Search NASA⌕ Search

SEARCH · Search NASA

Results for “CM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Genome assembly UFMG-CM Y6992

The yeast genus Torulaspora (subphylum Saccharomycotina, family Saccharomycetaceae) is mostly known from its type species T. delbrueckii, a frequent colonizer of wine and sourdough bread fermentations. The genus currently contains ten species that are typically found in various natural terrestrial environments in temperate and tropical climates. Here we employ taxogenomic analyses to investigate a large collection of Torulaspora strains obtained in multiple surveys we carried out in Asia, Australasia, North America, South America, and Europe, and to which we added several strains maintained in culture collections. Our analyses detected twelve novel species that are formally described here, thereby more than doubling the species diversity of Torulaspora. We also sketch a genotype-phenotype map for the genus and show how key genes have evolved in concert with the physiological traits they control. This dramatic increase in the number of species in the genus Torulaspora highlights how limited the current inventory of fungal taxa is. It also shows how integrated taxogenomics approaches can foster the assessment of species circumscriptions in fungi, especially when classical approaches relying on DNA barcode regions give inconclusive results.

Sampaio, Jose P. [UCIBIO, Departamento de Ciências↗

Pichia sp. KDB-2024a strain:UFMG-CM-Y531 Genome sequencing

Pichia senei was isolated from necrotic cactus tissues of Cereus saddianus and Micranthocereus dolichospermaticus, and from water tank (phytotelmata) of the bromeliad species Bromelia karatas, collected in the state of Tocantins, Brazil.

bromeliads↗

Comprehensive Symmetric-Hybrid ring design for pEDM experiment at below $10^{-29}e\cdot$cm

A concise demonstrative summary of the Symmetric Hybrid ring design for the storage ring proton electric dipole moment experiment is presented. Critical issues such as lattice design, background electrical fields,geometrical phase, general relativity, spin coherence time and polarimeter systematics are presented. Overall, we find that with the currently proposed design iteration, systematic error sources are reduced by orders of magnitude and that the ring alignment requirements are within the currently available technology.

43 PARTICLE ACCELERATORS↗

Fermilab PIP-II CDS and CM Cryogenic Controls System

Details on Final design for Cryogenic Electrical & Controls System for Fermilab' s next-gen particle accelerator PIP-II. Electrical Controls System includes instrumentation and controls of Cryogenics Distribution System and Cryomodules. Design includes Siemens PCS7 Controls System with 26 Remote IO Rittal Cabinets and 48 Relay Racks for Temperature Readouts, Valve Positioners, Level, Heater Controls etc. Electrical Drawings and Design have been completed with focus now on fabrication of the 26 Rittal Cabinets and 48 Relay Racks. All materials have been procured. EPICS will be used as a SCADA system communicating to S7 Controllers via OPC UA.

Patel, Pratik [Fermilab]↗

Author Correction: Proton irradiation-decelerated intergranular corrosion of Ni-Cr alloys in molten salt

In the original version of this article, numbers for the beam current densities were incorrectly given as 1.5, 2.0, and 2.5 mA cm -2 in various locations, instead of the correct values 0.3, 0.4, and 0.5 mA cm -2 . This was owing to a measurement error coming from the indirect correspondence between the Faraday cup and the beam profile monitor (BPM) on the accelerator as the proton beam traveling along the beamline resulted in mismatching between calculated values and real beam currents, which were obtained by ex-situ calibration. The following changes have been made in the correct version. The eighth sentence of the Results, and the figure legend of Fig. 2j state '0.3, 0.4, 0.5 mA cm -2 ' in place of '1.5, 2.0, 2.5 mA cm -2 '. The figure legend of Fig. 1j–l states '0.5, 0.4, 0.3 mA cm -2 ' in place of '2.5, 2.0, 1.5 mA cm -2 '. Figure 1e states '0.5 mA cm -2 ' in place of '2.5 mA cm -2 ', Fig. 1h states '0.4 mA cm -2 ' in place of '2.0 mA cm -2 ', and Fig. 1k states ‘0.3 mA cm -2 ' in place of ‘1.5 mA cm -2 '. Figure 2c states '0.5 mA cm -2 ' in place of '2.5 mA cm -2 ', Fig. 2d states '0.4 mA cm -2 ' in place of '2.0 mA cm -2 ', and Fig. 2e states '0.3 mA cm -2 ' in place of '1.5 mA cm -2 '. Figure 2j and k states ‘0.3 mA cm -2 ', '0.4 mA cm -2 ', '0.5 mA cm -2 ' in place of '1.5 mA cm -2 ', '2.0 mA cm -2 ', and '2.5 mA cm -2 ', respectively. The figure legend of Fig. 3b states '0.4 mA cm -2 ' in place of '2.0 mA cm -2 '. The figure legend of Supplementary Fig. 1 states '0.5 mA cm -2 ' in place of '2.5 mA cm -2 '. This has been corrected in the PDF and HTML versions of the Article.

