Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building energy simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

From roads to roofs: How urban and rural mobility influence building energy consumption

In this article, understanding the relationship between travel behavior and building energy use at an urban scale is crucial for developing effective energy management strategies. Mobility patterns significantly impact building occupancy, which in turn affects energy consumption. However, existing methods often focus on individual buildings, whereas geographical influences on energy usage are not adequately examined. This study addresses this gap by using transportation origin-destination (OD) data to estimate building occupancy and energy. The proposed method assigns OD trips from census block groups to the building level, incorporating building, travel survey, and census data to derive building occupancy profiles. This method was applied to urban and rural areas with 4062 buildings in 70 census block groups. We found that the OD-informed occupancy profile exhibits smoother energy consumption patterns compared with that of Department of Energy reference occupancy profiles. Our analysis reveals distinct building energy consumption patterns among groups with long and short commutes, emphasizing the effect of commute times and work schedules on residential energy usage. This framework is useful for practitioners in transportation agencies and utility companies, enabling the estimation of building energy based on mobility patterns. Overall, this study shows the potential of integrating transportation and building energy data to inform cross-sector energy management strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

Status of Marshall Space Flight Center solar house

The Marshall Space Flight Center (MSFC) solar facility is described herein, and test results obtained from late May 1974 to September 1974 are discussed. This facility was assembled to provide operational experience in the utilization of solar energy for heating and cooling buildings. The major subsystems are the solar collector, the energy storage tank, the simulated living space, the air conditioning and heating subsystems, and the controls. These subsystems are described with emphasis placed on major results and conclusions. A cursory evaluation of the system for cooling is given from energy and power consumption viewpoints. This data evaluation indicates the current system is capable of supplying 50 per cent of the thermal energy required to drive the air conditioner. A preliminary evaluation of winter data indicates that more than 90 per cent of the heating required can be provided by the solar system.

Humphries, W. R.↗

An Assessment of Actual and Potential Building Climate Zone Change and Variability From the Last 30 Years Through 2100 Using NASA's MERRA and CMIP5 Simulations

Background: In the US, residential and commercial building infrastructure combined consumes about 40% of total energy usage and emits about 39% of total CO2 emission (DOE/EIA "Annual Energy Outlook 2013"). Building codes, as used by local and state enforcement entities are typically tied to the dominant climate within an enforcement jurisdiction classified according to various climate zones. These climate zones are based upon a 30-year average of local surface observations and are developed by DOE and ASHRAE. Establishing the current variability and potential changes to future building climate zones is very important for increasing the energy efficiency of buildings and reducing energy costs and emissions in the future. Objectives: This paper demonstrates the usefulness of using NASA's Modern Era Retrospective-analysis for Research and Applications (MERRA) atmospheric data assimilation to derive the DOE/ASHRAE building climate zone maps and then using MERRA to define the last 30 years of variability in climate zones for the Continental US. An atmospheric assimilation is a global atmospheric model optimized to satellite, atmospheric and surface in situ measurements. Using MERRA as a baseline, we then evaluate the latest Climate Model Inter-comparison Project (CMIP) climate model Version 5 runs to assess potential variability in future climate zones under various assumptions. Methods: We derive DOE/ASHRAE building climate zones using surface and temperature data products from MERRA. We assess these zones using the uncertainties derived by comparison to surface measurements. Using statistical tests, we evaluate variability of the climate zones in time and assess areas in the continental US for statistically significant trends by region. CMIP 5 produced a data base of over two dozen detailed climate model runs under various greenhouse gas forcing assumptions. We evaluate the variation in building climate zones for 3 different decades using an ensemble and quartile statistics to provide an assessment of potential building climate zone changes relative to the uncertainties demonstrated using MERRA. Findings and Conclusions: These results show that there is a statistically significant increase in the area covered by warmer climate zones and a tendency for a reduction of area in colder climate zones in some limited regions. The CMIP analysis shows that models vary from relatively little building climate zone change for the least sensitive and conservation assumptions to a warming of at most 3 zones for certain areas, particularly the north central US by the end of the 21st century.

Stackhouse, Paul W., Jr.↗

Designing reinforcement learning algorithms for building HVAC control: From experimental observation to simulation comparisons

Advanced supervisory-level control with reinforcement learning (RL) is regarded as a promising solution for HVAC systems to minimize energy consumption while maintaining thermal comfort and indoor air quality. However, most RL applications were conducted in the simulation environment rather than real-world HVAC systems. This paper developed a value-based RL controller termed Deep Q-Network (DQN) for a typical central HVAC system and evaluated its performance in a building test facility. By comparing DQN with a rule-based controller, the study not only demonstrated the cases where DQN could properly maintain indoor comfort but also discussed possible reasons why DQN failed in some other situations. Recognizing the limitations of value-based RL algorithms from the experimental tests, a simulation study was conducted to compare DQN with an alternative RL approach, an actor–critic algorithm termed Deep Deterministic Policy Gradient (DDPG). In scenarios with a relatively large action space, DDPG outperformed DQN by requiring fewer computational resources and achieving better thermal comfort, lower energy consumption, and more stable control actions. The findings suggest that the ability of DDPG to handle continuous control variables more effectively allows for faster convergence in training and more precise control in practice, which enhances the overall efficiency and reliability of the HVAC system.

