Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Update on Geothermal Direct-Use Installations in the United States

Direct-use of geothermal energy currently has limited penetration in the United States, with an estimated installed capacity of about 500 MWth, supplying on the order of 0.01% of the total annual U.S. heat demand (about 30 EJ). We see higher penetration levels in other countries such as Iceland (about 90%) and Hungary (2.5%). An updated database of geothermal direct-use systems in the U.S. has been compiled and analyzed, building upon the Oregon Institute of Technology (OIT) Geo-Heat Center direct-use database. Types of directuse applications examined include hot springs resorts and pools, aquaculture farms, greenhouses, and district heating systems, among others; power-generating facilities and ground-source heat pumps were excluded. Where possible, the current operation status, open and close dates, well data, and other technical data were obtained for each entry. The database contains 545 installations, of which 407 are open, 108 are closed, and 30 have an unknown status. Spas are the most common type of installation, accounting for 50% of installations by number. Aquaculture installations (46 out of 407 open installations) account for the largest percentage (26%) of installed capacity in operation (129 MWth out of 501 MWth). Historical deployment curves show the installed capacity significantly increased in the 1970s and 1980s mainly due to development of geothermal district heating, aquaculture, and greenhouse systems. Since the 2000s, geothermal direct-use development appears to have slowed, and the number of sites in operation decreased due to closures. Case studies reveal multiple barriers to geothermal direct-use implementation and operation, including 1) existence of an information gap among stakeholders, developers, and the general public, 2) competition from cheap natural gas, and 3) the family-owned, small-scale nature of businesses might result in discontinuation among generations.

15 GEOTHERMAL ENERGY↗

Performance, Cost, and Financial Parameters of Geothermal District Heating Systems for Market Penetration Modeling under Various Scenarios

Geothermal district heating (GDH) systems have limited penetration in the U.S., with an estimated installed capacity of only 100 MWth for a total of 21 sites. We see higher deployment in other regions, for example, in Europe with an installed capacity of more than 4,700 MWth for 257 GDH sites. The U.S. Department of Energy Geothermal Vision (GeoVision) Study is currently looking at the potential to increase the deployment in the U.S. and to understand the impact of this increased deployment. This paper reviews 31 performance, cost, and financial parameters as input for numerical simulations describing GDH system deployment in support of the GeoVision effort. The focus is on GDH systems using hydrothermal and Enhanced Geothermal System resources in the U.S.; ground-source heat pumps and heat-to-electricity conversion technology were excluded. Parameters investigated include 1) capital and operation and maintenance costs for both subsurface and surface equipment; 2) performance factors such as resource recovery factors, well flow rates, and system efficiencies; and 3) financial parameters such as inflation, interest, and tax rates. Current values as well as potential future improved values under various scenarios are presented. Sources of data considered include academic and popular literature, software tools such as GETEM and GEOPHIRES, industry interviews, and analysis conducted by other task forces for the GeoVision Study, e.g., on the drilling costs and reservoir performance.

15 GEOTHERMAL ENERGY↗

Discovering Geothermal Systems in the Great Basin Region: An Integrated Geologic, Geochemical, and Geophysical Approach for Establishing Geothermal Play Fairways

