Search NASA⌕ Search

SEARCH · Search NASA

Results for “CEBAF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Commissioning and Operation of 12 GeV CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) located at the Thomas Jefferson National Accelerator Laboratory (JLab) has been recently upgraded to deliver continuous electron beams to the experimental users at a maximum energy of 12 GeV, three times the original design energy of 4 GeV. This paper will present an overview of the upgrade, referred to as the 12GeV upgrade, and highlights from recent beam commissioning results.

43 PARTICLE ACCELERATORS↗

eDT and Model-based Configuration of 12GeV CEBAF

This poster will discuss model-driven setup of CEBAF for the 12GeV era, focusing on the elegant Download Tool (eDT). eDT is a new operator tool that generates magnet design setpoints for various machine energies and pass configurations. eDT was developed in the effort towards a process for reducing machine configuration time and reproducibility by way of an accurate accelerator model.

43 PARTICLE ACCELERATORS↗

First attempt of at-cavity cryogenic X-ray detection in a CEBAF cryomodule for field emission monitoring

We report on the first result of at-cavity X-ray detection in a CEBAF cryomodule for field emission monitoring. In the 8-cavity cryomodule F100, two silicon diodes were installed near the end flange of each cavity. Each cavity was individually tested during the cryomodule test in JLab’s cryomodule test facility. The behaviors of these at-cavity cryogenic X-ray detectors were compared with those of the standard ‘in air’ Geiger-Muller (G-M) tubes. Our initial experiments establish correlation between X-ray response of near diodes and the field emission source cavity in the 8-cavity string. For two out of these eight cavities, we also carried out at-cavity X-ray detection experiment during their vertical testing. The aim is to track field emission behavior uniquely from vertical cavity testing to horizontal cavity testing in the cryomodule. These preliminary results confirmed our expectation and warrant further effort toward the establishment of permanent at-cavity cryogenic X-ray detection for SRF development and operation.

43 PARTICLE ACCELERATORS↗

First e⁻/γ Commissioning Results for the GlueX Experiment/Hall D at CEBAF

Experimental Hall D, with flagship experiment GlueX, was constructed as part of the 12 GeV CEBAF upgrade. A new magnetically extracted electron beam line was installed to support this hall. Bremsstrahlung photons from retractable radiators are delivered to the experiment through a series of collimators following a long drift to allow for beam convergence. Coherent Bremsstrahlung generated by interaction with a diamond radiator will achieve a nominal 40% linear polarization and photon energies between 8.5 and 9 GeV from 12.1 GeV electrons, which are then tagged or diverted to a medium power 60kW electron dump. The expected photon flux is 10 7 -10 8 Hz. This paper discusses the experimental line design, commissioning experience gained since first beam in spring 2014, and the present results of beam commissioning by the experiment.

43 PARTICLE ACCELERATORS↗

Observation and Mitigation of Multipass BBU in CEBAF

Abstract The Continuous Electron Beam Accelerator Facility (CEBAF) recirculating accelerator at Jefferson Lab consists of two linacs carrying beam for up to five passes of acceleration. The design of this accelerator anticipated the onset of multipass beam break-up (BBU) at a beam current of approximately 20 mA, far above the operational peak current of 200 uA. For more than a decade of operation, no sign of BBU was ever observed. However, a specially designed acceleration cavity in a cryomodule installed in the summer of 2007 has been observed to cause BBU instability with as low as 40 uA of injected beam current. This presented an opportunity to study BBU in a five-pass accelerator. In this paper we will discuss multipass BBU, present observational data, and discuss the ways we have developed to maintain the instability threshold current to values above those required for operation.

43 PARTICLE ACCELERATORS↗

An overview of how parity-violating electron scattering experiments are performed at CEBAF

Parity-violating electron-scattering experiments represent an important focus of the nuclear physics experimental program at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. These experiments pose significant challenges because the scattering asymmetries can be very small, of the order parts-per-million and smaller. To succeed, the properties of the electron beam such as current, position, size and energy, must be very nearly identical in the two electron-polarization spin states (parallel and anti-parallel relative to the direction of beam motion at the scattering target). This paper describes the origins of unwanted helicity-correlated beam asymmetries present on the electron beam and methods to minimize them to acceptable levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of highly-constrained splitters for the FFA@CEBAF energy upgrade study

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is investigating a significant energy upgrade utilizing Fixed-Field Alternating-gradient (FFA) recirculating arcs. This upgrade requires the design of complex horizontal beam splitters to manage up to six concurrent beam passes. This paper presents the conceptual design of these splitters, which are subject to severe physical constraints imposed by the existing accelerator tunnel and multifaceted beam dynamics requirements for matching into the permanent-magnet FFA arcs. The design methodology, centered on multi-pass simulations in the Bmad toolkit, is detailed from the initial geometric layout through the advanced optics matching. Key results include a robust geometric arrangement that fits within the spatial boundaries and the development of multiple, flexible optics matching solutions. Furthermore, the design integrates a viable scheme for extracting high-energy beams for the experimental halls, a critical operational requirement. This work establishes a comprehensive and viable conceptual design, forming a baseline for future engineering and performance optimization studies.

