Search NASA⌕ Search

SEARCH · Search NASA

Results for “COOLING FIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

Cooling Panel Optimization for the Active Cooling System of a Hypersonic Aircraft

Optimization of cooling panels for an active cooling system of a hypersonic aircraft is explored. The flow passages are of rectangular cross section with one wall heated. An analytical fin-type model for incompressible flow in smooth-wall rectangular ducts with coupled wall conduction is proposed. Based on this model, the a flow rate of coolant to each design minimum mass flow rate or coolant for a single cooling panel is obtained by satisfying hydrodynamic, thermal, and Mach number constraints. Also, the sensitivity of the optimal mass flow rate of coolant to each design variable is investigated. In addition, numerical solutions for constant property flow in rectangular ducts, with one side rib-roughened and coupled wall conduction, are obtained using a k-epsilon and wall function turbulence model, these results are compared with predictions of the analytical model.

Youn, B.↗

Optimization of a heat-pipe-cooled space radiator for use with a reactor-powered Stirling engine

The design optimization of a reactor-Stirling heat-pipe-cooled radiator is presented. The radiator is a self-deploying concept that uses individual finned heat pipe 'petals' to reject waste heat from a Stirling engine. Radiator optimization methodology is presented, and the results of a parametric analysis of the radiator design variables for a 100-kW(e) system are given. The additional steps of optiminzing the radiator resulted in a net system mass savings of 3 percent.

Moriarty, Michael P.↗

Revolutionizing Turbine Cooling with Micro-Architectures Enabled by Direct Metal Laser Sintering

The objective of this research effort was to explore innovative cooling architectures enabled by additive manufacturing techniques for improved turbine cooling performance. The ability to create complex internal geometries was leveraged to better distribute coolant as well as to integrate inherently unstable flow devices to enhance internal and external heat transfer. This was accomplished with a multi-faceted approach including analytical, experimental, and computational components. This final report documents progress during the total 4.25 year effort that was extended (at no additional cost) from the original 3-year cooperative agreement. Prior to starting the project, significant effort was invested in investigating innovative cooling designs from the open literature. When the project started, we quickly down-selected to 4 configurations: impingement jet fluidic oscillators (for internal leading edge cooling), reverse film cooling (for pressure surface), sweeping film cooling jets (for suction surface), and trailing edge slot cooling with microchannels. During the 2nd year, the reverse film cooling design was shown to be sub-optimal and work on that topic was halted. The three remaining technologies were integrated into a large scale nozzle guide vane and installed into a low-speed linear cascade facility for further interrogation. Initial results showed the sweeping film cooling jets (on the suction surface) to be the most promising technology compared to a baseline diffusion shaped film hole (777 design). The benefit was particularly evident at high blowing ratios (>1.5) when the 777 coolant film separated from the downstream surface. Benefits were also evident at elevated freestream turbulence levels. The leading edge cooling with unsteady jets was less effective in terms of peak or average cooling – however it was superior to round hole impingement cooling in terms of spatial uniformity. Finally, the trailing edge cooling design with micro-channels was scrapped in favor of a pinned arrangement with centerbody. During the 3rd year, the same three technologies were integrated into a transonic linear cascade for an assessment of compressibility effects. Again, the sweeping film cooling jets proved superior at high blowing ratios while the unsteady leading edge impingement and trailing edge pin-fins with centerbody designs yielded mixed results. Finally, during the 4th and final year, these 3 technologies were integrated into a direct metal laser sintered (DMLS) nozzle guide vane for testing in a high temperature, transonic annular vane cascade. The facility matches the flow temperature, Mach number, and coolant pressure ratios of an actual gas turbine. Before doing this, an additional series of tests were completed to validate a redesigned trailing edge cooling architecture. This final design included a centerbody with triangular pins between the centerbody and the vane external skin. The majority of these triangular pins are fabricated with a 30% gap to the centerbody – reducing their pressure drop considerably while still providing excellent heat transfer augmentation. This additional test campaign required an additional 3-month extension request to complete testing in the high temperature NGV test facility (Turbine Reacting Flow Rig – TuRFR). Testing of the DMLS vane in TuRFR pitted the 3 innovative cooling technologies against more traditional technologies (shaped 777 film hole, round impingement jet, and full pin arrangement in the trailing edge. The sweeping film cooling jets (on the suction surface) showed approximately 15% improvement in overall effectiveness compared to the 777 film hole while the trailing edge showed up to 20% improvement. The leading edge impingement was disappointing with a substantially lower effectiveness than traditional direct impingement. In summary, the study was successful in demonstrating that DMLS-enabled cooling technologies can yield significant gains in cooling performance.

