Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPRESSORS - BLADES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

8- by 6-Foot Supersonic Wind Tunnel Compressor Inspected

The NASA Glenn Research Center's 8- by 6-Foot Supersonic Wind Tunnel (8 6 SWT) is NASA's only transonic propulsion wind tunnel. The test section speed range is between Mach 0.25 and 2.0. The 9- by 15-Foot Low-Speed Wind Tunnel (9 15 LWST), which has a speed range from 0 to 175 mph, is housed in the return leg of the 8 6 SWT and uses the same compressor. The 8 6 SWT uses a large, seven-stage axial flow compressor to drive the air through the tunnel. The compressor is 17 ft in diameter and is rated at 1600 m3 (56,600 ft3) of air/sec. It is driven by three electric motors with a combined horsepower of 87,000. A close examination of this compressor was performed in 2001, the first time since February of 1966.

Krupar, Martin J.↗

Centrifugal Compressor Surge Controlled

It shows the variation in compressor mass flow with time as the mass flow is throttled to drive the compressor into surge. Surge begins where wide variations in mass flow occur. Air injection is then turned on to bring about a recovery from the initial surge condition and stabilize the compressor. The throttle is closed further until surge is again initiated. Air injection is increased to again recover from the surge condition and stabilize the compressor.

Skoch, Gary J.↗

Toward a Real-Time Measurement-Based System for Estimation of Helicopter Engine Degradation Due to Compressor Erosion

This paper presents a preliminary demonstration of an automated health assessment tool, capable of real-time on-board operation using existing engine control hardware. The tool allows operators to discern how rapidly individual turboshaft engines are degrading. As the compressor erodes, performance is lost, and with it the ability to generate power. Thus, such a tool would provide an instant assessment of the engine s fitness to perform a mission, and would help to pinpoint any abnormal wear or performance anomalies before they became serious, thereby decreasing uncertainty and enabling improved maintenance scheduling. The research described in the paper utilized test stand data from a T700-GE-401 turboshaft engine that underwent sand-ingestion testing to scale a model-based compressor efficiency degradation estimation algorithm. This algorithm was then applied to real-time Health Usage and Monitoring System (HUMS) data from a T700-GE-701C to track compressor efficiency on-line. The approach uses an optimal estimator called a Kalman filter. The filter is designed to estimate the compressor efficiency using only data from the engine s sensors as input.

Litt, Jonathan S.↗

Calibration of a V-Cone for Low Mass Flows For Small Core Compressor Research

Advancements in core compressor technologies are necessary for next generation, high Overall Pressure Ratio (OPR) turbofan engines. High pressure compressors (HPCs) for future engines are being designed with exit corrected mass flow rates less than 2.25 kg/s (5 lbm/s). In order to accurately measure the performance of these advanced designs, high accuracy measurements are needed in test facilities. The W7 High Speed Multistage Axial Compressor Facility at NASA Glenn Research Center has been used to acquire data for advanced compressor designs. This facility utilizes an advanced differential pressure flow meter called a V-Cone. The facility has historically tested components with physical mass flow rates in the range of 27 to 45 kg/s (60 to 100 lbm/s). As such, when the V-Cone was calibrated prior to installation, the calibrations focused on higher mass flow rates, and uncertainties in that regime range from 0.5% to 0.85%. However, for low mass flow rates under 9 kg/s (20 lbm/s), expected in tests of advanced high OPR HPCs rear stages, the uncertainties of the V-Cone exceed 2.5%. To address this, using a method similar to that utilized by the National Institute of Standards and Technology, an array of Critical Flow Venturi Nozzles (CFVs) was installed in the W7 test section and used to calibrate the V-Cone in 0.5 kg/s (1 lbm/s) increments up to 10.5 kg/s (23 lbm/s). This effort details the measurements and uncertainties associated with this calibration which resulted in a final uncertainty of the V-Cone measurements under 1%.

Measurement Uncertainty↗

Evaluation of centrifugal compressor performance with water injection

The effects of water injection on a compressor are presented. To determine the effects of varying water-air ratio, the compressor was operated at a constant equivalent impeller speed over a range of water-air ratios and weight flows. Operation over a range of weight flows at one water-air ratio and two inlet air temperatures was carried out to obtain an indication of the effects of varying inlet air temperature. Beyond a water-air ratio of 0.03 there was no increase in maximum air-weight flow, a negligible rise in peak total-pressure ratio, and a decrease in peak adiabatic efficiency. An increase in inlet air temperature resulted in an increase in the magnitude of evaporation. An analysis of data indicated that the magnitude of evaporation within the compressor impeller was small.