Guo, Fangzhou↗

Validation and Calibration of Energy Models with Real Vehicle Data from Chassis Dynamometer Experiments

Accurate estimation of vehicle fuel consumption typically requires detailed modeling of complex internal powertrain dynamics, often resulting in computationally intensive simulations. However, many transportation applications-such as traffic flow modeling, optimization, and control-require simplified models that are fast, interpretable, and easy to implement, while still maintaining fidelity to physical energy behavior. This work builds upon a recently developed model reduction pipeline that derives physics-like energy models from high-fidelity Autonomie vehicle simulations. These reduced models preserve essential vehicle dynamics, enabling realistic fuel consumption estimation with minimal computational overhead. While the reduced models have demonstrated strong agreement with their Autonomie counterparts, previous validation efforts have been confined to simulation environments. This study extends the validation by comparing the reduced energy model's outputs against real-world vehicle data. Focusing on the MidSUV category, we tune the baseline Autonomie model to closely replicate the characteristics of a Toyota RAV4. We then assess the accuracy of the resulting reduced model in estimating fuel consumption under actual drive conditions. Our findings suggest that, when the reference Autonomie model is properly calibrated, the simplified model produced by the reduction pipeline can provide reliable, semi-principled fuel rate estimates suitable for large-scale transportation applications.

42 ENGINEERING↗

Development of a Sizing and Modeling Platform for District Energy Systems with Geothermal Heat Pumps

Existing tools for community or urban scale energy system modeling and simulation are often limited in their capabilities and require expert-level modeling proficiency to develop system models. To fill this gap, this paper proposes an integrated sizing and modeling platform for district energy systems with geothermal heat pumps. The proposed platform takes in geometric and non-geometric user inputs related to the buildings, borefield, and district energy loop. Then, the platform sizes the geothermal heat exchanger, generates a corresponding district energy system model, and runs an annual simulation automatically. We validated the simulation performance of the borefield in our tool against EnergyPlus. A case study is provided in this paper to demonstrate the workflow and simulation result plausibility of the proposed platform.

decarbonization↗

Geothermal Power Systems Analysis: Outcome of Industry Stakeholders Workshop: Preprint

Geothermal cost and performance evaluation implemented via technoeconomic assessment (TEA) modeling is critical for the Department of Energy (DOE) and other geothermal industry stakeholders in assessing the current state of geothermal technologies and to identify existing hurdles to commercially viable geothermal development. The Geothermal Electricity Technology Evaluation Model (GETEM) is a major TEA tool used in estimating the economic feasibility and levelized cost of energy (LCOE) of conventional hydrothermal systems and enhanced geothermal systems (EGS). Since 2021, GETEM has been transitioning from an intricate spreadsheet model to a user-friendly tool within the System Advisor Model (SAM) developed by the National Renewable Energy Laboratory (NREL). Apart from enabling an expanded visibility of the geothermal model among other renewable resources, having GETEM in SAM has the advantage of simulation automation, better usability, updates tracking, active user inputs/feedback, and extended financial modeling. GETEM is used in developing supply curves for the Annual Technology Baseline (ATB). The ATB data are inputs to the Renewable Energy Potential (reV) and the Regional Energy Deployment System (ReEDS) models. The geothermal module in NREL’s reV model assesses the geothermal energy potential in the conterminous United States by defining the geospatial intersection of geothermal resources with existing grid infrastructure within the constraint of land use characteristics. The ReEDS model is a capacity expansion model used for simulating the long-term build-out and operation of the US generation and transmission system based on current energy costs and policies. To ensure enhanced representation of current industry trends in our model transitions and development, we organized a two-day virtual workshop to elicit geothermal industry stakeholder input and recommendations on our current approaches and assumptions on technoeconomic, resource assessment, and deployment scenarios modeling of geothermal technologies. Participants included developers, operators, investors, regulatory agencies, system modelers, national laboratory researchers, consultants, and other stakeholders. In this workshop, we gained stakeholder insights on current geothermal plant performance (i.e., capacity factors), updated drilling costs and learning curves, and next generation technologies such as closed loop and superhot rock geothermal. Other outcomes from this workshop and its impact on future geothermal development feasibility, resource availability, and capacity expansion studies are compiled and discussed.

