Chemical ionization mass spectrometry utilizing benzene cations for measurements of volatile organic compounds and nitric oxide

We evaluate the capability of chemical ionization mass spectrometry (CIMS) using benzene cations as reagent ions (benzene CIMS) for detecting atmospheric trace gases. We characterize the ionization pathways and product ion distributions for 27 analytes spanning diverse chemical classes. To interpret the complex ion chemistry involving two reagent ions (C 6 H$^{+}_{6}$ and (C 6 H 6 )$^{+}_{2}$) and multiple ionization pathways (charge transfer, proton transfer, adduct formation, and hydride abstraction), we introduce a thermodynamics-based framework that classifies analytes into three categories based on their ionization energy (IE), relative to those of benzene monomer (9.24 eV) and dimer (8.69 eV). Each class exhibits distinct ionization mechanisms and product ions. Analytes with IE smaller than 8.69 eV (low IE) undergo charge transfer with both reagent ions; analytes with IE between 8.69 and 9.24 eV (mid IE) undergo charge transfer with C 6 H$^{+}_{6}$ and potential adduct formation with (C 6 H 6 )$^{+}_{2}$; analytes with IE larger than 9.24 eV (high IE) could undergo adduct formation, proton transfer, or hydride abstraction. Analytes within each class also show similar sensitivity, enabling sensitivity estimation for compounds lacking calibration standards. In addition to volatile organic compounds (VOCs), benzene CIMS detects nitric oxide (NO) with a detection limit of 5 pptv for 1 min integration time, exceeding the performance of most commercial NOx analyzers. Field deployments in Chicago and St. Louis demonstrate good agreement with reference NO measurements. Isoprene measurements show good agreement with a co-located gas chromatography–photoionization detector (GC-PID) in St. Louis, but exhibit substantial positive bias in Chicago, likely due to interferences from anthropogenic VOCs in the polluted urban environment. These results highlight the potential of benzene CIMS for concurrent measurements of NO, VOCs, and their oxidation products using a single instrument, while also underscoring challenges in complex atmospheric conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraining the sensitivity of iodide adduct chemical ionization mass spectrometry to multifunctional organic molecules using the collision limit and thermodynamic stability of iodide ion adducts

Abstract. The sensitivity of a chemical ionization mass spectrometer (ions formed per number density of analytes) is fundamentally limited by the collision frequency between reagent ions and analytes, known as the collision limit, the ion–molecule reaction time, and the transmission efficiency of product ions to the detector. We use the response of a time-of-flight chemical ionization mass spectrometer (ToF-CIMS) to N2O5, known to react with iodide at the collision limit, to constrain the combined effects of ion–molecule reaction time, which is strongly influenced by mixing and ion losses in the ion–molecule reaction drift tube. A mass spectrometric voltage scanning procedure elucidates the relative binding energies of the ion adducts, which influence the transmission efficiency of molecular ions through the electric fields within the vacuum chamber. Together, this information provides a critical constraint on the sensitivity of a ToF-CIMS towards a wide suite of routinely detected multifunctional organic molecules for which no calibration standards exist. We describe the scanning procedure and collision limit determination, and we show results from the application of these constraints to the measurement of organic aerosol composition at two different field locations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of Multiresidue Method for Analysis of 31 Pesticides in Rice Using Gas Chromatography-Tandem Mass Spectrometry

Five modified QuEChERS were tested for the multiresidue analysis of 31 pesticides in rice. Rice was spiked with mixture solution of pesticides at 10 ng/g. Method selection was based on the LODs (sensitivity) and recovery tests (accuracy) of the pesticides. Analysis was done in GC-tandem MS in multiple reaction monitoring mode with a total run time of approximately 37 min. The selected method was validated after spiking rice at 20 and 100 ng/g in rice. The performance characteristics of the method impacted for all selected pesticides were acceptable according to the guidelines for method validation (recovery of 70-120% with an RSD of <20% and r2value of ≥0.99). For rice, matrix effect on the signals of the compounds was corrected by using matrixmatched calibration standards. The LOQs met the requirements of the maximum residue limits for pesticides in rice. The developed method allowed for the simultaneous determination and confirmation of a large number of different groups of pesticides and was fast, simple, inexpensive, and useful for the routine analysis of rice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Multi-Energy Approach for Neutron Interrogation of Uranium Items