03 NATURAL GAS↗

Radioisotope thermoelectric generator cooling in the Shuttle bay

The paper describes a Shuttle-integrated radioisotope thermoelectric generator (RTG) that consists primarily of a pump package and plumbing connected directly to the Shuttle payload heat exchanger. The RTG utilizes on-board water evaporative cooling capability, which is normally used for ascent, entry, and for supplementing the radiators. Attention is given to the RTG cooling concepts which include: (1) an active thermal cooling system (ATCS), where two Freon-21 loops operate simultaneously to transport heat from the Orbiter subsystem and payloads through liquid-to-liquid heat exchangers and pin-fin coldplates to four heat sinks, and (2) an atmosphere revitalization system (ARS) which provides for thermal, pressure, and contaminate control of the crew cabin and its equipment. The use of a payload heat exchanger to reduce weight, cost and complexity associated with an independent cooling system was investigated in detail.

Stimpson, L. D.↗

Enhanced Surface Spray Cooling with Embedded and Compound Extended Surface Structures

Experiments were conducted to study the effects of enhanced surface structures on heat flux using spray cooling. The surface enhancements consisted of embedded structures (dimples, pores, and tunnels) and compound extended surface enhancements (straight fins, cubic pin fins and dimples) machined on and within the top surface of copper heater blocks. Each copper block had a projected cross-sectional area of 2.0 sq cm. Measurements were also obtained on a heater block with a flat surface for baseline comparison purposes. A 2x2 nozzle array was used with PF-5060 as the working fluid. Thermal performance data was obtained under nominally degassed (chamber pressure of 41.4 kPa) and gassy conditions (chamber with N2 gas at 101 kPa) with a bulk fluid temperature of 20.5 C. Results for both the nominally degassed and gassy cases show that the highest critical heat flux (CHF) was attained using straight fins and porous tunnels. For the nominally degassed case, both had a CHF of approx.: 142 W/sq cm while for the gassy case their CHF values increased to 175 W/sq cm. This gave an enhancement relative to the nominally degassed flat surface case of approx. 77% and 119% respectively.

Silk, Erie A.↗

Methane liquefaction with an active magnetic regenerative refrigerator

This manuscript reports liquefaction of methane using an active magnetic regenerative refrigerator (AMRR). The AMRR used to cool from 285 K to 135 K has two identical regenerators fabricated with adjacent layers of four ferromagnetic refrigerants, each with sequentially lower Curie temperatures and lesser masses from hot to cold temperatures. The dual multilayer regenerators were assembled in opposition with a single cold region between them. For this set of experiments equal mass of helium gas was pumped through all layers of the regenerators during the two flow steps of the four-step AMR cycle. After successfully reaching 135 K, a compact condensing coil-fin tube heat exchanger (HEX) with a small storage vessel was mounted in the cold region of the dual regenerator assembly to be cooled during the hot-to-cold helium flow from alternatively demagnetized regenerators. The cold HEX was used to cool and liquefy a process stream of methane gas supplied at 295 K and different pressures in different runs. Further, by measuring time to liquefy a known volume of methane at three different pressures, cooling powers of the AMRR as a function of temperature were determined. The resultant data were compared to those predicted by the AMRR performance model. Conclusions from these experiments and suggestions for future work are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel geometries for air-cooled condensation of ammonia-water mixtures

An analytical and experimental investigation of air-cooled condensers for small-scale ammonia-water absorption heat pumps is presented. Conventional round-tube corrugated fin design and a novel multi-pass tube array design are considered for a condenser operating at severe ambient conditions within a compact footprint. Segmental heat and mass transfer models are developed to gain a deeper understanding of the characteristics of each design. Predicted heat duties are within 5% of the measured values. The limitations of correlations to predict air-side pressure drop in corrugated fins are identified. The performance of the novel multi-pass tube array condenser was comparable to that of conventional condensers, but is determined to be air-side limited throughout length of the heat exchanger. An improved multi-pass condenser design with fins for increased air-side area is proposed using the insights gained from the modeling and experiments. In closing this design meets the heat duty requirements at severe ambient conditions, while decreasing the size of the heat exchanger by 33%.

