3-D Packaging: A Technology Review

Traditional electronics are assembled as a planar arrangement of components on a printed circuit board (PCB) or other type of substrate. These planar assemblies may then be plugged into a motherboard or card cage creating a volume of electronics. This architecture is common in many military and space electronic systems as well as large computer and telecommunications systems and industrial electronics. The individual PCB assemblies can be replaced if defective or for system upgrade. Some applications are constrained by the volume or the shape of the system and are not compatible with the motherboard or card cage architecture. Examples include missiles, camcorders, and digital cameras. In these systems, planar rigid-flex substrates are folded to create complex 3-D shapes. The flex circuit serves the role of motherboard, providing interconnection between the rigid boards. An example of a planar rigid - flex assembly prior to folding is shown. In both architectures, the interconnection is effectively 2-D.

Strickland, Mark↗

Effect of hindlimb unweighting on tissue blood flow in the rat

This study characterized distribution of blood flow in the rat during hindlimb unweighting (HU), and post-HU standing and exercise. The relationship between reduced hindlimb blood flow and the previously observed elevation in anaerobic metabolism observed with contractile activity in the atrophied soleus muscle was examined (Witzmann et al., 1992). Blood flow was measured during unweighting, normal standing, and running on a treadmill (15 m/min), after 15 days of HU or cage control. For another group blood flow was measured during preexercise treadmill standing and treadmill running. During unweighting, PE standing, and running no difference in soleus blood flow was observed between groups. Muscles composed mainly of fast twitch glycolytic fibers received greater blood flow during chronic unweighting. With exercise blood flow to visceral organs was reduced in control animals, a similar change was not seen in 15 day HU rats. These changes suggest a reduction in the ability of the sympathetic nervous system to distribute cardiac output after chronic HU. A reduction in blood flow to the soleus during exercise was not observed after HU and so does not explain the increased dependence of the atrophied soleus on anerobic energy production during contractile activity.

Mcdonald, K. S.↗

Rodent Habitat on ISS: Advances in Capability for Determining Spaceflight Effects on Mammalian Physiology

Rodent research is a valuable essential tool for advancing biomedical discoveries in life sciences on Earth and in space. The National Research Counsel's Decadal survey (1) emphasized the importance of expanding NASAs life sciences research to perform long duration, rodent experiments on the International Space Station (ISS). To accomplish this objective, new flight hardware, operations, and science capabilities were developed at NASA ARC to support commercial and government-sponsored research. The flight phases of two separate spaceflight missions (Rodent Research-1 and Rodent Research-2) have been completed and new capabilities are in development. The first flight experiments carrying 20 mice were launched on Sept 21, 2014 in an unmanned Dragon Capsule, SpaceX4; Rodent Research-1 was dedicated to achieving both NASA validation and CASIS science objectives, while Rodent Reesearch-2 extended the period on orbit to 60 days. Groundbased control groups (housed in flight hardware or standard cages) were maintained in environmental chambers at Kennedy Space Center. Crewmembers previously trained in animal handling transferred mice from the Transporter into Habitats under simultaneous veterinary supervision by video streaming and were deemed healthy. Health and behavior of all mice on the ISS was monitored by video feed on a daily basis, and post-flight quantitative analyses of behavior were performed. The 10 mice from RR-1 Validation (16wk old, female C57Bl6/J) ambulated freely and actively throughout the Habitat, relying heavily on their forelimbs for locomotion. The first on-orbit dissections of mice were performed successfully, and high quality RNA (RIN values>9) and liver enzyme activities were obtained, validating the quality of sample recovery. Post-flight sample analysis revealed that body weights of FLT animals did not differ from ground controls (GC) housed in the same hardware, or vivarium controls (VIV) housed in standard cages. Organ weights analyzed post-flight showed that there were no differences between FLT and GC groups in adrenal gland and spleen weights, whereas FLT thymus and liver weights exceeded those of GC. Minimal differences between the control groups (GC and VIV) were observed. In addition, Over 3,000 aliquots collected post-flight from the four groups of mice were deposited into the Ames Life Science Data Archives for the Biospecimen Sharing Program and Genelab project. New capabilities recently developed include DEXA scanning, grip strength tests and male mice. In conclusion, new capability for long duration rodent habitation of group-housed rodents was developed and includes in-flight sample collection, thus avoiding the complication of reentry. Results obtained to date reveal the possibility of striking differences between the effects of short duration vs. long duration spaceflight. This Rodent Research system enables achievement of both basic science and translational research objectives to advance human exploration of space.

