Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Search for gamma-ray bursts with coincident balloon flights

Dual balloon experiments were flown at separations of over 1,500 km in an attempt to determine whether cosmic gamma-ray bursts could be detected in the size region of 10 to the -7th power to several times 10 to the -6th power erg per sq cm, that is, below the apparent bend in the size spectrum of Vela events as described by Strong and Klebesadel. Fluctuations of the counting rates of photons above 150 keV with temporal structures from microseconds to several minutes were compared in order to detect coincident or associated responses from the two instruments. No coincident gamma-ray burst events were detected. Associated counting rate increases were detected, presenting a background, event-confusing problem for any single gamma-ray burst instrument beneath the earth's trapped radiation.

Cline, T. L.↗

High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories

X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x-ray calorimeter spectrometer, coupled with higher spectral resolution dispersive spectrometers to resolve line blends, has enabled many science investigations, to date mostly in our x-ray laboratory astrophysics program. These include measurements of absolute cross sections for Land K shell emission from Fe and Ni, charge exchange measurements in many astrophysically abundant elements, lifetime measurements, line ratios, and wavelength measurements. In addition, we have performed many additional measurements in nuclear physics, and in support of diagnostics for laser fusion, for example. In this presentation we will give a detailed overview of x-ray calorimeter instruments in general and in our EBIT laboratory astrophysics program in particular. We will also discuss the science yield of our measurements at EBIT over the last decade) prospects for future science enabled by the current generation of spectrometers and that will be expanded in the near future by the next generation of spectrometers starting in 2611.

Porter, Frederick S.↗

The Resource Prospector Neutron Spectrometer System: RP's Bloodhound

The primary goal of the Resource Prospector Neutron Spectrometer System (NSS) is to locate and characterize hydrogen-bearing volatile deposits, especially subsurface ice, that may exist at the lunar poles. A key objective is to detect water-equivalent hydrogen concentrations of 0.5 wt% or greater while on a moving rover. A second objective is to determine approximate burial depth of enhanced hydrogen-bearing materials up to 1 meter below otherwise dry regolith. The instrument will be carried aboard a landed mobility system at the lunar poles. The instrument operates by measuring the changes in the leakage flux of low energy neutrons out of the regolith. These neutrons are produced by galactic cosmic rays, which are so energetic that they shatter the nuclei in surface materials. The neutrons interact with other nuclei and lose energy, becoming thermalized in the process. Hydrogen is most efficient at thermalizing neutrons owing to protons' similar mass - statistically, neutrons lose half their energy per collision with protons. With hydrogen in the soil, leakage fluxes of neutrons in the 0.5 eV to 500 keV energy range are reduced. A concentration of only1-2 wt% water-equivalent hydrogen results in a decrease in epithermal leakage flux of a factor of two. The leakage flux of thermal neutrons, from 0 to 0.5 eV in energy, can either increase or decrease depending on the hydrogen abundance and stratigraphy. As with the highly successful Lunar Prospector Neutron Spectrometer, the RP NSS detects both thermal and epithermal neutrons by using two helium-3 gas proportional counters, one covered by cadmium and the other uncovered. The former detects only epithermal neutrons with energies above approximately 0.5 eV, the latter detects both thermal (less than 0.5 eV) and epithermal energies (greater than 0.5 eV). When a neutron enters the detector tube and interacts with a helium-3 nucleus, the resulting reaction produces an energetic proton and triton that ionize the gas. The resulting electrons are accelerated toward a high-voltage anode and cascade, amplifying the net charge, which is collected at the anode. The number of electrons produced is proportional to the energy that the triton and proton deposit in the gas. A charge sensitive pre-amplifier converts the total charge to a step voltage output. A shaper amplifier then shapes this step into a uni-polar waveform with peaking time appropriate for the detection depending on the event rate. The integrated shaped waveform, representing the deposited triton/proton energy, is then measured. A histogram, or pulse height analysis, is performed to record the main capture peak and wall effect pulses. A threshold for detection is also required to limit the low amplitude counting rate such as noise floor. The system electronics consists of 2 modules - the Sensor Module (SM) front-end and the Data Processing Module (DPM) back-end circuits. SM is designed as a light-weight and low power front-end housing the two helium-3 proportional counter detectors, preamp and HVPS. It is mounted external to the rover body to detect the thermalized neutron flux with a minimum of host background. The DPM is located inside the rover; it digitizes the SM signals, performs pulse height analysis and accumulates the count rate for each spectral channel. The DPM controls high voltage and thresholding, and sends the science data to the host craft via an RS422 serial asynchronous protocol. The payload host provides all thermal management and control for the SM and DPM.

