Search NASA⌕ Search

SEARCH · Search NASA

Results for “Burgers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Laser ablation spectrometry for studies of uranium plasmas, reactor monitoring, and spent fuel safety

Nuclear security is one of the defining challenges of our time. Nuclear threats range from deliberate dispersal of radioactive material to contaminate the vital infrastructure to diversion and smuggling of special nuclear material for clandestine nuclear programs and nuclear terrorism, respectively. There is an associated need to develop and sustain the nuclear forensics capabilities, which requires the understanding of complex processes that occur in plasmas of nuclear materials. The area of nuclear safety has seen a resurgence of public interest, and there is a concomitant need to safely store used nuclear fuel and detect structural material failure in nuclear power systems, especially in innovative reactor designs envisioned for future adoption. Laser-produced plasmas are complicated extreme environments that can generate intense and rich, highly specific signatures of nuclear and radiological materials, which can then be explored in a wide range of applications. They include interdiction and rapid detection of nuclear materials, including their isotopic composition, detection over long distances, laboratory simulation of weapons effects, monitoring the condition of structural materials in dry cask storage containers, and novel instrumentation for nuclear power systems. We present a compilation of recent representative examples of the application of laser spectroscopy, and laser-induced breakdown spectroscopy in particular, to nuclear safety and security problems. A case is made that spectroscopic techniques based on laser-produced plasmas offer complementary, and sometimes unique, capabilities that motivate the continued exploration of their efficient production and understanding of the signatures they produce

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Temporal Structures in Positron Spectra and Charge-Sign Effects in Galactic Cosmic Rays

We present the precision measurements of 11 years of daily cosmic positron fluxes in the rigidity range from 1.00 to 41.9 GV based on 3.4 × 10 6 positrons collected with the Alpha Magnetic Spectrometer (AMS) aboard the International Space Station. The positron fluxes show distinctly different time variations from the electron fluxes at short and long timescales. A hysteresis between the electron fluxes and the positron fluxes is observed with a significance greater than 5⁢𝜎 at rigidities below 8.5 GV. On the contrary, the positron fluxes and the proton fluxes show similar time variation. Remarkably, we found that positron fluxes are modulated more than proton fluxes with a significance greater than 5⁢𝜎 for rigidities below 7 GV. These continuous daily positron fluxes, together with AMS daily electron, proton, and helium fluxes over an 11-year solar cycle, provide unique input to the understanding of both the charge-sign and mass dependencies of cosmic rays in the heliosphere.

astroparticles↗

Properties of Cosmic Deuterons Measured by the Alpha Magnetic Spectrometer

Precision measurements by the Alpha Magnetic Spectrometer (AMS) on the International Space Station of the deuteron (𝐷) flux are presented. The measurements are based on 21 × 10 6 𝐷 nuclei in the rigidity range from 1.9 to 21 GV collected from May 2011 to April 2021. We observe that over the entire rigidity range the 𝐷 flux exhibits nearly identical time variations with the 𝑝, 3 He, and 4 He fluxes. Above 4.5 GV, the 𝐷/ 4 He flux ratio is time independent and its rigidity dependence is well described by a single power law ∝𝑅 Δ with Δ 𝐷/ 4 He = −0.108 ± 0.005. This is in contrast with the 3 He/ 4 He flux ratio for which we find Δ 3 He/ 4 He = −0.289 ± 0.003. Above ∼13 GV we find a nearly identical rigidity dependence of the 𝐷 and 𝑝 fluxes with a 𝐷/𝑝 flux ratio of 0.027 ± 0.001. These unexpected observations indicate that cosmic deuterons have a sizable primarylike component. With a method independent of cosmic ray propagation, we obtain the primary component of the 𝐷 flux equal to 9.4 ± 0.5% of the 4 He flux and the secondary component of the 𝐷 flux equal to 58 ± 5% of the 3 He flux.

cosmic ray acceleration↗

Solar Modulation of Cosmic Nuclei over a Solar Cycle: Results from the Alpha Magnetic Spectrometer

We report the properties of precision time structures of cosmic nuclei He, Li, Be, B, C, N, and O fluxes over an 11-year solar cycle from May 2011 to November 2022 in the rigidity range from 1.92 to 60.3 GV. The nuclei fluxes show similar but not identical time variations with amplitudes decreasing with increasing rigidity. In particular, below 3.64 GV the Li, Be, and B fluxes, and below 2.15 GV the C, N, and O fluxes, are significantly less affected by solar modulation than the He flux. We observe that these differences in solar modulation are linearly correlated with the differences in the spectral indices of the cosmic nuclei fluxes. This shows, in a model-independent way, that solar modulation of galactic cosmic nuclei depends on their spectral shape. In addition, solar modulation differences due to nuclei velocity dependence on the mass-to-charge ratio (𝐴/𝑍) are not observed.

cosmic ray composition & spectra↗

Antiprotons and Elementary Particles over a Solar Cycle: Results from the Alpha Magnetic Spectrometer

We present results over an 11-year Solar cycle of cosmic antiprotons based on 1.1 × 10 6 events in the rigidity range from 1.00 to 41.9 GV. The $\bar{𝑝}$ fluxes exhibit distinct properties. The magnitude of the $\bar{𝑝}$ flux temporal variation is significantly smaller than those of 𝑝, 𝑒 − , and 𝑒 + . A hysteresis between the $\bar{𝑝}$ fluxes and the 𝑝 fluxes is observed, whereas the $\bar{𝑝}$ and 𝑒 − fluxes show a linear correlation. With a model-independent analysis, we found a universal relation between the shape of the rigidity spectrum and the magnitude of flux temporal variation over an 11-year Solar cycle for both positively and negatively charged particles. The simultaneous results on $\bar{𝑝}$ and 𝑝, 𝑒 − , and 𝑒 + provide unique information for understanding particle transport in the Solar System as a function of mass, charge, and spectral shape.