Bone Loss↗

Animal research on the Space Station

The need for in-depth, long- and short-term animal experimentation in space to qualify man for long-duration space missions, and to study the effects of the absence and presence of Earth's gravity and of heavy particle radiation on the development and functioning of vertebrates is described. The major facilities required for these investigations and to be installed on the Space Station are: modular habitats for holding rodents and small primates in full bioisolation; a habitat holding facility; 1.8 and 4.0 m dia centrifuges; a multipurpose workbench; and a cage cleaner/disposal system. The design concepts, functions, and characteristics of these facilities are described.

Bonting, S. L.↗

Development of a Miniature, Two-Axis, Triple-Helmholtz-Driven Gimbal

This paper details the development of a Helmholtz-driven, 2-axis gimbal to position a flat mirror within 50 microradian (fine positioning) in a space environment. The gimbal is intended to travel on a deep space mission mounted on a miniature "rover" vehicle. The gimbal will perform both pointing and scanning functions. The goal for total mass of the gimbal was 25 grams. The primary challenge was to design and build a bearing system that would achieve the required accuracy in addition to supporting the relatively large mass of the mirror and the outer gimbal. The mechanism is subjected to 100-G loading without the aid of any additional caging mechanism. Additionally, it was desired to have the same level of accuracy during Earth-bound, 1-G testing. Due to the inherent lack of damping in a zero-G, vacuum environment; the ability of the gimbal to respond to very small amounts of input energy is paramount. Initial testing of the first prototype revealed exceedingly long damping times required even while exposed to the damping effects of air and 1-G friction. It is envisioned that fine positioning of the gimbal will be accomplished in very small steps to avoid large disturbances to the mirror. Various bearing designs, including materials, lubrication options and bearing geometry will be discussed. In addition various options for the Helmholtz coil design will be explored with specific test data given. Ground testing in the presence of 1-G was compounded by the local magnetic fields due to the "compass" effect on the gimbal. The test data will be presented and discussed. Additionally, rationale for estimating gimbal performance in a zero-G environment will be presented and discussed.

Sharif, Boz↗

Testing and validation of the microbial environment of the NASA rodent spaceflight habitat water delivery system.

Sterilized, deionized water within a closed, self-sufficient system has been used in NASA spaceflight rodent studies for several decades. Within the specialized spaceflight rodent habitat, water is delivered through a compression spring-loaded bag system to maintain positive pressure. Refill of the drinking water occurs every 30 days by direct transfer of potable water from aboard the International Space Station (ISS). This enables long term use without a weekly water change out, which meets spaceflight requirements, but contrasts with the general guidelines for the sanitation of water delivery systems. Even though the water is iodinated to minimize microbial growth, rodents are fed a special diet of high moisture nutrient-rich food bars based on the AIN-93 diet that may contribute to microbial growth in this water system. We designed a ground study to assess the quality of drinking water that is given to rodents throughout a mission. We conducted the ground test using 20 female C57BL/6J mice housed in this specialized habitat to mimic the timeline of a 90-day mission as well as the environmental conditions (temperature, humidity, and pCO2) within the ISS. We used a novel sampling method to test water at 2-week intervals for the 90-days, and also after each 30-day refill of the water delivery system. Mice in standard vivarium cages with water bottles were also included for comparison to the habitat. The results showed that overall microbial load remained close to zero for the duration, while total organic compound concentrations increased from 1370g/L to 10650g/L over the course of 90 days but remained below the level of concern. Inorganic ions and pH were also found to be at acceptable levels. Overall, we conclude that this system is effective in delivering clean, potable water to rodents for the 90-day duration of current missions to the ISS.

water↗

Use of piezoelectric actuators in active vibration control of rotating machinery

Theoretical and test results for the development of piezoelectric-actuator-based active vibration control (AVC) are presented. The evolution of this technology starts with an ideal model of the actuator and progresses to a more sophisticated model where the pushers force the squirrel cage ball bearing supports of a rotating shaft. The piezoelectric pushers consist of a stack of piezoelectric ceramic disks that are arranged on top of one another and connected in parallel electrically. This model consists of a prescribed displacement that is proportional to the input voltage and a spring that represents the stiffness of the stack of piezoelectric disks. System tests were carried out to stabilize the AVC system, verify its effectiveness in controlling vibration, and confirm the theory presented.