36 MATERIALS SCIENCE↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Critical Minerals from Waste Streams in the Powder River Basin of Wyoming and Montana, USA

Background/Objectives. Critical minerals (CM) are essential for numerous industrial and defense applications, including green technologies that will help to meet carbon emission reduction goals. Many CM are currently mined and processed in countries that lack stringent environmental and labor regulations. Unconventional sources such as existing industrial waste streams could play a part in building an ethical CM supply chain. Additionally, waste streams created in the extraction and processing of CM could be used for other industrial or commercial purposes, thereby reducing waste and advancing a circular economy. Approach/Activities. The Department of Energy funded Powder River Basin (PRB) CORE-CM project is exploring all aspects of the carbon ore, rare earth element (REE), and CM value chain, including the potential for extraction of CM from industrial waste streams in the basin. Waste streams that have potential as CM feedstocks are being inventoried to assess the concentration of CM in each waste stream and to estimate volume and accessibility. Although basin-specific technologies for extraction of CM are still in development, waste streams that may be produced during these processes are being cataloged and mapped to potential secondary uses. Results/Lessons Learned. Initial studies of the CM potential of PRB coal ash show that this waste stream contains concentrations of greater than 300 ppm total REE (Bagdonas et al., 2022, Renewable and Sustainable Energy Reviews). Moreover, calcium-rich PRB coal ash is amenable to REE extraction (Taggart et al., 2016, Environmental Science and Technology). Wyoming coal is shipped to 28 states, meaning that coal ash produced at power stations across the US represents a potential widespread resource for the extraction of REE. In addition to coal mining and coal fired electricity generation, the PRB is home to other energy industries including oil and gas production, in-situ uranium mining, and bentonite mining. Historically, precious and base metal mining has taken place on the perimeter of the PRB. Waste streams from these industries are currently being evaluated for their CM potential. Assessing the CM resource potential of waste streams could contribute to the development of an ethical CM supply chain. Results from these studies can be replicated for other waste streams, increasing the likelihood of successful creation of circular economies.

Phillips, Erin↗

Optimal spectral resolution for solids and liquids using FT and other infrared spectrometers: How much resolution do you really need?

In this study we investigate the possibility of using spectral resolutions for infrared measurements of solids and liquids that are not powers of two, e.g. are not at 1, 2, 4, 8, or 16 cm-1 resolution. In almost all reported literature of the last fifty years the resolution used to record for a Fourier transform infrared spectrum has been a power of two. This stems from the fact that 1) the Cooley-Tukey algorithm used to compute such a transform was constructed to use only powers of two and was also driven by 2) the fact that the computing horsepower required to compute the Fourier transform increases as N?log?_2 (N), where N is the number of points in the interferogram (spectrum). For typical spectra, however, the CPU time is no longer a consideration. Our study is based on both liquid and solid spectra, all of which were recorded at 2 cm-1 resolution. There were at total of 70 solids spectra representing 2,472 spectral peaks and 61 liquids spectra (1,765 spectral peaks), each peak being inspected for being singlet / multiplet in nature. Of the 1,765 liquid bands examined, only 27 had widths less than 5 cm-1. Of the 2,472 solid bands examined, only 39 peaks have widths less than 5 cm-1. For liquids, the mean peak width is 24.7 cm-1 but the median peak width is 13.7 cm-1, and, similarly, for solids, the mean peak width is 22.2 cm-1 but the median peak width is 11.2 cm-1. In both cases, solids and liquids, a skewed peak widths distribution was observed, the peak of the distribution representing narrower bands in the 7 to 9 cm-1 FWHM range but displaying a long tail to the very broad bands, with some displaying spectral widths of 100 cm-1 or more. Because one of the most important criteria for successful instrumental design in IR spectroscopy is the spectral resolution, the data were further analyzed showing that a value to resolve 95% of all bands is 5.7 cm-1 for liquids and 5.3 cm-1 for solids; such a resolution would capture the native linewidth (no instrumental broadening) of 95% of all the solids and liquid bands, respectively. Based on the present results we suggest that, when accounting only for intrinsic linewidths an optimized resolution of 6.0 cm-1 will capture 91% of all condensed-phase bands for IR detection of chemical, mineral, and biological materials.

