Direct current mode neutron detection, investigation of polarization effect on 500µm single crystal CVD diamond detector, and depolarization techniques
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Friction and wear behavior of ion-beam-deposited diamondlike carbon (DLC) films coated on chemical-vapor-deposited (CVD), fine-grain diamond coatings were examined in ultrahigh vacuum, dry nitrogen, and humid air environments. The DLC films were produced by the direct impact of an ion beam (composed of a 3:17 mixture of Ar and CH4) at ion energies of 1500 and 700 eV and an RF power of 99 W. Sliding friction experiments were conducted with hemispherical CVD diamond pins sliding on four different carbon-base coating systems: DLC films on CVD diamond; DLC films on silicon; as-deposited, fine-grain CVD diamond; and carbon-ion-implanted, fine-grain CVD diamond on silicon. Results indicate that in ultrahigh vacuum the ion-beam-deposited DLC films on fine-grain CVD diamond (similar to the ion-implanted CVD diamond) greatly decrease both the friction and wear of fine-grain CVD diamond films and provide solid lubrication. In dry nitrogen and in humid air, ion-beam-deposited DLC films on fine-grain CVD diamond films also had a low steady-state coefficient of friction and a low wear rate. These tribological performance benefits, coupled with a wider range of coating thicknesses, led to longer endurance life and improved wear resistance for the DLC deposited on fine-grain CVD diamond in comparison to the ion-implanted diamond films. Thus, DLC deposited on fine-grain CVD diamond films can be an effective wear-resistant, lubricating coating regardless of environment.
The carbon vapor deposition (CVD) reactor is a technology developed by Honeywell Aerospace to convert methane, at high temperatures, into hydrogen and solid carbon. This element is coupled with a Sabatier reactor to support a closed-loop environmental control and life support system with the aim of achieving nearly complete oxygen recovery (> 95%). Initial open-loop, brassboard CVD reactor tests and simulations have shown the CVD’s ability to achieve moderately high methane conversion and high hydrogen selectivity. However, in an integrated system, additional deficiencies are expected due to recycling of unreacted or extraneous species from the Sabatier reactor (e.g., carbon dioxide, hydrogen, water) and CVD reactor (e.g., hydrocarbons, methane, etc.). Sabatier and CVD reactor models were integrated and simulated to predict potential impacts to individual reactors’ and the overall system’s performance. The simulations showed that increasing the recycle of the CVD effluent hydrogen combined with decreasing the system inlet hydrogen flow rate (i.e., drawing a stoichiometric flow rate from an electrolyzer) can lead to an oxygen recovery of > 95%. However, system integration comes at a detriment to the individual reactors. The simulations show the initial conversion from the integrated system (Sabatier = 87% and CVD = 59%) to be lower than the standalone systems (Sabatier = 91% and CVD = 69%). Furthermore, transient simulations show substrate densification, leading to worsening methane conversion coupled with increasing acetylene production, which is commensurate with soot formation. Simulations predict a shortening of the maintenance interval (i.e., time until CVD methane conversion drops below 50%) in the integrated system, which would increase the consumable substrate mass. These analyses highlight the importance of long-duration, integrated tests to corroborate these findings as well as suggest potential modifications (e.g., intermediate gas separations) to improve performance.
Fluorescent nanodiamonds (FNDs) containing negatively charged nitrogen-vacancy (NV − ) centers are vital for many emerging quantum sensing applications from magnetometry to intracellular sensing in biology. However, developing a scalable fabrication method for FNDs hosting color centers with consistent bulk-like photoluminescence (PL) and spin coherence properties remains a highly desired but unrealized goal. Here, we investigate optimized ball milling of single-crystal diamonds produced via chemical vapor deposition (CVD) and containing 2 ppm of substitutional nitrogen and 0.3 ppm of NV − to achieve this goal. The NV charge state, PL lifetime, and spin properties of bulk CVD diamond samples are directly compared to milled CVD FNDs and commercial high-pressure high-temperature (HPHT) FNDs. We find that on average, the relative contribution of the NV − charge state to the total NV PL is lower and the NV PL lifetime is longer in CVD FNDs compared to HPHT FNDs, both likely due to the lower N s 0 concentration in CVD FNDs. The CVD bulk and CVD FNDs on average show similar average T 1 spin relaxation times of 3.2 ± 0.7 ms and 4.7 ± 1.6 ms, respectively, compared to 0.17 ± 0.01 ms for commercial HPHT FNDs. Our results demonstrate that ball milling of CVD diamonds enables the large-scale fabrication of NV ensembles in FNDs with bulk-like T 1 spin relaxation properties.
