Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTINUOUS FLOW SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Ground System for Solar Dynamics Observatory (SDO) Mission

NASA s Goddard Space Flight Center (GSFC) has recently completed its Critical Design Review (CDR) of a new dual Ka and S-band ground system for the Solar Dynamics Observatory (SDO) Mission. SDO, the flagship mission under the new Living with a Star Program Office, is one of GSFC s most recent large-scale in-house missions. The observatory is scheduled for launch in August 2008 from the Kennedy Space Center aboard an Atlas-5 expendable launch vehicle. Unique to this mission is an extremely challenging science data capture requirement. The mission is required to capture 99.99% of available science over 95% of all observation opportunities. Due to the continuous, high volume (150 Mbps) science data rate, no on-board storage of science data will be implemented on this mission. With the observatory placed in a geo-synchronous orbit at 36,000 kilometers within view of dedicated ground stations, the ground system will in effect implement a "real-time" science data pipeline with appropriate data accounting, data storage, data distribution, data recovery, and automated system failure detection and correction to keep the science data flowing continuously to three separate Science Operations Centers (SOCs). Data storage rates of approx. 45 Tera-bytes per month are expected. The Mission Operations Center (MOC) will be based at GSFC and is designed to be highly automated. Three SOCs will share in the observatory operations, each operating their own instrument. Remote operations of a multi-antenna ground station in White Sands, New Mexico from the MOC is part of the design baseline.

Tann, Hun K.↗

Controlling Flows Of Two Ingredients For Spraying

Closed-loop servo control subsystem incorporated, as modification, into system controlling flows of two ingredients mixed and sprayed to form thermally insulating foams on large tanks. Provides steady flows at specified rates. Foams produced smoother and of higher quality. Continued use of system results in substantial reduction in cost stemming from close control of application of foam and consequent reduced use of material.

Chandler, Huel H.↗

One Dimensional Analysis Model of a Condensing Spray Chamber Including Rocket Exhaust Using SINDA/FLUINT and CEA

Modeling droplet condensation via CFD codes can be very tedious, time consuming, and inaccurate. CFD codes may be tedious and time consuming in terms of using Lagrangian particle tracking approaches or particle sizing bins. Also since many codes ignore conduction through the droplet and or the degradating effect of heat and mass transfer if noncondensible species are present, the solutions may be inaccurate. The modeling of a condensing spray chamber where the significant size of the water droplets and the time and distance these droplets take to fall, can make the effect of droplet conduction a physical factor that needs to be considered in the model. Furthermore the presence of even a relatively small amount of noncondensible has been shown to reduce the amount of condensation. It is desirable then to create a modeling tool that addresses these issues. The path taken to create such a tool is illustrated. The application of this tool and subsequent results are based on the spray chamber in the Spacecraft Propulsion Research Facility (B2) located at NASA's Plum Brook Station that tested an RL-10 engine. The platform upon which the condensation physics is modeled is SINDAFLUINT. The use of SINDAFLUINT enables the ability to model various aspects of the entire testing facility, including the rocket exhaust duct flow and heat transfer to the exhaust duct wall. The ejector pumping system of the spray chamber is also easily implemented via SINDAFLUINT. The goal is to create a transient one dimensional flow and heat transfer model beginning at the rocket, continuing through the condensing spray chamber, and finally ending with the ejector pumping system. However the model of the condensing spray chamber may be run independently of the rocket and ejector systems detail, with only appropriate mass flow boundary conditions placed at the entrance and exit of the condensing spray chamber model. The model of the condensing spray chamber takes into account droplet conduction as well as the degrading effect of mass and heat transfer due to the presence of noncondensibles. The one dimension model of the condensing spray chamber makes no presupposition on the pressure profile within the chamber, allowing the implemented droplet physics of heat and mass transfer coupled to the SINDAFLUINT solver to determine a transient pressure profile of the condensing spray chamber. Model results compare well to the RL-10 engine pressure test data.

Chemical Equilibrium↗

One Dimensional Analysis Model of a Condensing Spray Chamber Including Rocket Exhaust Using SINDA/FLUINT and CEA

