Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVERSION RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

THE CO-TO-H{sub 2} CONVERSION FACTOR AND DUST-TO-GAS RATIO ON KILOPARSEC SCALES IN NEARBY GALAXIES

We present ∼kiloparsec spatial resolution maps of the CO-to-H{sub 2} conversion factor (α{sub CO}) and dust-to-gas ratio (DGR) in 26 nearby, star-forming galaxies. We have simultaneously solved for α{sub CO} and the DGR by assuming that the DGR is approximately constant on kiloparsec scales. With this assumption, we can combine maps of dust mass surface density, CO-integrated intensity, and H I column density to solve for both α{sub CO} and the DGR with no assumptions about their value or dependence on metallicity or other parameters. Such a study has just become possible with the availability of high-resolution far-IR maps from the Herschel key program KINGFISH, {sup 12}CO J = (2-1) maps from the IRAM 30 m large program HERACLES, and H I 21 cm line maps from THINGS. We use a fixed ratio between the (2-1) and (1-0) lines to present our α{sub CO} results on the more typically used {sup 12}CO J = (1-0) scale and show using literature measurements that variations in the line ratio do not affect our results. In total, we derive 782 individual solutions for α{sub CO} and the DGR. On average, α{sub CO} = 3.1 M{sub ☉} pc{sup –2} (K km s{sup –1}){sup –1} for our sample with a standard deviation of 0.3 dex. Within galaxies, we observe a generally flat profile of α{sub CO} as a function of galactocentric radius. However, most galaxies exhibit a lower α{sub CO} value in the central kiloparsec—a factor of ∼2 below the galaxy mean, on average. In some cases, the central α{sub CO} value can be factors of 5-10 below the standard Milky Way (MW) value of α{sub CO,{sub MW}} = 4.4 M{sub ☉} pc{sup –2} (K km s{sup –1}){sup –1}. While for α{sub CO} we find only weak correlations with metallicity, the DGR is well-correlated with metallicity, with an approximately linear slope. Finally, we present several recommendations for choosing an appropriate α{sub CO} for studies of nearby galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

IR studies of the impact of Ge doping on the successive conversion of VO{sub n} defects in Czochralski-Si containing carbon

We report infrared absorption studies of oxygen-related defects in electron-irradiated Ge-doped Czochralski-Si. Our investigation was mainly focused on the reaction channel leading to the formation of VO{sub n} (1{<=}n{<=}6) defects. The VO{sub n} defects form mainly upon annealing, as a result of the successive aggregation of oxygen atoms in the initial VO defect produced by the irradiation: (VO+O{sub i}{yields}VO{sub 2}+O{sub i}{yields}VO{sub 3}+O{sub i}{yields}VO{sub 4},...). It was found that the ratio of the conversion of VO{sub n} to VO{sub n+1} defects is sensitive to the Ge content of the material. In particular, the ratio of the conversion of the VO to the VO{sub 2} defects was found to decrease with the increase in Ge concentration of the samples, although the opposite trend was observed for the VO{sub 3} to VO{sub 4} conversion. However, the VO{sub 2} to VO{sub 3} conversion changes only slightly with Ge content, being practically unaffected for Ge concentrations up to 2x10{sup 20} cm{sup -3}. In the case of VO{sub 2} formation, the phenomenon was attributed to the elastic strains induced in the lattice due to the Ge presence which affects the balance between the reactions VO+O{sub i}{yields}VO{sub 2}, VO+Si{sub I}{yields}O{sub i}, mainly involved in the decay of the VO and the growth of the VO{sub 2} defects. In the case of VO{sub 4} formation, the phenomenon was discussed by taking into account the enhancement of the diffusivity of the O{sub i} atoms in the Ge-doped Si, which could lead to an enhancement of the rate of the reaction VO{sub 3}+O{sub i}{yields}VO{sub 4}. For the VO{sub 3} formation this effect is practically negligible due to the fact that at the temperatures of VO{sub 2} to VO{sub 3} conversion oxygen diffusivity is quite small. The exhibited behavior in the conversion of the VO{sub n} to VO{sub n+1} defects (n=1,2,3) was similar in Ge-doped samples with low carbon content ([C{sub s}]<2x10{sup 16} cm{sup -3}) and in Ge-doped samples with high carbon content ([C{sub s}]{>=}1x10{sup 17} cm{sup -3}). The impact of C as well as its role in the conversion efficiency of VO to VO{sub 2} was studied by comparing the spectra in low carbon and high carbon Ge free Si material. Furthermore, a pair of bands at (1037,1051 cm{sup -1}) was attributed to the VO{sub 5} defect. The origin of another pair of bands (967,1005 cm{sup -1}) was discussed and tentatively correlated with a VO{sub n}C{sub s} structure. The role of Ge and C in the formation of the latter two pairs of bands was discussed.