COMPRESSORS - RADIAL FLOW↗

Experimental Results of the First Two Stages of an Advanced Transonic Core Compressor Under Isolated and Multi-Stage Conditions

NASA's Environmentally Responsible Aviation (ERA) Program calls for investigation of the technology barriers associated with improved fuel efficiency of large gas turbine engines. Under ERA the task for a High Pressure Ratio Core Technology program calls for a higher overall pressure ratio of 60 to 70. This mean that the HPC would have to almost double in pressure ratio and keep its high level of efficiency. The challenge is how to match the corrected mass flow rate of the front two supersonic high reaction and high corrected tip speed stages with a total pressure ratio of 3.5. NASA and GE teamed to address this challenge by using the initial geometry of an advanced GE compressor design to meet the requirements of the first 2 stages of the very high pressure ratio core compressor. The rig was configured to run as a 2 stage machine, with Strut and IGV, Rotor 1 and Stator 1 run as independent tests which were then followed by adding the second stage. The goal is to fully understand the stage performances under isolated and multi-stage conditions and fully understand any differences and provide a detailed aerodynamic data set for CFD validation. Full use was made of steady and unsteady measurement methods to isolate fluid dynamics loss source mechanisms due to interaction and endwalls. The paper will present the description of the compressor test article, its predicted performance and operability, and the experimental results for both the single stage and two stage configurations. We focus the detailed measurements on 97 and 100 of design speed at 3 vane setting angles.

turbomachinery↗

Gated compressor, distortionless signal limiter

A distortionless gated compressor for limiting the amplitude of a signal so as not to produce undesired signal levels responsive thereto is disclosed. The gated compressor includes a distortionless multiplier which multiplies an AC signal from a factor defined by a DC control signal. The compressor includes a plurality of channels each responsive to a signal produced in response to the multiplier's output. When the signal supplied to any channel exceeds a prescribed level, the level of the DC control signal is reduced to reduce the multiplier's output level and thereby prevent the signal applied to any channel from exceeding its prescribed level.

Woodbury, R. C.↗

Effect of screen-induced total-pressure distortion on axial-flow compressor stability

An experimental investigation was made to determine the effects of screen-induced total-pressure distortions on two J85-GE-13 turbojet engines. Results were compared to those from a previous program run with a third engine. All compressors were found to be sensitive to a critical angle of circumferential distortion equal to 60 deg., and they all adhered closely to the parallel compressor model. The sensitivity of compressor exit pressure to virtually any type of distortion pattern can be determined by defining stall lines for undistorted, hub radial distorted, and tip radial distorted inflows. The effect of multiple sectors of circumferential distortion is defined.

Calogeras, J. E.↗

A compressor designed for the energy research and development agency automotive gas turbine program

A centrifugal compressor was designed for a gas turbine powered automobile as part of the Energy Research and Development Agency program to demonstrate emissions characteristics that meet 1978 standards with fuel economy and acceleration which are competitive with conventionally powered vehicles. A backswept impeller was designed for the compressor in order to attain the efficiency goal range required for the objectives of this program. Details of the design and method of flow analysis of the compressor are presented.

Galvas, M. R.↗

Modeling and analysis of the TF30-P-3 compressor system with inlet pressure distortion

Circumferential inlet distortion testing of a TF30-P-3 afterburning turbofan engine was conducted at NASA-Lewis Research Center. Pratt and Whitney Aircraft analyzed the data using its multiple segment parallel compressor model and classical compressor theory. Distortion attenuation analysis resulted in a detailed flow field calculation with good agreement between multiple segment model predictions and the test data. Sensitivity of the engine stall line to circumferential inlet distortion was calculated on the basis of parallel compressor theory to be more severe than indicated by the data. However, the calculated stall site location was in agreement with high response instrumentation measurements.

Mazzawy, R. S.↗

Analytical prediction of the performance and stability of a J85-13 compressor with distorted inlet flow

The parallel compressor concept was studied using a compressor model based on the overall clean-inlet performance map obtained from experimental tests in an altitude chamber using a General Electric J85-13 turbojet engine. The model, which includes a static-pressure balance calculation at compressor discharge, was exercised at conditions corresponding to 10 different screen-induced distortion patterns included in the experimental data base. The spoiled area of these patterns ranged from 30 deg to 180 deg, and the distortion screen density, or the area blocked by the screen wire per unit area of screen, varied from 26 to 69 percent. The study indicates that at the higher corrected speeds, the analytical surge lines obtained are good representations of the corresponding experimental surge lines and are independent of distortion angle or distortion angle or distortion level.

Milner, E. J.↗

Analysis and identification of subsynchronous vibration for a high pressure parallel flow centrifugal compressor

The summary of a complete analytical design evaluation of an existing parallel flow compressor is presented and a field vibration problem that manifested itself as a subsynchronous vibration that tracked at approximately 2/3 of compressor speed is reviewed. The comparison of predicted and observed peak response speeds, frequency spectrum content, and the performance of the bearing-seal systems are presented as the events of the field problem are reviewed. Conclusions and recommendations are made as to the degree of accuracy of the analytical techniques used to evaluate the compressor design.