Bodenstein, R.M. [Thomas Jefferson National Accele↗

Studies of Nucleon Form Factors with 12 GeV CEBAF and SuperBigBite

The elastic electromagnetic form factors are among the most fundamental quantities that describe the ground-state structure of the proton and neutron. Precision data of the form factors over a wide kinematical range provide a powerful test of current theories of hadron structure. A number of experiments aiming to measure the electric and magnetic elastic form factors of the neutron, G{sub E}{sup n} and G{sub M}{sup n}, and proton, G{sub E}{sup p}, at very high momentum transfer, up to the range of Q{sup 2} = 10-14 (GeV/c){sup 2}, are planned to be carried out with the future 11 GeV electron beam of the upgraded CEBAF at Jefferson Lab. These experiments will determine the nucleon form factors with unprecedented precision to Q{sup 2}-values up to three times higher than those of existing data. We review the approved proposals and the conceptual design of a new spectrometer, SuperBigBite, that will be used in these and other future experiments at Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A proposal for antiparallel acceleration of positrons using CEBAF

Here, we present a scheme for positron beam acceleration in CEBAF antiparallel to the normal electron path, requiring no change in polarity of the magnet systems. This feature is essential to the principal benefit: enabling extremely simple configuration changes between conventional (clockwise) e - acceleration and counter clockwise e + acceleration. Additionally, it appears possible to configure the accelerating cavity phases to support concurrent acceleration of the electron and positron beams. The last mode also may enable use of the higher peak current electron beam for system diagnostics. The inherent penalty of the concurrent mode in acceleration efficiency and increased energy spread may render this a commissioning-only diagnostic option, but the possibility appears worthy of consideration.

43 PARTICLE ACCELERATORS↗

Measurement of deeply virtual Compton scattering off 4 He with the CEBAF Large Acceptance Spectrometer at Jefferson Lab

We report on the measurement of the beam spin asymmetry in the deeply virtual Compton scattering off $^4$He using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab using a 6 GeV longitudinally polarized electron beam incident on a pressurized $^4$He gaseous target. We detail the method used to ensure the exclusivity of the measured reactions, in particular the upgrade of CLAS with a radial time projection chamber to detect the low-energy recoiling $^4$He nuclei and an inner calorimeter to extend the photon detection acceptance at forward angles. Our results confirm the theoretically predicted enhancement of the coherent ($e^4$He$~\to~e'$$^4$He$'\gamma'$) beam spin asymmetries compared to those observed on the free proton, while the incoherent ($e^4$He$~\to~e'$p$'\gamma'$X$'$) asymmetries exhibit a 30$\%$ suppression. From the coherent data, we were able to extract, in a model-independent way, the real and imaginary parts of the only $^4$He Compton form factor, $\cal H_A$, leading the way toward 3D imaging of the partonic structure of nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of remanent magnetic field on the heat load of original CEBAF cryomodule

The heat load of the original cryomodules for the CEBAF accelerator is ~50% higher than the target value of 100 W at 2.07 K for refurbished cavities operating at an accelerating gradient of 12.5 MV/m. This issue is due to the quality factor of the cavities being ~50% lower in the cryomodule than when tested in a vertical cryostat, even at low RF field. Previous studies were not conclusive about the origin of the additional losses. We present the results of a systematic study of the additional losses in a five-cell cavity from a decommissioned cryomodule after attaching components, which are part of the cryomodule, such as the cold tuner, the He tank and the cold magnetic shield, prior to cryogenic testing in a vertical cryostat. Flux-gate magnetometers and temperature sensors are used as diagnostic elements. Different cool-down procedures and tests in different residual magnetic fields were investigated during the study. Here, three flux-gate magnetometers attached to one of the cavities installed in the refurbished cryomodule C50-12 confirmed the hypothesis of high residual magnetic field as a major cause for the increased RF losses.