hydrogen-bearing volatile deposits↗

Progress on the Use of Combined Analog and Photon Counting Detection for Raman Lidar

The Atmospheric Radiation Measurement (ARM) program Raman Lidar (CARL) was upgraded in 2004 with a new data system that provides simultaneous measurements of both the photomultiplier analog output voltage and photon counts. The so-called merge value added procedure (VAP) was developed to combine the analog and count-rate signals into a single signal with improved dynamic range. Earlier versions of this VAP tended to cause unacceptably large biases in the water vapor mixing ratio during the daytime as a result of improper matching between the analog and count-rate signals in the presence of elevated solar background levels. We recently identified several problems and tested a modified version of the merge VAP by comparing profiles of water vapor mixing ratio derived from CARL with simultaneous sonde data over a six month period. We show that the modified merge VAP significantly reduces the daytime bias, and results in mean differences that are within approximately 1% for both nighttime and daytime measurements.

Newsom, Rob↗

Delay Line Detectors for the UVCS and Sumer Instruments on the SOHO Satellite

Microchannel plate based detectors with cross delay line image readout have been rapidly implemented for the SUMER and UVCS instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in July 1995. In October 1993 a fast track program to build and characterize detectors and detector control electronics was initiated. We present the detector system design for the SOHO UVCS and SUMER detector programs, and results from the detector test program. Two deliverable detectors have been built at this point, a demonstration model for UVCS, and the flight Ly alpha detector for UVCS, both of which are to be delivered in the next few weeks. Test results have also been obtained with one other demonstration detector system. The detector format is 26mm x 9mm, with 1024 x 360 digitized pixels, using a low resistance Z stack of microchannel plates (MCP's) and a multilayer cross delay line anode (XDL). This configuration provides gains of approximately 2 x 10(exp 7) with good pulse height distributions (less than 50% FWHM) under uniform flood illumination, and background levels typical for this configuration (approximately 0.6 event cm (exp -2)sec(exp -1)). Local counting rates up to about 400 events/pixel/sec have been achieved with no degradation of the MCP gain. The detector and event encoding electronics achieves about 25 millimeter FVHM with good linearity (plus or minus approximately 1 pixel) and is stable to high global counting rates (greater than 4 x 10(exp 5) events sec(exp -1)). Flat field images are dominated by MCP fixed pattern noise and are stable, but the MCP multifiber modulation usually expected is uncharacteristically absent. The detector and electronics have also successfully passed both thermal vacuum and vibration tests.

Seigmund, O. H. W.↗

Pulse pile-up in hard X-ray detector systems

When pulse-height spectra are measured by a nuclear detection system at high counting rates, the probability that two or more pulses will arrive within the resolving time of the system is significant. This phenomenon, pulse pile-up, distorts the pulse-height spectrum and must be considered in the interpretation of spectra taken at high counting rates. A computational technique for the simulation of pile-up is developed. The model is examined in the three regimes where (1) the time between pulses is long compared to the detector-system resolving time, (2) the time between pulses is comparable to the resolving time, and (3) many pulses occur within the resolving time. The technique is used to model the solar hard X-ray experiment on the OSO-7 satellite; comparison of the model with data taken during three large flares shows excellent agreement. The paper also describes rule-of-thumb tests for pile-up and identifies the important detector design factors for minimizing pile-up, i.e., thick entrance windows and short resolving times in the system electronics.

