Estimation using sampled-data containing sequentially correlated noise.
Multistage linear dynamic systems with sequentially correlated noise, evaluating filtering, prediction and smoothing procedures
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Multistage linear dynamic systems with sequentially correlated noise, evaluating filtering, prediction and smoothing procedures
An experimental study was performed to measure biogas production from sugar beet waste, which is, in fact, the chopped parts of the sugar beet not going through the sugar extraction process, at different additive concentrations. Medium molecular weight chitosan in microsize and TiO{sub 2} and Fe{sub 3}O{sub 4} nanoparticles were added to ten experimental reactors to investigate their effect on the anaerobic digestion process. Three different concentrations of 0.01, 0.04, and 0.12% w/w were used for each additive. Biogas production and methane content were compared with a control sample containing no additive. Adding chitosan in powder form did not help the process nor improved methanogenic activities. The results showed no effect on anaerobic digestion by the addition of TiO{sub 2} nanoparticles in the mentioned concentrations, whereas adding Fe{sub 3}O{sub 4} nanoparticles led to a slight increase in methane production and in volatile solid and total solid reduction. The maximum enhancement in methane and biogas production in the sample containing 0.04% Fe{sub 3}O{sub 4}, as compared with the control sample, reached 19.77% and 15.09%, respectively.
Purpose: Noble metal nanoparticles have found several medical applications in the areas of radiation detection; x-ray contrast agents and cancer radiation therapy. Based on computational methods, many papers have reported the nanoparticle effect on the dose deposition in the surrounding medium. Here the authors report experimental results on how silver and gold nanoparticles affect the dose deposition in alanine dosimeters containing several concentrations of silver and gold nanoparticles, for five different beam energies, using electron spin resonance spectroscopy (ESR). Methods: The authors produced alanine dosimeters containing several mass percentage of silver and gold nanoparticles. Nanoparticle sizes were measured by dynamic light scattering and by transmission electron microscopy. The authors determined the dose enhancement factor (DEF) theoretically, using a widely accepted method, and experimentally, using ESR spectroscopy. Results: The DEF is governed by nanoparticle concentration, size, and position in the alanine matrix. Samples containing gold nanoparticles afford a DEF higher than 1.0, because gold nanoparticle size is homogeneous for all gold concentrations utilized. For samples containing silver particles, the silver mass percentage governs the nanoparticles size, which, in turns, modifies nanoparticle position in the alanine dosimeters. In this sense, DEF decreases for dosimeters containing large and segregated particles. The influence of nanoparticle size-position is more noticeable for dosimeters irradiated with higher beam energies, and dosimeters containing large and segregated particles become less sensitive than pure alanine (DEF < 1). Conclusions: ESR dosimetry gives the DEF in a medium containing metal nanoparticles, although particle concentration, size, and position are closely related in the system. Because this is also the case as in many real systems of materials containing inorganic nanoparticles, ESR is a valuable tool for investigating DEF. Moreover, these results alert to the importance of controlling the size-position of nanoparticles to enhance DEF.
Returning lunar samples to earth is a high priority for NASA in order to better understand Lunar Geology, Lunar formation, and potential resource utilization. Core samples of frozen volatiles from permanently shadowed regions are sought after, but require intensive cryogenic cooling to preserve. Returning samples to Earth using the Orion capsule is restrictive for moderate amounts of mass/volume and thus alternate means of transport are investigated in this paper. The trade-space of potential options includes varying: sample mass amount, sample containment conditions, transfer path from Lunar surface to Earth surface, and various vehicle system trades. An integrated solver is applied with parametric estimators and known system heuristics to effectively estimate size, mass, and power of various subsystems. Modeled subsystems include sample containment, EDL technologies(heat shield, parachute, recovery), power, thermal, avionics, structures, and propulsive systems. Transfer path options include various trajectory options, transfer methods, staging points, and vehicle staging options. A Design of Experiments was conducted to explore the tradespace, to identify sensitivities, and to identify promising designs. Results are detailed for various stakeholder objectives including total mass, sample mass, science return, architecture impacts, and operational flexibility.
