Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT images”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

PHASE: Personalized Head-based Automatic Simulation for Electromagnetic properties in 7T MRI

Accurate and individualized human head models are becoming increasingly important for electromagnetic (EM) simulations. These simulations depend on precise anatomical representations to realistically model electric and magnetic field distributions, particularly when evaluating Specific Absorption Rate (SAR) within safety guidelines. State of the art simulations use the Virtual Population due to limited public resources and the impracticality of manually annotating patient data at scale. Here, this paper introduces Personalized Head-based Automatic Simulation for EM properties (PHASE), an automated open-source toolbox that generates high-resolution, patient-specific head models for EM simulations using paired T1-weighted (T1w) magnetic resonance imaging (MRI) and computed tomography (CT) scans with 14 tissue labels. To evaluate the performance of PHASE models, we conduct semi-automated segmentation and EM simulations on 15 real human patients, serving as the gold standard reference. The PHASE model achieved comparable global SAR and localized SAR averaged over 10 grams of tissue (SAR-10g), demonstrating its potential as a promising tool for generating large-scale human model datasets in the future. The code and models of PHASE toolbox have been made publicly available: https://github.com/hrlblab/PHASE.

Deep learning↗

Biomedical Integration of Metal–Organic Frameworks

Metal–organic frameworks (MOFs) have recently been demonstrated to be excellent platforms for biomedical applications. On account of their porous nature and modular structure, MOFs have served as bioactive-compound carriers, cell-imaging materials, and therapeutic agents. MOF cavities allow the encapsulation of a variety of guest molecules, facilitating controllable drug release and optical imaging. The metal components of MOFs make them suitable for magnetic resonance imaging (MRI) and computed tomography (CT). Further, MOF-embedded therapeutic agents have demonstrated promise in photodynamic and photothermal therapies. In this review, we describe several advanced examples that utilize MOFs in these cutting-edge applications. Investigation of the relationship between their structure and designated application will enable future, informed exploration of MOFs for biomedical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time High-resolution X-Ray Computed Tomography

Computed Tomography (CT) serves as a key imaging technology that relies on computationally intensive filtering and back-projection algorithms for 3D image reconstruction. While conventional high-resolution image reconstruction (> 2K3) solutions provide quick results, they typically treat reconstruction as an offline workload to be performed remotely on large-scale HPC systems. The growing demand for post-construction AI-driven analytics and the need for real-time adjustments call for high-resolution reconstruction solutions that are feasible on local computing resources, i.e. a multi-GPU server at most. In this paper, we propose a novel approach that utilizes Tensor Cores to optimize image reconstruction without sacrificing precision. We also introduce a framework designed to enable real-time execution of end-to-end distributed image reconstruction in a multi-GPU environment. Evaluations conducted on a single Nvidia A100 and H100 GPU show performance improvements of 1.91 × and 2.15 × compared to highly optimized production libraries. Furthermore, our framework, when deployed on 8-card Nvidia A100 GPU system, demonstrates the ability to reconstruct real-world datasets into 20483 volumes (32 GB) in slightly more than one minute and 40963 volumes (256 GB) in 7 minutes.

Wu, Du↗

Chemo–mechanical properties of carbon fiber reinforced geopolymer interphase

Geopolymers, as a potentially environmentally friendly alternative to Portland cement, are increasingly attracting attention in the construction industry. Various methods have been applied for customizing the properties of geopolymers and improving their commercial viability. One of the promising methods for refining the properties of geopolymers such as their toughness is the use of short fibers. The effectiveness of a high-strength short fiber in the geopolymer matrix is largely dependent on the interfacial bonding between the fiber and its surrounding matrix. While the importance of this interfacial chemistry is highlighted in the literature, the characteristics of this bonding structure have not been fully understood. In this paper, we aim to investigate the bonding mechanism between the carbon fiber and metakaolin-based geopolymer matrix. For the first time, the existence and nature of the chemical bonding at the interfacial region (interphase) between carbon fiber and geopolymer matrix has been revealed. X-ray pair distribution function computed tomography (PDF-CT), field emission-scanning electron microscopy imaging, and nanoindentation techniques are employed to discern the chemo-mechanical properties of the interphase. PDF-CT results show the emergence of a new atom-atom correlation at the interfacial region (around 1.82 angstrom). This correlation is a characteristic of interfacial bonding between the fiber and its surrounding matrix, where the existence of chemical linkages (potentially Al-V-O-C) between fibers and the matrix contributes to the adhesion between the two constituents making up the composite. Due to such chemical bonding, the nanomechanical properties of the interfacial region fall between that of the carbon fiber and geopolymer. The combination of advanced techniques is proved useful for enhancing our understanding of the interfacial chemistry between fibers and the binding matrix. This level of knowledge facilitates the engineering of composite systems through the manipulation of their nanostructure.

