Search NASASearch

SEARCH · Search NASA

Results for “Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Interlaced Characterization and Calibration (ICC) for Improved Computational Simulation Credibility

Accurate material characterization and model calibration are pivotal for simulations used for high-consequence engineering decisions. Current characterization and calibration methods (1) use simplified test specimen geometries and global data, (2) cannot guarantee that sufficient characterization data is collected for a specific model of interest, (3) provide only mean parameter values with no uncertainty quantification, and (4) are sequential, inflexible, and time-consuming. This work developed a new paradigm—coined Interlaced Characterization and Calibration (ICC)—which drives forward the state-of-the-art in model calibration by bringing together recent advancements into one improved workflow. The ICC paradigm (1) employs tools to efficiently use full-field data to calibrate high-fidelity material models, (2) aligns the data needed with the data collected by adopting an optimal experimental design protocol, (3) provides uncertainty metrics on the calibrated model parameters, and (4) incorporates these advances into a quasi real-time feedback loop. The ICC framework was validated synthetically with both low-fidelity and high-fidelity simulations paired with several different elastoplastic material models, and was also demonstrated experimentally with an aluminum 6061 cruciform exemplar specimen. Results showed that the ICC framework—in which Bayesian optimal experimental design actively guided the experiment— resulted in calibrations with similar or better accuracy than predetermined experiments based on subject matter expertise. Moreover, the ICC framework produced a complete model calibration— with quantified uncertainties on model parameters—in 1 week, a 5 - 10× increase in efficiency over traditional approaches. Thus, the ICC paradigm improves both the calibration process and quality, by (1) improving efficiency, which increases agility of solid mechanics modeling and enables utilization of computational simulation (CompSim) at earlier stages of the design cycle and (2) providing quantified, and in some cases reduced, parameter uncertainties, which increases confidence in model predictions and supports credible decision making.

97 MATHEMATICS AND COMPUTING

Evaluation of compressible-flow Preston tube calibrations

An experimental and analytical study has been made of the accuracy of various Preston tube calibration equations to determine local skin friction in two-dimensional supersonic and low-hypersonic flows. Experimental Preston tube calibration data from the present and previous studies were used to evaluate the calibration equations. The maximum value of the calibration parameters of the present data is more than an order of magnitude larger than that previously obtained; thereby, the evaluation of the various calibration equations is facilitated. The Preston tube technique was found to be very inaccurate in the low range of the calibration parameters. Above this range, there was a steady increase in accuracy with increasing values of the calibration parameters. No critical maximum tube diameter was found even with tubes about twice as large as the theoretical maximum allowable diameter. Of the two forms of the calibration equation previously existing, the logarithmic laws gave more accurate results than the power laws over an extended range of the calibration parameters in supersonic adiabatic flow.

Allen, J. M.

SAR calibration: A technology review

Various potential applications of amplitude-calibrated SAR systems are briefly described, along with an estimate of calibration performance requirements. A review of the basic SAR calibration problem is given. For background purposes and to establish consistent definition of terms, various conventional SAR performance parameters are reviewed along with three additional parameters which are directly related to calibrated SAR systems. Techniques for calibrating a SAR are described. Included in the results presented are: calibration philosophy and procedures; review of the calibration signal generator technology development with results describing both the development of instrumentation and internal calibration measurements for two SAR systems; summary of analysis and measurements required to determine optimum retroreflector design and configuration for use as a reference for the absolute calibration of a SAR system; and summary of techniques for in-flight measurements of SAR antenna response.

Larson, R. W.

