: Knee injuries are common and radiographs remain the first line of study in the majority of cases. In many instances, subtle or small radiographic findings actually represent significant underlying pathology that requires expeditious diagnosis and treatment. Recent Findings: By using a mechanistic search strategy, one that applies a comprehensive search for avulsions at ligamentous/tendinous/connective tissue attachments and potential sites of impaction, one may maximize the diagnostic accuracy of radiographic interpretation. Summary: This article will provide a review of important indicators of ligament, tendon, and osseous injuries with an emphasis on their mechanism of injury.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Moderate Hypofractionated Protracted Radiation Therapy and Dose Escalation for Prostate Cancer: Do Dose and Overall Treatment Time Matter?

Purpose: This was a retrospective study of 2 sequential dose escalation regimens of twice-weekly 4 Gy/fractions hypofractionated intensity modulated radiation therapy (IMRT): 56 Gy and 60 Gy delivered within a protracted overall treatment time (OTT) of 6.5 and 7 weeks, respectively. Methods and Materials: 163 prostate cancer patients with cT1c-T3a disease and nodal involvement risk ≤20% (Roach index) were treated twice weekly to the prostate ± seminal vesicles with 2 sequential dose-escalated IMRT schedules: 56 Gy (14 × 4 Gy, n=81) from 2003 to 2007 and 60 Gy (15 × 4 Gy, n=82) from 2006 to 2010. Patient repositioning was made with bone matching on portal images. Gastrointestinal (GI) and genitourinary (GU) toxicities were scored according to the Common Terminology Criteria for Adverse Events version 3.0 grading scale. Results: There were no significant differences regarding the acute GU and GI toxicities in the 2 dose groups. The median follow-up times were 80.2 months (range, 4.5-121 months) and 56.5 months (range, 1.4-91.2 months) for patients treated to 56 and 60 Gy, respectively. The 5-year grade ≥2 late GU toxicity-free survivals with 56 Gy and 60 Gy were 96 ± 2.3% and 78.2 ± 5.1% (P=.001), respectively. The 5-year grade ≥2 late GI toxicity-free survivals with 56 Gy and 60 Gy were 98.6 ± 1.3% and 85.1 ± 4.5% (P=.005), respectively. Patients treated with 56 Gy showed a 5-year biochemical progression-free survival (bPFS) of 80.8 ± 4.7%, worse than patients treated with 60 Gy (93.2 ± 3.9%, P=.007). A trend for a better 5-year distant metastasis-free survival was observed among patients treated in the high-dose group (95.3 ± 2.7% vs 100%, P=.073, respectively). On multivariate analysis, only the 60-Gy group predicted for a better bPFS (P=.016, hazard ratio = 4.58). Conclusions: A single 4-Gy additional fraction in patients treated with a hypofractionated protracted IMRT schedule of 14 × 4 Gy resulted in a similar and minimal acute toxicity, in worse moderate to severe urinary and GI late effects, but a significantly better biochemical control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trace metal analysis by laser ablation-inductively coupled plasmamass spectrometry and x-ray K-edge densitometry of forensic samples

This dissertation describes a variety of studies on the determination of trace elements in samples with forensic importance. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to determine the trace element composition of numerous lipstick samples. Lipstick samples were determined to be homogeneous. Most lipstick samples of similar colors were readily distinguishable at a 95% confidence interval based on trace element composition. Numerous strands of a multi-strand speaker cable were analyzed by LA-ICP-MS. The strands in this study are spatially heterogeneous in trace element composition. In actual forensic applications, the possibility of spatial heterogeneity must be considered, especially in cases where only small samples (e.g., copper wire fragments after an explosion) are available. The effects of many unpredictable variables, such as weather, temperature, and human activity, on the retention of gunshot residue (GSR) around projectile wounds were assessed with LAICP- MS. Skin samples around gunshot and stab wounds and larvae feeding in and around the wounds on decomposing pig carcasses were analyzed for elements consistent with GSR (Sb, Pb, Ba, and Cu). These elements were detected at higher levels in skin and larvae samples around the gunshot wounds compared to the stab wounds for an extended period of time throughout decomposition in both a winter and summer study. After decomposition, radiographic images of the pig bones containing possible damage from bullets revealed metallic particles embedded within a number of bones. Metallic particles within the bones were analyzed with x-ray, K-edge densitometry and determined to contain lead, indicating that bullet residue can be retained throughout decomposition and detected within bones containing projectile trauma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid HIFU autofocusing using the entire MR-ARFI image

