Search NASA⌕ Search

SEARCH · Search NASA

Results for “COLUMNS - BUCKLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Water Column Respiration in the Yakima River Basin is Explained by Temperature, Nutrients and Suspended Solids

Understanding aquatic ecosystem metabolism involves the study of two key processes: carbon fixation via primary production and organic C mineralization as total ecosystem respiration (ERtot). In streams and rivers, ERtot includes respiration in the water column (ERwc) and in the sediments (ERsed). While literature surveys suggest that ERsed is often a dominant contributor to ERtot, recent studies indicate that the relative influence of sediment-associated processes versus water column processes can fluctuate along the river continuum. Still, a comprehensive understanding of the factors contributing to these shifts within basins and across stream orders is needed. Here we contribute to this need by measuring ERwc and collecting water samples across 47 sites in the Yakima River basin, Washington, USA. We found that ERwc rates varied throughout the basin during baseflow conditions, ranging from –7.38 to 0.36 g O2 m?3 d?1, and encompassed the range of ERwc literature values. Additionally, by comparing to ERtot estimates for rivers across the contiguous United States, we suggest that the contribution of ERwc rates to reach-scale ERtot rates across the Yakima River was likely highly variable, but we did not test this directly. We observed that temperature, nutrient concentrations (dissolved organic carbon, total dissolved nitrogen), and total suspended solids explained 41% of ERwc variability across the basin. Our findings highlight the potential relevance of water column processes in aquatic ecosystem metabolism, with the Yakima River basin serving as an environmentally diverse river network representative of the larger Columbia River basin that spans much of the Pacific Northwest region of the United States. Our results are generally congruent with previous work, suggesting that the observed variability and suite of associated environmental factors influencing ERwc are potentially transferable across basins.

Laan, Maggi M.↗

Transient flow and heating characteristics in a pinched plasma column.

The generation of axial flow and heating of an argon plasma in a pinched plasma column of a pulsed, linear z-pinch device was examined experimentally and analytically. Transient (about 5 microsec) axial pressure profiles identify three characteristic periods in the column history. These include (1) strong axial pressure asymmetry indicative of plasma streaming, (2) isotropic, rapidly rising plasma pressure indicative of plasma heating, and (3) column breakup. An efficient conversion of radial collapse to axial streaming velocity is identified. Mechanisms for such an effect and subsequent heating are evaluated; significance to transients in pulsed plasma accelerators is identified.

York, T. M.↗

Column densities resulting from shuttle sublimator/evaporator operation

The proposed disposal of H2O from the shuttle fuel cell operation by ejecting it in vapor form through a supersonic nozzle at the rate of 100 lb/day has been investigated from the point of view of the possible interference to astronomical experiments. If the nozzle is located at the tail and directed along the shuttle longitudinal axis, the resulting column density will be less than 10 to th 12th power molecules/sq cm at viewing angles larger than 48 deg above the longitudinal axis. The molecules in the trail will diffuse rapidly. The column density contribution from molecules expelled on the previous orbit is 1.3 x 10 to the 8th power molecules/sq cm. This contribution diminishes by the inverse square root of the number of orbits since the molecules were expelled. The molecular backscatter from atmospheric molecules is also calculated. If the plume is directed into the flight path, the column density along a perpendicular is found to be 1.5 x 10 to the 11th power molecules/sq cm. The return flux is estimated to be of the order of 10 to the 12th power molecules/sq cm/sec at the stagnation point. With reasonable care in design of experiments to protect them from the backscatter flux of water molecules, the expulsion of 100 lb/day does not appear to create an insurmountable difficulty for the shuttle experiments.