Air data position-error calibration using state reconstruction techniques

During the highly maneuverable aircraft technology (HiMAT) flight test program recently completed at NASA Ames Research Center's Dryden Flight Research Facility, numerous problems were experienced in airspeed calibration. This necessitated the use of state reconstruction techniques to arrive at a position-error calibration. For the HiMAT aircraft, most of the calibration effort was expended on flights in which the air data pressure transducers were not performing accurately. Following discovery of this problem, the air data transducers of both aircraft were wrapped in heater blankets to correct the problem. Additional calibration flights were performed, and from the resulting data a satisfactory position-error calibration was obtained. This calibration and data obtained before installation of the heater blankets were used to develop an alternate calibration method. The alternate approach took advantage of high-quality inertial data that was readily available. A linearized Kalman filter (LKF) was used to reconstruct the aircraft's wind-relative trajectory; the trajectory was then used to separate transducer measurement errors from the aircraft position error. This calibration method is accurate and inexpensive. The LKF technique has an inherent advantage of requiring that no flight maneuvers be specially designed for airspeed calibrations. It is of particular use when the measurements of the wind-relative quantities are suspected to have transducer-related errors.

Whitmore, S. A.

Evaluation of a strain-gage load calibration on a low-aspect-ratio wing structure at elevated temperature

The environmental aspect of elevated temperature and its relationship to the science of strain gage calibrations of aircraft structures are addressed. A section of a wing designed for a high-speed aircraft structure was used to study this problem. This structure was instrumented with strain gages calibrated at both elevated and room temperatures. Load equations derived from a high-temperature load calibration were compared with equations derived from an identical load calibration at room temperature. The implications of the high temperature load calibration were studied from the viewpoint of applicability and necessity. Load equations derived from the room temperature load calibration resulted in generally lower equation standard errors than equations derived from the elevated temperature load calibration. A distributed load was applied to the structure at elevated temperature and strain gage outputs were measured. This applied load was then calculated using equations derived from both the room temperature and elevated temperature calibration data. It was found that no significant differences between the two equation systems existed in terms of computing this applied distributed load, as long as the thermal shifts resulting from thermal stresses could be identified. This identification requires a heating of the structure. Therefore, it is concluded that for this structure, a high temperature load calibration is not required. However, a heating of the structure is required to determine thermal shifts.

Reardon, Lawrence F.

Spectral calibration analysis of the airborne oceanographic lidar

Efforts were concentrated on the spectral resolution of the Airborne Oceanographic Lidar (AOL). This year's work was targeted towards the analysis of calibration techniques to enable the AOL to measure absolute radiances of both passive and active modes of operation. Absolute spectral calibration of the AOL is necessary in order to fully understand and monitor the sensitivity and stability of the total system. Calibration is also needed to obtain valid surface truth data, with which to improve the accuracy of satellite-borne oceanic color scanners. In particular, accurate measurements of oceanic chlorophyll concentrations rests upon reliable irradiance calibrations of both laser induced and solar induced chlorophyll fluoresence. An analysis was performed on the spectral calibration methods used by the AOL. The optical path of the instrumentation was examined to study how the radiance from a calibration sphere was influenced. Ray tracing analysis was performed, including the Cassegrain-telescope optics. It was determined that the calibration radiance was significantly effected by optical-defocusing, due to close positioning of the calibration sphere with respect to the telescope. Since the multi-mode usages of the AOL require varying altitudes and trajectories, a computational algorithm was developed to compensate for image distortions of the telescope optics. Secondary mirror blockage, secondary vignetting, and beam divergence was determined, in order to account for the actual amount of calibrated flux received at the spectral sensors.

Rousey, Carlton E.

Results of the 1988 NASA/JPL airborne SAR calibration campaign

During the spring of 1988, the NASA/JPL multifrequency, multipolarization SAR (synthetic aperture radar) flew in series of calibration experiments over the Goldstone dry lake bed. An array of calibration devices was deployed, including dihedral and trihedral corner reflectors, polarimetric active radar calibrators, passive receivers, and CW (continuous wave) tone generators. The aim of the campaign was to calibrate both amplitude and phase of the resulting SAR images, over long and short time scales. The results of the analysis of the calibration data collected in the spring of 1988 are presented. Trihedral corner reflector signatures and certain image background measures are used to externally calibrate relative amplitude and phase between polarizations at a given frequency, and to calibrate across frequencies. Assessments are made of the calibration accuracy as a function of image frame position for each frequency, and the stability of the radar calibration over long and short time-scales.