Datlowe, D. W.↗

Single-Photon Counting Detector Scalability for High Photon Efficiency Optical Communications Links

For high photon-efficiency deep space or low power optical communications links, such as the Orion Artemis-2 Optical Communications System (O2O) project, the received optical signal is attenuated to the extent that single- photon detectors are required. For direct-detection receivers operating at 1.55 µm wavelength, single-photon detectors including Geiger-mode InGaAs avalanche photon diodes (APDs), and in particular superconducting nanowire single-photon detectors (SNSPDs) offer the highest sensitivity and fastest detection speeds. However, these photon detectors exhibit a recovery time between registered input pulses, effectively reducing the detection efficiency over the recovery interval, resulting in missed photon detections, reduced count rate, and ultimately limiting the achievable data rate. A method to overcome this limitation is to divide the received optical signal into multiple detectors in parallel. Here we analyze this approach for a receiver designed to receive a high photon efficiency serially concatenated pulse position modulation (SCPPM) input waveform. From measured count rate and efficiency data using commercial SNSPDs, we apply a model from which we determine the effective detection efficiency, or blocking loss, for different input signal rates. We analyze the scalability of adding detectors in parallel for different modulation orders and background levels to achieve desired data rates. Finally we show tradeoffs between the number of detectors and the required received optical power, useful for real link design considerations.

Vyhnalek, Brian E.↗

Long-term modulation of galactic cosmic radiation and its model for space exploration

As the human exploration of space has received new attention in the United States, studies find that exposure to space radiation could adversely impact the mission design. Galactic Cosmic Radiation (GCR), with its very wide range of charges and energies, is particularly important for a mission to Mars, because it imposes a stiff mass penalty for spacecraft shielding. Dose equivalent versus shielding thickness calculations, show a rapid initial drop on exposure with thickness, but an asymptotic behavior at a higher shielding thickness. Uncertainties in the radiobiology are largely unknown. For a fixed radiation risk, this leads to large uncertainties in shielding thickness for small uncertainties in estimated dose. In this paper we investigate the application of steady-state, spherically-symmetric diffusion-convection theory of solar modulation to individual measurements of differential energy spectra from 1954 to 1989 in order to estimate the diffusion coefficient, kappa(r,t), as a function of time. We have correlated the diffusion coefficient to the Climax neutron monitor rates and show that, if the diffusion coefficient can be separated into independent functions of space and time: kappa(r,t)=K(t) k(sub 0) beta Pk(sub 1) (r), where beta is the particle velocity and P the rigidity, then (i) The time dependent quantity 1/K(t), which is proportional to the deceleration potential, phi(r,t), is linearly related to the Climax neutron monitor counting rate. (ii) The coefficients obtained from hydrogen or helium intensity measurements are the same. (iii) There are different correlation functions for odd and even solar cycles. (iv) The correlation function for the Climax neutron monitor counting rate for given time, t, can be used to estimate mean deceleration parameter phi(t) to within +/- 15% with 90% confidence. We have shown that k(r,t) determined from hydrogen and/or helium data, can be used to fit the oxygen and iron differential energy spectra with a root mean square error of about +/- 10%, and essentially independent of the particle charge or energy. We have also examined the ion chamber and C-14 measurements which allow the analysis to be extended from the year 1906 to 1990. Using this model we have defined reference GCR spectra at solar minimum and solar maximum. These can be used for space exploration studies and provide a quantitative estimate of the error in dose due to changes in GCR intensities.