Phase aberrations and attenuations caused by bone can defocus HIFU in the brain and organs behind the ribcage. To refocus the beam, MR-ARFI can be used to measure tissue displacements created by each element in the transducer, and optimize driving signal delays and amplitudes. We introduce a new MR-ARFI-based autofocusing method that requires many fewer image acquisitions than current methods. The method is validated in simulations of bone and brain HIFU transducers, and compared to a conventional method.

60 APPLIED LIFE SCIENCES↗

Superior spatial resolution in confocal X-ray techniques using collimating channel array optics: elemental mapping and speciation in archaeological human bone

Confocal X-ray fluorescence imaging (CXFI) and confocal X-ray absorption spectroscopy (CXAS) respectively enable the study of three dimensionally resolved localization and speciation of elements. Applied to a thick sample, essentially any volume element of interest within the X-ray fluorescence escape depth can be examined without the need for physical thin sectioning. To date, X-ray confocal detection generally has employed a polycapillary optic in front of the detector to collect fluorescence from the probe volume formed at the intersection of its focus with the incident microfocus beam. This work demonstrates the capability of a novel Collimating Channel Array (CCA) optic in providing an improved and essentially energy independent depth resolution approaching 2 μm. By presenting a comparison of elemental maps of archaeological bone collected without confocal detection, and with polycapillary- and CCA-based confocal detection, this study highlights the strengths and limitations of each mode. Unlike the polycapillary, the CCA shows similar spatial resolution in maps for both low (Ca) and high (Pb and Sr) energy X-ray fluorescence, thus illustrating the energy independent nature of the CCA optic resolution. While superior spatial resolution is demonstrated for all of these elements, the most significant improvement is observed for Ca, demonstrating the advantage of employing the CCA optic in examining light elements. In addition to CXFI, this configuration also enables the collection of Pb L3 CXAS data from micro-volumes with dimensions comparable to bone microstructures of interest. Our CXAS result, which represents the first CCA-based biological CXAS, demonstrates the ability of CCA optics to collect site specific spectroscopic information. The demonstrated combination of site-specific elemental localization and speciation data will be useful in diverse fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-679: Monte Carlo Simulation On Surface Dose in Preclinical Irradiation Using Monoenergetic Photon Beams

Purpose: This study investigated the surface dose variation in preclinical irradiation using small animal, when monoenergetic photon beams with energy range from 50 keV to 1.25 MeV were used. Methods: Inhomogeneous, homogeneous and bone-tissue homogeneous mouse phantom based on the same CT image set were used. The homogeneous and bone-tissue homogeneous phantom were created with the relative electron density of all and only bone voxels of the mouse overridden to one, respectively. Monte Carlo simulation based on the EGSnrc-based code was used to calculate the surface dose, when the phantoms were irradiated by a 360° photon arc with energies ranging from 50 keV to 1.25 MeV. The mean surface doses of the three phantoms were calculated. In addition, the surface doses from partial arcs, 45°–315°, 125°–225°, 45°–125° and 225°–315° covering the anterior, posterior, right lateral and left lateral region of the mouse were determined using different photon beam energies. Results: When the prescribed dose at the isocenter of the mouse was 2 Gy, the maximum mean surface doses, found at the 50-keV photon beams, were 0.358 Gy, 0.363 Gy and 0.350 Gy for the inhomogeneous, homogeneous and bone-tissue homogeneous mouse phantom, respectively. The mean surface dose of the mouse was found decreasing with an increase of the photon beam energy. For surface dose in different orientations, the lateral regions of the mouse were receiving lower dose than the anterior and posterior regions. This may be due to the increase of beam attenuation along the horizontal (left-right) axis than the vertical (anterior-posterior) in the mouse. Conclusion: It is concluded that consideration of phantom inhomogeneity in the dose calculation resulted in a lower mean surface dose of the mouse. The mean surface dose also decreased with an increase of photon beam energy in the kilovoltage range.