This project is to develop M (x) -N-C catalysts with dense multiple metal center (MMC) sites to meet the DOE 2025 activity target of 0.044 mA/cm 2 at 0.9 V IR-free ., as well as other goals such as durability. We have made important contributions to both catalyst development and fundamental understandings of the active sites in M-N-C catalysts in this project. We successfully made M (x) -N-C catalysts with some multiple metal center (MMC) sites by combining ionothermal carbonization with chemical vapor deposition (CVD). These catalysts, however, are not as active as the most active single-atom Fe-N-C catalysts made by the similar CVD process, owing likely to the low site density and the presence of inorganic Fe species such as iron carbides and nanoparticles. The most significant accomplishments we achieved in this project are: (1) we unraveled the formation pathway of Fe-N 4 sites during pyrolysis step-by-step and identified the trans-metalation mechanism, in collaboration with Deborah Myers and her colleagues at Argonne National Laboratory (ANL); (2) inspired by this finding, we pioneered the CVD synthesis of M-N-C catalysts (M = Mn, Fe, and Co), in which the Fe-N-C catalyst by CVD demonstrated an ORR activity of 33 mA/cm 2 at 0.9 V in H 2 -O 2 proton exchange membrane fuel cells (PEMFCs), very close to the ultimate goal of 35 mA/cm 2 of our project. This catalyst is the first Fe-N-C catalyst that contains only D1 sites without the D2 sites; whereas D1 and D2 sites have been always identified by Mossbauer in previous Fe-N-C catalysts. This finding helps to understand what the D1 and D2 sites are and their roles in catalyzing the ORR. (3) by improving the mass transport of the carbon matrix prior to the CVD process, the revised Fe-N-C catalyst made by CVD delivered a maximum power density of 0.53 W/cm 2 in H 2 -air PEMFCs. The improvement strategy was partly inspired by the computational modeling work by Adam Weber from LBNL, the Co-PI of this project, by developing, coding, and exercising a continuum level model of transport phenomena within a PGM-free catalyst layer. The model demonstrated that local resistances combined with limited site density of the PGM-free catalyst can result in limiting currents and poor polarization performance. The model also gave design guidance for impact of ECSA and overall catalyst-layer thickness. However, both Fe-N-C and Co-N-C catalysts developed by CVD showed poor durability in PEMFCS, in comparison with the traditional M-N-C catalysts synthesized via regular pyrolysis process. Consequently, we did not achieve the proposed durability targets. Despite so, we believe the FeNC-CVD catalysts with the poor durability and D1 sites only provides an excellent platform to understand the degradation mechanism of Fe-N-C in PEMFCs, the most important challenge in the development of M-N-C catalysts.
The tribological properties of chemical-vapor-deposited (CVD) diamond films vary with the environment, possessing a Jekyll-and-Hyde character. CVD diamond has low coefficient of friction and high wear resistance in air but high coefficient of friction and low wear resistance in vacuum. Improving the tribological functionality of materials (such as achieving low friction and good wear resistance) was an aim of this investigation. Three studies on the surface design, surface engineering, and tribology of CVD diamond have shown that its friction and wear are significantly reduced in ultrahigh vacuum. The main criteria for judging whether diamond films are an effective wear-resistant, self-lubricating material were coefficient of friction and wear rate, which must be less than 0.1 and on the order of 10(exp 6) cu mm/N(dot)m, respectively. In the first study the presence of a thin film (less than 1 micron thick) of amorphous, nondiamond carbon (hydrogenated carbon, also called diamondlike carbon or DLC) on CVD diamond greatly decreased the coefficient of friction and the wear rate. Therefore, a thin DLC film on CVD diamond can be an effective wear-resistant, lubricating coating in ultrahigh vacuum. In the second study the presence of an amorphous, nondiamond carbon surface layer formed on CVD diamond by ion implantation significantly reduced the coefficient of friction and the wear rate in ultrahigh vacuum. Therefore, such surface layers are acceptable for effective self-lubricating, wear-resistant applications of CVD diamond. In the third study CVD diamond in contact with cubic boron nitride exhibited low coefficient of friction in ultra high vacuum. Therefore, this materials combination can provide an effective self-lubricating, wear-resistant couple in ultrahigh vacuum.
