Search NASA⌕ Search

SEARCH · Search NASA

Results for “COSMIC MUONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Systematic Uncertainties and Cross-Checks for the NOvA Joint $\nu_\mu$+$\nu_e$ Analysis

The physics goals of NOvA are the constraints of neutrino oscillation parameters such as the octant of $\theta_{23}$, $\delta_{\rm{CP}}$, and the neutrino mass hierarchy via a joint fit to $\nu_{\mu}$ and $\nu_{e}$ oscillation spectrum. We do this by propagating $\nu_{\mu}$ from the world's most intense neutrino beam at Fermilab, over a baseline of 810 km to northern Minnesota, USA, and measure the $\nu_{\mu}$ to $\nu_{e}$ oscillation probability. NOvA announced its latest oscillation results, based on 8.85$\times10^{20}$ (6.9$\times10^{20}$) protons on target neutrino (antineutrino) data. Preliminary results for the allowed values of oscillation parameters are: $\Delta m^2_{32}=2.51^{+0.12}_{-0.08}\times 10^{-3} \mathrm{eV}^2$, $\mathrm{sin}^2\theta_{23} = 0.58 \pm 0.03$ (upper octant), and $\delta_{\rm{CP}}=0.17\pi$ with preference to the normal hierarchy. Reliable constraints on these oscillation parameters require a rigorous treatment of systematic uncertainties and thorough cross-checks. In this paper, we present an overview of the treatment of systematic uncertainties as well as cross-checks using muon removed simulations and cosmic muon bremsstrahlung showers.

Gandrajula, Reddy Pratap↗

The maximum detectable momentum for cosmic ray muons in the minos far detector.

A magnetic detector such as MINOS which is measuring the sign of muons has to deal with issues of bending, which depend on the magnetic field configuration, and multiple scattering, which depends on the amount of material which is traversed. Above some momentum which depends on these factors, the momentum cannot be resolved. Issues related to measurement of the muon charge ratio in MINOS are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon Reconstruction and Identification in CMS

We present the design strategies and status of the CMS muon reconstruction and identification identification software. Muon reconstruction and identification is accomplished through a variety of complementary algorithms. The CMS muon reconstruction software is based on a Kalman filter technique and reconstructs muons in the standalone muon system, using information from all three types of muon detectors, and links the resulting muon tracks with tracks reconstructed in the silicon tracker. In addition, a muon identification algorithm has been developed which tries to identify muons with high efficiency while maintaining a low probability of misidentification. The muon identification algorithm is complementary by design to the muon reconstruction algorithm that starts track reconstruction in the muon detectors. The identification algorithm accepts reconstructed tracks from the inner tracker and attempts to quantify the muon compatibility for each track using associated calorimeter and muon detector hit information. The performance status is based on detailed detector simulations as well as initial studies using cosmic muon data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector

Measurements of electrons from 𝜈𝑒 interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectra is derived, and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50 MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmogenic background rejection for the sterile neutrino search with the Short-Baseline Neutrino Program Far Detector

As the Short-Baseline Neutrino Program Far Detector, the ICARUS liquid argon time-projection chamber will operate at shallow depth and therefore be exposed to the full surface flux of cosmic rays. This poses a problematic background to the sterile neutrino search. A direct way to reject this background is to surround the cryostat with a detector capable of tagging incident cosmic muons with high efficiency, the Cosmic Ray Tagging System (CRT). I have worked to develop the CRT detector hardware and the simulation and reconstruction software. This system, currently undergoing installation, is approximately 25% commissioned and taking data. I have developed a powerful method for cosmogenic background rejection utilizing the CRT and Photon Detection System. Results from a simulation based study, informed by CRT data, demonstrate the power of the technique in rejecting cosmogenic events with little adverse impact on the neutrino sample.

