Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cardiac Volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Effects of water immersion to the neck on pulmonary circulation and tissue volume in man

A rapid noninvasive breathing method is used to obtain serial measurements of the pulmonary capillary blood flow, diffusing capacity per unit of alveolar volume, combined pulmonary tissue plus capillary volume, functional residual capacity, and oxygen consumption in five normal subjects undergoing 6 h of sitting, 4 h of sitting while immersed to the neck in thermoneutral water, and 4 h of lying in thermoneutral water to the neck. The rebreathing method employed a test gas mixture containing 0.5% C2H2, 0.3% C(18)O, 10% He, 21% O2, and balance N2. It is shown that immersion to the neck in the seated posture results in significant increases in sodium excretion cardiac output, and diffusing capacity per unit of alveolar volume. The pulmonary tissue plus capillary volume did not change, demonstrating that the central vascular engorgement induced by water immersion is not accompanied by significant extravasation of fluid into the pulmonary interstitial space.

Begin, R.↗

Effect of head-down-tilt bed rest and hypovolemia on dynamic regulation of heart rate and blood pressure

Adaptation to head-down-tilt bed rest leads to an apparent abnormality of baroreflex regulation of cardiac period. We hypothesized that this "deconditioning response" could primarily be a result of hypovolemia, rather than a unique adaptation of the autonomic nervous system to bed rest. To test this hypothesis, nine healthy subjects underwent 2 wk of -6 degrees head-down bed rest. One year later, five of these same subjects underwent acute hypovolemia with furosemide to produce the same reductions in plasma volume observed after bed rest. We took advantage of power spectral and transfer function analysis to examine the dynamic relationship between blood pressure (BP) and R-R interval. We found that 1) there were no significant differences between these two interventions with respect to changes in numerous cardiovascular indices, including cardiac filling pressures, arterial pressure, cardiac output, or stroke volume; 2) normalized high-frequency (0.15-0.25 Hz) power of R-R interval variability decreased significantly after both conditions, consistent with similar degrees of vagal withdrawal; 3) transfer function gain (BP to R-R interval), used as an index of arterial-cardiac baroreflex sensitivity, decreased significantly to a similar extent after both conditions in the high-frequency range; the gain also decreased similarly when expressed as BP to heart rate x stroke volume, which provides an index of the ability of the baroreflex to alter BP by modifying systemic flow; and 4) however, the low-frequency (0.05-0.15 Hz) power of systolic BP variability decreased after bed rest (-22%) compared with an increase (+155%) after acute hypovolemia, suggesting a differential response for the regulation of vascular resistance (interaction, P < 0.05). The similarity of changes in the reflex control of the circulation under both conditions is consistent with the hypothesis that reductions in plasma volume may be largely responsible for the observed changes in cardiac baroreflex control after bed rest. However, changes in vasomotor function associated with these two conditions may be different and may suggest a cardiovascular remodeling after bed rest.

Non-NASA Center↗

Cardiac atrophy after bed-rest deconditioning: a nonneural mechanism for orthostatic intolerance

BACKGROUND: The cardiovascular adaptation to bed rest leads to orthostatic intolerance, characterized by an excessive fall in stroke volume (SV) in the upright position. We hypothesized that this large fall in SV is due to a change in cardiac mechanics. METHODS AND RESULTS: We measured pulmonary capillary wedge pressure (PCWP), SV, left ventricular end-diastolic volume (LVEDV), and left ventricular mass (by echocardiography) at rest, during lower-body negative pressure, and after saline infusion before and after 2 weeks of bed rest with -6 degrees head-down tilt (n=12 subjects aged 24+/-5 years). Pressure (P)-volume (V) curves were modeled exponentially by P=ae(kV)+b and logarithmically by P=-Sln[(Vm-V)/(Vm-V0)], where V0 indicates volume at P=0, and the constants k and S were used as indices of normalized chamber stiffness. Dynamic stiffness (dP/dV) was calculated at baseline LVEDV. The slope of the line relating SV to PCWP during lower-body negative pressure characterized the steepness of the Starling curve. We also measured plasma volume (with Evans blue dye) and maximal orthostatic tolerance. Bed rest led to a reduction in plasma volume (17%), baseline PCWP (18%), SV (12%), LVEDV (16%), V0 (33%), and orthostatic tolerance (24%) (all P<.05). The slope of the SV/PCWP curve increased from 4.6+/-0.4 to 8.8+/-0.9 mL/mm Hg (P<.01) owing to a parallel leftward shift in the P-V curve. Normalized chamber stiffness was unchanged, but dP/dV was reduced by 50% at baseline LVEDV, and cardiac mass tended to be reduced by 5% (P<.10). CONCLUSIONS: Two weeks of head-down-tilt bed rest leads to a smaller, less distensible left ventricle but a shift to a more compliant portion of the P-V curve. This results in a steeper Starling relationship, which contributes to orthostatic intolerance by causing an excessive reduction in SV during orthostasis.