36 MATERIALS SCIENCE↗

Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescription doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged value of F{sub n} was 1.75/1.18. F{sub r} of 1.1 has been applied to gynecological cancer implants with expected acute reactions and outcomes as expected based on extensive experience with permanent implants. The calculation also gave the average Cs-131 dose of 126 Gy converted from the I-125 dose of 144 Gy for prostate implants. Conclusions: Inclusion of an allowance for resensitization led to significant dose corrections for Cs-131 permanent implants, and should be applied to prescription dose calculation. The adjustment of the Cs-131 prescription doses with resensitization correction for gynecological permanent implants was consistent with clinical experience and observations. However, the Cs-131 prescription doses converted from other implant doses can be further adjusted based on new experimental results, clinical observations, and clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GOODS-HERSCHEL: GAS-TO-DUST MASS RATIOS AND CO-TO-H{sub 2} CONVERSION FACTORS IN NORMAL AND STARBURSTING GALAXIES AT HIGH-z

We explore the gas-to-dust mass ratio (M{sub gas}/M{sub d}) and the CO luminosity-to-M{sub gas} conversion factor ({alpha}{sub CO}) of two well-studied galaxies in the Great Observatories Origins Deep Survey North field that are expected to have different star-forming modes, the starburst GN20 at z = 4.05 and the normal star-forming galaxy BzK-21000 at z = 1.52. Detailed sampling is available for their Rayleigh-Jeans emission via ground-based millimeter (mm) interferometry (1.1-6.6 mm) along with Herschel PACS and SPIRE data that probe the peak of their infrared emission. Using the physically motivated Draine and Li models, as well as a modified blackbody function, we measure the dust mass (M{sub dust}) of the sources and find (2.0{sup +0.7} {sub -0.6} x 10{sup 9}) M{sub sun} for GN20 and (8.6{sup +0.6} {sub -0.9} x 10{sup 8}) M{sub sun} for BzK-21000. The addition of mm data reduces the uncertainties of the derived M{sub dust} by a factor of {approx}2, allowing the use of the local M{sub gas}/M{sub d} versus metallicity relation to place constraints on the {alpha}{sub CO} values of the two sources. For GN20 we derive a conversion factor of {alpha}{sub CO} < 1.0 M{sub sun} pc{sup -2} (K km s{sup -1}){sup -1}, consistent with that of local ultra-luminous infrared galaxies, while for BzK-21000 we find a considerably higher value, {alpha}{sub CO} {approx}4.0 M{sub sun} pc{sup -2} (K km s{sup -1}){sup -1}, in agreement with an independent kinematic derivation reported previously. The implied star formation efficiency is {approx}25 L{sub sun}/M{sub sun} for BzK-21000, a factor of {approx}5-10 lower than that of GN20. The findings for these two sources support the existence of different disk-like and starburst star formation modes in distant galaxies, although a larger sample is required to draw statistically robust results.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-30: A Factor for Converting Dose to a Gold Nanoparticle Mixture to a Biologically-Relevant Dose