Abstract We present the Multi‐site (MS) QuantEXAFS approach, designed to model the EXAFS data from samples containing an element in different local bonding geometries. Building upon our QuantEXAFS method, which maps experimental extended X‐ray absorption fine structures (EXAFS) data to DFT‐optimized structures, MS‐QuantEXAFS introduces the key capability to probe fractional contributions of multiple sites that may be present in an experimental sample. Specifically, we demonstrate effectiveness of this technique by investigating mixed samples containing known fractions of site‐isolated subsurface Pt/MgO with Pt nanoparticles uniformly supported on MgO. The ‘site‐fractions’ obtained through MS‐QuantEXAFS closely match (i. e., ±6%) the known fractions of the physically mixed samples. This approach has been generalized to other oxides, and thus represents an important advance in quantifying the speciation of non‐uniform catalyst samples.
Four options for return of a Mars surface sample to Earth were studied to estimate the risk of mission failure and the risk of a sample container breach that might result in the release of Martian life forms, should such exist, in the Earth's biosphere. The probabilities calculated refer only to the time period from the last midcourse correction burn to possession of the sample on Earth. Two extreme views characterize this subject. In one view, there is no life on Mars, therefore there is no significant risk and no serious effort is required to deal with back contamination. In the other view, public safety overrides any desire to return Martian samples, and any risk of damaging contamination greater than zero is unacceptable. Zero risk requires great expense to achieve and may prevent the mission as currently envisioned from taking place. The major conclusion is that risk of sample container breach can be reduced to a very low number within the framework of the mission as now envisioned, but significant expense and effort, above that currently planned is needed. There are benefits to the public that warrant some risk. Martian life, if it exists, will be a major discovery. If it does not, there is no risk.
90 Sr is one of the isotopes most commonly produced by nuclear fission. This medium lived isotope presents serious challenges to radiation workers, the environment, and following a nuclear event, the general public. Methods of identifying this nuclide have been in existence for a number of years (e.g. Horwitz, E.P. [1], Maxwell, S.L.[2], EPA 905.0 [3]) which are time consuming, requiring a month or more for full analysis. This time frame is unacceptable in the present security environment. It is therefore important to have a dependable and rapid method for the determination of Sr. The purposes of this study are to reduce analysis time to less than half a day by utilizing a single method of radiation measurement while continuing to yield precise results. This paper presents findings on three methods that can meet this criteria; (1) stable Sr carrier, (2) 85 Sr by gamma spectroscopy, and (3) 85 Sr by LSC. Two methods of analyzing and calculating the 85 Sr tracer recovery were investigated (gamma spectroscopy and a low energy window-Sr85LEBAB by LSC) as well as the use of two different types of Sr tracer ( 85 Sr and stable Sr carrier). Three separate stock blank urine samples were spiked with various activity levels of 239 Pu, 137 Cs, 90 Sr / 90 Y to determine the effectiveness of the Eichrome Sr-spec™ resin 2mL extractive columns. The objective was to compare the recoveries of 85 Sr versus a stable strontium carrier, attempt to compare the rate at which samples can be processed by evaluating evaporation, neutralization, and removing the use of another instrument (gamma spectrometer) by using the LSC spectrometer to obtain 85 Sr recovery. It was found that when using a calibration curve comprised of a different cocktail and a non-optimum discriminator setting reasonable results (bias of ± 25%) were achieved. The results from spiked samples containing 85 Sr demonstrated that a higher recovery is obtained when using gamma spectroscopy (89-95%) than when using the LEB window from LSC (120-470%). The high recovery for 85 Sr by LSC analysis may be due to the interference/cross talk from the alpha region since alpha counts were observed in all sample sets. After further investigation it was determined that the alpha counts were due to 239 Pu breakthrough on the Sr-spec™ column. This requires further development to purify the Sr before an accurate tracer recovery determination can be made. Sample preparation times varied and ranged from 4-6 hours depending on the specific sample preparation process. The results from the spiked samples containing stable strontium nitrate Sr(NO 3 ) 2 carrier demonstrate that gravimetric analysis yields the most consistent high recoveries (97-101%) when evaporation is carefully performed. Since this method did not have a variation on the tracer recovery method, the samples were counted in 1) LEB/Alpha/Beta mode optimized for Sr-90, 2) DPM for Sr-90, and 3) general LEB/Alpha/Beta mode. The results (from the known) ranged from 79-104%, 107-177%, and 85-89% for 1, 2, and 3 respectively. Counting the prepared samples in a generic low energy beta/alpha/beta protocol yielded more accurate and consistent results and also yielded the shortest sample preparation turn-around-time of 3.5 hours.
