Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Measurement of very large flow angles with non-nulling seven-hole probes

This paper describes a method for measuring local direction and total and static pressures of a flow by means of a fixed probe, provided that the local air flow does not make an angle of more than 80 degrees with the axis of the probe. The probe is easily manufactured from standard-sized tubing materials. The power series calibration method used with the probe results in explicit polynomial expressions for the desired aerodynamic properties. The calibration method is easily programmed on a data acquisition system. This paper includes an example of a complete incompressible calibration.

Gallington, R. W.↗

Enhancements to the Open Access Spectral Band Adjustment Factor Online Calculation Tool for Visible Channels

With close to 40 years of satellite observations, from which, cloud, land-use, and aerosol parameters can be measured, inter-consistent calibrations are needed to normalize retrievals across satellite records. Various visible-sensor inter-calibration techniques have been developed that utilize radiometrically stable Earth targets, e.g., deep convective clouds and desert/polar ice pseudo-invariant calibration sites. Other equally effective, direct techniques for intercalibration between satellite imagers are simultaneous nadir overpass comparisons and ray-matched radiance pairs. Combining independent calibration results from such varied techniques yields robust calibration coefficients, and is a form of self-validation. One potential source of significant error when cross-calibrating satellite sensors, however, are the often small but substantial spectral discrepancies between comparable bands, which must be accounted for. As such, visible calibration methods rely on a Spectral Band Adjustment Factor (SBAF) to account for the spectral-response function- induced radiance differences between analogous imagers. The SBAF is unique to each calibration method as it is a function of the Earth-reflected spectra. In recent years, NASA Langley pioneered the use of SCIAMACHY-, GOME-2-, and Hyperion-retrieved Earth spectra to compute SBAFs. By carefully selecting hyperspectral footprints that best represent the conditions inherent to an inter-calibration technique, the uncertainty in the SBAF is greatly reduced. NASA Langley initially provided the Global Space-based Inter-calibration System processing and research centers with online SBAF tools, with which users select conditions to best match their calibration criteria. This article highlights expanded SBAF tool capabilities for visible wavelengths, with emphasis on the use of the spectral range filtering for the purpose of separating scene conditions for the channel that the SBAF is needed based on the reflectance values of other bands. In other words, spectral filtering will enable better scene-type selection for bands where scene determination is difficult without information from other channels, which should prove valuable to users in the calibration community.

Scarino, Benjamin↗

XCal: model-based approach to X-ray CT spectral calibration

Transmission X-ray computed tomography (CT) is widely used to quantitatively reconstruct 3D objects composed of multiple materials. However, accurate CT reconstruction requires the system to be calibrated to account for the effective X-ray spectrum. Unfortunately, measurement of the effective spectrum is ill-posed, and existing calibration methods require that the system be recalibrated when the system parameters are changed. In this paper, we propose XCal, a multi-energy model-based spectral calibration approach for X-ray CT. The XCal approach models the effective spectrum using a separable physics-based model of the CT system. The model parameters are then estimated by fitting calibration data with known objects at multiple energies. An important advantage of XCal is that it allows the user to change scanner settings, such as the source voltage or X-ray filters, without the need for recalibration. Evaluations on simulated and measured datasets demonstrate that XCal significantly improves the accuracy of the estimated spectrum as compared to existing calibration methods.

Li, Wenrui [Purdue Univ., West Lafayette, IN (Unit↗

FY24 Progress Report on Viscosity and Thermal Conductivity Measurements of Nuclear Industry Relevant Chloride Salts: An Experimental and Computational Study