Purpose: Monte Carlo studies of gold nanoparticle (GNP) dose enhancement on macroscopic scales in radiotherapy have modeled GNPs in tissue as a homogeneous mixture of gold and tissue. Using an explicit model of GNPs randomly positioned in a small volume (1 µm{sup 3}) of tissue, this study aims to quantify the dose to the biologically relevant component of a goldtissue mixture, enabling a conversion from macroscopically-scored dose. Methods: Using the PENELOPE Monte Carlo code with the penEasy package, we modeled a 1 µm{sup 3} volume containing either a tissue-gold mixture or GNPs suspended in ICRU 4-component tissue at various gold concentrations (0, 5, 10, and 15 mg Au/g tissue) and GNP diameters (20, 30, 40, 50 nm). The volume was irradiated with monoenergetic photon and electron beams, ranging from 110 eV to 6 MeV. Interaction forcing was utilized to increase simulation efficiency. Energy deposition was scored in the tissue for each case and was converted to dose. For each scenario, we calculated a conversion factor, the ratio of dose-to-tissue to dose-to-mixture as a function of energy. Results: The conversion factor was plotted as a function of energy for both photons and electrons. For electrons, the conversion factor was relatively unaffected by any of the parameters, including energy, ranging between 0.98–1.02. For photons, the factor was very energy dependent, with a range of 0.49–1.02. The factor was lowest for 10–100 keV photons. The conversion factor generally decreased with increasing GNP concentration and increasing GNP size. Conclusion: With a large variation in the conversion factor with incident energy, dose deposition is dependent on the spectrum incident on a volume. By scoring the energy spectrum in a given volume, one can provide a scenario-specific conversion factor, allowing fast, detailed Monte Carlo simulations without the need for explicit GNP-definition.

60 APPLIED LIFE SCIENCES↗

Towards the construction of the Mu2e electromagnetic calorimeter at Fermilab

Mu2e will search for the Charge Lepton Flavor Violating (CLFV) conversion of a muon into an electron in the field of a nucleus. A clean discovery signature is provided by the mono-energetic conversion electron (E e = 104.96 MeV). If no events are observed, Mu2e will set a limit on the ratio between the conversion and the nuclear capture rate below 3 × 10$^{-17}$ (at 90% C.L.). In order to confirm that the observed candidate is an electron, the calorimeter resolution requirements are to provide E res < 10%, T res < 500 ps for 100 MeV electrons while working in vacuum and in a high radiation environment and high magnetic field. The calorimeter is made of two annular aluminum disks, each one filled with 674 pure CsI crystals read out by SiPMs. A sophisticated mechanics and cooling system has been developed to support the crystals and cool the sensors. Radiation hard analog and fast digital electronics have been developed. In this paper the QC tests performed on the produced components and the construction status are reported, as well as the results obtained on the large size prototype with test beam data and at a cosmic ray test stand.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Propane vehicles : status, challenges, and opportunities.

Propane as an auto fuel has a high octane value and has key properties required for spark-ignited internal combustion engines. To operate a vehicle on propane as either a dedicated fuel or bi-fuel (i.e., switching between gasoline and propane) vehicle, only a few modifications must be made to the engine. Until recently propane vehicles have commonly used a vapor pressure system that was somewhat similar to a carburetion system, wherein the propane would be vaporized and mixed with combustion air in the intake plenum of the engine. This leads to lower efficiency as more air, rather than fuel, is inducted into the cylinder for combustion (Myers 2009). A newer liquid injection system has become available that injects propane directly into the cylinder, resulting in no mixing penalty because air is not diluted with the gaseous fuel in the intake manifold. Use of a direct propane injection system will improve engine efficiency (Gupta 2009). Other systems include the sequential multi-port fuel injection system and a bi-fuel 'hybrid' sequential propane injection system. Carbureted systems remain in use but mostly for non-road applications. In the United States a closed-loop system is used in after-market conversions. This system incorporates an electronic sensor that provides constant feedback to the fuel controller to allow it to measure precisely the proper air/fuel ratio. A complete conversion system includes a fuel controller, pressure regulator valves, fuel injectors, electronics, fuel tank, and software. A slight power loss is expected in conversion to a vapor pressure system, but power can still be optimized with vehicle modifications of such items as the air/fuel mixture and compression ratios. Cold start issues are eliminated for vapor pressure systems since the air/fuel mixture is gaseous. In light-duty propane vehicles, the fuel tank is typically mounted in the trunk; for medium- and heavy-duty vans and trucks, the tank is located under the body of the vehicle. Propane tanks add weight to a vehicle and can slightly increase the consumption of fuel. On a gallon-to-gallon basis, the energy content of propane is 73% that of gasoline, thus requiring more propane fuel to travel an equivalent distance, even in an optimized engine (EERE 2009b).