A new apparatus has been developed for microtomography studies under high pressure. The pressure generation mechanism is based on the concept of the widely used Drickamer anvil apparatus, with two opposed anvils compressed inside a containment ring. Modifications are made with thin aluminum alloy containment rings to allow transmission of x rays. Pressures up to 8 GPa have been generated with a hydraulic load of 25 T. The modified Drickamer cell is supported by thrust bearings so that the entire pressure cell can be rotated under load. Spatial resolution of the high pressure tomography apparatus has been evaluated using a sample containing vitreous carbon spheres embedded in FeS matrix, with diameters ranging from 0.01 to 0.2 mm. Spheres with diameters as small as 0.02 mm were well resolved, with measured surface-to-volume ratios approaching theoretical values. The sample was then subject to a large shear strain field by twisting the top and bottom Drickamer anvils. Imaging analysis showed that detailed microstructure evolution information can be obtained at various steps of the shear deformation, allowing strain partition determination between the matrix and the inclusions. A sample containing a vitreous Mg{sub 2}SiO{sub 4} sphere in FeS matrix was compressed to 5 GPa, in order to evaluate the feasibility of volume measurement by microtomography. The results demonstrated that quantitative inclusion volume information can be obtained, permitting in situ determination of P-V-T equation of state for noncrystalline materials.
Technetium (Tc), which exists predominately in the liquid supernatant and salt cake fractions of the nuclear tank waste stored at the U.S. DOE Hanford Site, is one of the most difficult contaminants to dispose of and/or remediate. In the strongly alkaline environments prevalent in the tank waste, its dominant chemical form is pertechnetate (TcO 4 - , oxidation state +7). However, based on experimentation to-date, a significant fraction of the soluble Tc cannot be effectively separated from the wastes and may be present as a non-pertechnetate species. The presence of a non pertechnetate species significantly complicates disposition of low-activity waste (LAW), and the development of methods to either convert them to pertechnetate or to separate the non-pertechnetate species directly is needed. The challenge is the uncertainty regarding the nature and stability of the alkaline-soluble, low-valence, non pertechnetate species in the liquid tank waste. One objective of the Tc management project is to address this knowledge gap. This fiscal year (FY) 2015 report summarizes experimental work exploring the oxidative stability of model low-valence Tc(I) tricarbonyl species, derived from the [Tc(CO) 3 ] + moiety. These compounds are of interest due to their implied presence in several Hanford tank waste supernatants. Work in part was initiated in FY 2014, and a series of samples containing non-pertechnetate Tc generated ex situ or in situ in pseudo-Hanford tank supernatant simulant solutions was prepared and monitored for oxidation to Tc(VII) (Levitskaia et al. 2014). This experimentation continued in FY 2015, and new series of samples containing Tc(I) as [Tc(CO) 3 ] + •Ligand was tested. The monitoring method used for these studies was a combination of 99 Tc NMR and EPR spectroscopies.