Freeman, A.

The in-flight calibration of the Hubble Space Telescope attitude sensors

A detailed review of the in-flight calibration of the Hubble Space Telescope attitude sensors is presented. The review, which covers the period from the April 24, 1990, launch of the spacecraft until the time of this writing (June 1991), describes the calibrations required and accuracies achieved for the four principal attitude sensing systems on the spacecraft: the magnetometers, the fixed head star trackers, the gyroscopes, and the fine guidance sensors (FGS's). In contrast to the other three sensor groups, the Hubble Telecope's FGS's are unique in the precision and performance levels being attempted; spacecraft control and astrometric research at the near-milliarcsecond level are the ultimate goals. FGS calibration accuracies at the 20-milliarcsecond level have already been achieved, and plans for new data acquisitions and reductions that should substantially improve these results are in progress. A summary of the basic attributes of each of the four sensor groups with respect to its usage as an attitude measuring system is presented, followed by a discussion of the calibration items of interest for that group. The calibration items are as follows: for the magnetometers, the corrections for the spacecraft's static and time-varying magnetic fields; for the fixed-head star trackers, their relative alignments and use in performing onboard attitude updates; for the gyroscopes, their scale factors, alignments, and drift rate biases; and for the FGS's, their magnifications, optical distortions, and alignments. The discussion covers the procedures used for each calibration, as well as the order of the calibrations within the general flow of orbital verification activities. It also includes a synopsis of current plans for the eventual calibration of the FGS's to achieve their near-milliarcsecond design accuracy. The conclusions include a table indicating the current and predicted ultimate accuracies for each of the calibration items.

Welter, Gary L.

Calibration of NASA/JPL DC-8 SAR data

The paper describes a number of improvements in calibration of NASA/JPL DC-8 SAR (synthetic aperture radar) data, intended to make calibrated data from the system available to the majority of the investigators. The improvements include a move to a better site for calibration of the system at the start of each campaign season, the release of software to allow users to calibrate their data, the supply of trihedral corner reflectors and instructions on how to deploy them, and the setting up of an archive of calibrated data. Analysis of the calibration performance of the DC-8 SAR over a number of sites during 1990 suggests that the system is sufficiently stable to allow calibration of the standard data products without the presence of calibration devices within the scene. The limiting factor on DC-8 SAR data calibration would now appear to be the knowledge of the altitude of the aircraft, which determines the relationship between the measured slant range coordinates and the antenna pattern in elevation.

Freeman, A.

Approach to derivation of SIR-C science requirements for calibration

Many of the experiments proposed for the forthcoming SIR-C mission require calibrated data, for example those which emphasize (1) deriving quantitative geophysical information (e.g., surface roughness and dielectric constant), (2) monitoring daily and seasonal changes in the Earth's surface (e.g., soil moisture), (3) extending local case studies to regional and worldwide scales, and (4) using SIR-C data with other spaceborne sensors (e.g., ERS-1, JERS-1, and Radarsat). There are three different aspects to the SIR-C calibration problem: radiometric and geometric calibration, which have been previously reported, and polarimetric calibration. The study described in this paper is an attempt at determining the science requirements for polarimetric calibration for SIR-C. A model describing the effect of miscalibration is presented first, followed by an example describing how to assess the calibration requirements specific to an experiment. The effects of miscalibration on some commonly used polarimetric parameters are also discussed. It is shown that polarimetric calibration requirements are strongly application dependent. In consequence, the SIR-C investigators are advised to assess the calibration requirements of their own experiment. A set of numbers summarizing SIR-C polarimetric calibration goals concludes this paper.

Dubois, Pascale C.

