Search NASA⌕ Search

SEARCH · Search NASA

Results for “CAVITY RESONATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Benchmarking the performance of a high-Q cavity qudit using random unitaries

High-coherence cavity resonators are excellent resources for encoding quantum information in higher-dimensional Hilbert spaces, moving beyond traditional qubit-based platforms. A natural strategy is to use the Fock basis to encode information in qudits. One can perform quantum operations on the cavity mode qudit by coupling the system to a non-linear ancillary transmon qubit. However, the performance of the cavity-transmon device is limited by the noisy transmons. It is, therefore, important to develop practical benchmarking tools for these qudit systems in an algorithm-agnostic manner. We gauge the performance of these qudit platforms using sampling tests such as the heavy output generation test as well as the linear cross-entropy benchmark, by way of simulations of such a system subject to realistic dominant noise channels. We use selective number-dependent arbitrary phase and unconditional displacement gates as our universal gateset. Our results show that contemporary transmons comfortably enable controlling a few tens of Fock levels of a cavity mode. This framework allows benchmarking even higher dimensional qudits as those become accessible with improved transmons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cavity perturbation techniques for measurement of the microwave conductivity and dielectric constant of a bulk semiconductor material.

Cavity perturbation techniques offer a very sensitive and highly versatile means for studying the complex microwave conductivity of a bulk material. A knowledge of the cavity coupling factor in the absence of perturbation, together with the change in the reflected power and the cavity resonance frequency shift, are adequate for the determination of the material properties. This eliminates the need to determine the Q-factor change with perturbation which may lead to appreciable error, especially in the presence of mismatch loss. The measurement accuracy can also be improved by a proper choice of the cavity coupling factor prior to the perturbation.

Eldumiati, I. I.↗

Selected computations of transonic cavity flows

An efficient diagonal scheme implemented in an overset mesh framework has permitted the analysis of geometrically complex cavity flows via the Reynolds averaged Navier-Stokes equations. Use of rapid hyperbolic and algebraic grid methods has allowed simple specification of critical turbulent regions with an algebraic turbulence model. Comparisons between numerical and experimental results are made in two dimensions for the following problems: a backward-facing step; a resonating cavity; and two quieted cavity configurations. In three-dimensions the flow about three early concepts of the stratospheric Observatory For Infrared Astronomy (SOFIA) are compared to wind-tunnel data. Shedding frequencies of resolved shear layer structures are compared against experiment for the quieted cavities. The results demonstrate the progress of computational assessment of configuration safety and performance.

Atwood, Christopher A.↗

Curved grating fabrication techniques for concentric-circle grating, surface-emitting semiconductor lasers

We describe the fabrication and operational characteristics of a novel, surface-emitting semiconductor laser that makes use of a concentric-circle grating to both define its resonant cavity and to provide surface emission. A properly fabricated circular grating causes the laser to operate in radially inward- and outward-going circular waves in the waveguide, thus, introducing the circular symmetry needed for the laser to emit a beam with a circular cross-section. The basic circular-grating-resonator concept can be implemented in any materials system; an AlGaAs/GaAs graded-index, separate confinement heterostructure (GRINSCH), single-quantum-well (SQW) semiconductor laser, grown by molecular beam epitaxy (MBE), was used for the experiments discussed here. Each concentric-circle grating was fabricated on the surface of the AlGaAs/GaAs semiconductor laser. The circular pattern was first defined by electron-beam (e-beam) lithography in a layer of polymethylmethacrylate (PMMA) and subsequently etched into the semiconductor surface using chemically-assisted (chlorine) ion-beam etching (CAIBE). We consider issues that affect the fabrication and quality of the gratings. These issues include grating design requirements, data representation of the grating pattern, and e-beam scan method. We provide examples of how these techniques can be implemented and their impact on the resulting laser performance. A comparison is made of the results obtained using two fundamentally different electron-beam writing systems. Circular gratings with period lambda = 0.25 microns and overall diameters ranging from 80 microns to 500 microns were fabricated. We also report our successful demonstration of an optically pumped, concentric-circle grating, semiconductor laser that emits a beam with a far-field divergence angle that is less than one degree. The emission spectrum is quite narrow (less than 0.1 nm) and is centered at wavelength lambda = 0.8175 microns.