A method and apparatus are provided for acoustophoresis, i.e., the separation of species via acoustic waves. An ultrasonic transducer applies an acoustic wave to one end of a sample container containing at least two species having different acoustic absorptions. The wave has a frequency tuned to or harmonized with the point of resonance of the species to be separated. This wave caused the species to be driven to an opposite end of the sample container for removal. A second ultrasonic transducer may be provided to apply a second, oppositely directed acoustic wave to prevent undesired streaming. In addition, a radio frequency tuned to the mechanical resonance and coupled with a magnetic field can serve to identify a species in a medium comprising species with similar absorption coefficients, whereby an acoustic wave having a frequency corresponding to this gyrational rate can then be applied to sweep the identified species to one end of the container for removal.
A method and apparatus are provided for acoustophoresis, i.e., the separation of species via acoustic waves. An ultrasonic transducer applies an acoustic wave to one end of a sample container containing at least two species having different acoustic absorptions. The wave has a frequency tuned to or harmonized with the point of resonance of the species to be separated. This wave causes the species to be driven to an opposite end of the sample container for removal. A second ultrasonic transducer may be provided to apply a second, oppositely directed acoustic wave to prevent undesired streaming. In addition, a radio frequency tuned to the mechanical resonance and coupled with a magnetic field can serve to identify a species in a medium comprising species with similar absorption coefficients, whereby an acoustic wave having a frequency corresponding to this gyrational rate can then be applied to sweep the identified species to one end of the container for removal.
The roles of barium oxide and platinum during the sulfation of Pt-BaO/Al2O3 lean NOx trap catalysts were investigated by S K edge XANES (X-ray absorption near-edge spectroscopy) and Pt LIII XAFS (X-ray absorption fine structure). All of the samples studied (Al2O3, BaO/Al2O3, Pt/Al2O3 and Pt-BaO/Al2O3) were pre-sulfated prior to the X-ray absorption measurements. It was found that barium oxide itself has the ability to directly form barium sulfate even in the absence of Pt and gas phase oxygen. In the platinum-containing samples, the presence of Pt-O species plays an important role in the formation of sulfate species. Even if barium and aluminum sites are available for SO2 to form sulfate, for the case of the BaO(8)/Al2O3 sample, where the barium coverage is about 0.26 ML, S XANES spectroscopy results show that barium sulfates are preferentially produced over aluminum sulfates . When oxygen is absent from the gas phase, the sulfation route that involves Pt-O is eliminated after the initially present Pt-O species are completely consumed. In this case, formation of sulfates is suppressed unless barium oxide is also present. Pt LIII XAFS results show that the first coordination sphere around the Pt atoms in the Pt particles is dependent upon the redox nature of the gas mixture used during the sulfation process. Sulfation under reducing environments (e.g. SO2+H2) leads to formation of Pt-S bonds, while oxidizing conditions (e.g. SO2+O2) continue to show the presence of Pt-O bonds. In addition, the former condition was found to give rise to a higher degree of Pt sintering than the latter one. This result explains why samples sulfated under reducing conditions had lower NOx uptakes than those sulfated under oxidizing conditions. Therefore, our results provide needed information for the development of optimum practical operation conditions (e.g. sulfation or desulfation) for lean NOx trap catalysts that minimize deactivation by sulfur.