Bulk uranium items are often measured using active neutron interrogation systems to take advantage of the high penetrability of neutrons, providing the ability to quickly and accurately measure effective uranium masses in large, dense configurations. These active techniques employ an external neutron source to induce fission in the uranium and subsequently measure emitted prompt fission or delayed neutrons. Unfortunately, the emitted neutrons from 235U and 238U are, for all practical purposes, indistinguishable; therefore, common systems such as the Active Well Coincidence Counter and other systems based on measurement of prompt or delayed fission neutrons require many representative calibration standards or known isotopic information to interpret the results, thus limiting the application of these techniques for safeguards purposes. This paper presents the motivation for a multi-energy neutron interrogation technique which aims to improve the accuracy of these NDA techniques through the use of multiple neutron interrogation sources. Potentially, the dual measurement approach will allow the mass values of the isotopes in the item to be independently determined while minimizing the number of representative standards needed and/or eliminating the need for prior knowledge of the isotopic information. This work examines the change in fission rates with differing interrogating neutron energy and, therefore, the potential of this new technique to independently measure the masses of 235U and 238U in the measurement item. Initial simulation and measurement results will be presented.

Hayward, Jason P.↗

High count rate thermal neutron detectors and electronics

Improved, high count rate thermal neutron counters and electronics enabling new, higher measurement capabilities are disclosed. Next generation 3He and 10B tubes may include an electronics package capable of operating at higher count rates and in higher gamma fields and providing more efficient use of 3He gas. Conventional detector systems may also be upgraded, providing a possible solution to measure spent nuclear fuel with high neutron efficiency previously not possible in 235U fission counter systems. Switching the number of tubes per amplifier allows use of the measured nuclear material for a calibration standard for dead time correction, increasing accuracy of neutron measurements systems. An optimized detector geometry and advanced electronics with double pulse filtering and a dual channel readout may be provided. A bipolar shaper may improve dead time, provide efficient detector use, reduce double pulsing, facilitate high count rate measurements, and allow remote threshold setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Operation of a Multi-Bed Catalytic Micro-Reactor for the Study of Co-Processing of Bio-Oils with VGO

An industry wide shift from fossil-based fuel to renewable fuel sources including biomass, municipal waste, and plastics will require new process monitoring methods to minimize transitional risks including off specification product formation and catalyst deactivation. This project aims to provide a machine learning based process monitoring tool composed of online, slipstream mass spectra for use in biomass refineries and co-processing in existing refineries allowing operators to monitor product qualities and adjust process conditions accordingly. In order to maximize the robustness of the tool, large volumes of data must be collected to fine tune model parameters which consists of both micro and pilot scale mass spectral data. Micro-scale data is collected with a multi-tube micro-reactor housing up to six catalysts in horizontal beds, coupled with a molecular beam mass spectrometer. A pyrolizer equipped with an auto-sampler streamlines the micro-scale data collection process. This type of pyrolizer/micro-reactor configuration does not exist on the market, and therefore had to be created for the purposes of this project. The design and commissioning of this reactor will be presented in detail. This reactor set-up is highly flexible and increases throughput of analysis. For catalyst testing, each bed can be individually selected simply by turning valves. For catalyst reduction and regeneration, simultaneous flow through all six beds is used. The reproducibility of the system was first assessed with whole biomass pyrolysis along with pyrolysis of calibration standards. Initial work on this system evaluated two FCC catalysts, equilibrium catalyst (E-cat), and a proprietary catalyst from Johnson Matthey specifically design for co-processing of bio-oil with vacuum gas oil (VGO). This work used model compounds and VGO which illuminated differences in products produced by the catalysts.

biomass↗

Tissue-like phantoms

The invention is based, in part, on the discovery that by combining certain components one can generate a tissue-like phantom that mimics any desired tissue, is simple and inexpensive to prepare, and is stable over many weeks or months. In addition, new multi-modal imaging objects (e.g., beads) can be inserted into the phantoms to mimic tissue pathologies, such as cancer, or merely to serve as calibration standards. These objects can be imaged using one, two, or more (e.g., four) different imaging modalities (e.g., x-ray computed tomography (CT), positron emission tomography (PET), single photon emission computed tomography (SPECT), and near-infrared (NIR) fluorescence) simultaneously.