Jordan, Rebecca H.↗

Hydrogen masers with cavity frequency switching servos

The stability of the free-running hydrogen maser is limited by pulling of the unperturbed hydrogen transition frequency due to instability of the cavity resonance frequency. While automatic spin-exchange tuning is in principle the more basic and accurate method, the required beam intensity switching and the long servo time constant result in reduced stability for measuring intervals up to 10(exp 6) seconds. More importantly, the spin-exchange tuning method requires a second stable frequency source as a reference, ideally a second hydrogen maser, to get the best results. The cavity frequency switching servo, on the other hand, has very little effect on the maser short term stability, and is fast enough to correct for cavity drift while maintaining the cavity at the spin-exchange tuned offset required to minimize instability due to beam intensity fluctuations. Not only does the cavity frequency switching servo not require a second stable frequency source, but the frequency reference is the atomic hydrogen radiated beam signal, so that no extra RF connections need be made to the cavity, and externally generated signals that would perturb the hydrogen atom need not be transmitted through the cavity. The operation of the cavity frequency switching stabilization method is discussed and the transient response of the servo and certain other aspects of the technique that have potential for achieving improved basic accuracy are illustrated.

Peters, Harry E.↗

Laser Resonator

An optical resonator cavity configuration has a unitary mirror with oppositely directed convex and concave reflective surfaces disposed into one fold and concertedly reversing both ends of a beam propagating from a laser rod disposed between two total internal reflection prisms. The optical components are rigidly positioned with perpendicularly crossed virtual rooflines by a compact optical bed. The rooflines of the internal reflection prisms, are arranged perpendicularly to the axis of the laser beam and to the optical axes of the optical resonator components.

Harper, L. L.↗

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]↗

Low frequency electric and magnetic fields

Following preliminary investigations of the low frequency electric and magnetic fields that may exists in the Earth-ionospheric cavity, measurements were taken with state-of-the art spectrum analyzers. As a follow up to this activity, an investigation was initiated to determine sources and values for possible low frequency signal that would appear in the cavity. The lowest cavity resonance is estimated at about 8 Hz, but lower frequencies may be an important component of our electromagnetic environment. The potential field frequencies produced by the electron were investigated by a classical model that included possible cross coupling of the electric and gravitation fields. During this work, an interesting relationship was found that related the high frequency charge field with the extremely low frequency of the gravitation field. The results of numerical calculations were surprisingly accurate and this area of investigation is continuing. The work toward continued development of a standardized monitoring facility is continuing with the potential of installing the prototype at West Virginia State College early in 1990. This installation would be capable of real time monitoring of ELF signals in the Earth-ionoshpere cavity and would provide some directional information. A high gain, low noise, 1/f frequency corrected preamplifier was designed and tested for the ferrite core magnetic sensor. The potential application of a super conducting sensor for the ELF magnetic field detection is under investigation. It is hoped that a fully operational monitoring network could pinpoint the location of ELF signal sources and provide new information on where these signals originate and what causes them, assuming that they are natural in origin.

Spaniol, Craig↗

Microwave Resonator Measurements of Atmospheric Absorption Coefficients: A Preliminary Design Study