Forland, Brenda M.↗

Optimal Spectral Resolution for Infrared Studies of Solids and Liquids

Due to a legacy originating in the limited capability of early computers, the spectroscopic resolution used in Fourier transform infrared spectroscopy and other systems has largely been implemented using only powers of two for more than 50 years. In this study, we investigate debunking the spectroscopic lore of, e.g., using only 2, 4, 8, or 16 cm −1 resolution and determine the optimal resolution in terms of both (i) a desired signal-to-noise ratio and (ii) efficient use of acquisition time. The study is facilitated by the availability of solids and liquids reference spectral data recorded at 2.0 cm −1 resolution and is based on an examination in the 4000–400 cm −1 range of 61 liquids and 70 solids spectra, with a total analysis of 4237 peaks, each of which was also examined for being singlet/multiplet in nature. Of the 1765 liquid bands examined, only 27 had widths <5 cm −1 . Of the 2472 solid bands examined, only 39 peaks have widths <5 cm −1 . For both the liquid and solid bands, a skewed distribution of peak widths was observed: For liquids, the mean peak width was 24.7 cm −1 but the median peak width was 13.7 cm −1 , and, similarly, for solids, the mean peak width was 22.2 cm −1 but the median peak width was 11.2 cm −1 . While recognizing other studies may differ in scope and limiting the analysis to only room temperature data, we have found that a resolution to resolve 95% of all bands is 5.7 cm −1 for liquids and 5.3 cm −1 for solids; such a resolution would capture the native linewidth (not accounting for instrumental broadening) for 95% of all the solids and liquid bands, respectively. After decades of measuring liquids and solids at 4, 8, or 16 cm −1 resolution, we suggest that, when accounting only for intrinsic linewidths, an optimized resolution of 6.0 cm −1 will capture 91% of all condensed-phase bands, i.e., broadening of only 9% of the narrowest of bands, but yielding a large gain in signal-to-noise with minimal loss of specificity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinetic Control of Angstrom-Scale Porosity in 2D Lattices for Direct Scalable Synthesis of Atomically Thin Proton Exchange Membranes

Angstrom-scale pores introduced into atomically thin 2D materials offer transformative advances for proton exchange membranes in several energy applications. Here, we show that facile kinetic control of scalable chemical vapor deposition (CVD) can allow for direct formation of angstrom-scale proton-selective pores in monolayer graphene with significant hindrance to even small, hydrated ions (K + diameter ~6.6 Å) and gas molecules (H 2 kinetic diameter ~2.9 Å). We demonstrate centimeter-scale Nafion|Graphene|Nafion membranes with proton conductance ~3.3–3.8 S cm –2 (graphene ~12.7–24.6 S cm –2 ) and H + /K + selectivity ~6.2–44.2 with liquid electrolytes. The same membranes show proton conductance ~4.6–4.8 S cm –2 (graphene ~39.9–57.5 S cm –2 ) and extremely low H 2 crossover ~1.7 × 10 –1 – 2.2 × 10 –1 mA cm –2 (~0.4 V, ~25 °C) with H 2 gas feed. We rationalize our findings via a resistance-based transport model and introduce a stacking approach that leverages combinatorial effects of interdefect distance and interlayer transport to allow for Nafion|Graphene|Graphene|Nafion membranes with H + /K + selectivity ~86.1 (at 1 M) and record low H 2 crossover current density ~2.5 × 10 –2 mA cm –2 , up to ~90% lower than state-of-the-art ionomer Nafion membranes ~2.7 × 10 –1 mA cm –2 under identical conditions, while still maintaining proton conductance ~4.2 S cm –2 (graphene stack ~20.8 S cm –2 ) comparable to that for Nafion of ~5.2 S cm –2 . Furthermore, our experimental insights enable functional atomically thin high flux proton exchange membranes with minimal crossover.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Characterization of an Extremely-Sensitive, Large-Volume Gamma-Ray Spectrometer for Environmental Samples

A large volume gamma spectrometer was designed and constructed to analyze foodstuffs and environmental samples having low radionuclide concentrations. This system uses eight 11-cm × 42.5-cm × 5.5-cm NaI(Tl) detectors, chosen due to their relatively high sensitivity and availability and arranged in an octagonal configuration. The sensitive volume of the system is ~28 cm in diameter and ~42 cm deep. Shielding consists of an 86-cm × 86-cm square, 64-cm-tall lead brick enclosure with 18-cm-thick lead walls lined by 0.3-cm-thick copper plates. An aluminum top was machined to suspend the detectors within this shield. The shielding reduces background counts by 72% at 100 keV and 42% at 1,000 keV. The positional variability in sensitivity of the well was determined by both simulation and experiment. A 2.1-L volume of nearly uniform sensitivity, varying less than 10%, exists in the well's center. Energy resolutions of 14.6% and 7.8% were measured for 241 Am and 137 Cs, respectively. Energy resolution shows a 0.2% variation for both 241 Am and 137 Cs as a function of position within all regions of the well’s central sensitive volume. Dead time was also determined to be less than 35% for all sources measured in the system, the largest of which had an activity of 1,760 kBq. Simulated results for various source geometries show higher counts for smaller samples, especially at lower energies due to less attenuation of low energy photons. In conclusion, minimum detectable activities were determined for all source energies used, less than 5.1 Bq kg -1 for reasonable background and sample counting times.