As presented in this report, experimental and computational techniques were performed to assess the viscosity and thermal conductivity of key alkali and actinide chloride mixtures for molten salt reactor developers. These mixtures were pure LiCl, NaCl-KCl, LiCl-NaCl, LiCl-KCl, LiCl-NaCl-KCl, and NaCl-UCl 3 . Experimental measurements of viscosity were performed with a rolling ball viscometer, whereas experimental measurements of thermal conductivity were performed with a variable gap apparatus. Additional benchmarking work was performed using both property measurement systems to prepare for x-ray radiography in stainless-steel crucibles for viscosity and to ensure that calibration methods were accurate for thermal conductivity before assessing the NaCl-UCl 3 system. Validation data for the NaCl-UCl 3 in literature are minimal. Details on the calibration methods, salt measurement processes, and sources of error and uncertainty are discussed in detail for both property measurements. The computational methods described herein involved ab-initio molecular dynamics (AIMD) calculations using CP2K. The calculations were performed for the LiCl-KCl-NaCl and NaCl-UCl 3 systems. These calculations not only provided thermophysical property estimations for comparison to experimental data, but they also allowed for the determination of diffusion coefficients, coordination numbers, and radial distribution functions to provide insight into ion mobility and local coordination environments, which is linked to macroscopic property trends.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Air data position-error calibration using state reconstruction techniques

During the highly maneuverable aircraft technology (HiMAT) flight test program recently completed at NASA Ames Research Center's Dryden Flight Research Facility, numerous problems were experienced in airspeed calibration. This necessitated the use of state reconstruction techniques to arrive at a position-error calibration. For the HiMAT aircraft, most of the calibration effort was expended on flights in which the air data pressure transducers were not performing accurately. Following discovery of this problem, the air data transducers of both aircraft were wrapped in heater blankets to correct the problem. Additional calibration flights were performed, and from the resulting data a satisfactory position-error calibration was obtained. This calibration and data obtained before installation of the heater blankets were used to develop an alternate calibration method. The alternate approach took advantage of high-quality inertial data that was readily available. A linearized Kalman filter (LKF) was used to reconstruct the aircraft's wind-relative trajectory; the trajectory was then used to separate transducer measurement errors from the aircraft position error. This calibration method is accurate and inexpensive. The LKF technique has an inherent advantage of requiring that no flight maneuvers be specially designed for airspeed calibrations. It is of particular use when the measurements of the wind-relative quantities are suspected to have transducer-related errors.

Whitmore, S. A.↗

SU-F-T-282: Quality Assurance for IMRT/VMAT QA Devices: Issues Affecting the Timing for ArcCHECK Recalibration

Purpose: To discuss several factors surrounding the decision on when to recalibrate the ArcCHECK device as well as present a simple and efficient monthly check to evaluate ArcCHECK calibrations. Methods: ArcCheck (Sun Nuclear) calibrations were evaluated monthly by measuring a 25×25cm{sup 2} field with 100 MU. Since ArcCHECK measurements are run on an almost nightly basis, such additional square field measurements are obtained with minimal additional effort. An in-house MATLAB script compares two radial (y-direction) profiles from the top/center of the new measurement relative to a baseline measurement acquired at the last device calibration. The program automatically generates PDF profile and percent difference comparisons for inspection. Recalibration is based on inspection of measurement profile shapes and percent differences from the baseline measurement. Results: The method presented here shows the utility of a simple monthly check for evaluating ArcCHECK calibrations, and in addition shows the importance of recalibrating after Linac beam steering. Our device required recalibration approximately every 8–10 months. However, for ease of scheduling, we propose a bi-annual recalibration interval. Clinics with a lighter/heavier IMRT/VMAT QA case load may require different recalibration intervals, which are easily determined using the single-field method presented. Analysis of additional square fields is also easily incorporated, if desired. We further illustrate the importance of array recalibration given that diode irradiation is not uniform over the entire device, with central diodes receiving more than 900 Gy over the course of 10 months and peripheral diodes receiving as little as 50 Gy (in our experience). Finally, we show that timely device recalibration decreases spread in clinical IMRT/VMAT QA gamma passing rates. Conclusion: Quality assurance for ArcCHECK array calibrations is important to ensure quality IMRT/VMAT QA comparisons. For many clinics, calibrations should be performed at least annually, if not more frequently, based on use of the proposed monthly check.