A preliminary design study examined the feasibility of using microwave resonator measurements to improve the accuracy of atmospheric absorption coefficients and refractivity between 18 and 35 GHz. Increased accuracies would improve the capability of water vapor radiometers to correct for radio signal delays caused by Earth's atmosphere. Calibration of delays incurred by radio signals traversing the atmosphere has applications to both deep space tracking and planetary radio science experiments. Currently, the Cassini gravity wave search requires 0.8-1.0% absorption coefficient accuracy. This study examined current atmospheric absorption models and estimated that current model accuracy ranges from 5% to 7%. The refractivity of water vapor is known to 1% accuracy, while the refractivity of many dry gases (oxygen, nitrogen, etc.) are known to better than 0.1%. Improvements to the current generation of models will require that both the functional form and absolute absorption of the water vapor spectrum be calibrated and validated. Several laboratory techniques for measuring atmospheric absorption and refractivity were investigated, including absorption cells, single and multimode rectangular cavity resonators, and Fabry-Perot resonators. Semi-confocal Fabry-Perot resonators were shown to provide the most cost-effective and accurate method of measuring atmospheric gas refractivity. The need for accurate environmental measurement and control was also addressed. A preliminary design for the environmental control and measurement system was developed to aid in identifying significant design issues. The analysis indicated that overall measurement accuracy will be limited by measurement errors and imprecise control of the gas sample's thermodynamic state, thermal expansion and vibration- induced deformation of the resonator structure, and electronic measurement error. The central problem is to identify systematic errors because random errors can be reduced by averaging. Calibrating the resonator measurements by checking the refractivity of dry gases which are known to better than 0.1% provides a method of controlling the systematic errors to 0.1%. The primary source of error in absorptivity and refractivity measurements is thus the ability to measure the concentration of water vapor in the resonator path. Over the whole thermodynamic range of interest the accuracy of water vapor measurement is 1.5%. However, over the range responsible for most of the radio delay (i.e. conditions in the bottom two kilometers of the atmosphere) the accuracy of water vapor measurements ranges from 0.5% to 1.0%. Therefore the precision of the resonator measurements could be held to 0.3% and the overall absolute accuracy of resonator-based absorption and refractivity measurements will range from 0.6% to 1.

Walter, Steven J.↗

Measurement of the Isolated Nuclear Two-Photon Decay in Ge 72

The nuclear two-photon or double-gamma (2 γ ) decay is a second-order electromagnetic process whereby a nucleus in an excited state emits two gamma rays simultaneously. To be able to directly measure the 2⁢ γ decay rate in the low-energy regime below the electron-positron pair-creation threshold, we combined the isochronous mode of a storage ring with Schottky resonant cavities. The newly developed technique can be applied to isomers with excitation energies down to ~100 keV and half-lives as short as ~10 ms. The half-life for the 2⁢ γ decay of the first-excited 0 + state in bare 72 Ge ions was determined to be 23.9(6) ms, which strongly deviates from expectations.

59 ≤ A ≤ 89↗

EPR Imaging at a Few Megahertz Using SQUID Detectors

An apparatus being developed for electron paramagnetic resonance (EPR) imaging operates in the resonance-frequency range of about 1 to 2 MHz well below the microwave frequencies used in conventional EPR. Until now, in order to obtain sufficient signal-to-noise radios (SNRs) in conventional EPR, it has been necessary to place both detectors and objects to be imaged inside resonant microwave cavities. EPR imaging has much in common with magnetic resonance imaging (MRI), which is described briefly in the immediately preceding article. In EPR imaging as in MRI, one applies a magnetic pulse to make magnetic moments (in this case, of electrons) precess in an applied magnetic field having a known gradient. The magnetic moments precess at a resonance frequency proportional to the strength of the local magnetic field. One detects the decaying resonance-frequency magnetic- field component associated with the precession. Position is encoded by use of the known relationship between the resonance frequency and the position dependence of the magnetic field. EPR imaging has recently been recognized as an important tool for non-invasive, in vivo imaging of free radicals and reduction/oxidization metabolism. However, for in vivo EPR imaging of humans and large animals, the conventional approach is not suitable because (1) it is difficult to design and construct resonant cavities large enough and having the required shapes; (2) motion, including respiration and heartbeat, can alter the resonance frequency; and (3) most microwave energy is absorbed in the first few centimeters of tissue depth, thereby potentially endangering the subject and making it impossible to obtain adequate signal strength for imaging at greater depth. To obtain greater penetration depth, prevent injury to the subject, and avoid the difficulties associated with resonant cavities, it is necessary to use lower resonance frequencies. An additional advantage of using lower resonance frequencies is that one can use weaker applied magnetic fields: For example, for a resonance frequency of 1.4 MHz, one needs a magnetic flux density of 0.5 Gauss approximately the flux density of the natural magnetic field of the Earth.