Lin, Reng Rong↗

A simulated lightning effects test facility for testing live and inert missiles and components

Details of a simulated lightning effects test facility for testing live and inert missiles, motors, and explosive components are described. The test facility is designed to simulate the high current, continuing current, and high rate-of-rise current components of an idealized direct strike lightning waveform. The Lightning Test Facility was in operation since May, 1988, and consists of: 3 separate capacitor banks used to produce the lightning test components; a permanently fixed large steel safety cage for retaining the item under test (should it be ignited during testing); an earth covered bunker housing the control/equipment room; a charge/discharge building containing the charging/discharging switching; a remotely located blockhouse from which the test personnel control hazardous testing; and interconnecting cables.

Craven, Jeffery D.↗

Medium-Range Structural Order as the Driver of Activated Dynamics and Complexity Reduction in Glass-Forming Liquids

Here, we analyze in depth the Elastically Collective Nonlinear Langevin Equation theory of activated dynamics in metastable liquids to establish that the predicted inter-relationships between the alpha relaxation time, local cage and collective elastic barriers, dynamic localization length, and shear modulus are causally related within the theory to the medium range order (MRO) static correlation length. The latter grows exponentially with density for metastable hard sphere fluids and as a nonuniversal inverse power law with temperature for supercooled liquids under isobaric conditions. The physical origin of predicted connections between the alpha time and other metrics of cage order and the thermodynamic inverse dimensionless compressibility is fully established. It is discovered that although kinetic constraints from the real space first coordination shell are important for the alpha time, they are of secondary importance compared to the consequences of the more universal MRO correlations in both the modestly and deeply metastable regimes. This understanding sheds new light on the theoretical basis for, and prior successes of, the predictive mapping of chemically complex thermal liquids to effective hard sphere fluids based on matching their dimensionless compressibilities, a scheme we call “complexity reduction”. In essence, the latter is equivalent to the physical requirement that the thermal liquid MRO correlation equals that of its effective hard sphere analog. The mapping alone is shown to provide a remarkable level of quantitative predictive power for the glass transition temperature T g of 21 molecular and polymer liquids. Predictions for the chemically specific absolute magnitude and growth with cooling of the MRO correlation length are obtained and lie in the window of 2–6 nm at T g . Dynamic heterogeneity, elastic facilitation, and beyond pair structure issues are briefly discussed. Future opportunities to theoretically analyze the equilibrated deep glass regime are outlined.

cancer↗

Effects of Age on Temperature Responses During Exposure to Hypergravity

Rats subjected to centrifugation show a marked decrease in body temperature relating to gravity level. Several studies have indicated, that an initial response to centrifugation is followed by acclimation. To test for differences between young (Y; 2 months) and mature (M; 8 months) rats in their response in temperature, both groups were exposed to hypergravity induced by centrifugation. Thirty-six male rats were divided into four groups according to age and G-load (control (1.0G-Y and 1.0G-M), 2.0G-Y or 2.0G-M) and were housed in pairs in standard vivarium cages. During the 7-day period of centrifugation, temperature was measured every five minutes by surgically implanted telemeters. Body mass was measured daily. We found that initial body temperature in 2.0G-M was less than that of 2.0G-Y. Both hypergravity groups (2.0G-Y and 2.0G-M) showed a decrease in temperature at the onset of centrifugation, and the change in temperature (Delta = 0.5 C) remained the same between the groups. Significant differences persisted with 2.0G-Y recovering to control values in four days and 2.0G-M recovering in five days. These results indicate that the mature animals have a similar response as the younger animals, but take longer to acclimate.

Fung, C.K.↗

Body Temperatures During Exercise in Deconditioned Dogs: Effect of NACL and Glucose Infusion

Infusion of glucose (Glu) into normal exercising dogs attenuates the rise in rectal temperature (Delta-Tre) when compared with delta-Tre during FFA infusion or no infusion. Rates of rise and delta-=Tre levels are higher during exercise after confinement. Therefore, the purpose of this study was to determine if Glu infusion would attenuate the exercise-induced excess hyperthermia after deconditioning. Rectal and quadricep femoris muscle temperatures (Tmu) were measured in 7 male, mongrel dogs dogs (19.6 +/- SD 3.0 kg) during 90 minutes of treadmill exercise (3.1 +/-SD 0.2 W/kg) with infusion (30ml/min/kg) of 40% Glu or 0.9% NaCL before BC) and after confinement (AC) in cages (40 x 110 x 80 cm) for 8 wk. Mean (+/-SE body wt. were 19.6 +/- 1.1 kg BC and 19.5 +/- 1.1kg AC, exercise VO2 were not different (40.0 - 42.0 mi/min/kg-1). With NaCl AC, NaCl BC, GluAC, and GluBC: Delta-Tre were, 1.8, 1.4, 1.3 and 0.9C respectively; and Delta-Tmu were 2.3, 1.9, 1.6, and 1.4C. respectively (P<0.05 from GluBC). Compared with NaCl infusion, attenuated both Delta-Tre and Delta-Tmu BC and AC, respectively. Compared with GluBC, GluAC attenuated Delta-Tmu but not Delta-Tre. Thus. with similar heat production, the mechanism for attenuation at bad body temperature with Glu infusion must affect avenues of heat dissipation.

