Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALORIMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design and Testing of the Endcap Concentrator ASICs for the CMS High-Granularity Calorimeter Upgrade

A major upgrade of the High-Granularity Calorimeter (HGCAL) in the CMS detector is planned for Long-Shutdown 3 (LS3), currently expected to start in 2026. This upgrade will contain over 6 million channels and the electronics will be required to be low power and to withstand a radiation environment with a High-Energy Hadron flux of 3x10**6 particles per square centimeter per second. The solution to this significant challenge is the two Endcap Concentrator (ECON) ASICs, ECON-T and ECON-D, working in tandem with the HGCROC front-end ASIC. The two ECON ASICs provide critical on-detector data reduction for both the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs are fabricated in 65nm CMOS. They are rad-tolerant to 600 Mrad with low power consumption (<2.5 mW/channel). This presentation will be a comprehensive description of each ECON design, including the infrastructure that they share as well as the elements that make each unique. The presentation will also include functionality and radiation tests for both ASICs, and the first high statistics characterization results from the full production of 75k ECON-D and ECON-T ASICs.

Hoff, James R. [Fermilab] (ORCID:0000000163514592)↗

Large-area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-β decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work, we showcase light detectors based on an alternative Ir-Pt bilayer transition-edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of < 100 eV rms. Our detectors have risetimes of approximately 180μs and measured timing jitter of < 20μs for the expected signal to noise at the Q value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-β decay pile-up events. In conclusion, the current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of ultralow-background cryogenic calorimeters for the measurement of surface α contamination

Next-generation experiments searching for rare events must satisfy increasingly stringent requirements on the bulk and surface radioactive contamination of their active and structural materials. The measurement of surface contamination is particularly challenging, as no existing technology is capable of separately measuring parts of the 232 Th and 238 U decay chains that are commonly found to be out of secular equilibrium. We will present the results obtained with a detector prototype consisting of 8 silicon wafers of 150mm diameter instrumented as bolometers and operated in a low-background dilution refrigerator at the Gran Sasso Underground Laboratory of INFN, Italy. Furthermore, the prototype was characterized by a baseline energy resolution of few keV and a background <100nBq/cm 2 in the full range of α energies, obtained with simple procedures for cleaning of all employed materials and no specific measures to prevent recontamination. Such performance, together with the modularity of the detector design, demonstrate the possibility to realize an alpha detector capable of separately measuring all alpha emitters of the 232 Th and 238 U chains, possibly reaching a sensitivity of few nBq/cm 2 .

07 ISOTOPE AND RADIATION SOURCES↗

Background identification in cryogenic calorimeters through $\alpha -\alpha$ delayed coincidences

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $\alpha -\alpha$ delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $\alpha$ decay position.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving the performance of cryogenic calorimeters with nonlinear multivariate noise cancellation algorithms

Abstract State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical interference or microphonics. The sources of this environmental noise can often be monitored by adding specially designed “auxiliary devices” (e.g. microphones, accelerometers, seismometers, magnetometers, and antennae). A model can then be constructed to predict the detector noise based on the auxiliary device information, which can then be subtracted from the true detector signal. Here, we present a multivariate noise cancellation algorithm which can be used in a variety of settings to improve the performance of detectors using multiple auxiliary devices. To validate this approach, we apply it to simulated data to remove noise due to electromagnetic interference and microphonic vibrations. We then employ the algorithm to a cryogenic light detector in the laboratory and show an improvement in the detector performance. Finally, we motivate the use of nonlinear terms to better model vibrational contributions to the noise in thermal detectors. We show a further improvement in the performance of a particular channel of the CUORE detector when using the nonlinear algorithm in combination with optimal filtering techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Publisher Erratum: A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

In the originally published version of this article, several errors were identified in the author list and acknowledgements section. These have now been corrected as follows: Corrections to the Author List: Barrera has been corrected to Barresi. Copello (affiliation 18) has been corrected to Copello (affiliation 19). F. De Domizio has been corrected to S. Di Domizio. Figueros-Feliciamo has been corrected to Figueroa-Feliciano. Mancarella (affiliations 8, 17) has been corrected to Mancarella (affiliations 8, 18). Manenti (affiliations 18, 19) has been corrected to Manenti (affiliations 19, 20). Mayer (affiliations 3, 20, 31) has been corrected to Mayer (affiliations 3, 21, 31). Pagot has been corrected to Pageot. Puranam (affiliation 20) has been corrected to Puranam (affiliation 21). O. Penek has been corrected to Ö. Penek. L. Pettinacci has been corrected to V. Pettinacci. P. Pirro has been corrected to S. Pirro. Previtale has been corrected to Previtali. Rappoldi (affiliation 18) has been corrected to Rappoldi (affiliation 19). Raselli (affiliation 18) has been corrected to Raselli (affiliation 19). Rizzoli (affiliations 8, 17) has been corrected to Rizzoli (affiliations 8, 18). Rossella (affiliation 18) has been corrected to Rossella (affiliation 19). Correction to the Acknowledgements Section: The following grant numbers were missing and have now been added: This work was supported by NSF-PHY-2412377 and NSF-PHY-1913374. Additionally, on page 11, Section 5, second line, the chemical formula was incorrectly given as Li 2 MO 4 . The correct formula is Li 2 MoO 4 . The original article has been updated to reflect these corrections. The publisher apologizes for the inconvenience.

Alfonso, K. [Virginia Polytechnic Institute and St↗

Search for New Bosons in Gluon-Gluon and Vector Boson Fusion Processes at the LHC and Development of Silicon Module Assembly Techniques for the CMS High Granularity Calorimeter

A search for heavy resonances decaying to a pair of vectors bosons is presented which utilizes events in which a hadronically decaying Z or W boson is identified using jet substructure techniques and large missing transverse momentum is found. Data analyzed were recorded by the Compact Muon Solenoid experiment at the CERN Large Hadron Collider in 2016, 2017, and 2018, and correspond to 137 fb$^{-1}$ . The events are categorized as having arisen from Vector Boson Fusion process or not, and are characterized by their transverse mass distribution. The standard model backgrounds are estimated based on observed yields in control regions. No excess of events above the expected SM background are observed and limits are placed on the production cross section of Radion (spin-0), Wprime (spin-1) and Bulk graviton (spin2) particles. In adiditon, the high luminosity LHC and the CMS HGCAL upgrade are also presented. The assembly techniques and various tests for the Silicon module and the cassette are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