Hahn, Inseob↗

Ultrabroadband Spacetime Nanoscopy of Terahertz Polaritons in a van der Waals Cavity

Guiding, storing, and processing light at the nanoscale hinges on understanding how polaritons — hybrid quasiparticles of light and matter — propagate and interfere in both space and time. This work introduces a synchrotron-based technique, SYnchrotron SpaceTimE Mapping (SYSTEM), which captures real-time evolution of polariton wave packets with ∼10 nm spatial and sub-100 fs temporal resolution across an ultrabroadband 5–50 THz range. Here, SYSTEM directly visualizes the creation, interference, and decay of multiple high-quality Fabry-Pérot phonon polariton cavity modes in an α-MoO 3 microcavity. These real-space, real-time observations reveal wave-packet dynamics and cavity resonances with record-high quality factors (Q ≈ 100) in the single-digit terahertz regime near 9 THz. SYSTEM thus offers a powerful and broadly applicable platform for probing and engineering ultraslow, deeply subwavelength polaritons, opening new avenues for tailoring light–matter interactions and advancing next-generation THz nanophotonic technologies.

36 MATERIALS SCIENCE↗

Enhanced boron doping for diamond growth in cylindrical CVD reactors using a Faraday cage

We report on the use of 3D-printed titanium Faraday cages in a cylindrical resonant cavity CVD reactor for the growth of heavily boron-doped single-crystalline superconducting diamond. We show that the cage enhances boron doping uniformity and provides control of the doping efficiency and growth rate by varying the distance between the plasma and the diamond surface. Using finite element modelling, we demonstrate that the Faraday cage focuses the electric field at the top of the cage whilst also suppressing the electric field inside the cage, thereby pinning the plasma at a fixed height above the sample. This eliminates plasma “hot spots” at the edges of the sample and creates a more uniform plasma electron and hydrogen radical distribution over the sample, resulting in a more uniform boron incorporation.

Boron doped diamond↗

Conditional guided generative diffusion for particle accelerator beam diagnostics

Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.

43 PARTICLE ACCELERATORS↗

The 140 GHz notch filter development for millimeter-wave diagnostics protection on the stellarator Wendelstein 7-X

The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). Furthermore, the utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Stability of the Dot-in-Well Gain Medium for Photonic Crystal Surface Emitting Lasers

Self-assembled quantum dots (QDs) embedded in InGaAs quantum wells (QWs) are used as active regions for photonic-crystal surface-emitting lasers (PCSELs). An epitaxial regrowth method is developed to fabricate the dot-in-well (DWELL) PCSELs. Here, the epitaxial regrowth starts with the growth of a partial laser structure containing bottom cladding, waveguide, active region, and the photonic crystal (PC) layer. The PC layer is patterned to realize the cavity. Subsequently a top cladding layer is regrown to complete the laser structure. During the regrowth of the top cladding layer, the partial laser structure is subjected to high growth temperatures in excess of 600 °C resulting in an unintentional annealing of the active region. This annealing of the active region can alter the QDs by changing their size resulting in a blue shift in photoluminescence (PL) and narrowing PL emission. This effect results in the misaligning of the gain peak and the cavity resonance, resulting in sub-optimal lasing performance. DWELL active regions are known to have better thermal stability compared to both QDs and QWs and could be an ideal candidate for regrown PCSELs. We successfully demonstrate an optically-pumped epitaxially-regrown DWELL PCSEL with an emission wavelength of 1230 nm operating at room temperature. Furthermore, the DWELL active region shows excellent emission wavelength stability and intensity despite the high temperature regrowth process.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Large Bore Conduction Cooled Superconducting Magnet for the Princeton Axion Search

Princeton University (PU) is designing and building a new experiment, called the Princeton Axion Search (PXS), that aims to discover (or exclude) Quantum Chromodynamics (QCD) axions in the 0.8–2 μeV mass range that are the cosmological dark matter. Core elements of the experiment are new, and in particular new to the search for axion dark matter. An essential component of the experiment is a 5 T superconducting magnet with a total bore volume of ~500 L. The Princeton Plasma Physics Laboratory (PPPL), a Department of Energy (DOE) Laboratory managed by Princeton University, has the unique expertise and experimental facilities to design and construct such a solenoid magnet assembled with the cavity resonator for PXS. To support this, PPPL utilizes legacy ITER-Nb3Sn conductors, along with its experimental facilities and expertises to design, build and test low-cost conduction-cooled superconducting solenoid magnets to be integrated into the axion detector. This paper discusses the various coil design and integration challenges in the large bore conduction cooled magnet in support of PXS. In conclusion, the proposed instrumental methods will help optimize the path to future and more ambitious axion searches at lower masses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