The Great Basin currently hosts ~24 geothermal power plants with more than 600 MW of capacity, but estimates suggest that the region is capable of producing much greater amounts of geothermal energy. Recent studies indicate that a combination of geological, geochemical, and geophysical features characterize the most robust geothermal systems. Considering that most of the geothermal resources in this region are blind, it is imperative that the favorable characteristics for geothermal activity be synthesized and techniques perfected for the discovery of new viable systems. We therefore utilized a multi-disciplinary approach and synthesized 9 geologic, geochemical, and geophysical parameters to produce a new detailed geothermal play fairway map of a large transect across the Great Basin region (96,000 km2) from west-central to eastern Nevada, with the primary objective of facilitating discovery of commercial-grade, blind geothermal fields (i.e. systems with no surface hot springs or fumaroles). Our analysis included: 1) structural settings (i.e., patterns of faulting), 2) age of recent faulting, 3) slip rates on recent faults, 4) regional-scale strain rates, 5) the tendency of faults to slip or dilate based on their orientation in the regional stress field, 6) earthquake density, 7) gravity data, 8) temperature at 3 km depth, and 9) geochemistry from springs and wells. These parameters were grouped into subsets to delineate rankings for local permeability, regional permeability, and heat, which collectively defined the geothermal play fairways (i.e., most likely locations for significant geothermal fluid flow). A major challenge was developing appropriate weightings of individual data types to best predict permeability and overall geothermal potential. Rigorous statistical methods, utilizing 34 benchmarks of known relatively high-temperature (>130°C) geothermal systems in the region, were employed to determine the hierarchal weights of each parameter. The new geothermal potential maps will help to reduce the risks in prospecting for new geothermal systems throughout the region.

15 GEOTHERMAL ENERGY↗

Equitable Access to Community Solar: Program Design and Subscription Considerations

Over 2.7 GWac community solar has been installed in the U.S. as of 2020, and 44% (1.2 GWac ) were installed after 2018, which indicates a fast-growing segment of the solar market .Community solar refers to a system that allows customers to subscribe part of a solar PV system and receive credit on their electricity bills based on power production. Although the growth of community solar market makes accessing solar energy easier, low and moderate income (LMI) potential subscribers may still face challenges, such as no or low credit scores.To investigate the program designs and subscription considerations for LMI customers, we provide a summary of existing state-level low-income community solar policies, as well as estimated LMI capacity and subscribers in the U.S.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Hierarchical Resilience Planning for Networked Microgrids: A Case Study of Puerto Rico

Microgrids can be designed to enhance the energy resilience of communities and critical infrastructures, such as hospitals, data centers, and communication networks, which are vulnerable to frequent weather-related disruption. Coordinating multiple microgrids in a network can leverage the geographical diversity of load and generation resources while enabling resilient and cost-effective planning of the distribution system. Designing a networked microgrid is complex, involving intricate technical assessment, cost-benefit analysis, site-specific requirements, and the evaluation of existing resources. Therefore, this paper proposes a hierarchical resilience planning framework and performs an extensive techno-economic analysis for the design of a networked microgrid. Hierarchical resilience planning involves technology sizing at an individual community level to meet the critical load and satisfy resilience criteria, and resource optimization at networked microgrid level to provide a higher level of resilience and energy adequacy. A real-world case of Puerto Rico's cooperative microgrid “Microrred de la Montaña” is investigated considering localized electricity tariffs, site-specific demand profiles, solar generation, and existing hydro resources. Multiple optimization scenarios are developed based on the resiliency requirement to estimate the capacity of solar photovoltaic and battery energy storage (BES) to be installed at each substation. The results provide the optimal sizing for individual community and networked microgrid to withstand 1day and 3-day outages along with the criteria for critical load.

13 - HYDRO ENERGY↗

Southern Sector Humate Injection Well Performance Testing

Three short duration injection tests were conducted on wells at the humate test site. For each injection event, potable water was gravity drained into the well casing. Pressure response was monitored in the injection well and these data were used to estimate the injection capacity of each well. Injection capacity was calculated by dividing the average injection flow rate by the head increase observed in the injection well. Nearby injection wells were used as observation wells and data from these wells were used to estimate the local hydraulic conductivity. The results of this analysis show that it is hydraulically feasible to gravity inject water into the test wells. The estimated water injection capacity of each well as determined by injecting potable water is shown. It is important to note that these short duration tests utilized water and not the humate solution that will ultimately be injected into the aquifer. The results of these tests do not account for physical or chemical processes that may occur over longer time scales. Injection well performance typically declines over time due to water-chemistry issues, air entrainment, and aquifer clogging. Therefore, these results should be viewed as optimistic estimates of injection capacity. Data from the injection tests were analyzed to estimate local aquifer properties. Transmissivity values for all tests ranged from 0.62 to 1.07 ft 2 /min with an average value of 0.805 ft 2 /min. Hydraulic conductivity was calculated by dividing transmissivity by the aquifer thickness (53 ft). Hydraulic conductivity ranged from 16.7 to 29.2 ft/day with an average value of 21.9 ft/day. Storativity values ranged from 0.0001 to 0.001 with an average value of 0.0006.