The next generation of nuclear and particle physics rare-event search experiments demand structural materials combining ultra-low levels of radioactive contamination with exceptional mechanical strength. Here, this study evaluates chemical vapor deposition (CVD) nickel as a low radioactive background candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates was assayed via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution. These material assays produced measured bulk concentration of 232 Th, 238 U, and nat K at the levels of ~70 ppq, ≲100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 μ m beneath the surface, likely associated with the aluminum growth substrate. Additionally, the CVD Ni underwent tensile testing alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, heat treatment was found to reduce the tensile strength to levels comparable to standard Ni, with implications for high-temperature weld joining methods. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in surface cleaning and weld-joining techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.
The advantages and utility of chemical-vapor-deposited (CVD) diamond as an industrial ceramic can only be realized if the price and quality are right. Until recently, this technology was of interest only to the academic and basic research community. However, interest has grown because of advances made by leading CVD diamond suppliers: 1) Reduction of the cost of CVD polycrystalline diamond deposition below $5/carat ($8/sq cm); 2) Installation of production capacity; 3) Epitaxial growth of CVD single-crystal diamond. Thus, CVD diamond applications and business are an industrial reality. At present, CVD diamond is produced in the form of coatings or wafers. CVD diamond film technology offers a broader technological potential than do natural and high-pressure synthetic diamonds because size, geometry, and eventually cost will not be as limiting. Now that they are cost effective, diamond coatings - with their extreme properties - can be used in a variety of applications. Diamond coatings can improve many of the surface properties of engineering substrate materials, including erosion, corrosion, and wear resistance. Examples of actual and potential applications, from microelectromechanical systems to the wear parts of diamond coatings and related superhard coatings are described. For example, diamond coatings can be used as a chemical and mechanical barrier for the space shuttles check valves, particularly on the guide pins and seat assemblies.
Little is known about the time course of mortality reduction following smoking cessation in Asians who have smoking behaviours distinct from their Western counterparts. We evaluated the level of reduction in all-cause, cardiovascular disease (CVD) and lung cancer mortality by years since quitting smoking, in Asia. Using Cox regression, we analysed individual participant data (n = 709 151) from 16 prospective cohorts conducted in China, Japan, Korea/Singapore, and India/Bangladesh, separately by cohorts. Cohort-specific hazard ratios (HRs) were combined using a random-effects meta-analysis. During a mean follow-up of 12.0 years, 108 287 deaths were ascertained—35 658 from CVD and 7546 from lung cancer. Among Asian men, a dose-response relationship of risk reduction in deaths from all causes, CVD and lung cancer was observed with an increase in years after smoking cessation. Compared with never smokers, however, all-cause and CVD mortality among former smokers remained elevated 10–14 years after quitting [multivariable-adjusted HR (95% confidence interval (CI) = 1.25 (1.13–1.37) and 1.20 (1.02–1.41), respectively]. Lung cancer mortality stayed almost 2-fold higher than among never smokers 15–19 years after smoking cessation [1.97 (1.41–2.73)], particularly among former heavy smokers [2.62 (1.71–4.00)]. Women who quitted for ≥5 years retained a significantly elevated mortality from all causes, CVD and lung cancer. Overall patterns of the cessation-mortality associations were similar across countries. Our findings suggest that adverse effects of tobacco smoking persist for an extended time period, even for more than two decades, which is beyond the time windows defined in current clinical guidelines for risk assessment of lung cancer and CVD.
Color vision deficiency (CVD) is a decreased ability to discern between particular colors. Eight percent of genetic males and half a percent of genetic females have some form of CVD, with many in the radar community falling into this group. When presenting data on a two-dimensional plane, it is common to use colors to represent values via a colormap. Colormap choice in the radar community is influenced by the ability to highlight scientifically interesting features in data, institutional choices, and domain dominance of legacy colormaps. The problem with these current colormaps is that many do not project well for those with CVD (i.e., green next to red). In working with the CVD community to address this problem, multiple colormaps for moments such as equivalent reflectivity factor and Doppler velocity were created for users with forms of CVD such as deuteranomaly, protanomaly, protanopia, and deuteranopia using Python tools such as colorspacious and viscm. We show how these colormaps can improve interpretability for four cases: a mesoscale convective system, a pyrocumulonimbus storm, a wintertime midlatitude cyclone, and widespread storms with a large bird migration. These new radar equivalent reflectivity factor, Doppler velocity, and polarization colormaps are designed to highlight rain, frozen precipitation, nonmeteorological targets, and velocity-based items, are perceptually uniform, and are visually friendly for those with CVD.