02 PETROLEUM↗

A Monte Carlo study of flux ratios of raman scattered o vi features at 6825 and 7082 Å in symbiotic stars

Symbiotic stars are regarded as wide binary systems consisting of a hot white dwarf and a mass losing giant. They exhibit unique spectral features at 6825 and 7082 Å, which are formed via Raman scattering of O vi λλ 1032 and 1038 with atomic hydrogen. We adopt a Monte Carlo technique to generate the same number of O vi λ1032 and λ1038 line photons and compute the flux ratio F(6825)/F(7082) of these Raman scattered O vi features formed in neutral regions with a simple geometric shape as a function of H i column density N {sub H i}. In cylindrical and spherical neutral regions with the O vi source embedded inside, the flux ratio F(6825)/F(7082) shows an overall decrease from 3 to 1 as N {sub H i} increases in the range 10{sup 22--24} cm{sup −2}. In cases of slab geometry and other geometries with the O vi source outside the H i region, Rayleigh escape operates to lower the flux ratio considerably. For moderate values of N{sub HI}∼10{sup 23} cm{sup −2} the flux ratio behaves in a complicated way to exhibit a broad bump with a peak value of 3.5 in the case of a sphere geometry. We find that the ratio of Raman conversion efficiencies of O vi λλ 1032, 1038 ranges from 0.8 to 3.5. Our high resolution spectra of “D” type HM Sge and “S” type AG Dra obtained with the Canada–France–Hawaii Telescope show that the flux ratio F(6825)/F(7082) of AG Dra is significantly smaller than that of HM Sge, implying that “S” type symbiotics are characterized by higher N {sub H i} than “D” type symbiotics.

79 ASTRONOMY AND ASTROPHYSICS↗

Super-radiant backward-wave oscillators with enhanced power conversion

We propose a method for a very significant increase of the peak power of a backward-wave electron oscillator operating in the non-stationary regime of the super-radiation of short rf pulses. This method is based on sectioning: a regular self-oscillator section is supported with a section providing amplification of the super-radiant pulse. Profiling of a resonant parameter in the amplifying section is used to avoid the parasitic self-excitation and to increase the efficiency of the electron-wave interaction. In such systems, the conversion factor (the ratio between the rf pulse power and the electron beam power) can achieve a few hundred percent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Mu2e experiment at Fermilab: Design and status

The Mu2e experiment at Fermilab will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus. The dynamics of such charged lepton flavour violating (CLFV) process is a twobody decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates Rμe of ≤ 6 × 10 -17 (@90% C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for μ → eγ decay at MEG as well as the direct searches for new physics at the LHC. Indeed, such a CLFV process probes new physics at a scale inaccessible to direct searches at either present or planned high energy colliders. Observation of a signal will be a clear evidence for new physics beyond the Standard Model. To search for the muon conversion process, a very intense pulsed beam of negative muons (~ 10 10 μ/s) is stopped on an aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and an electromagnetic calorimeter consisting of arrays of CsI crystals. An external veto for cosmic rays is surrounding the detector solenoid. In 2016, Mu2e has passed the final approval stage from DOE and has started its construction phase. Data collection is planned for the end of 2021. Lastly, an overview of the physics motivations for Mu2e, the current status of the experiment and design of the muon beam-line and the detector is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e crystal calorimeter

The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, μ - + Al → e - +Al. Data collection start is planned for the end of 2021. The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates R μe = μ - + A(Z,N) → e - +A(Z,N)/μ - + A(Z,N) → ν μ - +A(Z-1,N) of ≤ 6 ×10 -17 (@ 90% C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for μ → e γ decay at MEG as well as the direct searches for new physics at the LHC . The observation of such CLFV process could be clear evidence for New Physics beyond the Standard Model. Given its sensitivity, Mu2e will be able to probe New Physics at a scale inaccessible to direct searches at either present or planned high energy colliders. To search for the muon conversion process, a very intense pulsed beam of negative muons (~ 10 10 μ/ sec) is stopped on an Aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and a CsI crystals electromagnetic calorimeter. An external veto for cosmic rays surrounds the detector solenoid. In 2016, Mu2e has passed the final approval stage from DOE and has started its construction phase. As a result, an overview of the physics motivations for Mu2e, the current status of the experiment and the required performances and design details of the calorimeter are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e crystal calorimeter