Badhwan, G. D.↗

Transition-Edge Sensor Pixel Parameter Design of the Microcalorimeter Array for the X-Ray Integral Field Unit on Athena

The focal plane of the X-ray integral field unit (X-IFU) for ESA's Athena X-ray observatory will consist of approximately 4000 transition edge sensor (TES) x-ray microcalorimeters optimized for the energy range of 0.2 to 12 kiloelectronvolts. The instrument will provide unprecedented spectral resolution of approximately 2.5 electronvolts at energies of up to 7 kiloelectronvolts and will accommodate photon fluxes of 1 milliCrab (90 counts per second) for point source observations. The baseline configuration is a uniform large pixel array (LPA) of 4.28 arcseconds pixels that is read out using frequency domain multiplexing (FDM). However, an alternative configuration under study incorporates an 18 by × 18 small pixel array (SPA) of 2 arcseconds pixels in the central approximately 36 arcseconds region. This hybrid array configuration could be designed to accommodate higher fluxes of up to 10 milliCrabs (900 counts per second) or alternately for improved spectral performance (less than 1.5 electronvolts) at low count-rates. In this paper we report on the TES pixel designs that are being optimized to meet these proposed LPA and SPA configurations. In particular we describe details of how important TES parameters are chosen to meet the specific mission criteria such as energy resolution, count-rate and quantum efficiency, and highlight performance trade-offs between designs. The basis of the pixel parameter selection is discussed in the context of existing TES arrays that are being developed for solar and x-ray astronomy applications. We describe the latest results on DC biased diagnostic arrays as well as large format kilo-pixel arrays and discuss the technical challenges associated with integrating different array types on to a single detector die.

Smith, S. J.↗

Lunar orbital gamma ray measurements from Apollo 15 and Apollo 16.

Examination of the data obtained by gamma-ray spectrometers on the Apollo 15 and Apollo 16 spacecraft has been carried out in part by summing up broad regions of the energy spectrum. The most instructive of these energy regions is 0.55 to 2.75 MeV, where the difference in count rates observed can be accounted for mainly by variations in the Th, U, and K content of the surface layers. The highest values are found in Mare Imbrium and Oceanus Procellarum, where a good deal of local variation is observed. By contrast, little increase is seen in the eastern maria surveyed compared with count rates in highland areas. The broad highland regions are low in radioactivity, but there is a measurable rise near the southernmost latitude on the far side. In addition to the radioactive lines, gamma-ray lines which can be ascribed to O, Si, Fe, Mg, and Al have been identified.

Arnold, J. R.↗

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors↗

The soft X-ray turnoff of Nova Muscae 1983

Nova GQ Muscae 1983 was detected by ROSAT as a luminous 'supersoft' X-ray source in 1992, nearly a decade after outburst. Further, this is the only classical postnova known to have maintained constant luminosity on a timescale predicted by theoretical models. Follow-up observations were made with the ROSAT position-sensitive proportional counter in 1993 January and September, and complemented with B-band photometry taken in 1993 January. By 1993 January, the X-ray count rate had declined by a factor of 17, while there was neither an appreciable decrease in the optical magnitude nor a change in the amplitude of modulation. In 1993 September the soft X-ray flux was below the ROSAT threshold limit, implying a decrease of a factor greater than or equal to 30 in the count rate. This decline can be interpreted by the turnoff of nuclear processes due to the complete consumption of the residual hydrogen-rich envelope. However, the optical luminosity of the system is not simply coupled to the X-ray luminosity (e.g., through reprocessing).

Shanley, L.↗

Detector noise statistics in the non-linear regime

The statistical behavior of an idealized linear detector in the presence of threshold and saturation levels is examined. It is assumed that the noise is governed by the statistical fluctuations in the number of photons emitted by the source during an exposure. Since physical detectors cannot have infinite dynamic range, our model illustrates that all devices have non-linear regimes, particularly at high count rates. The primary effect is a decrease in the statistical variance about the mean signal due to a portion of the expected noise distribution being removed via clipping. Higher order statistical moments are also examined, in particular, skewness and kurtosis. In principle, the expected distortion in the detector noise characteristics can be calibrated using flatfield observations with count rates matched to the observations. For this purpose, some basic statistical methods that utilize Fourier analysis techniques are described.