Greenleaf, J. E.↗

Evolution and use of combined mechanical and thermal codes for cryogenic turbopump bearings

Shaft bearing system analysis codes were developed, improved, and used to investigate Space Shuttle Main Engine (SSME) Liquid Oxygen (LOX) turbopump bearing problems, and to support the Marshall Space Flight Center Bearing and Seal Materials Test (BSMT) program. Thermal network modeling uses the SINDA thermal code, and the modeling of bearing quasi-dynamic characteristics uses the SHABERTH bearing/shaft code. These codes are solved concurrently for a bearing/shaft system using software developed for this purpose. Simulation of the SSME LOX turbopump turbine and pump end bearings and the MSFC BSMT operating in liquid nitrogen (LN sub 2) and LOX was done. The thermal network models include the bearing components, bearing carriers, shaft, housing, frictional heat, and viscous fluid energy. A cage model was included to account for heat generation between the cage and rolling elements. Since most bearing surfaces operate at temperatures well above the coolant saturation temperature, and move at high speed relative to the coolant, forced convection boiling is the dominant mechanism for heat removal. Improved modeling of forced convection film boiling was incorporated to take into account the local vapor generation at the high temperature surfaces. Rearing preloads in the pump and tester are provided by preload springs. As bearing operating clearances and contact angles change due to thermal effects and loading, the bearing preload changes with these varying conditions. These characteristics were modeled and are included in the overall system models. Results from these models indicate an operational limit which, if exceeded, predicts a thermal excursion.

Cody, Joe C.↗

Conditioned feeding suppression in rats produced by cross-coupled and simple motions

Results are presented of an experiment on the induction of motion sickness in rats by the use of cross-coupled accelerations of magnitudes similar to those used in human experiments. Accelerations were produced in a seesaw apparatus with rotating disks supporting the animal cages mounted on each seesaw arm, and motion sickness was assessed according to the consumption of a sweet food previously offered to the animals immediately before the motion treatment. During a 1-hour test session 72 h after motion treatment and after a 24-h fast, rats having undergone cross-coupled vertical sinusoidal and rotational motion are observed to consume less food than those having experienced either type of motion alone, or no motion. The ordering of the conditioned suppressive feeding effects is consistent with the amounts of vestibular stimulation produced by the respective motions. The results support the existence of motion sickness effects in rats, even though they are unable to vomit.

Fox, R. A.↗

Fatigability and blood flow in the rat gastrocnemius-plantaris-soleus after hindlimb suspension

The hypothesis that hindlimb suspension (HS) increases the fatigability of the soleus during intense contractile activity and that the increased fatigue is associated with a reduced muscle blood flow was tested using caged control rats and rats subjected to HS for 15 days. After 15 days, either the soleus or the gastrocnemius-plantaris-soleus (G-P-S) muscle group was stimulated in situ (10 min at 100 Hz, 100 ms trains at 120/min), and in the G-P-S preparation, blood flow was measured with radiolabeled microspheres before and at 2 min and 10 min after the start of contractile activity. The results indicate that 15 days of HS resulted in increased fatigability of the soleus, but the effect was not caused by a reduced muscle blood flow.