42 ENGINEERING↗

An experimental/computational study of sharp fin induced shock wave/turbulent boundary layer interactions at Mach 5 - Experimental results

A combined experimental/computational study has been performed of sharp fin induced shock wave/turbulent boundary layer interactions at Mach 5. The current paper focuses on the experiments and analysis of the results. The experimental data include mean surface heat transfer, mean surface pressure distributions and surface flow visualization for fin angles of attack of 6, 8, 10, 12, 14 and 16-degrees at Mach 5 under a moderately cooled wall condition. Comparisons between the results and correlations developed earlier show that Scuderi's correlation for the upstream influence angle (recast in a conical form) is superior to other such correlations in predicting the current results, that normal Mach number based correlations for peak pressure heat transfer are adequate and that the initial heat transfer peak can be predicted using pressure-interaction theory.

Rodi, Patrick E.↗

Energy Loss, Velocity Distribution, and Temperature Distribution for a Baffled Cylinder Model, Special Report

In the design of a cowling a certain pressure drop across the cylinders of a radial air-cooled engine is made available. Baffles are designed to make use of this available pressure drop for cooling. The problem of cooling an air-cooled engine cylinder has been treated, for the most part, from considerations of a large heat-transfer coefficient. The knowledge of the precise cylinder characteristics that give a maximum heat-transfer coefficient should be the first consideration. The next problem is to distribute this ability to cool so that the cylinder cools uniformly. This report takes up the problem of the design of a baffle for a model cylinder. A study has been made of the important principles involved in the operation of a baffle for an engine cylinder and shows that the cooling can be improved 20% by using a correctly designed baffle. Such a gain is as effective in cooling the cylinder with the improved baffle as a 65% increase in pressure drop across the standard baffle and fin tips.

Brevoort, Maurice J.↗

Experimental Investigation of Air-Cooled Turbine Blades in Turbojet Engine. 7: Rotor-Blade Fabrication Procedures

An experimental investigation was conducted to determine the cooling effectiveness of a wide variety of air-cooled turbine-blade configurations. The blades, which were tested in the turbine of a - commercial turbojet engine that was modified for this investigation by replacing two of the original blades with air-cooled blades located diametrically opposite each other, are untwisted, have no aerodynamic taper, and have essentially the same external profile. The cooling-passage configuration is different for each blade, however. The fabrication procedures were varied and often unique. The blades were fabricated using methods most suitable for obtaining a small number of blades for use in the cooling investigations and therefore not all the fabrication procedures would be directly applicable to production processes, although some of the ideas and steps might be useful. Blade shells were obtained by both casting and forming. The cast shells were either welded to the blade base or cast integrally with the base. The formed shells were attached to the base by a brazing and two welding methods. Additional surface area was supplied in the coolant passages by the addition of fins or tubes that were S-brazed. to the shell. A number of blades with special leading- and trailing-edge designs that provided added cooling to these areas were fabricated. The cooling effectiveness and purposes of the various blade configurations are discussed briefly.

Long, Roger A.↗

Development of a High Output Fluorescent Light Module for the Commercial Plant Biotechnology Facility

To maximize the use of available resources provided onboard the International Space Station, the development of an efficient lighting 1 system is critical to the overall performance of the CPBF. Not only is it important to efficiently generate photon energy, but thermal loads on the CPBF Temperature and Humidity Control System must be minimized. By utilizing optical coatings designed to produce highly diffuse reflectance in the visible wavelengths while minimizing reflectance in the infrared region, the design of the fluorescent light module for the CPBF is optimized for maximum photon flux, spatial uniformity and energy efficiency. Since the Fluorescent Light Module must be fully enclosed to meet (ISS) requirements for containment of particulates and toxic materials, heat removal from the lights presented some unique design challenges. By using the Express Rack moderate C, temperature-cooling loop, heat is rejected by means of a liquid/air coolant manifold. Heat transfer to the manifold is performed by conduction using copper fins, by forced air convection using miniature fans, and by radiation using optically selective coatings that absorb in the infrared wavelengths. Using this combination of heat transfer mechanisms builds in redundancy to prevent thermal build up and premature bulb failure.