Polycrystalline samples of Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16}, y{<=}0.3 were prepared by solid-state synthesis and characterized to determine their optical properties, thermoelectric properties and electrical impedance. Using diffuse reflectance data and assuming a direct band gap, the band gap of the material ranges from 3.58 eV for y=0 to 3.74 eV for y=0.2. The dc conductivity decreased with increasing Ti content and was thermally activated, ranging from {<=}10{sup -5} S/cm at 300 Degree-Sign C to 0.03 S/cm at 1000 Degree-Sign C for Ga{sub 3}InSn{sub 5}O{sub 16}. The Seebeck coefficient was negative indicating n-type conduction. The activation energies for dc conduction and thermopower were similar, ranging from 1.4{+-}0.1 eV for y=0 to 1.8{+-}0.2 eV for y=0.2, suggesting band conduction. The thermal conductivity of Ga{sub 3}InSn{sub 5}O{sub 16} ranged from 1.1 W/m K at 500 {sup o}C to 0.75 W/m K at 800 Degree-Sign C. The highest figure of merit measured was 2 Multiplication-Sign 10{sup -4} at {approx}900 Degree-Sign C, which is much lower than desired for thermoelectric materials. A comparison of dc conductivity and impedance data indicated a substantial ionic contribution for samples containing titanium. - Graphical abstract: The thermoelectric properties of polycrystalline Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16}, y{<=}0.3 were measured in air at 300-900 Degree-Sign C. The materials are broad-band n-type semiconductors with non-negligible ionic conduction for samples prepared with y>0. The thermoelectric figure of merit is much lower than desired for practical thermoelectric devices. Highlights: Black-Right-Pointing-Pointer Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16}, y{<=}0.2 is a broad-band n-type semiconductor. Black-Right-Pointing-Pointer The conductivity of Ti-containing samples show evidence of an ionic as well as an electronic contribution. Black-Right-Pointing-Pointer The thermal conductivity of polycrystalline Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16} decreases with increasing temperature. Black-Right-Pointing-Pointer The thermoelectric figure of merit for Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16} is lower than desired for practical thermoelectric devices.
The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature of the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.
The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature of the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.
This is the year end report that is due to the client. The MRVL system is designed to measure multiple radioxenon isotopes ( 135 Xe, 133 Xe, 133 mXe and 133 mXe) simultaneously. The system has 12 channels to load samples and make nuclear measurements. Although the MRVL system has demonstrated excellent stability in measurements of Xe-133 and Xe-135 over the year of evaluation prior to delivery, there has been concern about system stability over measurements performed on samples with orders of magnitude different radioactivity, and samples containing multiple isotopes. To address these concerns, a series of evaluation test have been performed at the end-user laboratory. The evaluation was performed in two separate phases. Phase 1 made measurements on isotopically pure Xe-133 from high radioactivity down to the system background levels of activity, addressing the potential count rate dependencies when activities change from extreme high to very low. The second phase performed measurements on samples containing multiple isotopes (Xe-135, Xe-133 and Xe-133m), and addressed concerns about the dependence of isotopic concentrations on the presence of additional isotopes. The MRVL showed a concentration dependence on the Xe-133 due to the amount of Xe-133m that was in the sample. The dependency is due to the decay of Xe-133m into Xe-133. This document focuses on the second phase and will address the analysis used to account for ingrowth of Xe-133 from Xe-133m.
Single-phase Zn{sub 4}Sb{sub 3} and ZnSb-containing samples were prepared by Plasma Activated Sintering. An abrupt decrease of thermal conductivity was found at about 400 K, which is attributed to the microstructure change of Zn{sub 4}Sb{sub 3}. Nanoscale inclusions and compositional inhomogeneities were found in Zn{sub 4}Sb{sub 3} sample at 473 K by high-resolution transmission electron microscopy. The phonon scattering is enhanced by increasing grain boundaries and chaotic structure, which reduces the thermal conductivity and increases the thermoelectric performance of Zn{sub 4}Sb{sub 3} at elevated temperature. The Rietveld refinement results show that large ZnSb grains in ZnSb-containing samples will accommodate excess Zn atoms, and then reduce thermoelectric performance.
An exothermic furnace module is disclosed for processing materials in space which includes an insulated casing and a sample support, carried within the casing which supports a sample container. An exothermic heat source includes a plurality of segments of exothermic material stacked one upon another to produce a desired temperature profile when ignited. The exothermic material segments are constructed in the form of an annular element having a recess opening which defines an open central core throughout the vertical axis of the stacked exothermic material. The sample container is arranged within the core of the stacked exothermic heating material.