Mcdonald, K. S.↗

Magnetic order and physical properties of the kagome metal UNb 6 ⁢Sn 6

The 𝑅⁢𝑀 6 ⁢𝑋 6 family of materials (𝑅 = rare-earth, 𝑀 = transition metal, 𝑋 = Ga, Si, Ge, Sn) produces an array of emergent phenomena, such as charge density waves, intrinsic Hall effects, and complex magnetic order, due to its kagome net of transition metal atoms, its local-moment magnetic anisotropies, and its extensive chemical tunability. Here, in this study, we report UNb 6⁢ Sn 6 , a new “166” material containing both an actinide and a 4⁢𝑑 transition metal, along with its nonmagnetic analog ThNb6⁢Sn6, to investigate the properties of a 5⁢𝑓−4⁢𝑑 electron 166 system. UNb 6 ⁢Sn 6 crystallizes in the hexagonal 𝑃⁢6/𝑚⁢𝑚⁢𝑚 space group with a small degree of disorder due to shifts in the size of the CoSn-like cages along the 𝑐 axis. Upon cooling at zero magnetic field, the material undergoes two magnetic phase transitions at 𝑇 2 = 46K and 𝑇 N = 43K. The low-temperature, zero-field phase is an antiferromagnet with ordered uranium moments and a k = (0,0,1/2) propagation vector determined by neutron diffraction. Remarkably, with a magnetic field applied along the 𝑐 axis, five additional magnetic transitions occur, evidenced by magnetization and resistivity data, before the moment saturates at 2.62 𝜇 B /U at 2 K and ≥ 13.6T. In two magnetic phase regions, the Hall resistivity of UNb 6⁢ Sn 6 significantly deviates from the magnetization, suggesting that the phases have a large Berry curvature or a change in the Fermi surface. The unknown magnetic ordering of the field-dependent phases of UNb 6⁢ Sn 6 demonstrates the complexity of the 5⁢𝑓−4⁢𝑑 166 system and encourages further study of its properties.

36 MATERIALS SCIENCE↗

Decreased swelling pressure of rat nucleus pulposus associated with simulated weightlessness

Data are presented on the effects of actual and simulated weightlessness on the swelling pressure of nucleus pulposus in rats exposed to 12.5 days of flight aboard Cosmos 1887 or to seven days of tail suspension, respectively. The flight-exposed rats were adapted to normal gravity for over 50 hrs prior to sacrifice and tissue harvesting. In the experiments with flight-exposed rats, swelling pressures were 690, 675, and 622 mm Hg for flight rats, synchronous controls, and vivarium controls, respectively. In experiments with simulated weightlessness, swelling pressures were 295, 610, and 527 mm Hg for tail-suspended rats, cage controls, and vivarium controls, respectively, suggesting that fluid moves into the disc during seven days of simulated weightlessness.

Hargens, Alan R.↗

Early adaptation to altered gravitational environments in the squirrel monkey

The feeding behavior of two squirrel monkeys flown in Spacelab 3 is compared to that of six monkeys exposed to 1.5 G through centrifugation. The monkeys in the centrifugation study were housed unrestrained in cages, maintained at 25 C + or - 1 C, exposed to a 12:12 light/dark cycle, and had unrestrained access to food and water. The Spacelab monkeys were maintained at 26 C, exposed to a 12:12 light/dark cycle and had unlimited food and water. It is observed that the centrifuge rats displayed a change in feeding behavior for 4 days prior to resuming a normal pattern; one Spacelab monkey exhibited a 6 day depression before recover to control levels, and the feeding pattern of the second monkey was not influenced by the environment. It is noted that the effect of an altered dynamic environment is variable on the feeding behavior of individual monkeys.

Fuller, C. A.↗

Liquid state theory of the structure of model polymerized ionic liquids

We employ polymer integral equation theory to study a simplified model of semiflexible polymerized ionic liquids (PolyILs) that interact via hard core repulsions and short range screened Coulomb interactions. The multi-scale structure in real and Fourier space of PolyILs (ions chosen to mimic Li, Na, K, Br, PF 6 , and TFSI) are determined as a function of melt density, Coulomb interaction strength, and ion size. Comparisons with a homopolymer melt, a neutral polymer–solvent-like athermal mixture, and an atomic ionic liquid are carried out to elucidate the distinct manner that ions mediate changes of polymer packing, the role of excluded volume effects, and the influence of chain connectivity, respectively. The effect of Coulomb strength depends in a rich manner on ion size and density, reflecting the interplay of steric packing, ion adsorption, and charge layering. Ion-mediated bridging of monomers is found, which intensifies for larger ions. Intermediate range charge layering correlations are characterized by a many-body screening length that grows with PolyIL density, cooling, and Coulomb strength, in disagreement with Debye–Hückel theory, but in accord with experiments. Qualitative differences in the collective structure, including an ion-size-dependent bifurcation of the polymer structure factor peak and pair correlation function, are predicted. The monomer cage order parameter increases significantly, but its collective ion counterpart decreases, as ions become smaller. Such behaviors allow one to categorize PolyILs into two broad classes of small and large ions. Furthermore, dynamical implications of the predicted structural results are qualitatively discussed.