Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Radiation scales on which standard values of the solar constant and solar spectral irradiance are based

The question of radiation scales is critically examined. There are two radiation scales which are of fundamental validity and there are several calibration standards and radiation scales which have been set up for practical convenience. The interrelation between these scales is investigated. It is shown that within the limits of accuracy of irradiance measurements in general and solar irradiance measurements in particular, the proposed standard values of the solar constant and solar spectrum should be considered to be on radiation scales of fundamental validity; those based on absolute electrical units and on the thermodynamic Kelvin temperature scale.

Thekaekara, M. P.↗

Comparison of the calculated absorbed dose using the Cadplan™ treatment planning software and Tld-100 measurements in an Alderson-Rando phantom for a bronchogenic treatment

To verify the accuracy of the absorbed doses D calculated by a TPS Cadplan for a bronchogenic treatment (in an Alderson-Rando phantom) are chosen ten points with the following D's and localizations. Point 1, posterior position on the left edge with 136.4 Gy. Points: 2, 3 and 4 in the left lung with 104.9, 104.3 and 105.8 Gy, respectively; points 5 and 6 at the mediastinum with 192.4 and 173.5 Gy; points 7, 8 and 9 in the right lung with 105.8, 104.2 and 104.7 Gy, and 10 at posterior position on right edge with 143.7 Gy. IAEA type capsules with TLD 100 powder are placed, planned and irradiated. The evaluation of the absorbed dose is carried out a curve of calibration for the LiF response (nC) {sup vs} {sup DW}, to several cavity theories. The traceability for the DW is obtained with a secondary standard calibrated at the NRC (Canada). The dosimetric properties for the materials considered are determined from the Hounsfield numbers reported by the TPS. The stopping power ratios are calculated for nominal spectrum to 6 MV photons. The percent variations among the planned and determined D in all the cases they are < ± 3%.

60 APPLIED LIFE SCIENCES↗

Status of Photovoltaic Calibration and Measurement Standards

The 7th International Workshop on Space Solar Cell Calibration and Measurement was held on September 25-27, 2000 in Girdwood, Alaska. Representatives from eight countries discussed international standards for single and multijunction solar cell measurement and calibration methods, round robin intercomparisons, and irradiation test methods for space solar cells. Progress toward adoption of an ISO standard on single junction cells was made. Agreement was reached to begin work on new standards for multijunction cells and irradiation testing. Progress on present single junction round robin measurements was discussed and future multijunction round robins were planned. The next workshop will be held in Germany in October 2001.

Baraona, Cosmo↗

BRDF Calibration of Sintered PTFE in the SWIR

Satellite instruments operating in the reflective solar wavelength region often require accurate and precise determination of the Bidirectional Reflectance Distribution Function (BRDF) of laboratory-based diffusers used in their pre-flight calibrations and ground-based support of on-orbit remote sensing instruments. The Diffuser Calibration Facility at NASA's Goddard Space Flight Center is a secondary diffuser calibration standard after NEST for over two decades, providing numerous NASA projects with BRDF data in the UV, Visible and the NIR spectral regions. Currently the Diffuser Calibration Facility extended the covered spectral range from 900 nm up to 1.7 microns. The measurements were made using the existing scatterometer by replacing the Si photodiode based receiver with an InGaAs-based one. The BRDF data was recorded at normal incidence and scatter zenith angles from 10 to 60 deg. Tunable coherent light source was setup. Broadband light source application is under development. Gray-scale sintered PTFE samples were used at these first trials, illuminated with P and S polarized incident light. The results are discussed and compared to empirically generated BRDF data from simple model based on 8 deg directional/hemispherical measurements.

Georgiev, Georgi T.↗

High Altitude Measurements of Radiance at High Spectral and Spatial Resolution for SIMBIOS Sensor Calibration, Validation, and Intercomparisons