36 MATERIALS SCIENCE↗

Water Imbibition and Oil Recovery in Shale: Dynamics and Mechanisms Using Integrated Centimeter-to-Nanometer-Scale Imaging

Water imbibition, and the associated oil displacement, is an important process in shale oil reservoirs after hydraulic fracturing and in water-based enhanced oil recovery (EOR). Current techniques for water imbibition measurement are mostly “black-box”-type methods. A more explicit understanding of the water imbibition/oil recovery dynamics and geological controls is in demand. In this paper, a multiscale imaging technique that covers centimeter to nanometer scale (i.e., core to pore scale), integrating neutron radiography, microcomputed tomography (micro-CT), and scanning electron microscope (SEM) is applied to investigate the water imbibition depth and rate and the cause of heterogeneity of imbibition in shale samples. The dynamic processes of water imbibition in the 1-in. (25.4-mm) core sample were explicitly demonstrated, and the imbibition along the matrix and imbibition through microfractures are distinguished through neutron radiography image analysis. The causes of observed imbibition heterogeneity were further investigated through micro-CT and SEM image analysis for 1.5-mm diameter miniplug samples from different laminas of the 1-in. core samples. Imbibition depth and rate were calculated on the basis of image analysis as well. Estimation of oil recovery through water imbibition in shale matrix was performed for an example shale field. Here this innovative and integrated multiscale imaging technique provides a “white/gray-box” method to understand water imbibition and water-oil displacement in shale. The wide span of the length scale (from centimeter to nanometer) of this technique enables a more comprehensive, accurate, and specific understanding of both the core-scale dynamics and pore-scale mechanisms of water imbibition, oil recovery, and matrix-fracture interaction.

04 OIL SHALES AND TAR SANDS↗

DETERMINATION OF STRUT QUALITY FACTORS IN ADDITIVELY MANUFACTURED LATTICES USING IN-SITU COMPRESSION TESTING µ-CT

In response to the need for an automated, commercial method to qualify additively manufactured (AM) lattice components, an experiment was conducted to evaluate the effects of defective lattice struts on the structural compression strength. Lattice samples with known defective or missing struts were compressed using a Deben CT5000RT and imaged using xray µ-CT. The compressive force and x-ray computed tomography results were compared to defect free standards to evaluate the impact of each defect type on the overall structure’s compressive strength. This analysis will allow for simplifications to Finite Element Analysis (FEA) on AM parts without sacrificing model fidelity. Understanding the contribution of each defect type and severity will also better inform non-destructive evaluation (NDE) personnel of the inspection parameters necessary to detect the smallest feature of importance.

Dinova, Vincent A.↗

Automated CT registration, segmentation, and quantification (AutoCT) v1.0

Processing and analyzing brain imaging is crucial in both scientific development and clinical field. In this software package, we build a pipeline that integrates automatic registration, segmentation, and quantitative analysis for subjects' CT scans. Leveraging diffeomorphic transformations, we enable optimized forward and inverse mappings between an image and the reference. Furthermore, we extract localized features from deformation field based on an online template process, which advances statistical learning downstream. The created templates, atlas as well as our methods provide the brain imaging community tools for AI implementations.

Essiari, Abdelilah↗

Automated CT registration, segmentation, and quantification (AutoCT) v1.1

Processing and analyzing brain imaging is crucial in both scientific development and clinical field. In this software package, we build a pipeline that integrates automatic registration, segmentation, and quantitative analysis for subjects' CT scans. Leveraging diffeomorphic transofrmations, we enable optimized forward and inverse mappings between an image and the reference. Furthermore, we extract localized features from deformation field based on an online template process, which advances statistical learning downstream. The created templates, atlas as well as our methods provide the brain imaging community tools for AI implementations

Bai, Zhe↗

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN↗

Model and Standard Operating Procedures Supporting Signal Variation Flow Graph Analysis