cosmic ray composition & spectra↗

Properties of Cosmic Lithium Isotopes Measured by the Alpha Magnetic Spectrometer

We present the first measurement of cosmic-ray fluxes of 6 Li and 7 Li isotopes in the rigidity range from 1.9 to 25 GV. The measurements are based on 9.7 × 10 5 6 Li and 1.04 × 10 6 7 Li nuclei collected by the Alpha Magnetic Spectrometer on the International Space Station from May 2011 to October 2023. We observe that over the entire rigidity range the 6 Li and 7 Li fluxes exhibit nearly identical time variations and, above ∼4 GV, the time variations of 6 Li , 7 Li , He, Be, B, C, N, and O fluxes are identical. Above ∼7 GV, we find an identical rigidity dependence of the 6 Li and 7 Li fluxes. This shows that they are both produced by collisions of heavier cosmic-ray nuclei with the interstellar medium and, in particular, excludes the existence of a sizable primary component in the 7 Li flux.

cosmic ray acceleration↗

Using Temporal Information from Human Mobility Data to Detect Anchor Points

Spatiotemporal mobility data are available in massive quantities, but large quantities of data typically include fewer variables or data fields. Often, the only available fields are User ID, Longitude, Latitude, Timestamp (ULLT). This raises an important question: how much can we infer about human mobility patterns using only these four fields? With ULLT data, we do not know individuals' socioeconomic status information or when they are visiting their anchor points (AP) or locations (such as homes, places of employment, or schools), and it is a modern challenge to use this data to infer these characteristics. When detecting anchor locations with limited input information, verification and validation (VV) are significant challenges. This paper addresses the problem of identifying individuals' anchor locations using only temporal information from spatiotemporal datasets with limited attributes. Our approach does not explicitly use latitude and longitude during analysis. Locationbased information is only employed in the preprocessing stage to identify periods of movement (trips) and stops (dwelling). Beyond this step, all analysis is based on temporal patterns. In theory, if stops and dwell times could be detected through alternative means, our method could function entirely without location-based input. We demonstrate this methodology on the 2017 National Household Travel Survey (NHTS) data, because it includes a carefully designed and collected time use survey with representative sampling and labeled ground truth. The high-quality survey data allows us to test the accuracy of our methods because NHTS contains intended place labels and agent/user characteristics. We have also applied our validated AP identification algorithm on very large-scale GPS based trajectory data for Patterns-of-Life (PoL) assessment and other applications, but due to space limit that could not be presented here.

McBride, Liz [ORNL] (ORCID:0000000286925869)↗

Unraveling the Stable Cathode Electrolyte Interface in all Solid‐State Thin‐Film Battery Operating at 5 V

Abstract Spinel‐type LiNi 0.5 Mn 1.5 O 4 (LNMO) is one of the most promising 5 V‐class cathode materials for Li‐ion batteries that can achieve high energy density and low production costs. However, in liquid electrolyte cells, the high voltage causes continuous cell degradation through the oxidative decomposition of carbonate‐based liquid electrolytes. In contrast, some solid‐state electrolytes have a wide electrochemical stability range and can withstand the required oxidative potential. In this work, a thin‐film battery consisting of an LNMO cathode with a solid lithium phosphorus oxynitride (LiPON) electrolyte is tested and their interface before and after cycling is characterized. With Li metal as the anode, this system can deliver stable performance for 600 cycles with an average Coulombic efficiency >99%. Neutron depth profiling indicates a slight overlithiated layer at the interface prior to cycling, a result that is consistent with the excess charge capacity measured during the first cycle. Cryogenic electron microscopy further reveals intimate contact between LNMO and LiPON without noticeable structure and chemical composition evolution after extended cycling, demonstrating the superior stability of LiPON against a high voltage cathode. Consequently, design guidelines are proposed for interface engineering that can accelerate the commercialization of a high voltage cell with solid or liquid electrolytes.

25 ENERGY STORAGE↗

False positive PSMA PET for tumor remnants in the irradiated prostate and other interpretation pitfalls in a prospective multi-center trial

Readers need to be informed about potential pitfalls of [ 68 Ga]Ga-PSMA-11 PET interpretation. Here we report [ 68 Ga]Ga-PSMA-11 PET findings discordant with the histopathology/composite reference standard in a recently published prospective trial on 635 patients with biochemically recurrent prostate cancer. Consensus reads were false positive in 20 regions of 17/217 (8%) patients with lesion validation. Majority of the false positive interpretations (13 of 20, 65%) occurred in the context of suspected prostate (bed) relapse (T) after radiotherapy ( n = 11); other false positive findings were noted for prostate bed post prostatectomy (T, n = 2), pelvic nodes (N, n = 2), or extra pelvic lesions (M, n = 5). Major sources of false positive findings were PSMA-expressing residual adenocarcinoma with marked post-radiotherapy treatment effect. False negative interpretation occurred in 8 regions of 6/79 (8%) patients with histopathology validation, including prostate (bed) ( n = 5), pelvic nodes ( n = 1), and extra pelvic lesions ( n = 2). Lesions were missed mostly due to small metastases or adjacent bladder/urine uptake.[ 68 Ga]Ga-PSMA-11 PET at biochemical recurrence resulted in less than 10% false positive interpretations. Post-radiotherapy prostate uptake was a major source of [ 68 Ga]Ga-PSMA-11 PET false positivity. In few cases, PET correctly detects residual PSMA expression post-radiotherapy, originating however from treated, benign tissue or potentially indolent tumor remnants.

Radiology, Nuclear Medicine & Medical Imaging↗