The successful combination of data from different ocean color sensors depends on the correct interpretation of signal from each of these sensors. Ideally, the sensor measured signals are calibrated to geophysical units of spectral radiance, and sensor artifacts are removed and corrected. The calibration process resamples the signal into a common radiometric data space so that subsequent ocean color algorithms that are applied to the data are based on physical processes and are inherently sensor independent. The objective of this project is to calibrate and validate the on-orbit radiometric characteristics of Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) with underflights of NASA's calibrated Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This objective is feasible because AVIRIS measures the same spectral range as SeaWIFS at higher spectral resolution. In addition to satellite sensor underflights, the AVIRIS project has supported comparison and analysis of the radiometric calibration standards used for AVIRIS and SeaWIFS. To date, both the OCTS and SeaWIFS satellite sensors have been underflown by AVIRIS with matching spectral, spatial, geometric, radiometric, and temporal domains. The calibration and validation objective of this project is pursued for the following reasons: (1) Calibration is essential for the quantitative use of SeaWIFS and other SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) sensor data; (2) Calibration in the laboratory of spaceborne sensors is challenging; (3) Satellite sensors are subjected aging on the ground and to trauma during launch; (4) The Earth orbit environment is significantly different than the laboratory calibration environment; (5) Through years of effort AVIRIS has been demonstrated to be well calibrated; and (6) AVIRIS can match the spectral and spatial observation characteristics near the top of the atmosphere at the time of SeaWIFS measurements.

Green, Robert O.↗

Calibration of the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) plans to observe climate change trends over decadal time scales to determine the accuracy of climate projections. The project relies on spaceborne earth observations of SI-traceable variables sensitive to key decadal change parameters. The mission includes a reflected solar instrument retrieving at-sensor reflectance over the 320 to 2300 nm spectral range with 500-m spatial resolution and 100-km swath. Reflectance is obtained from the ratio of measurements of the earth s surface to those while viewing the sun relying on a calibration approach that retrieves reflectance with uncertainties less than 0.3%. The calibration is predicated on heritage hardware, reduction of sensor complexity, adherence to detector-based calibration standards, and an ability to simulate in the laboratory on-orbit sources in both size and brightness to provide the basis of a transfer to orbit of the laboratory calibration including a link to absolute solar irradiance measurements.

Thome, Kurtis↗

Measuring cosmological distances using cluster edges as a standard ruler

ABSTRACT The line-of-sight velocity dispersion profile of galaxy clusters exhibits a ‘kink’ corresponding to the spatial extent of orbiting galaxies. Because the spatial extent of a cluster is correlated with the amplitude of the velocity dispersion profile, we can utilize this feature as a gravity-calibrated standard ruler. Specifically, the amplitude of the velocity dispersion data allows us to infer the physical cluster size. Consequently, observations of the angular scale of the ‘kink’ in the profile can be translated into a distance measurement to the cluster. Assuming the relation between cluster radius and cluster velocity dispersion can be calibrated from simulations, we forecast that with existing data from the Sloan Digital Sky Survey we will be able to measure the Hubble constant with 3.0 per cent precision. Implementing our method with data from the Dark Energy Spectroscopic Instrument (DESI) will result in a 1.3 per cent measurement of the Hubble constant. Adding cosmological supernova data improves the uncertainty of the DESI measurement to 0.7 per cent. While these error estimates are statistical only, they provide strong motivation for pursuing the necessary simulation program required to characterize and calibrate the systematic uncertainties impacting our proposed measurement. Whether or not our proposed measurement can in fact result in competitive H0 constraints will depend on what the eventual systematics floor for this method is.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the SNPP and NOAA 20 VIIRS Sensors for Continuity of the MODIS Climate Data Records

Accurate long-term sensor calibration and periodic re-processing to ensure consistency and continuity of atmospheric, land and ocean geophysical retrievals from space within the mission period and across different missions is a major requirement of climate data records. In this work, we applied the Multi-Angle Implementation of Atmospheric Correction (MAIAC)-based vicarious calibration technique over Libya-4 desert site to perform calibration analysis of Visible Infrared Imaging Radiometer Suite (VIIRS) on Suomi National Polar-orbiting Partnership (SNPP) and NOAA-20 satellites. For both VIIRS sensors we characterized residual linear calibration trends and cross-calibrated both sensors to MODerate resolution Imaging Spectroradiometer (MODIS) Aqua regarded as a calibration standard. The relative spectral response (RSR) differences were accounted for using the German Aerospace Center (DLR) Earth Sensing Imaging Spectrometer (DESIS) hyperspectral surface reflectance data. Our results agree with independent vicarious calibration results of both the MODIS/VIIRS Characterization Support Team as well as the CERES Imager and Geostationary Calibration Group within estimated uncertainty of 1–2%. Analysis of MAIAC geophysical products with the new calibration shows a high level of agreement of MAIAC aerosol, surface reflectance and NDVI records between MODIS and VIIRS. Excluding high aerosol optical depth (AOD), all three sensors agree in AOD with mean difference (MD) less than 0.01 and residual mean squared difference rmsd ∼ 0.04. Spectral geometrically normalized surface reflectance agrees within rmsd of 0.003–0.005 in the visible and 0.01–0.012 at longer wavelengths. The residual surface reflectance differences are fully explained by differences in spectral filter functions. Finally, difference in NDVI is characterized by rmsd ∼ 0.02 and MD less than 0.003 for NDVI based on VIIRS imagery bands I1/I2 and less than 0.01 for NDVI based on VIIRS radiometric bands M5/M7. In practical sense, these numbers indicate consistency and continuity in MAIAC records ensuring the smooth transition from MODIS to VIIRS.