60 APPLIED LIFE SCIENCES↗

Retrievals of Thick Cloud Optical Depth from the Geoscience Laser Altimeter System (GLAS) by Calibration of Solar Background Signal

Laser beams emitted from the Geoscience Laser Altimeter System (GLAS), as well as other space-borne laser instruments, can only penetrate clouds to a limit of a few optical depths. As a result, only optical depths of thinner clouds (< about 3 for GLAS) are retrieved from the reflected lidar signal. This paper presents a comprehensive study of possible retrievals of optical depth of thick clouds using solar background light and treating GLAS as a solar radiometer. To do so we first calibrate the reflected solar radiation received by the photon-counting detectors of GLAS' 532 nm channel, which is the primary channel for atmospheric products. The solar background radiation is regarded as a noise to be subtracted in the retrieval process of the lidar products. However, once calibrated, it becomes a signal that can be used in studying the properties of optically thick clouds. In this paper, three calibration methods are presented: (I) calibration with coincident airborne and GLAS observations; (2) calibration with coincident Geostationary Operational Environmental Satellite (GOES) and GLAS observations of deep convective clouds; (3) calibration from the first principles using optical depth of thin water clouds over ocean retrieved by GLAS active remote sensing. Results from the three methods agree well with each other. Cloud optical depth (COD) is retrieved from the calibrated solar background signal using a one-channel retrieval. Comparison with COD retrieved from GOES during GLAS overpasses shows that the average difference between the two retrievals is 24%. As an example, the COD values retrieved from GLAS solar background are illustrated for a marine stratocumulus cloud field that is too thick to be penetrated by the GLAS laser. Based on this study, optical depths for thick clouds will be provided as a supplementary product to the existing operational GLAS cloud products in future GLAS data releases.

Yang, Yuekui↗

The importance and attainment of accurate absolute radiometric calibration

The importance of accurate absolute radiometric calibration is discussed by reference to the needs of those wishing to validate or use models describing the interaction of electromagnetic radiation with the atmosphere and earth surface features. The in-flight calibration methods used for the Landsat Thematic Mapper (TM) and the Systeme Probatoire d'Observation de la Terre, Haute Resolution visible (SPOT/HRV) systems are described and their limitations discussed. The questionable stability of in-flight absolute calibration methods suggests the use of a radiative transfer program to predict the apparent radiance, at the entrance pupil of the sensor, of a ground site of measured reflectance imaged through a well characterized atmosphere. The uncertainties of such a method are discussed.

Slater, P. N.↗

Quantitative infrared spectroscopy of environmentally sensitive and rough materials

Fourier transform infrared (FTIR) spectroscopy is a widely used characterization technique for studying chemical compositions and lightmatter interactions in the infrared range. However, it remains challenging to use conventional FTIR equipment to characterize materials that are environmentally sensitive and/or have rough surfaces due to their dynamic response to external stimuli (e.g., humidity) and light scattering from the sample surface. Here, we describe an approach enabling quantitative infrared spectroscopy measurements of these challenging samples, including transmittance, reflectance, and emissivity. We designed and 3D-printed a miniaturized environmental chamber that can be directly inserted into the sample holder of a conventional integrating sphere to perform total transmission and reflection measurements in controlled environments. Moreover, a calibration method was developed to exclude light scattering from rough surfaces of the sample and the distortion created by infrared windows. To illustrate the potential application of this method, we have performed quantitative infrared measurements, both specular and diffusive, on a sapphire standard reference with a specular surface, as well as a textile sample that has a rough surface and is dynamically responsive to changes in humidity. The calibrated results measured with the equipped chamber match those measured without the IR windows, demonstrating the viability of our environmental chamber and the proposed calibration method. This quantitative infrared spectroscopy measurement technique may help advance fields such as metasurfaces and adaptive textiles, where samples are often rough, dynamically responsive, and/or environmentally sensitive.