Shopbell, P. L.↗

Calculations for Calibration of a Mass Spectrometer

A computer program performs calculations to calibrate a quadrupole mass spectrometer in an instrumentation system for identifying trace amounts of organic chemicals in air. In the operation of the mass spectrometer, the mass-to-charge ratio (m/z) of ions being counted at a given instant of time is a function of the instantaneous value of a repeating ramp voltage waveform applied to electrodes. The count rate as a function of time can be converted to an m/z spectrum (equivalent to a mass spectrum for singly charged ions), provided that a calibration of m/z is available. The present computer program can perform the calibration in either or both of two ways: (1) Following a data-based approach, it can utilize the count-rate peaks and the times thereof measured when fed with air containing known organic compounds. (2) It can utilize a theoretical proportionality between the instantaneous m/z and the instantaneous value of an oscillating applied voltage. The program can also estimate the error of the calibration performed by the data-based approach. If calibrations are performed in both ways, then the results can be compared to obtain further estimates of errors.

Lee, Seungwon↗

Particle emission from artificial cometary materials

During KOSI (comet simulation) experiments, mineral-ice mixtures are observed in simulated space conditions. Emission of ice-/dust particles from the sample surface is observed by means of different devices. The particle trajectories are recorded with a video system. In the following analysis we extracted the parameters: particle count rate, spatial distribution of starting points on the sample surface, and elevation angle and particle velocity at distances up to 5 cm from the sample surface. Different kinds of detectors are mounted on a frame in front of the sample to register the emitted particles and to collect their dust residues. By means of these instruments the particle count rates, the particle sizes and the composition of the particles can be correlated. The results are related to the gas flux density and the temperature on the sample surface during the insolation period. The particle emission is interpreted in terms of phenomena on the sample surface, e.g., formation of a dust mantle.

Koelzer, Gabriele↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Multifunctional Superconducting Nanowire Quantum Sensors

Superconducting nanowire single-photon detectors (SNSPDs) offer high-quantum-efficiency and low-dark-count-rate single-photon detection. In a growing number of cases, large magnetic fields are being incorporated into quantum microscopes, nanophotonic devices, and sensors for nuclear and high-energy physics that rely on SNSPDs, but superconducting devices generally perform poorly in large magnetic fields. Here, we demonstrate robust performance of amorphous SNSPDs in magnetic fields of up to ±6 T with a negligible dark-count rate and unchanged quantum efficiency at typical bias currents. Critically, we also show that the SNSPD can be used as a magnetometer with a sensitivity of better than 100μT/√Hz and as a thermometer with a sensitivity of 20μK/√Hz at 1 K. Thus, a single-photon detector integrated into a quantum device can be used as a multifunctional quantum sensor capable of describing the temperature and magnetic field on chip simply by varying the bias current to change the operating modality from single-photon detection to thermometry or magnetometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate contrast determination for X-ray speckle visibility spectroscopy

X-ray speckle visibility spectroscopy using X-ray free-electron lasers has long been proposed as a probe of fast dynamics in noncrystalline materials. In this paper, numerical modeling is presented to show how the data interpretation of visibility spectroscopy can be impacted by the nonidealities of real-life X-ray detectors. Using simulated detector data, this work provides a detailed analysis of the systematic errors of several contrast extraction algorithms in the context of low-count-rate X-ray speckle visibility spectroscopy and their origins are discussed. Here, it was found that the finite detector charge cloud and pixel size lead to an unavoidable `degeneracy' in photon position determination, and that the contrasts extracted using different algorithms can all be corrected by a simple linear model. The results suggest that experimental calibration of the correction coefficient at the count rate of interest is possible and essential. This allows computationally lightweight algorithms to be implemented for on-the-fly analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