60 APPLIED LIFE SCIENCES↗

Spatial control of perilacunar canalicular remodeling during lactation

Abstract Osteocytes locally remodel their surrounding tissue through perilacunar canalicular remodeling (PLR). During lactation, osteocytes remove minerals to satisfy the metabolic demand, resulting in increased lacunar volume, quantifiable with synchrotron X-ray radiation micro-tomography (SRµCT). Although the effects of lactation on PLR are well-studied, it remains unclear whether PLR occurs uniformly throughout the bone and what mechanisms prevent PLR from undermining bone quality. We used SRµCT imaging to conduct an in-depth spatial analysis of the impact of lactation and osteocyte-intrinsic MMP13 deletion on PLR in murine bone. We found larger lacunae undergoing PLR are located near canals in the mid-cortex or endosteum. We show lactation-induced hypomineralization occurs 14 µm away from lacunar edges, past a hypermineralized barrier. Our findings reveal that osteocyte-intrinsic MMP13 is crucial for lactation-induced PLR near lacunae in the mid-cortex but not for whole-bone resorption. This research highlights the spatial control of PLR on mineral distribution during lactation.

59 BASIC BIOLOGICAL SCIENCES↗

TH-CD-207A-08: Simulated Real-Time Image Guidance for Lung SBRT Patients Using Scatter Imaging

Purpose: To develop a comprehensive Monte Carlo-based model for the acquisition of scatter images of patient anatomy in real-time, during lung SBRT treatment. Methods: During SBRT treatment, images of patient anatomy can be acquired from scattered radiation. To rigorously examine the utility of scatter images for image guidance, a model is developed using MCNP code to simulate scatter images of phantoms and lung cancer patients. The model is validated by comparing experimental and simulated images of phantoms of different complexity. The differentiation between tissue types is investigated by imaging objects of known compositions (water, lung, and bone equivalent). A lung tumor phantom, simulating materials and geometry encountered during lung SBRT treatments, is used to investigate image noise properties for various quantities of delivered radiation (monitor units(MU)). Patient scatter images are simulated using the validated simulation model. 4DCT patient data is converted to an MCNP input geometry accounting for different tissue composition and densities. Lung tumor phantom images acquired with decreasing imaging time (decreasing MU) are used to model the expected noise amplitude in patient scatter images, producing realistic simulated patient scatter images with varying temporal resolution. Results: Image intensity in simulated and experimental scatter images of tissue equivalent objects (water, lung, bone) match within the uncertainty (∼3%). Lung tumor phantom images agree as well. Specifically, tumor-to-lung contrast matches within the uncertainty. The addition of random noise approximating quantum noise in experimental images to simulated patient images shows that scatter images of lung tumors can provide images in as fast as 0.5 seconds with CNR∼2.7. Conclusions: A scatter imaging simulation model is developed and validated using experimental phantom scatter images. Following validation, lung cancer patient scatter images are simulated. These simulated patient images demonstrate the clinical utility of scatter imaging for real-time tumor tracking during lung SBRT.

60 APPLIED LIFE SCIENCES↗

The effect of excitation and preparation pulses on nonslice selective 2D UTE bicomponent analysis of bound and free water in cortical bone at 3T

Purpose: The purpose of this study was to investigate the effect of excitation, fat saturation, long T2 saturation, and adiabatic inversion pulses on ultrashort echo time (UTE) imaging with bicomponent analysis of bound and free water in cortical bone for potential applications in osteoporosis. Methods: Six bovine cortical bones and six human tibial midshaft samples were harvested for this study. Each bone sample was imaged with eight sequences using 2D UTE imaging at 3T with half and hard excitation pulses, without and with fat saturation, long T2 saturation, and adiabatic inversion recovery (IR) preparation pulses. Single- and bicomponent signal models were utilized to calculate the T2{sup *}s and/or relative fractions of short and long T2{sup *}s. Results: For all bone samples UTE T2{sup *} signal decay showed bicomponent behavior. A higher short T2{sup *} fraction was observed on UTE images with hard pulse excitation compared with half pulse excitation (75.6% vs 68.8% in bovine bone, 79.9% vs 73.2% in human bone). Fat saturation pulses slightly reduced the short T2{sup *} fraction relative to regular UTE sequences (5.0% and 2.0% reduction, respectively, with half and hard excitation pulses for bovine bone, 6.3% and 8.2% reduction, respectively, with half and hard excitation pulses for human bone). Long T2 saturation pulses significantly reduced the long T2{sup *} fraction relative to regular UTE sequence (18.9% and 17.2% reduction, respectively, with half and hard excitation pulses for bovine bone, 26.4% and 27.7% reduction, respectively, with half and hard excitation pulses for human bone). With IR-UTE preparation the long T2{sup *} components were significantly reduced relative to regular UTE sequence (75.3% and 66.4% reduction, respectively, with half and hard excitation pulses for bovine bone, 87.7% and 90.3% reduction, respectively, with half and hard excitation pulses for human bone). Conclusions: Bound and free water T2{sup *}s and relative fractions can be assessed using UTE bicomponent analysis. Long T2{sup *} components are affected more by long T2 saturation and IR pulses, and short T2{sup *} components are affected more by fat saturation pulses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-A-BRF-01: Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy

The quantification accuracy of dual-energy imaging is influenced by the fundamentals of x-ray physics, system geometry, data acquisition hardware/protocol, system calibration, and image processing technique. This symposium will provide updates on the following advanced application areas: Mammography. Volumetric breast density techniques based on standard mammograms require estimation of breast thickness, which is difficult to accurately measure. By comparison, calculation of breast density using dual energy mammography does not require measurement of breast thickness. Dual energy mammography has been implemented using both energy integrating flat panel detectors in conjunction with beam energy switching and energy resolved photon counting detectors. These techniques have been optimized using simulation studies and validated using physical phantoms and postmortem breasts. Chemical decomposition was used as the gold standard for volumetric breast density measurement in postmortem breasts. Breast density measurements have also been compared with results from four-category BI-RADS density rankings, standard image thresholding and Fuzzy k-mean clustering techniques. These studies indicate that dual energy mammography can be used to accurately measure volumetric breast density. Cardiovascular CT. The predicative accuracy of risk models for recurrent stroke and cardiac arrest depends heavily on accurate differentiation of thrombus or calcium from iodine in left atrial appendage or coronary arteries. The amount of energy separation is constrained by image noise; therefore, optimal kVp, beam filtration, and balanced flux are essential for the quantification accuracy of iodine and calcium. The basis materials are combined linearly to generate monochromatic energy images, where CT# accuracy and CNR are energy dependent. With optimal monochromatic energy, the mean iodine concentration for the thrombus, circulatory stasis, and control groups are significantly different. Risk classification based on calcium scores shows excellent agreement with classification on the basis of conventional coronary artery calcium scoring. These studies demonstrate dual-energy cardiovascular CT can potentially be a noninvasive and sensitive modality in high risk patients. On-board KV/MV Imaging. To enhance soft tissue contrast and reduce metal artifacts, we have developed a dual-energy CBCT technique and a novel on-board kV/MV imaging technique based on hardware available on modern linear accelerators. We have also evaluated the feasibility of these two techniques in various phantom studies. Optimal techniques (energy, beam filtration, # of overlapping projections, etc) have been investigated with unique calibration procedures, which leads to successful decomposition of imaged material into acrylic-aluminum basis material pair. This enables the synthesis of virtual monochromatic (VM) CBCT images that demonstrate much less beam hardening, significantly reduced metal artifacts, and/or higher soft tissue CNR compared to single-energy CBCT. Adaptive Radiation Therapy. DECT could actually contribute to the area of Dose-Guided Radiation Therapy (or Adaptive Therapy). The application of DECT imaging using 80kV and 140 kV combinations could potentially increase the image quality by reducing the bone or high density material artifacts and also increase the soft tissue contrast by a light contrast agent. The result of this higher contrast / quality images is beneficial for deformable image registration / segmentation algorithm to improve its accuracy hence to make adaptive therapy less time consuming in its recontouring process. The real time re-planning prior to per treatment fraction could become more realistic with this improvement especially in hypofractional SBRT cases. Learning Objectives: Learn recent developments of dual-energy imaging in diagnosis and radiation therapy; Understand the unique clinical problem and required quantification accuracy in each application; Understand the different approaches to optimize dual-energy imaging techniques for different applications.

60 APPLIED LIFE SCIENCES↗