This document will describe the principles of the Signal Variation Flow Technique, and the uncertainty models generated using it. We focus on the capture of the variation between the ideal signal and the measured signal. The ideal signal is defined to represent the signal output of a system whose full state behavior is known, with no variation in environment or during operation, and whose photons trajectories are not modified by the object. A CT uncertainty analysis is the result of two main steps. First, the radiography regime extends from the source to the collected image, which is 2D in the case of standard CT. This maps all upstream uncertainties into the variation observed on the radiograph and captures all variation in the physical domain. Second, the reconstruction regime extends from the captured images to the reconstructed 3D image. This regime is purely in the mathematical domain and corrects reconstruction algorithm artifacts/anomalies. The present work focuses on building the model through the radiography regime. The reconstruction regime is expected to be largely a study of algorithmic sensitivity, requiring the definition of a range of standardized tests through which the algorithms would be run. Radiographic variation would then be mapped through reconstruction sensitivities to predict the signal variation in the final image. An incomplete list for the reconstructed image variation output basis includes voxel density, edge blur and length variation, in analogous fashion to the basis functions presented in this work. The signal variation occurs in several forms at the radiograph. These forms are gathered into a complete basis set of functions describing all variation on the radiograph. The scale of each basis function is calculated independently via a specific SVFG. This includes 0D pixel noise (0DI), 0D energy noise (0DE), 1D blur (1DB), 1D length (1DL) or 2D position (2DP). These models are orthogonal in that they each explore a space in the signal variation domain that cannot be reached by the other basis functions. The variation basis functions, and associated SVFG models are split by output dimensionality, a term loosely used for categorization, and explained further below.

42 ENGINEERING↗

Oxidation and microstructure of SiC f /SiC composites in moist air up to 1600°C by X‐ray tomographic characterization

Abstract SiC f /SiC composites that possess PyC or BN interface layers were fabricated and then oxidized in moist air at 1000, 1200, 1400, and 1600°C. High‐resolution CT was used for capturing 3D images and quantifying the SiC phase, mesophase, and voids. The oxidation behavior and microstructural evolution of SiC f /SiC with PyC or BN interface are discussed in this study. The microstructure of the SiC f /SiC with a PyC layer was seriously damaged in moist air at high temperature, whereas the BN interface layer enhanced the oxidation resistance of the SiC f /SiC. These results are also confirmed by using XRD, oxidation mass gain, tensile testing, and SEM measurements. The results of the oxidation behavior and microstructural evolution for SiC f /SiC oxidized in dry air are also compared with the results of this study. Comparing the SiC f /SiC with a PyC interface layer, the composite with a BN interface layer oxidized in moist air exhibits a high void growth rate and a low SiO 2 grain growth rate from 1000 to 1600°C. This work will provide guidance for predicting the service life of SiC f /SiC for multiscale damage rate models of materials at a local scale and will also provide guidance on the life service design of SiC f /SiC materials.

Lu, Zilong↗

Physics guided machine learning for multi-material decomposition of tissues from dual-energy CT scans of simulated breast models with calcifications

We introduce a physics guided data-driven method for image-based multi-material decomposition for dual-energy computed tomography (CT) scans. The method is demonstrated for CT scans of virtual human phantoms containing more than two types of tissues. The method is a physics-driven supervised learning technique. We take advantage of the mass attenuation coefficient of dense materials compared to that of muscle tissues to perform a preliminary extraction of the dense material from the images using unsupervised methods. We then perform supervised deep learning on the images processed by the extracted dense material to obtain the final multi-material tissue map. The method is demonstrated on simulated breast models with calcifications as the dense material placed amongst the muscle tissues. The physics-guided machine learning method accurately decomposes the various tissues from input images, achieving a normalized root-mean-squared error of 2.75%.

Gopalakrishnan Meena, Murali↗

Permeability Prediction Using Vision Transformers

Accurate permeability predictions remain pivotal for understanding fluid flow in porous media, influencing crucial operations across petroleum engineering, hydrogeology, and related fields. Traditional approaches, while robust, often grapple with the inherent heterogeneity of reservoir rocks. With the advent of deep learning, convolutional neural networks (CNNs) have emerged as potent tools in image-based permeability estimation, capitalizing on micro-CT scans and digital rock imagery. This paper introduces a novel paradigm, employing vision transformers (ViTs)—a recent advancement in computer vision—for this crucial task. ViTs, which segment images into fixed-sized patches and process them through transformer architectures, present a promising alternative to CNNs. We present a methodology for implementing ViTs for permeability prediction, its results on diverse rock samples, and a comparison against conventional CNNs. The prediction results suggest that, with adequate training data, ViTs can match or surpass the predictive accuracy of CNNs, especially in rocks exhibiting significant heterogeneity. This study underscores the potential of ViTs as an innovative tool in permeability prediction, paving the way for further research and integration into mainstream reservoir characterization workflows.