Naumann, R. J.↗

Molecular column densities in selected model atmospheres

From an examination of predicted column densities, the following conclusions were drawn: (1) The SiO ought to be visible in carbon stars which were generated from triple alpha burning, but absent from carbon stars generated from the CNO bi-cycle. (2) Variation in the observed relative strengths of TiO and ZrO is indicative of real differences in the ratio Ti/Zr. (3) The TiO/ZrO ratio shows a small variation as C/O and effective temperature is changed. (4) Column density of silicon dicarbide (SiC2) is sensitive to abundance, temperature, and gravity; hence all relationships between the strength of SiC2 and other stellar parameters will show appreciable scatter. There is however, a substantial luminosity effect present in the SiC2 column densities. (5) Unexpectedly, SiC2 is anti-correlated with C2. (6) The presence of SiC2 in a carbon star eliminates the possibility of these stars having temperatures greater than or equal to 3000 K, or being produced through the CNO bi-cycle.

Johnson, H. R.↗

Preparative liquid column electrophoresis of T and B lymphocytes at gravity = 1

Vertical liquid columns containing low-molecular-weight dextran density gradients can be used for preparative lymphocyte electrophoresis on earth, in simulation of zero gravity conditions. Another method that has been tested at 1 g, is the electrophoresis of lymphocytes in an upward direction in vertical columns. By both methods up to 100 million lymphocytes can be separated at one time in a 30-cm glass column of 8-mm inside diameter, at 12 V/cm, in two hours. Due to convection and sedimentation problems, the separation at 1 g is less than ideal, but it is expected that at zero gravity electrophoresis will probe to be a uniquely powerful cell separation tool.

Van Oss, C. J.↗

Experimental study of the stability and flow characteristics of floating liquid columns confined between rotating disks

A low Bond number simulation technique was used to establish the stability limits of cylindrical and conical floating liquid columns under conditions of isorotation, equal counter rotation, rotation of one end only, and parallel axis offset. The conditions for resonance in cylindrical liquid columns perturbed by axial, sinusoidal vibration of one end face are also reported. All tests were carried out under isothermal conditions with water and silicone fluids of various viscosities. A technique for the quantitative measurement of stream velocity within a floating, isothermal, liquid column confined between rotatable disks was developed. In the measurement, small, light scattering particles were used as streamline markers in common arrangement, but the capability of the measurement was extended by use of stereopair photography system to provide quantitative data. Results of velocity measurements made under a few selected conditions, which established the precision and accuracy of the technique, are given. The general qualitative features of the isothermal flow patterns under various conditions of end face rotation resulting from both still photography and motion pictures are presented.

Fowle, A. A.↗

Non-linear wave interaction in a magnetoplasma column. I - Theory. II Experiment

The paper presents an analysis of non-linear three-wave interaction for propagation along a cylindrical plasma column surrounded either by a metallic boundary, or by an infinite dielectric, and immersed in an infinite, static, axial magnetic field. An averaged Lagrangian method is used and the results are specialized to parametric amplification and mode conversion, assuming an undepleted pump wave. Computations are presented for a magneto-plasma column surrounded by free space, indicating that parametric growth rates of the order of a fraction of a decibel per centimeter should be obtainable for plausible laboratory plasma parameters. In addition, experiments on non-linear mode conversion in a cylindrical magnetoplasma column are described. The results are compared with the theoretical predictions and good qualitative agreement is demonstrated.

Larsen, J.-M.↗

Interstellar C IV and Si IV column densities toward early-type stars

Equivalent widths and deduced column densities of Si IV and C IV are examined for 18 early-type close binaries, and physical processes responsible for the origin of these ions in the interstellar medium are investigated. The available C IV/Si IV column density ratios typically lie within a narrow range from 0.8 to 4.5, and there is evidence that the column density of C IV is higher than that of N V along most lines of sight, suggesting that C IV is not formed in the same hot region as O VI. In addition, the existence of regions with a narrowly defined new temperature range around 50,000 deg K is indicated. The detection of the semitorrid gas of Bruhweiler, Kondo, and McCluskey (1978, 1979) is substantiated, and the relation of this gas to the observations of coronal gas in the galactic halo is discussed.