Turner, Mark↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

An Investigation of the Effects of Heat Transfer on Boundary-Layer Transition on a Parabolic Body of Revolution (NACA RM-10) at a Mach Number of 1.61

Report presents the results of an investigation conducted to determine the effects of heat transfer on boundary-layer transition on a parabolic body of revolution (NACA rm-10 without fins) at Mach number of 1.61 and over a Reynolds number range from 2.5 x 10(6) to 35 x 10(6). The maximum cooling of the model used in these tests corresponded to a temperature ratio (ratio of model-surface temperature to free-stream temperature) of 1.12, a value somewhat higher than the theoretical value required for infinite boundary-layer stability at this Mach number. The maximum heating corresponded to a temperature ratio of about 1.85. Included in the investigation was a study of the effects of surface irregularities and disturbances generated in the airstream on the ability of heat transfer to influence boundary-layer transition.

Czarnecki, K R↗

Thermal control of a lidar laser system using a non-conventional ram air heat exchanger

This paper describes the analysis and performance testing of a uniquely designed external heat exchanger. The heat exchanger is attached externally to an aircraft and is used to cool a laser system within the fuselage. Estimates showed insufficient cooling capacity with a conventional staggered tube array in the limited space available. Thus, a non-conventional design wes developed with larger tube and fin area exposed to the ram air to increase the heat transfer performance. The basic design consists of 28 circular finned aluminum tubes arranged in two parallel banks. Wind tunnel tests were performed to simulate air and liquid flight conditions for the non-conventional parallel bank arrangement and the conventional staggered tube arrangement. Performance comparisons of each of the two designs are presented. Test results are used in a computer model of the heat exchanger to predict the operating performance for the entire flight profile. These analyses predict significantly improved performance over the conventional design and show adequate thermal control margins.

Killough, Brian D.↗

CVB: The Constrained Vapor Bubble 40 mm Capillary Experiment on the ISS

Discuss the Constrained Vapor Bubble (CVB) 40mm Fin experiment on the ISS and how it aims to achieve a better understanding of the physics of evaporation and condensation and how they affect cooling processes in microgravity using a remotely controlled microscope and a small cooling device

microgravity↗

Computational Fluid Dynamics (CFD) Analysis Of Optical Payload For Lasercomm Science (OPALS) sealed enclosure module

Computational Fluid Dynamics (CFD) using the commercial CFD package CFDesign has been performed at NASA Jet Propulsion Laboratory (JPL) California Institute of Technology (Caltech) in support of the Phaeton Early Career Hire Program's Optical Payload for Lasercomm Science (OPALS) mission. The OPALS project is one which involves an International Space Station payload that will be using forced convection cooling in a hermetically sealed enclosure at 1 atm of air to cool "off-the-shelf" vendor electronics. The CFD analysis was used to characterize the thermal and fluid flow environment within a complicated labyrinth of electronics boards, fans, instrumentation, harnessing, ductwork and heat exchanger fins. The paradigm of iteratively using CAD/CAE tools and CFD was followed in order to determine the optimum flow geometry and heat sink configuration to yield operational convective film coefficients and temperature survivability limits for the electronics payload. Results from this current CFD analysis and correlation of the CFD model against thermal test data will be presented. Lessons learned and coupled thermal / flow modeling strategies will be shared in this paper.

Computational Fluid Dynamics (CFD)↗

Exploring the Limits of Cooling for Extreme Heat Flux Applications: Data Centers and Power Electronic

We developed an Extreme Heat Flux Micro-cooler (EHFµ-C) capable of removing heat flux of ~1 kW/cm 2 with a small temperature rise ~10°C. This represents greater than 10× reduction in thermal resistance compared to the state-of-the-art single-phase cooling technologies (~0.5 cm 2 -°C/W) that greatly increases the efficiency, resulting in improved performance and reliability for microprocessors and power electronics. The EHFµ-Cooler utilizes liquid wicking (no pump) and thin-film evaporation in a 30 µm thick wick porous microstructure such as copper inverse opal (CIO), silicon and AlN pin fins along with a 3D manifold (copper wiremesh and silicon) with liquid routing and vapor extraction channels achieving an unprecedented vapor quality ~ >0.9. The proposed EHFµ-Cooler significantly reduces device temperature, resulting in 25-50% improvement in reliability and device performance. Based on very conservative estimates, the total energy saving for data centers due to improved performance can be 6 billion kWh/year (>$300M). Better cooling, leading to more efficient, higher performance and more reliable power electronics, would save the nation 3 Quad of primary energy in 2030. Just for automotive application, a 10% increase in fuel efficiency for SiC-based power electronics equates to >20 million gallons of fuel savings annually. The proposed EHFµ-Cooler technology ensures the United States maintains its technological lead in high-performance computing and high-power electronics, while at the same time improving the energy efficiency, and as a result reducing energy-related emissions such as greenhouse gases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