Annual Technology Baseline↗

Geothermal Power Systems Analysis: Outcome of Industry Stakeholders Workshop

Geothermal cost and performance evaluation implemented via techno-economic assessment (TEA) modeling is critical for the U.S. Department of Energy (DOE) and other geothermal industry stakeholders in assessing the current state of geothermal technologies and to identify existing hurdles to commercially viable geothermal development. The Geothermal Electricity Technology Evaluation Model (GETEM) is a major TEA tool used in estimating the economic feasibility and levelized cost of energy (LCOE) of conventional hydrothermal systems and enhanced geothermal systems (EGS). Since 2021, GETEM has been transitioning from an intricate spreadsheet model to a user-friendly tool within the System Advisor Model (SAM) developed by the National Renewable Energy Laboratory (NREL). Apart from enabling an expanded visibility of the geothermal model among other renewable resources, having GETEM in SAM has the advantage of simulation automation, better usability, updates tracking, active user inputs/feedback, and extended financial modeling. GETEM is used in developing supply curves for NREL's Annual Technology Baseline (ATB), which provides inputs to the Renewable Energy Potential (reV) and the Regional Energy Deployment System (ReEDS) models. The geothermal module in NREL's reV model assesses the geothermal energy potential in the conterminous United States by defining the geospatial intersection of geothermal resources with existing grid infrastructure within the constraint of land use characteristics. The ReEDS model is a capacity expansion model used for simulating the long-term build-out and operation of the U.S. generation and transmission system based on current energy costs and policies. To ensure enhanced representation of current industry trends in our model transitions and development, we organized a two-day virtual workshop to elicit geothermal industry stakeholder input and recommendations on our current approaches and assumptions on techno-economic, resource assessment, and deployment scenarios modeling of geothermal technologies. Participants included developers, operators, investors, regulatory agencies, system modelers, national laboratory researchers, consultants, and other stakeholders. In this workshop, we gained stakeholder insights on current geothermal plant performance (i.e., capacity factors), updated drilling costs and learning curves, and next-generation technologies such as closed-loop and superhot rock geothermal. Other outcomes from this workshop and its impact on future geothermal development feasibility, resource availability, and capacity expansion studies are compiled and discussed.

annual technology baseline↗

Integrating adaptive learning with post hoc model explanation and symbolic regression to build interpretable surrogate models

Abstract We develop a materials informatics workflow to build an interpretable surrogate model for micromagnetic simulations. Our goal is to predict the energy barrier of a moving isolated skyrmion in rare-earth-free $$\hbox {Mn}_4$$ Mn 4 N. Our approach integrates adaptive learning with post hoc model explanation and symbolic regression methods. We discuss an unexplored acquisition function (information condensing active learning) within the adaptive learning loop and compare it with the known standard deviation function for efficient navigation of the search space. Model-agnostic post hoc explanation techniques then uncover trends learned by the trained model, which we then leverage to constrain the expressions used for symbolic regression. Graphical abstract

Biswas, Ankita↗

Progress on 3D SRF-based architecture for quantum computing

Superconducting radio frequency (SRF) cavities are excellent choices for storing and manipulating quantum information as quantum d-level systems (qudits) due to their exceptionally long lifetimes and large accessible Hilbert spaces. A common strategy to manipulate the states is to use a nonlinear element like a transmon. We present preliminary experimental results obtained with cavity displacements and selective number dependent arbitrary phase gates for universal qudit control, and its application towards High-energy physics (HEP) simulations and beyond. We discuss the advantages and challenges associated with building a 3D SRF architecture while maintaining long cavity lifetimes in the presence of lossy components. We show how the system coherence properties can be preserved by carefully engineering to minimize the participation of the long coherence modes in different loss channels, while ensuring sufficient quantum controllability. We further discuss the path towards building multi-qudit systems.

Romanenko, Alexander↗

DECAL MDN Resolution Calibration

The simulated pixelated calorimeter uses 0.1 mm × 0.1 mm silicon pixels (0.0001 cm²) silicon pixels as active layers — far finer than current concepts like HGCAL (~0.5 cm²) — improving energy resolution through much finer segmentation. While the standard resolution formalism fits three numbers to a handful of discrete test-beam energies, this work is a first try at a more data-efficient alternative: learning the full response shape continuously in energy with a mixture density network. This continuous, differentiable surrogate is a natural building block for fast simulation of extremely complex calorimeters.