NASA Discipline Cardiopulmonary↗

Effects of cholinergic and beta-adrenergic blockade on orthostatic tolerance in healthy subjects

Cardiovascular responses during a graded lower body negative pressure (LBNP) protocol were compared before and after atropine and propranolol administration to test the hypothesis that both sympathetic and parasympathetic control of cardio-acceleration are associated with syncopal predisposition to orthostatic stress in healthy subjects. Eleven men were categorized into two groups having high (HT, N = 6) or low (LT, N = 5) tolerance based on their total time before the onset of presyncopal symptoms. HT and LT groups were similar in physical characteristics, fitness, and baseline cardiovascular measurements. Atropine treatment had no effect on LBNP tolerance or mean arterial pressure at presyncope, despite an atropine-induced increase in heart rate. Propranolol treatment reduced (p<0.05) LBNP tolerance in both groups. Diminished LBNP tolerance after propranolol administration was associated with reductions in cardiac output, whereas increase in systemic peripheral resistance from baseline to presyncope was unaffected by propranolol. Reduction in cardiac output and LBNP tolerance after beta blockade reflected a chronotropic effect because lower LBNP tolerance for the HT (-50%) and LT (-39%) groups was associated with dramatic reductions (p <0.05) in the magnitude of LBNP-induced tachycardia without significant effects on stroke volume at presyncope. Absence of an atropine-induced difference in cardiac output and systemic peripheral resistance between HT and LT groups failed to support the notion that cardiac vagal withdrawal represents a predominant mechanism that could account for differences in orthostatic tolerance. Because a reduction in LBNP tolerance in both HT and LT groups after propranolol treatment was most closely associated with reduced tachycardia, the data suggest that a primary autonomically mediated mechanism for maintenance of mean arterial pressure and orthostatic tolerance in healthy subjects is beta adrenergic-induced tachycardia.

Non-NASA Center↗

Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow

OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

NASA Discipline Cardiopulmonary↗

Determination of left ventricular volume, ejection fraction, and myocardial mass by real-time three-dimensional echocardiography

Reconstructed three-dimensional (3-D) echocardiography is an accurate and reproducible method of assessing left ventricular (LV) functions. However, it has limitations for clinical study due to the requirement of complex computer and echocardiographic analysis systems, electrocardiographic/respiratory gating, and prolonged imaging times. Real-time 3-D echocardiography has a major advantage of conveniently visualizing the entire cardiac anatomy in three dimensions and of potentially accurately quantifying LV volumes, ejection fractions, and myocardial mass in patients even in the presence of an LV aneurysm. Although the image quality of the current real-time 3-D echocardiographic methods is not optimal, its widespread clinical application is possible because of the convenient and fast image acquisition. We review real-time 3-D echocardiographic image acquisition and quantitative analysis for the evaluation of LV function and LV mass.

NASA Discipline Cardiopulmonary↗

The effects of hindlimb unweighting on the capacitance of rat small mesenteric veins

Microgravity is associated with an impaired cardiac output response to orthostatic stress. Mesenteric veins are critical in modulating cardiac filling through venoconstriction. The purpose of this study was to determine the effects of simulated microgravity on the capacitance of rat mesenteric small veins. We constructed pressure-diameter relationships from vessels of 21-day hindlimb-unweighted (HLU) rats and control rats by changing the internal pressure and measuring the external diameter. Pressure-diameter relationships were obtained both before and after stimulation with norepinephrine (NE). The pressure-diameter curves of HLU vessels were shifted to larger diameters than control vessels. NE (10(-4) M) constricted veins from control animals such that the pressure-diameter relationship was significantly shifted downward (i.e., to smaller diameters at equal pressure). NE had no effect on vessels from HLU animals. These results indicate that, after HLU, unstressed vascular volume may be increased and can no longer decrease in response to sympathetic stimulation. This may partially underlie the mechanism leading to the exaggerated fall in cardiac output and stroke volume seen in astronauts during an orthostatic stress after exposure to microgravity.

Non-NASA Center↗

Transesophageal echocardiographic evaluation of baboons during microgravity induced by parabolic flight

Transthoracic echocardiography (TTE) is a feasible method to noninvasively examine cardiac anatomy during parabolic flight. However, transducer placement on the chest wall is very difficult to maintain during transition to microgravity. In addition, TTE requires the use of low frequency transponders which limit resolution. Transesophical echocardiography (TEE) is an established imaging technique which obtains echocardiographic information from the esophagus. It is a safe procedure and provides higher quality images of cardiac structure than obtained with TTE. This study is designed to determine whether TEE was feasible to perform during parabolic flight and to determine whether acute central volume responses occur in acute transition to zero gravity by direct visualization of the cardiac chambers.