43 PARTICLE ACCELERATORS↗

Probing charged lepton flavor violation with a positron beam at CEBAF (JLAB)

The addition of a high intensity 11 GeV polarized positron beam at the Continuous Electron Beam Accelerator Facility (CEBAF) at JLAB would allow for a search of Charged Lepton Flavor Violation (CLFV) via the process $e^+N \rightarrow \mu^+ X$. The proposed Solenoidal Large Intensity Detector (SoLID) spectrometer, in the configuration with muon chambers, would be ideal for such CLFV searches. Various new physics scenarios, including the phenomenologically convenient Leptoquark (LQ) framework, predict CLFV rates that are within reach of current or planned experiments. A positron beam with instantaneous luminosity, ${\cal L}\sim 10^{38}$ cm$^{-2}$s$^{-1}$, could improve on existing HERA limits by two or three orders of magnitude. The availability of positron beam polarization would also allow for distentangling CLFV effects mediated by left-handed vs. right-handed LQs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Initial Implementation Of Machine Learning System for SRF Cavity Fault Classification at CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is high power CW electron accelerator. It uses a mixture of two types of SRF modules, older, lower energy C20/C50 modules and newer higher energy C100 modules, arrayed in two anti-parallel linear accelerators. Accurately classifying the type of cavity faults is essential to maintaining and improving accelerator performance. Each C100 cryomodule contains eight 7-cell cavities. When a cavity fault occurs within a cryomodule, all eight cavities generate 17 waveforms each containing 8192 points. This data is exported from EPICS and saved for review. Analysis of these waveforms is time intensive and requires subject matter expertise (SME). SMEs examine the data from each event and label it according to one of several known cavity fault types. Multiple machine learning models have been developed on this labeled dataset with sufficient performance to warrant the creation of a limited machine learning software system for use by accelerator operations staff. This paper discusses the transition from model development to implementation of a prototype system.

Carpenter, A.↗

THE NEW DESIGN FOR CAPTURE CAVITY OF CEBAF

In CEBAF, the electron beam from the injector must be sufficiently relativistic to match a 1 GeV recirculated beam in the first linac. The electron beam is produced with a ~130 keV electron gun, then accelerated by a room temperature, graded-beta standing wave linac, capture section, from 130 keV to 510 keV before enters two 5-cell superconducting RF cavities for further acceleration. Present capture cavity is a 5-cell side-coupled cavity. We designed a new slot-coupled cavity which has lower power consumption and more compact size.

Wang, Shaoheng↗

Four Beam Generation for Simultaneous Four-Hall Operation at CEBAF

As part of the CEBAF 12 GeV upgrade at Jefferson Lab, a new experimental hall was added to the existing three halls. To deliver beam to all four halls simultaneous-ly, a new timing pattern for electron bunches is needed at the injector. This pattern change has consequences for the frequency of the lasers at the photogun, beam behavior in the chopping system, beam optics due to space charge, and setup procedures. We have successfully demonstrated this new pattern using the three existing drive lasers. The implementation of the full system will occur when the fourth laser is added and upgrades to the Low Level RF (LLRF) are complete. In this paper we explain the new bunch pattern, the challenges for setting and measuring the pattern such as 180° RF phase ambiguity, addition of the fourth laser to the laser table and LLRF upgrade.

Kazimi, Reza↗

Software Tools for Emittance Measurement and Matching for 12 GeV CEBAF

This paper discusses model-driven setup of the Continuous Electron Beam Accelerator Facility (CEBAF) for the 12GeV era, focusing on qsUtility. qsUtility is a set of software tools created to perform emittance measurements, analyze those measurements, and compute optics corrections based upon the measurements.qsUtility was developed as a toolset to facilitate reducing machine configuration time and reproducibility by way of an accurate accelerator model, and to provide Operations staff with tools to measure and correct machine optics with little or no assistance from optics experts.

Turner, Dennis L.↗

New Methods for Dispersion Measurement and Correction for 12GeV CEBAF

This paper discusses methods for dispersion measurement and correction for the Continuous Electron Beam Accelerator Facility (CEBAF) for the 12GeV era. New methods will be compared with methods used during the 6GeV era. New software tools which implement the new methods will be discussed, along with a method for automating dispersion measurement and correction. New dispersion measurement and correction methods and tools are being implemented to provide more deterministic results and to reduce machine setup time.

Turner, Dennis L.↗

SRF Cavity Fault Classification Using Machine Learning At CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is the first large high power CW recirculating electron accelerator to make use of SRF accelerating structures. The structures are configured in two anti-parallel linacs connected by arcs. Each linac consists of twenty C20/C50 cryomodules each containing eight 5-cell cavities and five C100 upgrade cryomodules each containing eight 7-cell cavities. Accurately classifying the source of cavity faults is critical for improving accelerator performance. A cavity fault triggers a waveform acquisition process where 17 waveform records sampled at 5 kHz are recorded for each of the 8 cavities in the affected cryomodule. The waveform record length is sufficiently long for transient microphonic effects to be observable. This data combined with archived signals sampled at 10 Hz are used to classify faults. Significant time is required for a subject matter expert to analyze and identify the intra-cavity signatures of imminent faults. This paper describes a path forward that utilizes machine learning for automatic fault classification. Post-training identification of the physical origins of faults are discussed, as are potential machine-trained model-free implementations of trip avoidance procedures. These methods should provide new insights into cavity fault mechanisms and facilitate intelligent optimization of cryomodule performance

Solopova, A.↗