3D printing↗

TPSAS-NF1676L-19788-DND

The calibration of the historical AVHRR visible channels has always been hindered by the degrading NOAA satellite orbits. The complete AVHRR record spans over three decades making it useful for cloud, aerosol, and land use climate studies. Studies that monitor long-term changes in these properties require climate quality calibration. The AVHRR sensors do not have any onboard visible calibration, unlike the IR channels. Many AVHRR post-launch calibration methods have been published. Some of these are based on the pseudo invariant targets such as desert and polar ice and others employ direct calibration transfer from a well-calibrated sensor such as MODIS. Most historical studies only employed only one method and reconciling calibration differences from multiple studies was difficult. This study employs multiple calibration approaches, which are then merged according to their individual uncertainty. Since the visible spectral response functions are similar across AVHRR sensor and that the morning and afternoon orbits usually degrade in the same manner, an afternoon and morning orbiter during the MODIS era is chosen as the reference AVHRR sensor. The reference AVHRR sensor is inter-calibrated with the Aqua-MODIS Collection 6 standard using simultaneous nadir overpass (SNO) radiance pairs. Three pseudo invariant target approaches are utilized, deserts, polar ice and deep convective clouds. These sites are characterized using reference AVHRR reflectances as a function of solar zenith angle. The multiple calibration approach is then validated with non-reference AVHRR sensor during the MODIS era, using AVHRR and MODIS SNO measurements. For historical AVHRR satellite having consistent calibration across invariant targets then validates the approach. This calibration effort is in sponsored by the NOAA CDR program to provide climate quality visible calibration coefficients to the remote sensing community. Each of the calibration approaches are unique and when utilized in tandem can accurately calibrate the AVHRR record. AVHRR calibration methods cannot rely on repeatable annual orbits for calibration model development. Inconsistent results prompt code and invariant target examinations that cannot be determined using only single method approaches. Results from this study will be presented at the meeting.

David Doelling↗

New Method for Calibration for Hyperspectral Pushbroom Imaging Systems

A new, easy-to-implement approach for achieving highly accurate spectral and radiometric calibration of array-based, hyperspectral pushbroom imagers is presented in this paper. The equivalence of the plane of the exit port of an integrating sphere to a Lambertian surface is utilized to provide a field-filling radiance source for the imager. Several different continuous wave lasers of various wavelengths and a quartz-tungsten-halogen lamp internally illuminate the sphere. The imager is positioned to "stare" into the port, and the resultant data cube is analyzed to determine wavelength calibrations, spectral widths of channels, radiometric characteristics, and signal-to-noise ratio, as well as an estimate of signal-to-noise performance in the field. The "smile" (geometric distortion of spectra) of the system can be quickly ascertained using this method. As the price and availability of solid state laser sources improve, this technique could gain wide acceptance.

Ryan, Robert↗

Impacts of Cross-Platform Vicarious Calibration on the Deep Blue Aerosol Retrievals for Moderate Resolution Imaging Spectroradiometer Aboard Terra

The retrieval of aerosol properties from spaceborne sensors requires highly accurate and precise radiometric measurements, thus placing stringent requirements on sensor calibration and characterization. For the Terra/Moderate Resolution Imaging Spedroradiometer (MODIS), the characteristics of the detectors of certain bands, particularly band 8 [(B8); 412 nm], have changed significantly over time, leading to increased calibration uncertainty. In this paper, we explore a possibility of utilizing a cross-calibration method developed for characterizing the Terral MODIS detectors in the ocean bands by the National Aeronautics and Space Administration Ocean Biology Processing Group to improve aerosol retrieval over bright land surfaces. We found that the Terra/MODIS B8 reflectance corrected using the cross calibration method resulted in significant improvements for the retrieved aerosol optical thickness when compared with that from the Multi-angle Imaging Spectroradiometer, Aqua/MODIS, and the Aerosol Robotic Network. The method reported in this paper is implemented for the operational processing of the Terra/MODIS Deep Blue aerosol products.

Jeong, Myeong-Jae↗

A review of the developments of radioxenon detectors for nuclear explosion monitoring

Developments in radioxenon monitoring since the implementation of the International Monitoring System are reviewed with emphasis on the most current technologies to improve detector sensitivity and resolution. The nuclear detectors reviewed include combinations of plastic and NaI(Tl) detectors, high purity germanium detectors, silicon detectors, and phoswich detectors. The minimum detectable activity and calibration methods for the various detectors are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Primary reference cell calibrations at SERI - History and methods

The tabular calibration method used at the Solar Energy Research Institute (SERI) for primary reference cells is derived and described in detail. An uncertainty analysis shows that the tabular method should have a total uncertainty of + or - 1.0 percent; data from five years of calibrations are then shown to support this analysis. Results from SERI's tabular method are compared with terrestrial calibrations performed by the NASA Lewis Research Center in the late 1970s.