60 APPLIED LIFE SCIENCES↗

Uncertainty Analysis of Spectral Irradiance Reference Standards Used for NREL Calibrations

Spectral irradiance produced by lamp standards such as the National Institute of Standards and Technology (NIST) FEL-type tungsten halogen lamps are used to calibrate spectroradiometers at the National Renewable Energy Laboratory. Spectroradiometers are often used to characterize spectral irradiance of solar simulators, which in turn are used to characterize photovoltaic device performance, e.g., power output and spectral response. Therefore, quantifying the calibration uncertainty of spectroradiometers is critical to understanding photovoltaic system performance. In this study, we attempted to reproduce the NIST-reported input variables, including the calibration uncertainty in spectral irradiance for a standard NIST lamp, and quantify uncertainty for measurement setup at the Optical Metrology Laboratory at the National Renewable Energy Laboratory.

14 SOLAR ENERGY↗

ABSOLUTE FLUX CALIBRATION OF THE IRAC INSTRUMENT ON THE SPITZER SPACE TELESCOPE USING HUBBLE SPACE TELESCOPE FLUX STANDARDS

The absolute flux calibration of the James Webb Space Telescope (JWST) will be based on a set of stars observed by the Hubble and Spitzer Space Telescopes. In order to cross-calibrate the two facilities, several A, G, and white dwarf stars are observed with both Spitzer and Hubble and are the prototypes for a set of JWST calibration standards. The flux calibration constants for the four Spitzer IRAC bands 1-4 are derived from these stars and are 2.3%, 1.9%, 2.0%, and 0.5% lower than the official cold-mission IRAC calibration of Reach et al., i.e., in agreement within their estimated errors of {approx}2%. The causes of these differences lie primarily in the IRAC data reduction and secondarily in the spectral energy distributions of our standard stars. The independent IRAC 8 {mu}m band-4 fluxes of Rieke et al. are about 1.5% {+-} 2% higher than those of Reach et al. and are also in agreement with our 8 {mu}m result.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-CD-207B-11: Multi-Vendor Phantom Study of CT Lung Density Metrics: Is a Reproducibility of Less Than 1 HU Achievable?

Purpose: To standardize the calibration procedures of CT lung density measurements using low-density reference foams in a phantom, and to demonstrate a reproducibility of less than 1 HU for lung equivalent foam densities measured across CT vendor platforms and protocols. Methods: A phantom study was conducted on CT scanner models from 4 vendors at 100, 120, and 135/140 kVp and 1.5, 3, and 6 mGy dose settings, using a lung density phantom containing air, water, and 3 reference foams (indirectly calibrated) with discrete densities simulating a 5-cm slice of the human chest. Customized segmentation software was used to analyze the images and generate a mean HU and variance for each of the density for the 22 vendor/protocols. A 3-step calibration process was devised to remove a scanner-dependent parameter using linear regression of the HU value vs the relative electron density. The results were mapped to a single energy (80 keV) for final comparison. Results: The heterogeneity across vendor platforms for each density assessed by a random effects model was reduced by 50% after re-calibration, while the standard deviation of the mean HU values also improved by about the same amount. The 95% CI of the final HU value was within +/−1 HU for all 3 reference foam densities. For the backing lung foam in the phantom (served as an “unknown”), this CI is +/− 1.6 HU. The kVp and dose settings did not appear to have significant contributions to the variability. Conclusion: With the proposed calibration procedures, the inter-scanner reproducibility of better than 1 HU is demonstrated in the current phantom study for the reference foam densities, but not yet achieved for a test density. The sources of error are being investigated in the next round of scanning with a certified Standard Reference Material for direct calibration. Fain: research funding from GE Healthcare to develop pulmonary MRI techniques. Hoppel: employee of Toshiba Medical Research Institute USA/financial interest with GE Healthcare. M. Fuld: employee of Siemens Healthcare for medical device equipment and software. This project is supported partially by RSNA QIBA Concept Award (Fain), NIH/NIBIB, HHSN268201300071C (Y).

60 APPLIED LIFE SCIENCES↗

Spatial calibration of a tokamak neutral beam diagnostic using in situ neutral beam emission

Neutral beam injection is used in tokamaks to heat, apply torque, drive non-inductive current, and diagnose plasmas. Neutral beam diagnostics need accurate spatial calibrations to benefit from the measurement localization provided by the neutral beam. A new technique has been developed that uses in situ measurements of neutral beam emission to determine the spatial location of the beam and the associated diagnostic views. This technique was developed to improve the charge exchange recombination (CER) diagnostic at the DIII-D tokamak and uses measurements of the Doppler shift and Stark splitting of neutral beam emission made by that diagnostic. These measurements contain information about the geometric relation between the diagnostic views and the neutral beams when they are injecting power. This information is combined with standard spatial calibration measurements to create an integrated spatial calibration that provides a more complete description of the neutral beam-CER system. The integrated spatial calibration results are very similar to the standard calibration results and derived quantities from CER measurements are unchanged within their measurement errors. The methods developed to perform the integrated spatial calibration could be useful for tokamaks with limited physical access.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-D-BRD-04: NIST Air-Kerma Standard for Electronic Brachytherapy Calibrations