The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, $\mu^- + Al \to e^- +Al$. Data collection start is planned for the end of 2021. The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates %\convrate of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). R$_{\mu e} = \frac{\mu^- + A(Z,N) \to e^- +A(Z,N)}{\mu^- + A(Z,N) \to \nu_{\mu} ^- +A(Z-1,N)} $ of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for $\mu \to e \gamma$ decay at MEG as well as the direct searches for new physics at the LHC. The observation of such CLFV process could be clear evidence for New Physics beyond the Standard Model. Given its sensitivity, Mu2e will be able to probe New Physics at a scale inaccessible to direct searches at either present or planned high energy colliders. To search for the muon conversion process, a very intense pulsed beam of negative muons ($\sim 10^{10} \mu/$ sec) is stopped on an Aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and a CsI crystals electromagnetic calorimeter. An overview of the physics motivations for Mu2e, the current status of the experiment and the required performances and design details of the calorimeter are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Renewable diesel and bio-aromatics production from waste cooking oil using ethanol as a hydrogen donor in deoxygenation reaction

Biofuels offer a promising solution in the fight against climate change. With a global increase in waste cooking oil, this research investigated the production of bio-hydrogenated diesel (BHD) from waste cooking oil, using ethanol as a hydrogen donor in the deoxygenation process. A hydrolyzed waste cooking oil model compound served as the feedstock, and the deoxygenation was performed at 300–400 °C. The catalysts used in the experiments were 2.6 wt% Ni and 7.8 wt% Mo (2.6Ni-7.8Mo) and 10 wt% Ni and 5 wt% Mo (10Ni-5Mo) on γ-Al 2 O 3 . The results showed that ethanol is an effective hydrogen donor for biofuel production without the need for external hydrogen at an elevated pressure. The increasing temperature enhanced the free fatty acid (FFA) conversion and n-alkane selectivity in the oil product, with the highest FFA conversion and alkane selectivity of 100 % and 46 %, respectively, observed at 400 °C for the sulfided 10Ni-5Mo catalyst. On the other hand, 2.6Ni-7.8Mo offers 100 % FFA conversion with a lower n-alkane selectivity of 35 % at identical temperatures. The total acid number (TAN) of the oil products decreased from 174.03 mg KOH/g of feedstock to 9.43 and 8.67 mg KOH/g with the sulfided 2.6Ni-7.8Mo and 10Ni-5Mo catalysts, respectively. Both the catalysts achieved similar heating values (~43 MJ/kg) at 400 °C. This is a significant improvement to the HHV of the feedstock, which was 36.02 MJ/kg. Additionally, aromatic compounds, mainly BTXE (benzene, toluene, xylene, and ethylbenzene), were also produced. Compared to glycerol as a hydrogen donor, ethanol more effectively increased n-alkane selectivity due to its higher effective hydrogen-to-carbon ratio (H/C eff ). Conversely, glycerol was more advantageous for achieving greater selectivity towards BTXE compounds due to its lower H/C eff , which potentially leads to coke formation. Since aromatic compounds are intermediates in coke production, glycerol provides higher aromatic selectivity than ethanol. Finally, this study presents an alternative pathway for producing diesel fuel from waste cooking oil using ethanol as a hydrogen donor.

36 MATERIALS SCIENCE↗

Luminescence thermometry below room temperature via up-conversion emission of Y{sub 2}O{sub 3}:Yb{sup 3+},Er{sup 3+} nanophosphors

This study explores potential of Er{sup 3+}-Yb{sup 3+} doped phosphors for up-conversion luminescence thermometry in the temperature range from 10 K to 300 K. Yttrium oxide nanopowder doped with trivalent ytterbium and erbium ions (Y{sub 1.97}Yb{sub 0.02}Er{sub 0.01}O{sub 3}) was prepared by hydrothermal synthesis as an example. The intensity ratios of up-conversion emissions from thermally coupled {sup 2}H{sub 11/2} and {sup 4}S{sub 3/2} levels of Er{sup 3+} show strong temperature dependence (in the range 150 K–300 K) with much higher relative sensitivity than those reported for thermometry above room temperature with Er{sup 3+}-Yb{sup 3+} based up-conversion materials. The maximal value of relative sensitivity is 5.28%K{sup −1} at 150 K, with temperature resolution ranging from 0.81 K to 0.06 K. In addition, the intensity ratios of emission from thermally non-coupled Er{sup 3+} levels ({sup 2}H{sub 9/2} and {sup 4}F{sub 9/2}) and from {sup 4}S{sub 3/2} also show temperature dependence that can be approximated with an exponential function. With these up-conversion emission ratios, it is possible measure temperature in the range of 10 K to 300 K with excellent sensitivity and resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative Investigation of Benzene Steam Reforming over Spinel Supported Rh and Ir Catalysts