54 ENVIRONMENTAL SCIENCES↗

Retention of Cr in Meta-kaolin-based geo-polymeric Materials under Oxidation and Carbonation - 17453

Alkali activated alumino-silicates, often referred to as geo-polymers, are considered promising immobilization matrices for contaminants due to their high sorption capacity, durability and low leachability. For some contaminants they may prove superior to cement pastes that are conventional immobilization materials in waste management applications. However, estimating the retention capacity of some contaminants under environmental conditions that include oxidation and carbonation and may induce a valance change, is complicated. These contaminants tend to be soluble under oxidizing condition and form precipitates under reducing conditions. Thus, contaminant retention is highly dependent on the initial oxidation state at which the metal was introduced, as well as the matrix sorption ability, ability to resist oxidation and carbonation, and the contaminant leachability. Moreover, carbonation in considered one of the most important degradation mechanisms in cementitious material, causing porosity reduction and significant changes in contaminant leachability, however, geo-polymers have considerably lower Ca content relative to cements, or none, and the effect of carbonation on these pastes is less clear. Thus, contaminant release mechanisms and rates must be estimated based upon exposure to various atmospheres appropriate to waste management applications. In this study we aim to estimate the sorption capacity, and leachability of Cr from a meta-kaolin based geo-polymer, doped with Cr, as a function of its oxidation state and carbonation. Cr has a high valance range from +6 to 0 similar to Tc, and is used as its simulant in the current study. Sodium dichromate was used as an oxidized source metal material. To induce reducing conditions, ascorbic acid was added except for experimental control cases. The samples were aged under N{sub 2}, 98% N{sub 2} + 2% CO{sub 2}, CO{sub 2} deficient air and air environments under constant relative humidity. Following aging, samples were subject to equilibrium leaching as a function of pH (EPA Method 1313) and monolith mass transport rate testing (EPA Method 1315). Mass balance calculations, based on the results of a pH dependent leaching test, have shown that oxidized Cr samples lost 85-95% of their Cr content, whereas, the reduced Cr samples lost only 20% of their Cr content. On the other hand, the leachability of Si and Al is much higher in the reduced-Cr samples then in the samples with oxidized Cr, and their natural pH is up to 2.5 pH units lower than that of the oxidizing cases. Thus, we conclude that the combination of the reducing agent and the spike chemistry influence the matrix formation. Sample aging have not resulted in any significant change in the Cr-leaching behavior of the oxidizing matrices in the pH dependent leaching test, although a significant decrease in the natural pH, of 1.5 pH unit, was observed upon exposure to elevated CO{sub 2} levels (2%), probably due to the formation of Na-carbonate species. The pH and leaching behavior of the reduced Cr samples under the various aging conditions have not yielded significant variation either in their natural pH or in their leaching behavior. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ordovician-Cambrian Units: Hierarchical Evaluation of Geologic Carbon Storage Resource Estimates