An Automated Thermocouple Calibration System

An Automated Thermocouple Calibration System (ATCS) was developed for the unattended calibration of type K thermocouples. This system operates from room temperature to 650 C and has been used for calibration of thermocouples in an eight-zone furnace system which may employ as many as 60 thermocouples simultaneously. It is highly efficient, allowing for the calibration of large numbers of thermocouples in significantly less time than required for manual calibrations. The system consists of a personal computer, a data acquisition/control unit, and a laboratory calibration furnace. The calibration furnace is a microprocessor-controlled multipurpose temperature calibrator with an accuracy of +/- 0.7 C. The accuracy of the calibration furnace is traceable to the National Institute of Standards and Technology (NIST). The computer software is menu-based to give the user flexibility and ease of use. The user needs no programming experience to operate the systems. This system was specifically developed for use in the Microgravity Materials Science Laboratory (MMSL) at the NASA LeRC.

Bethea, Mark D.

Calibration of a helium-cooled infrared spatial radiometer and grating spectrometer

Methods used by the Space Dynamics Laboratory of Utah State University (SDL/USU) to calibrate infrared sensors are described, using the Infrared Background Signature Survey (IBSS) spatial radiometer and grating spectrometer as examples. A calibration equation and a radiometric model are given for each sensor to describe their responsivity in terms of individual radiometric parameters. The calibration equation terms include dark offset, linearity, absolute responsivity, and measurement uncertainty, and the radiometric model domains include spatial, spectral, and temporal domains. A portable calibration facility, designed and fabricated by SDL/USU, provided collimated, extended, diffuse scatter, and Jones sources in a single cryogenic dewar. This multi-function calibrator allowed calibration personnel to complete a full calibration of the IBSS infrared radiometer and spectrometer in two 15-day periods. A calibration data system was developed to control and monitor the calibration facility, and to record and analyze sensor data.

Jacobsen, Larry

In-flight radiometric calibration of AVIRIS in 1994

The AVIRIS sensor must be calibrated at the time it measures spectra from the ER-2 airborne platform in order to achieve research and application objectives that are both quantitative and physically based. However, the operational environment inside the Q-bay of the ER-2 at 20 km altitude differs from that in the AVIRIS laboratory with respect to temperature, pressure, vibration, and high-frequency electromagnetic fields. Experiments at surface calibration targets are used in each flight season to confirm the accuracy of AVIRIS in-flight radiometric calibrations. For these experiments, the MODTRAN radiative transfer code is constrained by using in situ measurements to independently predict the upwelling spectral radiance arriving at AVIRIS for a specific calibration target. AVIRIS calibration is validated in flight by comparing the MODTRAN-predicted radiance to the laboratory-calibrated radiance measured by the AVIRIS sensor for the same time over the calibration target. We present radiometric calibration results for the AVIRIS in-flight calibration experiment held at the beginning of the 1994 flight season.

Green, Robert O.

Stellar-based calibration in the far infrared with application to IRAS Band 4

Because stars emit very small portions of their outputs in the far infrared, using them as calibrators requires precise measurement and correction for filter leaks at shorter wavelengths. Therefore, it is common to base far infrared calibrations on planetary objects such as asteriods. However, asteroids are complex geological bodies whose thermal properties depend on their evolutionary histories as well as on their gross parameters such as mass and composition, making them difficult to model as calibrators. We propose a new method for measuring filter leaks that can be carried out using the end-to-end detector system and therefore allows reliable use of stellar calibrators. We illustrate this method by showing that the Infrared Astronomy Satellite (IRAS) 100 micrometers (Band 4) filters had a short wavelength leak of 14.3% +/- 3.6% on stars similar to alpha Boo, but that there is no detectable leak in the 60 micrometers (Band 3) filters. We derive a calibration for Band 4 from stellar colors in a way that is closely analogous to the calibrations of Bands 1, 2, and 3. With correction for the leak, the stellar-based calibration is virtually identical to the original calibration based on asteroids; this result requires that the spectra of the asteriods for the original calibration differ from greybody behavior between 60 and 100 micrometers by about 10%.

Kirby, D. J.