Bruhweiler, F. C.↗

Development of and fabrication of high resolution gas chromatographic capillary columns

Gas chromatographic columns which are used in the trace gas analyzer (TGA) for the space shuttle are coated with a polyoxyethylene lauryl ether. This stationary phase is of medium polarity and has a temperature limit of 160 C. A polymer for this application which has an improved thermal stability is investigated. The use of fused silica capillary columns with specially bonded phases as well as an introduction system (on column) was also studied.

Zlatkis, A.↗

Securing mechanism for the deployable column of the Hoop/Column antenna

The Column Longeron Latch (CLL) was designed and developed as the securing mechanism for the deployable, telescoping column of the Hoop/Column antenna. The column is an open lattice structure with three longerons as the principal load-bearing members. It is divided into telescoping sections that are deployed after the antenna is place in Earth orbit. The CLL provides a means to automatically lock the longeron sections into position during deployment as well as a means of unlocking the sections when the antenna is to be restowed. The CLL is a four bar linkage mechanism using the over center principle for locking. It utilizes the relative movement of the longeron sections to activate the mechanism during antenna deployment and restowing. The CLL design is one of the first mechanisms developed to meet the restowing requirements of spacecraft which will utilize the STS retrieval capability.

Ahl, E. L., Jr.↗

Radial dependence of HF wave field strength in the BPD column

The results of a recent set of RF frequency measurements of the beam plasma discharge (BPD) performed in order to determine a quantitative value for the field strength in the plasma frequency region of the spectrum are presented. The parallel and perpendicular components of the plasma wave electric fields inside the BPD column have comparable field strengths, on the order of 10 volts/m. The radial dependence of the field strength is very strong, decreasing by as much as 40 dB within one meter from the beam center, with the illumination or discharge column approximately one meter in diameter. The field strength inside the column increases as a function of distance along the beam at least for several meters from the gun aperture. The frequency and amplitude of the plasma wave increases with beam current. A particularly rapid increase in these parameters occurs as the beam current approaches the critical current.

Jost, R. J.↗

Direct coupling of microbore HPLC columns to MS systems

A detailed investigation using electron microscopy was conducted which examined the conditions of materials used in the construction of stable, high performance microbore liquid chromatography (LC) columns. Small details proved to be important. The effects of temperature on the elution of several homologous series used as probe compounds was examined in reverse phase systems. They showed that accessible temperature changes provide roughly half the increase in solvent strength that would be obtained going from a 100% aqueous to a 100% organic mobile phase, which is sufficient to warrant their use in many analyses requiring the use of gradients. Air circulation temperature control systems provide the easiest means of obtaining rapid, wide range changes in column temperature. However, slow heat transfer from the gas leads to thermal nonuniformity in the column and a decrease in resolution as the temperature program progresses.

Mcnair, H. M.↗

Atmospheric contributions to the column variance in direct-detection dial

One of the most important parameters of a Differential Absorption Lidar (DIAL) system is the delay time between the on and off resonant pulses. It is important that this delay time is sufficiently small to ensure that the atmosphere is effectively frozen between the pulses. Therefore, most Dial systems were designed with two lasers firing alternately less than 1 msec apart. Despite the importance of this parameter in the design of DIAL systems and its contribution to the overall error of a column measurement, very little is known about the size of the error for the case of a direct-detection system using atmospheric backscatter. The ultraviolet DIAL system uses two independent YAG/dye lasers and is therefore suitable for measuring the effects of different pulse delays on the variance of column measurements for a variety of atmospheric conditions. A set of DIAL returns were acquired with the two lasers tuned to the same wavelength and with a range of pulse delay times between 250 microseconds and several minutes. This data set was recorded in full on a computer and was used both to test different averaging techniques and also to evaluate atmospheric contributions to DIAL columns.