In a combined experimental and first-principles density functional theory (DFT) study, benzene steam reforming (BSR) over MgAl 2 O 4 supported Rh and Ir catalysts was investigated. Experimentally, it has been found that both highly dispersed Rh and Ir clusters (1-2 nm) on the MgAl 2 O 4 spinel support are stable during the BSR in the temperature range of 700-850°C. Compared to the Ir/MgAl 2 O 4 catalyst, the Rh/MgAl 2 O 4 catalyst is more active with higher benzene turnover frequency and conversion. At typical steam conditions with the steam-to-carbon ratio > 12, the benzene conversion is only a weak function of the H 2 O concentration in the feed. This suggests that the initial benzene decomposition step rather than the benzene adsorption is most likely the rate-determined step in BSR over supported Rh and Ir catalysts. In order to understand the differences between the two catalysts, we followed with a comparative DFT study of initial benzene decomposition pathways over two representative model systems for each supported metal (Rh and Ir) catalysts. A periodic terrace (111) surface and an amorphous 50-atom metal cluster with a diameter of 1.0 nm were used to represent the two supported model catalysts under low and high dispersion conditions. Our DFT results show that the decreasing catalyst particle size enhances the benzene decomposition on supported Rh catalysts by lowering both C-C and C-H bond scission. The activation barriers of the C-C and the C-H bond scission decrease from 1.60 and 1.61 eV on the Rh(111) surface to 1.34 and 1.26 eV on the Rh50 cluster. For supported Ir catalysts, the decreasing particle size only affects the C-C scission. The activation barrier of the C-C scission of benzene decreases from 1.60 eV on the Ir(111) surface to 1.35 eV on the Ir50 cluster while the barriers of the C-H scission are practically the same. The experimentally measured higher BSR activity on the supported highly dispersed Rh catalyst can be rationalized by the thermodynamic limitation for the very first C-C bond scission of benzene on the small Ir50 catalyst. The C-C bond scission of benzene on the small Ir50 catalyst is highly endothermic although the barrier is competitive with the barriers of both the C-C and the C-H bond-breakings on the small Rh50 catalyst. The calculations also imply that, for the supported Rh catalysts the C-C and C-H bond scissions are competitive, independently of the Rh cluster sizes. After the initial dissociation step via either the C-C or the C-H bond scission, the C-H bond breaking seems to be more favorable rather than the C-C bond breaking on the larger Rh terrace surface. This work was financially supported by the United States Department of Energy’s Office of Biomass Program’s. Computing time was granted by a user project at the Molecular Science Computing Facility in the William R. Wiley Environmental Molecular Sciences Laboratory (EMSL), a national scientific user facility sponsored by the Department of Energy's Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

H II regions and the abundance properties of spiral galaxies

We investigate the relationships between the characteristic oxygen abundance, the radial abundance gradient, and the macroscopic properties of spiral galaxies by examining the properties of individual H II regions within those galaxies. Our observations of the line flux ratio (O II) lambda lambda 3726, 3729 + (O III) lambda lambda 4959, 5007)/H beta for 159 H II regions in 14 spiral galaxies are combined with published data to provide a sample of 39 disk galaxies for which (O II) + (O III)/H beta has been measured for at least five H II regions. We find that the characteristic gas-phase abundances and luminosities of spiral galaxies are strongly correlated. This relationship maps almost directly onto the luminosity-metallicity relationship of irregular galaxies and is also quite similar to that found for elliptical and dwarf spheroidal galaxies. Within our sample of spirals, a strong correlation between characteristic abundance and Hubble type also exists. The correlation between luminosity and Hubble type complicates the issue, but we discuss several interpretations of the correlations. The relationship between circular velocity and characteristic abundance is also discussed. We find that the slopes of the radial abundance gradients, when expressed in units of dex/isophotal radius, do not significantly correlate with either luminosity or Hubble type. However, the hypothesis that both early and very late type spirals have shallower gradients than intermediate spirals is consistent with the data. We find suggestive evidence that the presence of a bar induces a flatter gradient and also briefly discuss whether abundance gradients are exponential, as is usually assumed. We investigate the properties of individual H II regions in a subset of 42 regions for which we have spectra that cover almost the entire spectral range from 3500 to 9800 A. We use those data to estimate the densitites and ionizing spectra within the H II regions. We confirm that the ionizing spectrum hardens with increasing radius and decreasing abundance. We find no correlation between the ionization parameter and either radius or abundance, but this may be due to significant scatter introduced by the simple conversion of line ratios to ionization parameter.