Osterwald, C. R.↗

A numerical Bayesian-calibrated characterization method for multiscale prepreg preforming simulations with tension-shear coupling

We report that carbon fiber reinforced plastics (CFRPs) are attracting growing attention in industry because of their enhanced properties. Preforming of thermoset carbon fiber prepregs is one of the most common production techniques of CFRPs. To simulate preforming, several computational methods have been developed. Most of these methods, however, obtain the material properties directly from experiments such as uniaxial tension and bias-extension where the coupling effect between tension and shear is not considered. Neglecting this coupling effect deteriorates the prediction accuracy of simulations. To address this issue, we develop a Bayesian model calibration and material characterization approach in a multiscale finite element preforming simulation framework that utilizes mesoscopic representative volume element (RVE) to account for the tension-shear coupling. A new geometric modeling technique is first proposed to generate the RVE corresponding to the close-packed uncured prepreg. This RVE model is then calibrated with a modular Bayesian approach to estimate the yarn properties, test its potential biases against the experiments, and fit a stress emulator. Finally, the predictive capability of this multiscale approach is further demonstrated by employing the stress emulator in the macroscale preforming simulation which shows that this approach can provide accurate predictions.

36 MATERIALS SCIENCE↗

Digital Correlation Microwave Polarimetry: Analysis and Demonstration

The design, analysis, and demonstration of a digital-correlation microwave polarimeter for use in earth remote sensing is presented. We begin with an analysis of three-level digital correlation and develop the correlator transfer function and radiometric sensitivity. A fifth-order polynomial regression is derived for inverting the digital correlation coefficient into the analog statistic. In addition, the effects of quantizer threshold asymmetry and hysteresis are discussed. A two-look unpolarized calibration scheme is developed for identifying correlation offsets. The developed theory and calibration method are verified using a 10.7 GHz and a 37.0 GHz polarimeter. The polarimeters are based upon 1-GS/s three-level digital correlators and measure the first three Stokes parameters. Through experiment, the radiometric sensitivity is shown to approach the theoretical as derived earlier in the paper and the two-look unpolarized calibration method is successfully compared with results using a polarimetric scheme. Finally, sample data from an aircraft experiment demonstrates that the polarimeter is highly-useful for ocean wind-vector measurement.

Piepmeier, J. R.↗

The Interstellar Medium in [O iii]-selected Star-forming Galaxies at z ∼ 3.2

We present new results from near-infrared spectroscopy with Keck/MOSFIRE of [O iii]-selected galaxies at z∼3.2. With our H and K band spectra, we investigate the interstellar medium (ISM) conditions, such as ionization states and gas metallicities. [O iii] emitters at z∼3.2 show a typical gas metallicity of 12+log(O/H)=8.07±0.07 at log(M{sub ∗}/M{sub ⊙}) ∼ 9.0--9.2 and 12+log(O/H)=8.31±0.04 at log(M{sub ∗}/M{sub ⊙}) ∼ 9.7--10.2 when using the empirical calibration method. We compare the [O iii] emitters at z∼3.2 with UV-selected galaxies and Lyα emitters at the same epoch and find that the [O iii]-based selection does not appear to show any systematic bias in the selection of star-forming galaxies. Moreover, comparing with star-forming galaxies at z∼2 from the literature, our samples show similar ionization parameters and gas metallicities as those obtained by the previous studies that used the same calibration method. We find no strong redshift evolution in the ISM conditions between z∼3.2 and z∼2. Considering that the star formation rates at a fixed stellar mass also do not significantly change between the two epochs, our results support the idea that the stellar mass is the primary quantity to describe the evolutionary stages of individual galaxies at z>2.

79 ASTRONOMY AND ASTROPHYSICS↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