The Indiana Geological and Water Survey (IGWS) led subtask 1.1 to assess the regional distribution and estimate the storage capacity of Ordovician-Cambrian stratigraphic units located within the partnership region. A comprehensive data set of wireline logs and petrophysical information was used to generate these interpretations. These data include core analysis for porosity and permeability, mercury injection capillary pressure (MICP), and existing well data including location and stratigraphic information. This report includes storage resource estimates (SREs) for three potential storage reservoirs(limestone and dolostone from the Upper Ordovician Trenton Limestone/Black River Group and equivalent units, the Middle Ordovician St. Peter Sandstone, and primary target reservoir rocks of the Lower Ordovician and Upper Cambrian Knox Supergroup and equivalent units) calculated using six methodologies: (1) a fixed value of porosity of 10 percent in all units evaluated; (2) a unique average porosity (per well) from wireline-derived porosity (neutron, sonic, and/or density porosity for each unit); (3) porosity values from core analysis; (4) a depth-dependent porosity model (Knox Supergroup only); (5) porosity based on a model based on petrophysical facies; and (6) SREs using National Energy Technology Laboratory’s CO2 Storage prospeCtive Resource Estimation Excel aNalysis (CO2-SCREEN beta V2). All methods used the same values for thickness for each unit. However, the areal extent of each assessment was limited by the data available for each method. Estimated volumes were calculated in 1-by-1 kilometer grid cells and summarized as county and total stratigraphic unit volumes. The resultant SREs mass are displayed using boxplots, which allow for comparing data statistics (mean values and variability) between methods. Differences observed in SRE results from the six methods are mainly attributable to differences in the data and conceptual models used to interpret or estimate porosity in each method. Based on this systematic variability between methods, it is inferred that methods 1, 4, and 6 are best used for regional-scale reconnaissance estimates of storage capacity while methods 2, 3, and 5 are more appropriate for local scales where more data is required. All estimates are data-density dependent and different methods require different amounts of data for reasonable assessments. ArcMap 10.5.1 software was used to portray SREs to help visualize spatial variance of estimates for each methodology, and more importantly, to highlight those areas having the greatest total storage potential estimates.

01 COAL, LIGNITE, AND PEAT↗

Reduction of hexavalent chromium by fasted and fed human gastric fluid. II. Ex vivo gastric reduction modeling

To extend previous models of hexavalent chromium [Cr(VI)] reduction by gastric fluid (GF), ex vivo experiments were conducted to address data gaps and limitations identified with respect to (1) GF dilution in the model; (2) reduction of Cr(VI) in fed human GF samples; (3) the number of Cr(VI) reduction pools present in human GF under fed, fasted, and proton pump inhibitor (PPI)-use conditions; and (4) an appropriate form for the pH-dependence of Cr(VI) reduction rate constants. Rates and capacities of Cr(VI) reduction were characterized in gastric contents from fed and fasted volunteers, and from fasted pre-operative patients treated with PPIs. Reduction capacities were first estimated over a 4-h reduction period. Once reduction capacity was established, a dual-spike approach was used in speciated isotope dilution mass spectrometry analyses to characterize the concentration-dependence of the 2nd order reduction rate constants. These data, when combined with previously collected data, were well described by a three-pool model (pool 1 = fast reaction with low capacity; pool 2 = slow reaction with higher capacity; pool 3 = very slow reaction with higher capacity) using pH-dependent rate constants characterized by a piecewise, log-linear relationship. These data indicate that human gastric samples, like those collected from rats and mice, contain multiple pools of reducing agents, and low concentrations of Cr(VI) (< 0.7 mg/L) are reduced more rapidly than high concentrations. The data and revised modeling results herein provide improved characterization of Cr(VI) gastric reduction kinetics, critical for Cr(VI) pharmacokinetic modeling and human health risk assessment. - Highlights: • SIDMS allows for measurement of Cr(VI) reduction rate in gastric fluid ex vivo • Human gastric fluid has three reducing pools • Cr(VI) in drinking water at < 0.7 mg/L is rapidly reduced in human gastric fluid • Reduction rate is concentration- and pH-dependent • A refined PK model is used to characterize inter-individual variability in Cr(VI) gastric reduction capacity.