Hilgenberg, Christopher Michael↗

Muon Radiography with the NOvA Near Detector

Information on the geological and man-made structures, directly contributing to the overburden of the NOvA Near Detector, located 100 m underground at Fermilab, are extracted from the cosmic muon data accumulated in the period April 2015 - October 2016. Results of this radiographic analysis of cosmic data are obtained by exploiting the acceptance symmetries of the NOvA detector. Radiographic maps of the overburden variations are acquired without subtracting the surface muon flux (free sky data) and without MC simulation of the cosmic muons attenuation in the homogeneous and flat overburden. By directly subtracting the angular muon track data measured by the NOvA Near Detector, arriving from directions having the same attenuation length (in the flat-surface approximation) and belonging to the acceptance regions with the same reconstruction efficiency, one can efficiently obtain two-dimensional differential radiographic maps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of cross section of quark pair production top with the D0 experiment at the Tevatron and determination the top quark mass using this measure

The top quark has been discovered by CDF and D0 experiments in 1995 at the proton-antiproton collider Tevatron. The amount of data recorded by both experiments makes it possible to accurately study the properties of this quark: its mass is now known to better than 1% accuracy. This thesis describes the measurement of the top pair cross section in the electron muon channel with 4, 3 fb -1 recorded data between 2006 and 2009 by the D0 experiment. Since the final state included a muon, improvements of some aspects of its identification have been performed : a study of the contamination of the cosmic muons and a study of the quality of the muon tracks. The cross section measurement is in good agreement with the theoretical calculations and the other experimental measurements. This measurement has been used to extract a value for the top quark mass. This method allows for the extraction of a better defined top mass than direct measurements as it depends less on Monte Carlo simulations. The uncertainty on this extracted mass, dominated by the experimental one, is however larger than for direct measurements. In order to decrease this uncertainty, the ratio of the Z boson and the top pair production cross sections has been studied to look for some possible theoretical correlations. At the Tevatron, the two cross sections are not theoretically correlated: no decrease of the uncertainty on the extracted top mass is therefore possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibrating LArPix for TinyTPC

LArTPCs provide sensitivity to GeV signals, such as accelerator neutrinos and part of the supernova neutrino spectrum. TinyTPC is a LArTPC test stand for R&D of LAr doping to expand the reach of LArTPCs down to the 1-10 MeV range, which would substantially enhance the flagship analyses of experiments like DUNE, while enabling low energy analyses. We aim to dope LAr with Xe and pho- tosensitive dopants to expand the LArTPC range by converting hard-to-detect scintillation light to efficiently detected ionization charge. A critical element of the data analysis in TinyTPC is calibrating the readout. This poster will cover the calibration of TinyTPC, a pixelated liquid argon detector, where we find the distance a muon travels through each pixel. We then calculate the energy loss of muons traveling through the detector from cosmic data. We can reconstruct the path of the particles through the TPC using a density-based clustering algorithm designed to sort straight cosmic muon tracks from low energy radioactive decay curled paths and electronic noise

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon reconstruction in the Daya Bay water pools

Muon reconstruction in the Daya Bay water pools would serve to verify the simulated muon fluxes and offer the possibility of studying cosmic muons in general. This reconstruction is, however, complicated by many optical obstacles and the small coverage of photomultiplier tubes (PMTs) as compared to other large water Cherenkov detectors. The PMTs’ timing information is useful only in the case of direct, unreflected Cherenkov light. This requires PMTs to be added and removed as an hypothesized muon trajectory is iteratively improved, to account for the changing effects of obstacles and direction of light. Therefore, muon reconstruction in the Daya Bay water pools does not lend itself to a general fitting procedure employing smoothly varying functions with continuous derivatives. Here, we describe an algorithm which overcomes these complications. It employs the method of Least Mean Squares to determine an hypothesized trajectory from the PMTs’ charge-weighted positions. This initially hypothesized trajectory is then iteratively refined using the PMTs’ timing information. Reconstructions with simulated data reproduce the simulated trajectory to within about 5° in direction and about 45 cm in position at the pool surface, with a bias that tends to pull tracks away from the vertical by about 3°.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A technique for searching for the 2K capture in {sup 124}Xe with a copper proportional counter