Modeling droplet condensation via CFD codes can be very tedious, time consuming, and inaccurate. CFD codes may be tedious and time consuming in terms of using Lagrangian particle tracking approaches or particle sizing bins. Also since many codes ignore conduction through the droplet and or the degradating effect of heat and mass transfer if noncondensible species are present, the solutions may be inaccurate. The modeling of a condensing spray chamber where the significant size of the water droplets and the time and distance these droplets take to fall, can make the effect of droplet conduction a physical factor that needs to be considered in the model. Furthermore the presence of even a relatively small amount of noncondensible has been shown to reduce the amount of condensation [Ref 1]. It is desirable then to create a modeling tool that addresses these issues. The path taken to create such a tool is illustrated. The application of this tool and subsequent results are based on the spray chamber in the Spacecraft Propulsion Research Facility (B2) located at NASA's Plum Brook Station that tested an RL-10 engine. The platform upon which the condensation physics is modeled is SINDAFLUINT. The use of SINDAFLUINT enables the ability to model various aspects of the entire testing facility, including the rocket exhaust duct flow and heat transfer to the exhaust duct wall. The ejector pumping system of the spray chamber is also easily implemented via SINDAFLUINT. The goal is to create a transient one dimensional flow and heat transfer model beginning at the rocket, continuing through the condensing spray chamber, and finally ending with the ejector pumping system. However the model of the condensing spray chamber may be run independently of the rocket and ejector systems detail, with only appropriate mass flow boundary conditions placed at the entrance and exit of the condensing spray chamber model. The model of the condensing spray chamber takes into account droplet conduction as well as the degrading effect of mass and heat transfer due to the presence of noncondensibles. The one dimension model of the condensing spray chamber makes no presupposition on the pressure profile within the chamber, allowing the implemented droplet physics of heat and mass transfer coupled to the SINDAFLUINT solver to determine a transient pressure profile of the condensing spray chamber. Model results compare well to the RL-10 engine pressure test data.

Condensing Spray Model↗

A theoretical study of the acoustic impedance of orifices in the presence of a steady grazing flow

Oscillatory fluid flow in the vicinity of a circular orifice with a steady grazing flow is analyzed. A simplified system of partial differential equations is obtained by starting with the momentum and continuity equations and by assuming that the flow can be represented as an oscillatory motion superimposed on the (known) steady flow. It is found that the equations are linear in the region where grazing-flow effects dominate; a solution and the resultant orifice impedance are given for this region. It is tentatively concluded that orifice resistance is directly proportional to grazing-flow velocity and that the orifice inductive end correction is not a function of grazing flow.

Rice, E. J.↗

Continuous flow photochemical synthesis of metal–ceramic composite microparticles

We developed a UV-assisted microfluidic system to synthesize FeCrAl–Al 2 O 3 composite microparticles for additive manufacturing. Here, the system ensures precise particle size, morphology, and elemental distribution control. Increasing the dispensing pressure while keeping the oil flow rate constant resulted in larger microparticles. Laser fusing revealed FeCrAl and Al 2 O 3 phases, showing their potential as feedstocks for 3D printed heterogeneous materials such as FeCrAl/Al 2 O 3 bi-phase materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NASA Langley Research Center's Simulation-To-Flight Concept Accomplished through the Integration Laboratories of the Transport Research Facility

The Flight Simulation and Software Branch (FSSB) at NASA Langley Research Center (LaRC) maintains the unique national asset identified as the Transport Research Facility (TRF). The TRF is a group of facilities and integration laboratories utilized to support the LaRC's simulation-to-flight concept. This concept incorporates common software, hardware, and processes for both groundbased flight simulators and LaRC s B-757-200 flying laboratory identified as the Airborne Research Integrated Experiments System (ARIES). These assets provide Government, industry, and academia with an efficient way to develop and test new technology concepts to enhance the capacity, safety, and operational needs of the ever-changing national airspace system. The integration of the TRF enables a smooth continuous flow of the research from simulation to actual flight test.

Martinez, Debbie↗

Continuous-flow electrophoresis: Membrane-associated deviations of buffer pH and conductivity

The deviations in buffer pH and conductivity which occur near the electrode membranes in continuous-flow electrophoresis were studied in the Beckman charged particle electrophoresis system and the Hanning FF-5 preparative electrophoresis instrument. The nature of the membranes separating the electrode compartments from the electrophoresis chamber, the electric field strength, and the flow rate of electrophoresis buffer were all found to influence the formation of the pH and conductivity gradients. Variations in electrode buffer flow rate and the time of electrophoresis were less important. The results obtained supported the hypothesis that a combination of Donnan membrane effects and the differing ionic mobilities in the electrophoresis buffer was responsible for the formation of the gradients. The significance of the results for the design and stable operation of continuous-flow electrophoresis apparatus was discussed.