MAIAC↗

Binary pseudo-random array for calibration of interferometers with transmission spheres and cylinders

Binary pseudo-random array (BPRA) “white noise” artifacts are highly effective for characterizing the instrument transfer function (ITF) of surface topography metrology tools and wavefront measurement instruments. These BPRA artifacts feature all spatial frequencies within the instrument bandpass equally, resulting in a power spectral density with a white-noise-like character. This characteristic allows for direct ITF determination with uniform sensitivity across the entire spatial frequency range. We have developed a novel BPRA calibration standard that combines the diffractive pattern of a reflection computer-generated hologram (CGH) with the white noise generating BPRA pattern. By integrating these technologies using the same lithographic techniques, the resulting calibration sample enables ITF characterization of a Fizeau interferometer with a transmission sphere, or any nulling optic.

Munechika, K↗

Monitoring the Caustic Dissolution of Aluminum Alloy in a Radiochemical Hot Cell Using Raman Spectroscopy

Chemical processing of highly radioactive materials commonly takes place in heavily shielded hot cells. The remote, real-time monitoring of chemical processing streams via optical spectroscopic techniques in hot cells may be particularly useful. Here in this paper, we describe the implementation of Raman spectroscopy and chemometric analysis to monitor the dissolution of aluminum-clad targets containing irradiated aluminum–neptunium oxide cermet pellets in caustic solutions in a hot cell environment. Partial least squares regression analysis was used to generate calibration models to quantify the concentration of dissolved aluminum, nitrate, and hydroxide in solutions within the radiochemical hot cell. This work explored a systematic approach to optimize a matrix of calibration standards using a D-optimal experimental design. The Design of Experiments-based regression model, in comparison to more traditional analytical approaches, was found to be the more practical method for building calibration models, with fewer samples, to obtain informative analytical data from Raman spectra.

36 MATERIALS SCIENCE↗

Development and field testing of a rapid and ultra-stable atmospheric carbon dioxide spectrometer

We present field test results for a new spectroscopic instrument to measure atmospheric carbon dioxide (CO 2 ) with high precision (0.02 μmol mol -1 , or ppm at 1 Hz) and demonstrate high stability (within 0.1 ppm over more than 8 months), without the need for hourly, daily, or even monthly calibration against high-pressure gas cylinders. The technical novelty of this instrument (ABsolute Carbon dioxide, ABC) is the spectral null method using an internal quartz reference cell with known CO 2 column density. Compared to a previously described prototype, the field instrument has better stability and benefits from more precise thermal control of the optics and more accurate pressure measurements in the sample cell (at the mTorr level). The instrument has been deployed at a long-term ecological research site (the Harvard Forest, USA), where it has measured for 8 months without on-site calibration and with minimal maintenance, showing drift bounds of less than 0.1 ppm. Field measurements agree well with those of a commercially available cavity ring-down CO 2 instrument (Picarro G2301) run with a standard calibration protocol. This field test demonstrates that ABC is capable of performing high-accuracy, unattended, continuous field measurements with minimal use of reference gas cylinders.

Xiang, B.↗

Method and Apparatus for Testing Microwave Devices and Circuits in a Controlled Environment

A test system is disclosed that enables the testing of microwave components in a controlled environment without disturbing that environment. The system includes a test fixture which holds the calibration standards and the component being tested, and environmental control chamber, and a microwave switching system. The system provides a coaxial connection to microwave testing equipment, such as an automatic network analyzer (ANA) and facilitates both calibration and testing while maintaining environmental integrity.

Miranda, Felix A.↗

International comparison of radiometers - Techniques and results.