Wang, Peter [U. Chicago (main)]↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Cosmology with second- and third-order shear statistics for the Dark Energy Survey: Methods and simulated analysis

We present a new pipeline designed for the robust inference of cosmological parameters using both second- and third-order shear statistics. We build a theoretical model for rapid evaluation of three-point correlations using our fastnc code and integrate it into the cosmosis framework. We measure the two-point functions 𝜉 ± and the full configuration-dependent three-point shear correlation functions across all auto- and cross-redshift bins. We compress the three-point functions into the mass aperture statistic ⟨ℳ$^{3}_{ap}$⟩ for a set of 796 simulated shear maps designed to model the Dark Energy Survey Year 3 data. We estimate from it the full covariance matrix and model the effects of intrinsic alignments, shear calibration biases and photometric redshift uncertainties. We apply scale cuts to minimize the contamination from the baryonic signal as modeled through hydrodynamical simulations. We find a significant improvement of 83% on the figure of merit in the Ω m − 𝑆 8 plane when we add the ⟨ℳ$^{3}_{ap}$⟩ data to 𝜉 ± . Here, we present our findings for all relevant cosmological and systematic uncertainty parameters and discuss the complementarity of third-order and second-order statistics.

79 ASTRONOMY AND ASTROPHYSICS↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulations of Hyperthermal Oxygen Beam Exposures

Pulsed sources of hyper-thermal O-atoms are now being extensively used to simulate low-earth orbit (LEO) surface exposure environments. The peak flux of these sources is many orders of magnitude larger than the corresponding LEO flux. Although it is desirable to accelerate the test by using higher fluxes than found in LEO, even commonly used fluxes are large enough to produce multi-collision effects by causing a build-up of gas at the sample surface. In this paper we characterize the physical consequences to the experiment using the direct simulation Monte Carlo (DSMC) method, DSMC allows us to extract the distributions of energy and impact angle for the O-atoms that reach the surface, and to record how strongly the gas build-up at the target assembly deflects flux from downstream instrumentation. By considering a range of source fluxes, we determine the onset conditions and severity of these multi-collision effects. We find that even at common experimental fluxes with a normally incident beam string a flat surface sample, the energy distribution of incident O-atoms broadens and develops a significant low-energy tail. The angular distributions also broaden significantly. The number of O-atoms that reach downstream instrumentation is decreased by approximately 50%. These simulations will aid in the calibration of ground-based O-atom measurements,a nd provide a model for the energy and angular distributions of O-atoms that actually impinge on surface samples.

Finchum, A.↗

DSMC Simulations of Hyperthermal Oxygen Beam Exposures

Pulsed sources of hyper-thermal O-atoms are now being extensively used to simulate low-earth orbit (LEO) surface exposure environments. The peak flux of these sources is many orders of magnitude larger than the corresponding LEO flux. Although it is desirable to accelerate the test by using higher fluxes than found in LEO, even commonly used fluxes are large enough to produce multi-collision effects by causing a build-up of gas at the sample surface. In this paper we characterize the physical consequences to the experiment using the direct simulation Monte Carlo (DSMC) method. DSMC allows us to extract the distributions of energy and impact angle for the O-atoms that reach the surface, and to record how strongly the gas build-up at the target assembly deflects flux from downstream instrumentation. By considering a range of source fluxes, we determine the onset conditions and severity of these multi-collision effects. We find that even at common experimental fluxes with a normally incident beam striking a flat surface sample, the energy distribution of incident O-atoms broadens and develops a significant low-energy tail. The angular distributions also broaden significantly. The number of O-atoms that reach downstream instrumentation is decreased by approximately 50%. These simulations will aid in the calibration of ground-based O-atom measurements, and provide a model for the energy and angular distributions of O-atoms that actually impinge on surface samples.

Cline, Jason A.↗

Pragmatic Stress Prediction on Additively Manufactured Coupons

Prediction of residual stresses from process parameters for additively manufactured large metal parts is computationally expensive. NASA is currently developing meter-scale parts with direct energy deposition. Practically, the predictive computational methods need to efficiently scale-up to meter-scale parts. Coupled thermal-mechanical multi-physics simulations have been developed with the pragmatic method using ABAQUS, COMSOL Multiphysics, ALE3D software. The residual stresses are a result of the manufacturing process which creates thermal cycling of the build layers. The pragmatic method uses lumped thermal layers for stress predictions to reduce computational costs. The stress predictions as well as deformations of the different codes are compared with each other and with ANSYS Additive using identical material models, boundary and initial conditions. The codes were used to simulate three different geometries: a thin wall, hollow cylinder and twin-cantilever part. The coupon parts were then manufactured with Inconel-625. The residual stresses in these parts were measured using X-ray diffraction as well as neutron beam diffraction at NIST. The stress measurements for the two technologies are compared. The pragmatic stress prediction method enabled predictions of the multi-centimeter scale parts using desktop computer workstations in only a few hours for each coupon. The results of the simulated stress predictions compared favorably with the measured stresses even though thermally lumped layers were employed. Finally, a two-meter scale nozzle was simulated using ANSYS Additive. The simulations were used to examine the build orientation trade-space with respect to resulting geometric deformation. The predicted deformations were compared to measurements of an actual subscale part manufactured with direct energy deposition.

Additive Manufacturing↗