This chapter describes three studies on the surface design, surface engineering, and tribology of chemical-vapor-deposited (CVD) diamond films and coatings toward wear-resistant, self-lubricating diamond films and coatings. Friction mechanisms and solid lubrication mechanisms of CVD diamond are stated. Effects of an amorphous hydrogenated carbon on CVD diamond, an amorphous, nondiamond carbon surface layer formed on CVD diamond by carbon and nitrogen ion implantation, and a materials combination of cubic boron nitride and CVD diamond on the adhesion, friction, and wear behaviors of CVD diamond in ultrahigh vacuum are described. How surface modification and the selected materials couple improved the tribological functionality of coatings, giving low coefficient of friction and good wear resistance, is explained.
Space radiation poses an increased risk for cardiovascular diseases (CVD) during and after spaceflight, that should be quantified to plan future space missions such as the flight to Mars. The radiation-induced CVD risk is evaluated using a linear no-threshold dose response excess relative risk (ERR) model, so that the risk is function of the radiation dose and of the background (i.e., non-exposed) incidence rate. The background CVD risk can be evaluated using clinical prediction models (CPMs). The first CPMs developed in the 1960’s have identified CVD risk factors such as blood pressure, diabetes, cholesterol, and smoking. In this work, the steps used to integrate the CVD risk provided by a CPM into the NASA Radiation Risk Model are described. Simulation results calculated using available data for relevant mission scenarios are also shown, and the challenges in CVD risk predictions are discussed.
Space radiation poses an increased risk for cardiovascular diseases (CVD) during and after spaceflight, that should be quantified to plan future space missions such as the flight to Mars. The radiation-induced CVD risk is evaluated using a linear no-threshold dose response excess relative risk (ERR) model, so that the risk is function of the radiation dose and of the background (i.e., non-exposed) incidence rate. The background CVD risk can be evaluated using clinical prediction models (CPMs). The first CPMs developed in the 1960’s have identified CVD risk factors such as blood pressure, diabetes, cholesterol, and smoking. In this work, the steps used to integrate the CVD risk provided by a CPM into the NASA Radiation Risk Model are described. Simulation results calculated using available data for relevant mission scenarios are also shown, and the challenges in CVD risk predictions are discussed.
Color Vision Deficiency (CVD) is a decreased ability to discern between particular colors. Eight percent of genetic males and half a percent of genetic females have some form of CVD, with many in the radar community falling into this group. When presenting data on a two-dimensional plane, it is common to use colors to represent values via a colormap. Colormap choice in the radar community is influenced by the ability to highlight scientifically interesting features in data, institutional choices, and domain dominance of legacy colormaps. The problem with these current colormaps is that many do not project well for those with CVD (i.e., green next to red). In working with the CVD community to address this problem, multiple colormaps for moments such as equivalent reflectivity factor and Doppler velocity were created for users with forms of CVD such as deuteranomaly, protanomaly, protanopia, and deuteranopia using Python tools such as colorspacious and viscm. We show how these colormaps can improve interpretability for four cases: a mesoscale convective system, a pyrocumulonimbus storm, a wintertime mid-latitude cyclone, and widespread storms with a large bird migration. These new radar equivalent reflectivity factor, Doppler velocity, and polarization colormaps are designed to highlight rain, frozen precipitation, non-meteorological targets, velocity-based items, be perceptually uniform, and visually friendly for those with CVD.
Stable isotopes δ 18 O and δ 2 H are used to infer vegetation water sources. In some studies, significant xylem water δ 2 H offsets from potential source waters have been observed. The offsets appear to be more prevalent with cryogenic vacuum distillation (CVD) of plant water. Hypothesized mechanisms for these offsets include changes during plant water uptake and transport, and methodological problems. We propose that a large portion of the offsets are due to hydrogen isotope exchange between xylem water and non-crystalline hydroxyl groups of wood cellulose and hemicellulose during CVD. We present a method for estimating the hypothesized isotopic exchange between wood tissues and water, which is the result of Rayleigh and equilibrium fractionation. To estimate the exchange, we use published wood properties for North American tree species and isotope chemical relationships as a function of moisture content, CVD temperature and water extraction efficiency. A simple model of exchange between xylem water and hydroxyl groups captures the range of observations in studies in which CVD and non-CVD methods were compared. To evaluate the model, we compared observed δ 2 H offsets (sw-excess) values from two field datasets (90°C, n = 364, and 170°C, n = 43) to δ 2 H offsets estimated with our chemical model. We found good agreement between observed and estimated δ 2 H offsets for samples extracted at 90°C (r 2 = 0.69) but not for samples extracted at 170°C (r 2 = 0.20). The offset may be eliminated by increasing the extraction temperature to 229°C or by adding a standard sufficient to raise the moisture content to >150%. A correction can also be approximated by applying a theoretical calculation based on the extraction temperature, moisture content and water extraction efficiency.