Smolka, A. J. K.↗

A space-marching method for incompressible Navier-Stokes equations

This paper deals with the development of a space-marching method for incompressible flows. The method solves the continuity and momentum equations as a coupled system at each streamwise station. The character of the system of equations has been changed from elliptic to hyperbolic/parabolic in order to enable the equations to be marched in space. The present method has many advantages compared to the existing parabolic or space-marching methods for incompressible flow: (1) it avoids the solution of Poisson equations, (2) it conserves the mass flow with no additional computation, (3) it does not require the specification of an assumed pressure field when used in the prediction of duct flows. The present method can capture strong secondary velocities and strong transverse pressure gradients. Predictions of the flow through straight and curved ducts are in good agreement with analytical and experimental results.

Pouagare, M.↗

Simulation of Liquid Lithium Divertor Geometry Using SOLPS-ITER

Here, plasma-facing component (PFC) geometries are evaluated for a Fusion Nuclear Science Facility (FNSF) design to find solutions that are compatible with flowing liquid lithium components while satisfying requirements from the perspective of plasma and neutral particle transport. Flowing liquid metal (LM) divertor systems offer important advantages due to continual regeneration of the surface material, but may require modifications from standard optimized tokamak divertor designs. Scrape Off Layer Plasma Simulator for the International Thermonuclear Experimental Reactor (SOLPS-ITER) simulations are used to compare standard vertical target, open, and balanced baffled geometries. It is found that the open geometry offers little control of neutral particles and has narrow operating windows where the divertor fluxes can be lowered to acceptable levels, while maintaining the required upstream density. The addition of neutral baffles allows greater control over the divertor conditions with less impact on the upstream density. The divertor neutral pressure in the baffled geometry is slightly higher than the open divertor, but not as large with a vertical target. A first-pass coupling of the SOLPS solution with sheath and implantation/erosion models to compute the lithium emission shows that the lithium is largely confined to the near-surface region due to the small ionization mean free path and large main ion flow toward the surface. The lithium source was varied by three orders of magnitude. At the highest rate, when the sourced lithium approaches the level of the main ion recycling flux, a high core lithium concentration (~10%) is observed with only moderate power dissipation to affect the divertor plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pump, and earth-testable spacecraft capillary heat transport loop using augmentation pump and check valves

A spacecraft includes heat-generating payload equipment, and a heat transport system with a cold plate thermally coupled to the equipment and a capillary-wick evaporator, for evaporating coolant liquid to cool the equipment. The coolant vapor is coupled to a condenser and in a loop back to the evaporator. A heated coolant reservoir is coupled to the loop for pressure control. If the wick is not wetted, heat transfer will not begin or continue. A pair of check valves are coupled in the loop, and the heater is cycled for augmentation pumping of coolant to and from the reservoir. This augmentation pumping, in conjunction with the check valves, wets the wick. The wick liquid storage capacity allows the augmentation pump to provide continuous pulsed liquid flow to assure continuous vapor transport and a continuously operating heat transport system. The check valves are of the ball type to assure maximum reliability. However, any type of check valve can be used, including designs which are preloaded in the closed position. The check valve may use any ball or poppet material which resists corrosion. For optimum performance during testing on Earth, the ball or poppet would have neutral buoyancy or be configured in a closed position when the heat transport system is not operating. The ball may be porous to allow passage of coolant vapor.

Baker, David↗

Detection of small molecules with a flow immunosensor

We describe the development of an easy-to-use sensor with widespread applications for detecting small molecules. The flow immunosensor can analyze discrete samples in under one minute or continuously monitor a flowing stream for the presence of specific analytes. This detection system is extremely specific, and achieves a level of sensitivity which meets or exceeds the detection limits reported for rival assays. Because the system is also compact, transportable, and automated, it has the potential to impact diverse areas. For example, the flow immunosensor has successfully detected drugs of abuse and explosives, and may well address many of the needs of the environmental community with respect to continuous monitoring for pollutants. Efforts are underway to engineer a portable device in the field.

Kusterbeck, Anne W.↗

Electron temperature anisotropy in the polar wind

The steady state flow of a fully ionized H(+)-O(+)-electron plasma along geomagnetic field lines in the high-latitude topside ionosphere is investigated theoretically, with emphasis on the electron temperature anisotropy and heat flow in the polar wind. The 13-moment system of transport equations developed by Schunk (1975, 1977), which contains a continuity, momentum, internal energy, stress tensor and heat flow equation for each species, is employed to represent the electrons, with a simplified set of transport equations used for the ions, and the transport equations are solved at altitudes from 1500 to 12,000 km for both subsonic and supersonic H(+) outflows. For subsonic H(+) outflows, the electron gas is found to remain collision dominated to high altitudes. For supersonic H(+) outflows, the electron gas is also found to be collision dominated at altitudes below 2500 km, with an anisotropy in electron temperature distribution developing such that the temperature of the perpendicular electrons is greater than that of the parallel electrons at higher altitudes. In addition, the magnitude of downward electron heat flux at 1500 km is shown to have a dramatic effect on the individual parallel and perpendicular electron temperatures.