Kirk, R. G.↗

Time resolved measurements in a low aspect ratio transonic compressor stage

The time resolved flowfield in a low aspect ratio transonic compressor stage has been studied using a high frequency response sphere probe with a bandpass of D.C. to 20 kHz in a blowdown compressor facility. Averaged over the compressor annulus, the data agree well with those measured with standard pitot type probes on the same stage in a conventional test rig. Not all the spanwise distributions agree, however. These differences are explained as errors in the pitot probe readings due to fluctuations in the flow. The experimental data are compared to the results of a three-dimensional inviscid Euler calculation.

Epstein, A. H.↗

Energy efficient engine low-pressure compressor component test hardware detailed design report

The aerodynamic and mechanical design description of the low pressure compressor component of the Energy Efficient Engine were used. The component was designed to meet the requirements of the Flight Propulsion System while maintaining a low cost approach in providing a low pressure compressor design for the Integrated Core/Low Spool test required in the Energy Efficient Engine Program. The resulting low pressure compressor component design meets or exceeds all design goals with the exception of surge margin. In addition, the expense of hardware fabrication for the Integrated Core/Low Spool test has been minimized through the use of existing minor part hardware.

Michael, C. J.↗

Scaled centrifugal compressor, collector and running gear program

The Scaled Centrifugal Compressor, Collector and Running gear Program was conducted in support of an overall NASA strategy to improve small-compressor performance, durability, and reliability while reducing initial and life-cycle costs. Accordingly, Garrett designed and provided a test rig, gearbox coupling, and facility collector for a new NASA facility, and provided a scaled model of an existing, high-performance impeller for evaluation scaling effects on aerodynamic performance and for obtaining other performance data. Test-rig shafting was designed to operate smoothly throughout a speed range up to 60,000 rpm. Pressurized components were designed to operate at pressures up to 300 psia and at temperatures to 1000 F. Nonrotating components were designed to provide a margin-of-safety of 0.05 or greater; rotating components, for a margin-of-safety based on allowable yield and ultimate strengths. Design activities were supported by complete design analysis, and the finished hardware was subjected to check-runs to confirm proper operation. The test rig will support a wide range of compressor tests and evaluations.

Kenehan, J. G.↗

Development of controlled diffusion airfoils for multistage compressor application

A series of Controlled Diffusion Airfoils has been developed for multistage compressor application. These airfoils are designed analytically to be shock free at transonic Mach number and to avoid suction surface boundary layer separation for a range of inlet conditions necessary for stable compressor operation. They have demonstrated, in cascade testing, higher critical Mach number, higher incidence range, and higher loading capability than standard series airfoils designed for equivalent aerodynamic requirements. These airfoils have been shown, in single and multistage rig testing, to provide high efficiency, high loading capability, and ease of stage matching, leading to reduced development costs and improved surge margin. The Controlled Diffusion Airfoil profile shapes tend to have thicker leading and trailing edges than their standard series counterparts, leading to improved compressor durability.

Hobbs, D. E.↗

Loss reduction in axial-flow compressors through low-speed model testing

A systematic procedure for reducing losses in axial-flow compressors is presented. In this procedure, a large, low-speed, aerodynamic model of a high-speed core compressor is designed and fabricated based on aerodynamic similarity principles. This model is then tested at low speed where high-loss regions associated with three-dimensional endwall boundary layers flow separation, leakage, and secondary flows can be located, detailed measurements made, and loss mechanisms determined with much greater accuracy and much lower cost and risk than is possible in small, high-speed compressors. Design modifications are made by using custom-tailored airfoils and vector diagrams, airfoil endbends, and modified wall geometries in the high-loss regions. The design improvements resulting in reduced loss or increased stall margin are then scaled to high speed. This paper describes the procedure and presents experimental results to show that in some cases endwall loss has been reduced by as much as 10 percent, flow separation has been reduced or eliminated, and stall margin has been substantially improved by using these techniques.

Wisler, D. C.↗

Axial-Flow Compressor Performance With Water Ingestion

Stage-stacking computer code (WISGSK) developed for prediction of offdesign axial-flow compressor performance with water ingestion. Code uses meantime stage-stacking method; stage and cumulative compressor performance calculated utilizing representative triangles located at rotor inlet and outlet mean radii. Code provides options for calculation of performance with mixtures of gases such as air and water vapor and air/water droplet mixtures with different water contents. Useful for obtaining preliminary estimates of overall performance of compressors with water ingestion given design point details corresponding to airflow and nature of corrections for air/water mixture flow.

Tsuchiya, T.↗