60 APPLIED LIFE SCIENCES↗

Hydropower Energy Storage Capacity (HESC) Dataset

The Hydropower Energy Storage Capacity (HESC) Dataset catalogs characteristics that are relevant to evaluating reservoir storage and estimates of energy storage capacity based on varying levels of detail. Hydropower dams and reservoirs were included based on information from the National Inventory of Dams (NID; USACE, 2021) and Global Reservoir and Dam (GRanD v1.3) and Existing Hydropower Assets datasets. These data provide a foundation for understanding available resources at existing hydropower facilities and their potential to provide storage of energy and more flexible generation. Estimates of energy storage capacity include: • Level 1 – nominal energy storage capacity based on maximum storage capacities and hydraulic head • Level 2 – nominal energy storage capacity based on historical models or observations of reservoir volume and hydraulic head. These estimates are provided based on capacity from the entire historical period as well as monthly values. • Level 3 – modeled energy generation based on volume-elevation relationships, historical storage, observed/modeled inflows, and hydraulic capacity of turbines and calculated both as overall and on a monthly basis. • Level 4 – modeled energy generation incorporating information from Level 3 and operational constraints. For facilities where installed capacity is known, there are also estimates for discharge duration (the length of time when a facility could provide generation at a given capacity).

13 HYDRO ENERGY↗

Pd doped reduced graphene oxide for hydrogen storage

Pd nanoparticles dispersed reduced graphene oxide sample has been prepared by a simple chemical method using hydrazine as the reducing agent. Based on XRD and {sup 13}C MAS NMR studies it is confirmed that, Pd nanoparticles are effectively mixed with the reduced graphene oxide sample. Maximum hydrogen storage capacity has been estimated to be ∼1.36 wt % at 123K. Improved hydrogen storage capacity of Pd incorporated sample can be explained based on the phenomenon of spillover of atomic hydrogen.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Akutan Geothermal: Resource Report

Geothermal energy resources are present in the Hot Springs Bay Valley geothermal area, and the City has invested considerable money and time in the exploration of the resource for future use. Exploration activities funded primarily through a grant the City was awarded from Alaska Energy Authority and later supplemented by the U. S. Department of Energy (DOE), with cost share from the City. The exploration led to the development of a geothermal resource conceptual model that was built and refined between 2008 and 2018. During this period, geological and geophysical studies, exploration drilling and other activities were completed, including a preliminary feasibility study for a power project, investigations of the terrain for suitability for access and development, environmental and archeological review, plus TG well abandonment and a review of economic considerations. The model of the resource predicts that there is a viable geothermal resource in two general areas: on the northwest edge of Hot Springs Bay Valley going northwest of the valley (hot springs area) and southwest of the Valley (fumarole area). The resource temperature for the valley area is expected to be about 170°C (340°F) and given the size and permeability estimates (with a factor for the level of confidence in the estimates), the mean power capacity of the outflow resource is 3 MWe and the P50 (most likely) power capacity is 1 MWe. The fumarole area has an expected resource temperature of 240°C (464°F) and given the size and permeability estimates mean capacity is 20 MWe and the P50 (most likely) capacity is 9 MWe. Permeability is the most difficult factor to predict and has a significant impact on the available geothermal fluids and therefore the amount of power that can be generated. The uncertainty in this value is the main reason for lower confidence in the likelihood of exploration success and the wide range in predicted MW values. The permeability has been difficult to locate as indicated by the results of the flow test at AK-3 in 2017. The test resulted in the production of some fluid, but due to low permeability, the recharge to the wellbore was too slow to sustain flow. The greatest probability of overall MWe production is in the fumarole region, but development is hampered by poor accessibility. The extremely high cost of road building for exploratory drilling, put an end to planning at an intermediate stage of the project and refocused attention on the viability of development in the hot spring outflow part of the resource. The City will be determining what the next steps are with AK-3, which is still that is still open and maintained in a suspended status in HSBV. While AK-3 remains accessible (not plugged with cement) it will need to be maintained. The City has a bond with AOGCC that will remain in place until the well is abandoned. GRG recommends that the well be maintained open as an asset for the foreseeable future.