Description of an international comparison of radiometers made on May 10 through 14, 1971, with 24 instruments, each one representing the calibration standard of a different country or a major laboratory. All were pyranometers, viewing the sun and sky, thus bypassing the conventional method of transferring the standard from Angstrom pyrheliometers. This is the first time that pyranometers from all around the globe have been brought together in order to verify the scale on which to report solar radiation data. A highly accurate data collection system measured simultaneously the output of each instrument and that of a reference standard at 20-sec intervals. Over 300,000 radiometric signals were recorded under varying atmospheric conditions, as well as data on turbidity, temperature, and other relevant parameters. Computer programs were developed for overnight analysis of the data and distribution to participants on the following day. Among major findings are that instruments of different types and independent calibration such as those of Eppley, U. S. A., World Radiation Center, Switzerland, and Melbourne, Australia, show better agreement than anticipated, that certain national standards have to be revised by as much as 16% and that the cosine factor is highly dependent on the type of instrument.

Thekaekara, M. P.↗

System Measures Pressures Aboard A Compressor Rotor

Rotating pressure-measuring instrumentation includes on-board calibration standard. Computer-controlled, multichannel instrumentation system acquires pressure measurements from sensors mounted in 1.52-m-diameter rotor of compressor. Includes 5 miniature, electronically scanned pressure (ESP) modules, each containing 48 piezoresistive pressure sensors, pneumatic calibration valve, and electronic circuits for addressing and amplifying output of each sensor. Modules mounted on centerline of rotor, on instrumentation tower located inside nose cone of rotor. Subsystem designed to convert analog signal to distinct frequency without significantly affecting accuracy.

Freedman, Robert J.↗

Study for the analysis of the observations, and numerical data representing the planets as far-infrared calibration sources

The existing radiative transfer and inversion programs will be modified for application to the atmospheres of Uranus, Neptune, and Jupiter. The programs will be employed for analysis of KAO planetary observations in order to develop far infrared photometric calibration standards. This work will be carried out on MSFC computers. The expected end product of this task is a working program for analysis of the observations, and numerical data representing the planets as far-infrared calibration sources.

Wu, Shi Tsan↗

Algorithm for Lossless Compression of Calibrated Hyperspectral Imagery

A two-stage predictive method was developed for lossless compression of calibrated hyperspectral imagery. The first prediction stage uses a conventional linear predictor intended to exploit spatial and/or spectral dependencies in the data. The compressor tabulates counts of the past values of the difference between this initial prediction and the actual sample value. To form the ultimate predicted value, in the second stage, these counts are combined with an adaptively updated weight function intended to capture information about data regularities introduced by the calibration process. Finally, prediction residuals are losslessly encoded using adaptive arithmetic coding. Algorithms of this type are commonly tested on a readily available collection of images from the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) hyperspectral imager. On the standard calibrated AVIRIS hyperspectral images that are most widely used for compression benchmarking, the new compressor provides more than 0.5 bits/sample improvement over the previous best compression results. The algorithm has been implemented in Mathematica. The compression algorithm was demonstrated as beneficial on 12-bit calibrated AVIRIS images.

Kiely, Aaron B.↗

Importance of Calibration/Validation Traceability for Multi-Sensor Imaging Spectrometry Applications

Knowledge of calibration traceability is essential for ensuring the quality of data products relying on multiple sensors and especially true for imaging spectrometers. The current work discusses the expected impact that imaging spectrometers have in ensuring radiometric traceability for both multispectral and hyperspectral products. The Climate Absolute Radiance and Refractivity Observatory Pathfinder mission is used to show the role that high-accuracy imaging spectrometers can play in understanding test sites used for vicarious calibration of sensors. The associated Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer calibration demonstration system is used to illustrate recent advances in laboratory radiometric calibration approaches that will allow both the use of imaging spectrometers as calibration standards as well as to ensure the consistency of the multiple imaging spectrometers expected to be on orbit in the next decade.

imagin↗

Simple ultraviolet calibration source with reference spectra and its use with the Galileo orbiter ultraviolet spectrometer

A simple compact electron impact laboratory source of UV radiation has been developed and is used to obtain calibrated optically thin VUV spectra and synthetic spectral models for important molecular band systems of H2, N2, and the n 1P0 Rydberg series of He. The relative spectral intensity of the electron impact source can be used as the primary calibration standard for VUV instrumentation in the 80-230 nm range and with FWHM of not less than 0.4 nm. The accuracy of the present method is 10 percent in the FUV and 20 percent in the EUV. Results for calibration of the Galileo orbiter ultraviolet spectrometer have been compared with those obtained using other methods.

Shemansky, D. E.↗