47 OTHER INSTRUMENTATION↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of several high-resolution infrared bands of perdeutero-spiropentane, C5D8

Perdeutero-spiropentane (C5D8) has been synthesized and infrared spectra were taken from 400 to 4000 cm-1 at low sample pressures in a 22 meter multipass cell. The spectral resolution (0.0015 cm-1) reveals thousands of individual rovibrational transitions for several fundamental bands occurring in the spectral region of 500 to 1100 cm-1. C5D8 ground state constants reported in a previous study of a ?15 parallel band at 1054 cm-1 [1] were improved significantly in the present work by adding combination-differences derived from ?16 parallel and ?24 perpendicular band analyses. The larger data set at higher J values also allowed determination of the ground state K? = 2 splitting constant (?2? = 0.76(2) ×10-9 cm-1). For ?16, the band origin is 847.16933(5) cm-1 and changes in upper state rotational constants are ?A = –0.0013411(5) and ?B = –0.0002021(1) (in units of cm-1). Overlapping, and in Fermi resonance with ?16, is a second parallel band which, from Gaussian calculations at the anharmonic level, is assigned as the b2 combination ?8+?12, with band origin of 840.5434(1) and ?A = –0.0003500(7) and ?B = –0.0003502(1) cm-1. For ?24 analogous values are 556.41453(2) and ?A = –0.00032295(9) and ?B = –0.00016782(4) cm-1. The analyses also yields accurate values for the changes in both quartic and sextic centrifugal distortion constants and, for ?24, values for the l-doubling constants q+ and q-. Theoretical calculations of the rovibrational parameters aided in the analysis and the numerical values are in good agreement with experimental results.

Nibler, Joseph W.↗

Investigation of Mass Transfer and Sorption in CO 2 /Brine/Rock Systems via In Situ FT-IR

CO 2 geological storage in deep saline formations is considered a promising method to mitigate anthropogenic CO 2 emissions and, thereby, minimize changes to the Earth’s atmosphere. A fundamental understanding of CO 2 mass transfer and sorption phenomena in brine-saturated reservoir formations is necessary to understand the long-term fate of injected CO 2 as it is subjected to different (physical, dissolution, and mineral) trapping mechanisms. In this work, we investigate CO 2 sorption in brine-saturated and dry Mt. Simon sandstone samples via in-situ Fourier Transform infrared spectroscopy (FT-IR) at elevated pressures, ranging from 0.3 MPa to 8.3 MPa, at a temperature of 50 ⁰C. The FT-IR spectra of bulk-phase CO 2 were simultaneously recorded under the same conditions. For bulk-phase CO 2 , we observed, in agreement with past studies, a doublet peak at 2361 cm -1 and 2336 cm -1 and another peak (ν 2 bending mode) at 667 cm -1 . With increasing pressure, the position of the peak at 667 cm -1 remains invariant, however, when crossing into the supercritical region the doublet peak degenerates onto a single peak at 2336 cm -1 with a barely visible shoulder at 2361 cm -1 . The bulk CO 2 data provide a perfect fit for Beer’s law for the whole range of pressure conditions. For the dry sample, the IR spectrum is experimentally indistinguishable from the bulk CO 2 spectrum, signifying that if physical adsorption occurs to any significant extent, the adsorbed CO 2 molecules are not substantially more rotationally constrained than the dense bulk CO 2 molecules. For the brine-saturated sample, we observe a strong band centered at 2342 cm -1 and a small companion peak at 2360-2361 cm -1 that degenerates into a barely visible shoulder peak at the higher pressures. The 2342 cm -1 band has been previously observed by other investigators for CO 2 dissolved in bulk water/brine as well during its adsorption on a variety of other wet natural porous media. We observe no peaks corresponding to bicarbonate or carbonate bulk species, which correlates well with the prior literature on similar low-pH aqueous solutions. The integrated peak area for the CO 2 sorbed in the brine-saturated sample correlates linearly with its solubility in the same bulk brine, as measured separately via a PVT-cell approach. Here, this validates the accuracy of both techniques, and the potential of the FT-IR method to be used in the study of mass transfer and adsorption in such systems. To that effect, a simple mathematical model is presented to analyze the FT-IR data to determine the CO 2 effective diffusivity in the brine-saturated sandstone sample.

58 GEOSCIENCES↗