An experimental technique for searching for the 2K capture in {sup 124}Xe with a large low-background copper proportional counter is described. Such an experiment is conducted at the Baksan Neutrino Observatory of the Institute for Nuclear Research of the Russian Academy of Sciences. The experimental setup is located in the Low-Background Deep-Level Laboratory at a depth of 4900 m.w.e., where the flux of muons of cosmic rays is suppressed by a factor of 10{sup 7} relative to that at the Earth’s surface. The setup incorporates a proportional counter and low-background shielding (18 cm of copper, 15 cm of lead, and 8 cm of borated polyethylene). The results of processing the data obtained in 5 months of live measurement time are presented. A new limit on the half-life of {sup 124}Xe with respect to the 2K capture is set at the level of 2.5 × 10{sup 21} years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ATLAS tile calorimeter performance at the LHC

The Tile Calorimeter (TileCal), the central section of the hadronic calorimeter of the ATLAS experiment, is a key detector component to detect hadrons, jets and taus and to measure the missing transverse energy. Due to the very good muon signal to noise ratio it assists the spectrometer in the identification and reconstruction of muons. TileCal is built of steel and scintillating tiles coupled to optical fibers and read out by photomultipliers. The calorimeter is equipped with systems that allow to monitor and to calibrate each stage of the read out system exploiting different signal sources: laser light, charge injection and a radioactive source. The performance of the calorimeter has been measured and monitored using calibration data, random triggered data, cosmic muons and more importantly LHC collision events. The results presented here assess the absolute energy scale calibration precision, the energy and timing uniformity and the synchronization precision. The ensemble of the results demonstrates a very good understanding of the performance of the Tile Calorimeter that is proved to be well within the design expectations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse Shape Discrimination study with Gd loaded liquid scintillator for reactor neutrino monitoring

Recently, technique of Gadolinium loaded liquid scintillator (Gd-LS) for reactor neutrino oscillation experiments has attracted attention as a monitor of reactor operation and 'nuclear Gain (GA)' for IAEA safeguards. For the practical use, R and D of the 1 ton class compact detector, which is measurable above ground, is necessary. Especially, it is important to reduce much amount of fast neutron background induced by cosmic muons with data analysis for the measurement above ground. We developed a prototype of the Gd-LS detector with 200 L of the target volume, which has Pulse Shape Discrimination (PSD) ability for the fast neutron reduction with data analysis. Usually, it is well known that it is difficult to keep high fast neutron reduction power of PSD with the large volume size such as the neutrino reactor monitor. We evaluated the PSD ability of our prototype with real fast neutrons induced by the muons in our laboratory above ground, and we could confirm to keep the high fast neutron reduction power with even our large detector size. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tau Trigger at the ATLAS Experiment

Many theoretical models, like the Standard Model or SUSY at large tan({beta}), predict Higgs bosons or new particles which decay more abundantly to final states including tau leptons than to other leptons. At the energy scale of the LHC, the identification of tau leptons, in particular in the hadronic decay mode, will be a challenging task due to an overwhelming QCD background which gives rise to jets of particles that can be hard to distinguish from hadronic tau decays. Equipped with excellent tracking and calorimetry, the ATLAS experiment has developed tau identification tools capable of working at the trigger level. This contribution presents tau trigger algorithms which exploit the main features of hadronic tau decays and describes the current tau trigger commissioning activities. Many of the SM processes being investigated at ATLAS, as well as numerous BSM searches, contain tau leptons in their final states. Being able to trigger effectively on the tau leptons in these events will contribute to the success of the ATLAS experiment. The tau trigger algorithms and monitoring infrastructure are ready for the first data, and are being tested with the data collected with cosmic muons. The development of efficiency measurements methods using QCD and Z {yields} {tau}{tau} events is well advanced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