58 GEOSCIENCES↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Microbial Community Characteristics Largely Unaffected by X-Ray Computed Tomography of Sediment Cores

X-ray computed tomography (CT) scanning is used to study the physical characteristics of soil and sediment cores, allowing scientists to analyze stratigraphy without destroying core integrity. Microbiologists often work with geologists to understand the microbial properties in such cores; however, we do not know whether CT scanning alters microbial DNA such that DNA sequencing, a common method of community characterization, changes as a result of X-ray exposure. Our objective was to determine whether CT scanning affects the estimates of the composition of microbial communities that exist in cores. Sediment cores were extracted from a salt marsh and then submitted for CT scanning. We observed a minimal effect of CT scanning on microbial community composition in the sediment cores either when the cores were examined shortly after recovery from the field or after the cores had been stored for several weeks. In contrast, properties such as sediment layer and marsh location did affect microbial community structure. While we observed that CT scanning did not alter microbial community composition as a whole, we identified a few amplicon sequence variants (13 out of 7,037) that showed differential abundance patterns between scanned and unscanned samples among paired sample sets. Our overall conclusion is that the CT-scanning conditions typically used to obtain images for geological core characterization do not significantly alter microbial community structure. We stress that minimizing core exposure to X-rays is important if cores are to be studied for biological properties. Future investigations might consider variables, such as the length and energy of radiation exposure, the volume of the core, or the degree, to which microbial communities are stressed as important factors in assessing the impact of X-rays on microbes in geological cores.

59 BASIC BIOLOGICAL SCIENCES↗

MemXCT: Design, Optimization, Scaling, and Reproducibility of X-Ray Tomography Imaging

Here, this work extends our previous research entitled "MemXCT: Memory-centric X-ray CT Reconstruction with Massive Parallelization" that was originally published at SC19 conference (Hidayetoglu et al., 2019) with reproducibility of the computational imaging performance. X-ray computed tomography (XCT) is regularly used at synchrotron light sources to study the internal morphology of materials at high resolution. However, experimental constraints, such as radiation sensitivity, can result in noisy or undersampled measurements. Further, depending on the resolution, sample size and data acquisition rates, the resulting noisy dataset can be in the order of terabytes. Advanced iterative reconstruction techniques can produce high-quality images from noisy measurements, but their computational requirements have made their use an exception rather than the rule. We propose a novel memory-centric approach that avoids redundant computations at the expense of additional memory complexity. We develop a memory-centric iterative reconstruction system, MemXCT, that uses an optimized SpMV implementation with two-level pseudo-Hilbert ordering and multi-stage input buffering. We evaluate MemXCT on various supercomputer architectures involving KNL and GPU. MemXCT can reconstruct a large (11Kx11K) mouse brain tomogram in 10 seconds using 4096 KNL nodes (256K cores). The results presented in our original article at the SC19 were based on large-scale supercomputing resources. The MemXCT application was selected for the Student Cluster Competition (SCC) Reproducibility Challenge and evaluated on a variety of cloud computing resources by universities around the world in the SC20 conference. We summarize the results of the top-ranked SCC Reproducibility Challenge teams and identify the most pertinent measures for ensuring the reproducibility of our experiments in this article.

47 OTHER INSTRUMENTATION↗

Phase-contrast 3D tomography of HeLa cells grown in PLLA polymer electrospun scaffolds using synchrotron X-rays

Advanced imaging is useful for understanding the three-dimensional (3D) growth of cells. X-ray tomography serves as a powerful noninvasive, nondestructive technique that can fulfill these purposes by providing information about cell growth within 3D platforms. There are a limited number of studies taking advantage of synchrotron X-rays, which provides a large field of view and suitable resolution to image cells within specific biomaterials. In this study, X-ray synchrotron radiation microtomography at Diamond Light Source and advanced image processing were used to investigate cellular infiltration of HeLa cells within poly L-lactide (PLLA) scaffolds. This study demonstrates that synchrotron X-rays using phase contrast is a useful method to understand the 3D growth of cells in PLLA electrospun scaffolds. Two different fiber diameter (2 and 4 µm) scaffolds with different pore sizes, grown over 2, 5 and 8 days in vitro , were examined for infiltration and cell connectivity. After performing visualization by segmentation of the cells from the fibers, the results clearly show deeper cell growth and higher cellular interconnectivity in the 4 µm fiber diameter scaffold. Finally, this indicates the potential for using such 3D technology to study cell–scaffold interactions for future medical use.

3D culture↗