Zaritsky, Dennis↗

ITAR: A modified TAR method to determine depth dose distribution for an ophthalmic device that performs kilovoltage x-ray pencil-beam stereotaxy

Purpose: New technology has been developed to treat age-related macular degeneration (AMD) using 100 kVp pencil-beams that enter the patient through the radio-resistant sclera with a depth of interest between 1.6 and 2.6 cm. Measurement of reference and relative dose in a kilovoltage x-ray beam with a 0.42 cm diameter field size and a 15 cm source to axis distance (SAD) is a challenge that is not fully addressed in current guidelines to medical physicists. AAPM's TG-61 gives dosimetry recommendations for low and medium energy x-rays, but not all of them are feasible to follow for this modality. Methods: An investigation was conducted to select appropriate equipment for the application. PTW's Type 34013 Soft X-Ray Chamber (Freiburg, Germany) and CIRS's Plastic Water LR (Norfolk, VA) were found to be the best available options. Attenuation curves were measured with minimal scatter contribution and thus called Low Scatter Tissue Air Ratio (LSTAR). A scatter conversion coefficient (C{sub scat}) was derived through Monte Carlo radiation transport simulation using MCNPX (LANL, Los Alamos, NM) to quantify the difference between a traditional TAR curve and the LSTAR curve. A material conversion coefficient (C{sub mat}) was determined through experimentation to evaluate the difference in attenuation properties between water and Plastic Water LR. Validity of performing direct dosimetry measurements with a source to detector distance other than the treatment distance, and therefore a different field size due to a fixed collimator, was explored. A method—Integrated Tissue Air Ratio (ITAR)—has been developed that isolates each of the three main radiological effects (distance from source, attenuation, and scatter) during measurement, and integrates them to determine the dose rate to the macula during treatment. Results: LSTAR curves were determined to be field size independent within the range explored, indicating that direct dosimetry measurements may be performed with a source to detector distance of 20 cm even though the SAD is 15 cm during treatment. C{sub scat} varied from 1.102 to 1.106 within the range of depths of interest. The experimental variance among repeated measurements of C{sub mat} was larger than depth dependence, so C{sub mat} was estimated as1.019 for all depths of interest. Conclusions: Equipment selection, measurement techniques, and formalism for the determination of dose rate to the macula during stereotaxy for AMD have been determined and are strongly recommended by the authors of this paper to be used by clinical medical physicists.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cr-free Fe-based metal oxide catalysts for high temperature water gas shift reaction of fuel processor using LPG

The goal of this study was to identify the most suitable chromium-free iron-based catalysts for the HTS (high temperature shift) reaction of a fuel processor using LPG. Hexavalent chromium (Cr6+) in the commercial HTS catalyst has been regarded as hazardous material. We selected Ni and Co as the substitution for chromium in the Fe-based HTS catalyst and investigated the HTS activities of these Crfree catalysts at LPG reformate condition. Cr-free Fe-based catalysts which contain Ni, Zn, or Co instead of Cr were prepared by coprecipitation method and the performance of the catalysts in HTS was evaluated under gas mixture conditions (42% H2, 10% CO, 37% H2O, 8% CO2, and 3% CH4; R (reduction factor): about 1.2) similar to the gases from steam reforming of LPG (100% conversion at steam/carbon ratio = 3), which is higher than R (under 1) of typically studied LNG reformate condition. Among the prepared Cr-free Febased catalysts, the 5 wt%-Co/Fe/20 wt%-Ni and 5 wt%-Zn/Fe/20 wt%-Ni catalysts showed good catalytic activity under this reaction condition simulating LPG reformate gas.

02 PETROLEUM↗