Milton, M. J. T.↗

Galactic interstellar abundance surveys with IUE. II - The equivalent widths and column densities

This paper continues a survey of interstellar densities, abundances, and cloud structure in the Galaxy, using the International Ultraviolet Explorer (IUE) satellite. Equivalent widths of 18 ultraviolet resonance transitions are presented and column densities for Si II, Mn II, Fe II, S II, and Zn II toward 261 early-type stars are derived. These equivalent widths and column densities agree within the stated errors of earlier Copernicus, BUSS, or IUE surveys of Mn II, Fe II, S II, and Zn II for 45 stars in common. The column densities are derived from single-component curves of growth with a common b-value based on that of Fe II and Si II.

Van Steenberg, Michael E.↗

Stratospheric column NO2 measurements from three Antarctic sites

The significance of stratospheric odd-nitrogen compounds in Antarctic ozone depletion studies has prompted an increase in Antarctic activities. Although several species are being studied, work has concentrated on the acquisition of NO2 data. Ground-based measurements of stratospheric column NO2 have been made at Arrival Heights, Antarctica, since spring 1982, with some gaps in the data base. Additional data has been acquired since February 1986 at Pole Station and Halley Bay, thus providing a chain of stations across the continent. The technique used is that of absorption spectroscopy in several wavelength regions, although here only those measurements are reported in the 430 to 450 nm region where strongly structured absorption been determined experimentally. However, theory features due to NO2 are identified in scattered sunlight in the zenith sky. Operation of a moon-tracking system at Arrival Heights has provided some additional data during the polar night. Previous analyses have shown that the NO2 column observed from the ground is strongly influenced by the season, and by the location of the site with respect to that of the polar vortex. The column amount correlates strongly with stratospheric temperature at about 70 mbar. The present data set further illustrates these features, and demonstrates both the strengths and qualifications apparent in the technique.

Keys, J. G.↗

Growth of single-crystal columns of CoSi2 embedded in epitaxial Si on Si(111) by molecular beam epitaxy

The codeposition of Si and Co on a heated Si(111) substrate is found to result in epitaxial columns of CoSi2 if the Si:Co ratio is greater than approximately 3:1. These columns are surrounded by an Si matrix which shows bulk-like crystalline quality based on transmission electron microscopy and ion channeling. This phenomenon has been studied as functions of substrate temperature and Si:Co ratio. Samples with columns ranging in average diameter from approximately 25 to 130 nm have been produced.

Fathauer, R. W.↗

Secular increase of the total vertical column abundance of carbon monoxide above central Europe since 1950

The secular increase of the total vertical column abundance of carbon monoxide has been derived from sets of infrared solar spectra recorded from an altitude of 3.58 km at the Jungfraujoch Station, Switzerland, in 1950-1951 and in 1985-1987. The results are based on equivalent width measurements of the R3 line of the 1-0 vibration-rotation band of (C-12)(0-16) at 2159.30/cm. The set of 1985-1987 observations indicates a strong seasonal cycle in the total column abundance of CO, with a + or - 25 percent modulation between minimum values in late summer and the maximum values in late winter. Variability on shorter time scales is also present in both the old and recent data sets. The mean cumulative rate of increase of the total column abundance of CO above the Jungfraujoch is found to be (0.85 + or - 0.20) percent/yr between 1950-1951 and 1985-1987. The present findings are compared with trends reported in earlier studies.

Zander, R.↗

Thermocapillary flow and natural convection in a melt column with an unknown melt/solid interface

A vertical melt column set up between an upper heating rod and a lower sample rod, i.e., the so-called half-zone system, is a convenient experimental tool for studying convection in the melt in floating-zone crystal growth. In order to help understand the convection observed in the melt column, a computer model has been developed to describe steady state, axisymmetrical thermocapillary flow and natural convection in the melt. The governing equations and boundary conditions are expressed in general non-orthogonal curvilinear coordinates in order to accurately treat the unknown melt/solid interface as well as all other physical boundaries in the system. The effects of key dimensionless variables on the following items are discussed: (1) convection and temperature distribution in the melt; (2) the shape of the melt/solid interface; (3) the height of the melt column. These dimensionless variables are the Grashof, Marangoni and Prandtl numbers.

Lan, C. W.↗