15 GEOTHERMAL ENERGY↗

Predicting Field Efficiency of Round-Baling Operations in High-Yielding Biomass Crops

Model simulations for bioenergy harvest planning need to utilize equipment-capacity relationships for equipment operating under the high-yield conditions typical of a biomass crop. These performance assumptions have a direct bearing on the estimates of machine capacity, the number of machines required, and, therefore, the cost to fulfill the biorefinery plant demands for a given harvest window. Typically, two major issues in these models have been poorly understood: the available time required to complete the harvest operation (often called probability of workdays) and the capacity of the harvest equipment as impacted by yield. Simulations use annual yield estimates, which incorporate weather events, to demonstrate year-to-year effects. Some simulations also incorporate potential yield increases from genetically modified energy crops. There are limited field performance data for most current forage equipment used for harvesting high-yield biomass crops. Analysis shows that the impact of wrap/eject time for round balers resulted in a 50% reduction in achieved throughput capacity (Mg/h). After the maximum throughput is reached, the cost of the round bale operation (3.23 USD/Mg) is double that of the large-square baler (1.63 USD/Mg). The round baler achieved throughput capacity is 50% less (32.7 Mg/h compared to 71.0 Mg/h) than the large-square baler.

09 BIOMASS FUELS↗

Multiple-beam satellite repeater tradeoffs applied to a multifunctional system.

This paper concerns satellite repeater tradeoffs for a multiple-beam, multiple-channel, multiple-connectivity satellite postulated to serve a diversity of domestic U.S. noncommercial requirements, with a substantial portion of the satellite power, weight, and bandwidth dedicated to video distribution and bradcast. The orders-of-magnitude of the requirements are given for the video plus high-rate data traffic category. The designs of two alternative baseline repeater configurations are presented, and estimates of their weight and their prime power consumption are given. These data are the basis for estimating the weight and power consumption of a range of alternative beam coverage, modulation, and channel capacity systems. These estimates are used to illustrate tradeoffs with different performance criteria as the independent variable: number of channels per beam and total number of beam-channels.

Kinal, G. V.↗

Microwave remote sensing of soil moisture, volume 1

Multifrequency sensor data from NASA's C-130 aircraft were used to determine which of the all weather microwave sensors demonstrated the highest correlation to surface soil moisture over optimal bare soil conditions, and to develop and test techniques which use visible/infrared sensors to compensate for the vegetation effect in this sensor's response to soil moisture. The L-band passive microwave radiometer was found to be the most suitable single sensor system to estimate soil moisture over bare fields. The perpendicular vegetation index (PVI) as determined from the visible/infrared sensors was useful as a measure of the vegetation effect on the L-band radiometer response to soil moisture. A linear equation was developed to estimate percent field capacity as a function of L-band emissivity and the vegetation index. The prediction algorithm improves the estimation of moisture significantly over predictions from L-band emissivity alone.

Mcfarland, M. J.↗

Forecasting battery capacity and power degradation with multi-task learning

Lithium-ion batteries degrade due to usage and exposure to environmental conditions, which affects their capability to store energy and supply power. Accurately predicting the capacity and power fade of lithium-ion battery cells is challenging due to intrinsic manufacturing variances and coupled nonlinear ageing mechanisms. In this paper, we propose a data-driven prognostics framework to predict both capacity and power fade simultaneously with multi-task learning. The model is able to predict the degradation trajectory of both capacity and internal resistance together with knee-points and end-of-life points accurately at early-life stage. The validation shows an average percentage error of 2.37% and 1.24% for the prediction of capacity fade and resistance rise, respectively. The model's ability to accurately predict the degradation, facing capacity and resistance estimation errors, further demonstrates the model's robustness and generalizability. Compared with single-task learning models for forecasting capacity and power degradation, the model shows a significant prediction accuracy improvement and computational cost reduction. This work presents the highlights of multi-task learning in the degradation prognostics for lithium-ion batteries.

25 ENERGY STORAGE↗

Western Sector Injection Well Performance Testing

A total of eight short duration injection tests were conducted on wells at the M-Area Western Sector In-Situ Chemical Oxidation (ISCO) test site. For each injection event, approximately 200 gallons of water were gravity drained into the well casing. Pressure response was monitored in the injection well and these data were used to estimate the injection capacity of each well. Nearby injection wells were used as observation wells and data from these wells were used to estimate local hydraulic conductivity.

47 OTHER INSTRUMENTATION↗