Aircraft electric field measurements: Calibration and ambient field retrieval

An aircraft locally distorts the ambient thundercloud electric field. In order to determine the field in the absence of the aircraft, an aircraft calibration is required. In this work a matrix inversion method is introduced for calibrating an aircraft equipped with four or more electric field sensors and a high-voltage corona point that is capable of charging the aircraft. An analytic, closed form solution for the estimate of a (3 x 3) aircraft calibration matrix is derived, and an absolute calibration experiment is used to improve the relative magnitudes of the elements of this matrix. To demonstrate the calibration procedure, we analyze actual calibration date derived from a Lear jet 28/29 that was equipped with five shutter-type field mill sensors (each with sensitivities of better than 1 V/m) located on the top, bottom, port, starboard, and aft positions. As a test of the calibration method, we analyze computer-simulated calibration data (derived from known aircraft and ambient fields) and explicitly determine the errors involved in deriving the variety of calibration matrices. We extend our formalism to arrive at an analytic solution for the ambient field, and again carry all errors explicitly.

Koshak, William J.

Transportability of a laser-induced fluorescence calibration for NO at high pressure

Obtaining quantitative measurements of NO concentration via laser-induced fluorescence (LIF) at high pressure requires application of a suitable calibration. While it is best to calibrate as close to the measurement condition as possible, this is not always feasible. To assess the transportability of a calibration factor at high pressure, we have calculated ratios between linear LIF signals corresponding to a constant NO concentration at different measurement and calibration conditions for high-pressure ethane flames. We find that pressure broadening limits the utility of calibrating at a pressure different from that of the measurement, although a calibration performed at a higher pressure is applicable over a wider range of pressures than one performed at atmospheric pressure. If one calibrates at the same pressure, it is best to calibrate at a temperature within 500 K of the measurement temperature. In general, the calculations indicate that a judicious choice of a calibration condition will guarantee a measured NO concentration within a factor of two of the actual NO concentration.

Reisel, John R.

SeaWiFS calibration and algorithm validation

A substantial amount of field research has been completed during this period (1 October 1994 - 31 October 1995). The applicability of different in-flight calibration methods was studied. In addition, various field instruments and new equipment were tested to appraise their usefulness during such calibration activities. The purposes and (expected) results of these field experiments are detailed in separate sections of this report. One section contains a synopsis of calibrations conducted over both land and water targets. A second section contains the results of an experiment conducted to determine the spatial uniformity of surface reflectance at Lake Tahoe, the chosen water calibration site. Advances were also made in the area of radiative transfer software development. An existing exact radiative transfer code, Successive Orders (SO), was modified to provide outputs of the radiance distribution at arbitrary altitudes above a selected calibration target. These modifications were needed to utilize the SO software in radiance-based sensor calibrations. Serious thought was given to the general applicability of various calibration techniques to calibrations conducted over water surfaces. In particular, the practicality of the radiance-based and reflectance-based methods of in-flight radiometric calibration was evaluated.

Parada, Robert J., Jr.

Five-Hole Flow Angle Probe Calibration for the NASA Glenn Icing Research Tunnel

A spring 1997 test section calibration program is scheduled for the NASA Glenn Research Center Icing Research Tunnel following the installation of new water injecting spray bars. A set of new five-hole flow angle pressure probes was fabricated to properly calibrate the test section for total pressure, static pressure, and flow angle. The probes have nine pressure ports: five total pressure ports on a hemispherical head and four static pressure ports located 14.7 diameters downstream of the head. The probes were calibrated in the NASA Glenn 3.5-in.-diameter free-jet calibration facility. After completing calibration data acquisition for two probes, two data prediction models were evaluated. Prediction errors from a linear discrete model proved to be no worse than those from a full third-order multiple regression model. The linear discrete model only required calibration data acquisition according to an abridged test matrix, thus saving considerable time and financial resources over the multiple regression model that required calibration data acquisition according to a more extensive test matrix. Uncertainties in calibration coefficients and predicted values of flow angle, total pressure, static pressure. Mach number. and velocity were examined. These uncertainties consider the instrumentation that will be available in the Icing Research Tunnel for future test section calibration testing.

Gonsalez, Jose C.