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

Impact of lump characteristics on self-shielding corrections of active neutron interrogation on fissile material in waste - 15405

Non-destructive active neutron assay techniques such as active neutron coincidence counting, differential die away analysis or the californium shuffler method rely on the interrogation of fissile nuclear materials by an external neutron source. Whether it is a spontaneous fission or (α,n) neutron source, like {sup 252}Cf or AmLi; or a fusion neutron generator, all of these techniques rely on induced secondary fission events to provide prompt or delayed neutron signals that serve as the basis for the fissile material quantification. The accuracy of these fissile mass measurements is therefore dependent on the neutron interrogation efficiencies determined for calibration reference standards and whether the measured items are comparable to the calibration condition. In such favorable conditions, it is possible to establish a reliable empirical non-linear relationship between apparent (uncorrected) and real or true fissile mass. However, in waste measurements, this is unlikely to be the case; thus a calibration approach that takes account of the neutron self-shielding effect is required. By incorporating the Self-Shielding Factor (SSF) of the calibration reference standards, a linear mass calibration factor [s{sup -1}. {sup 239}Pu{sub eq} g{sup -1}] can be found; this calibration is accurate for waste in which the fissile material is 'infinitely dilute' i.e. the waste exhibits no self-shielding; this is assumed to be representative of dispersed material. The self-shielding correction and its systematic uncertainty are then left to be treated as part of the Total Measurement Uncertainty (TMU) evaluation associated with the assay result. The derivation of the TMU contribution associated with the self-shielding effect in nuclear waste is a complex problem for which a reliable evaluation has to be performed. This is usually based on assuming 'worst case scenarios' for the distribution of material that can arise in a particular waste stream. Such an approach is conservative, but often very penalizing, especially if one considers larger lumps (those containing grams of fissile material); for such lumps, the self-shielding correction becomes very significant, potentially altering the mass of {sup 239}Pu{sub eq} by over an order of magnitude. A worst case 'nuclear safety value' may not be the most appropriate choice for building a consignment best estimate or repository sentencing value for an item. In the present work the authors describe a numerical approach to study the variability of neutron self-shielding factors associated with distributions of a wide range of lump characteristics in terms of size, shape, chemical composition, density and isotopic composition. The described novel calculation tool is capable of accurately predicting the real impact of random distribution of lumps in a waste material, and allowed to show that given reasonable, defensible, assumptions on the composition of the lumps in waste stream, the systematic error component of the DDA TMU can be significantly reduced. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Activity Waste Glass Standards Preparation and Characterization for Calibration of Analytical Instruments

A matrix of seven low-activity waste (LAW) glasses was fabricated and characterized to be used by the Hanford Waste Treatment and Immobilization Plant (WTP) as analytical instrument calibration and matrix interference standards when measuring LAW glass compositions. The matrix of glasses was designed to represent the range of LAW glass compositions that will be generated by the WTP. Samples from each of the seven glasses were measured with electron probe microanalysis (EPMA), ion chromatography (IC), and bulk inductively coupled plasma mass spectroscopy (ICP-MS) to determine the variability and accuracy across batches and within individually poured glass bar samples. High relative percent differences and standard deviations were calculated for components with low concentrations due to instrument detection limits. IC and ICP-MS percent differences and standard deviations were higher at low component concentrations. Otherwise, variability in measured compositions from IC and ICP-MS was generally lower than measurements from EPMA, with the exclusion of Cl, F, Si, and B. Overall, the two methods proved comparable and complementary. From EPMA, IC, and ICP-MS data, volatile elements were underrepresented compared to batched compositions, which suggested loss of these elements during melting. EPMA data was statistically analyzed to evaluate homogeneity within single bars and whole compositions for each of the seven glasses. Most of the variability within glass compositions occurred at the bar-to-bar level; however, no clear systematic trends were observed. Based on these analyses, when using these glasses as reference material, it is recommended that the overall mean and variance of each composition be used for performing instrument calibrations and analytical corrections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