Schunk, R. W.↗

Potato growth and yield using nutrient film technique (NFT)

Potato plants, cvs Denali and Norland, were grown in polyvinyl chloride (PVC) trays using a continuous flowing nutrient film technique (NFT) to study tuber yield for NASA's Controlled Ecological Life Support Systems (CELSS) program. Nutrient solution pH was controlled automatically using 0.39M (2.5% (v/v) nitric acid (HNO3), while water and nutrients were replenished manually each day and twice each week, respectively. Plants were spaced either one or two per tray, allotting 0.2 or 0.4 m2 per plant. All plants were harvested after 112 days. Denali plants yielded 2850 and 2800 g tuber fresh weight from the one- and two-plant trays, respectively, while Norland plants yielded 1800 and 2400 g tuber fresh weight from the one- and two-plant trays. Many tubers of both cultivars showed injury to the periderm tissue, possibly caused by salt accumulation from the nutrient solution on the surface. Total system water usage throughout the study for all the plants equaled 709 liters (L), or approximately 2 L m-2 d-1. Total system acid usage throughout the study (for nutrient solution pH control) equaled 6.60 L, or 18.4 ml m-2 d-1 (7.2 mmol m-2 d-1). The results demonstrate that continuous flowing nutrient film technique can be used for tuber production with acceptable yields for the CELSS program.

NASA Discipline Number 61-20↗

An efficient supersonic wind tunnel drive system for Mach 2.5 flows

A novel efficient drive system has been developed which provides for the continuous operation of a pitot Mach 2.5 wind tunnel at compression ratios down to 0.625:1. The drive system does not require an overpressure to start, and no hysteresis has been observed. The general design of the proof-of-concept wind tunnel using the new drive system and its modifications are described.

Wolf, Stephen W. D.↗

A nanoporous capacitive electrochemical ratchet for continuous ion separations

Directed ion transport in liquid electrolyte solutions underlies many phenomena in natural and industrial settings. While nature has evolved structures that drive continuous ion flow without Faradaic redox reactions, establishing this process in synthetic systems has been challenging. Here, in this study, we report an ion pump that drives aqueous ions against a force using a capacitive ratchet mechanism independent of redox reactions. Modulation of an electric potential between thin metallic layers on either face of a nanoporous alumina wafer immersed in solution results in persistent voltages and ionic currents. This occurs due to the nonlinear capacitive nature of electric double layers, whose repeated charging and discharging sustains a continuous ion flux. Using this approach, we demonstrate ratchet-driven electrodialysis that reaches a 50% decrease in the conductivity of the solution in a dilution cell. These ratchet-based ion pumps can enable continuous desalination and selective ion separation using an electrically powered device with no moving parts.

Kautz, Rylan [University of California, Irvine, CA↗

Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

Testing and Results of Vacuum Swing Adsorption Units for Spacesuit Carbon Dioxide and Humidity Control

A principal concern for extravehicular activity (EVA) space suits is the capability to control carbon dioxide (CO2) and humidity (H2O) for the crewmember. The release of CO2 in a confined or unventilated area is dangerous for human health and leads to asphyxiation; therefore, CO2 and H2O become leading factors in the design and development of the spacesuit. An amine-based CO2 and H2O vapor sorbent for use in pressure-swing re-generable beds has been developed by Hamilton Sundstrand. The application of solid-amine materials with vacuum swing adsorption technology has shown the capacity to concurrently manage CO2 and H2O levels through a fully regenerative cycle eliminating mission constraints imposed with non-regenerative technologies. Two prototype solid amine-based systems, known as rapid cycle amine (RCA), were designed to continuously remove CO2 and H2O vapor from a flowing ventilation stream through the use of a two-bed amine based, vacuum-swing adsorption system. The Engineering and Science Contract Group (ESCG) RCA is the first RCA unit implementing radial flow paths, whereas the Hamilton Sundstrand RCA was designed with linear flow paths. Testing was performed in a sea-level pressure environment and a reduced-pressure environment with simulated human metabolic loads in a closed-loop configuration. This paper presents the experimental results of laboratory testing for a full-size and a sub-scale test article. The testing described here characterized and evaluated the performance of each RCA unit at the required Portable Life Support Subsystem (PLSS) operating conditions. The test points simulated a range of crewmember metabolic rates. The experimental results demonstrate the ability of each RCA unit to sufficiently remove CO2 and H2O from a closed loop ambient or subambient atmosphere.

McMillin, Summer↗