Vernalis, Marina N.↗

Importance of mitral valve repair associated with left ventricular reconstruction for patients with ischemic cardiomyopathy: a real-time three-dimensional echocardiographic study

BACKGROUND: Left ventricular (LV) reconstruction surgery leads to early improvement in LV function in ischemic cardiomyopathy (ICM) patients. This study was designed to evaluate the impact of mitral valve (MV) repair associated with LV reconstruction on LV function 1-year after surgery in ICM patients assessed by real-time 3-dimensional echocardiography (3DE). METHODS AND RESULTS: Sixty ICM patients who underwent the combination surgery (LV reconstruction in 60, MV repair in 30, and revascularization in 52 patients) were studied. Real-time 3DE was performed and LV volumes were obtained at baseline, discharge, 6-month and >or=12-month follow-up. Reduction in end-diastolic volumes (EDV) by 29% and in end-systolic volumes by 38% were demonstrated immediately after surgery and remained at subsequent follow-up (P<0.0001). The LV ejection fraction significantly increased by about 10% at discharge and was maintained >or=12-month (P<0.0001). Although the LV volumes were significantly larger in patients with MV repair before surgery (EDV, 235+/-87 mL versus 193+/-67 mL, P<0.05), they were similar to LV volumes of the patients without MV repair at subsequent follow-ups. However, the EDV increased from 139+/-24 mL to 227+/-79 mL (P<0.01) in 7 patients with recurrent mitral regurgitation (MR). Improvement in New York Heart Association functional class occurred in 81% patients during late follow-up. CONCLUSIONS: Real-time 3DE demonstrates that LV reconstruction provides significant reduction in LV volumes and improvement in LV function which is sustained throughout the 1-year follow-up with 84% cardiac event free survival. If successful, MV repair may prevent LV redilation, while recurrent MR is associated with increased LV volumes.

Clinical Trial↗

Fast interactive real-time volume rendering of real-time three-dimensional echocardiography: an implementation for low-end computers

Real-time three-dimensional echocardiography (RT3DE) is an innovative cardiac imaging modality. However, partly due to lack of user-friendly software, RT3DE has not been widely accepted as a clinical tool. The object of this study was to develop and implement a fast and interactive volume renderer of RT3DE datasets designed for a clinical environment where speed and simplicity are not secondary to accuracy. Thirty-six patients (20 regurgitation, 8 normal, 8 cardiomyopathy) were imaged using RT3DE. Using our newly developed software, all 3D data sets were rendered in real-time throughout the cardiac cycle and assessment of cardiac function and pathology was performed for each case. The real-time interactive volume visualization system is user friendly and instantly provides consistent and reliable 3D images without expensive workstations or dedicated hardware. We believe that this novel tool can be used clinically for dynamic visualization of cardiac anatomy.

NASA Discipline Cardiopulmonary↗

Effects of thermal stress and exercise on blood volume in humans

The available experimental data base on the effects of exercise, posture and the environment (heat) on the blood volume, composition and concentration in humans is surveyed in depth to synthesize supportable conclusions. A large disparity is noted in the effective controls which were initiated in previous experimental conditions, resulting in contradictory findings regarding, e.g., hemoconcentrations and hemodilution in response to exercise. Comparisons between the results of exercise and of supine, seated and upright subjects has underscored the importance of gravity in hemoconcentration, particularly in the legs, and the generation of aldotestosterone. Hemoconcentration has been confirmed to increase with exercise in a seated or supine position. Exercise in a heated environment transfers cardiac output from core areas and reduces filtration efficiencies. Also, plasma volume increases, an action which cannot yet be associated with crystalloidal or colloidal influences on the osmotic behavior of cell walls.

Harrison, M. H.↗

Cardiovascular adaptation to O-G (Experiment 294) - Instrumentation for invasive and noninvasive studies

Many astronauts returning from space have difficulties regulating blood pressure, some to the point of fainting during quiet standing. Experiment 294 was designed to study this and other cardiovascular effects of adaptation to microgravity and to understand the mechanisms behind it. To accomplish this several cardiovascular variables had to be measured accurately. Heart rate, blood pressure, cardiac output (blood pumped by the heart each minute), stroke volume (blood pumped by the heart with each beat), limb flow, limb compliance, heart size and central venous pressure all had to been recorded during various stresses to understand fully the adaptation to space and the readaptation to earth's gravity. Numerous pieces of equipment were used. Some were purpose-built for the Spacelab mission and others were derived from commercial hardware. Developing spaceflight hardware is challenging and costly, but can lead to significant new information in the unique environment of space.

Buckey, Jay C.↗

Pulmonary function in space

The lung is exquisitely sensitive to gravity, and so it is of interest to know how its function is altered in the weightlessness of space. Studies on National Aeronautics and Space Administration (NASA) Spacelabs during the last 4 years have provided the first comprehensive data on the extensive changes in pulmonary function that occur in sustained microgravity. Measurements of pulmonary function were made on astronauts during space shuttle flights lasting 9 and 14 days and were compared with extensive ground-based measurements before and after the flights. Compared with preflight measurements, cardiac output increased by 18% during space flight, and stroke volume increased by 46%. Paradoxically, the increase in stroke volume occurred in the face of reductions in central venous pressure and circulating blood volume. Diffusing capacity increased by 28%, and the increase in the diffusing capacity of the alveolar membrane was unexpectedly large based on findings in normal gravity. The change in the alveolar membrane may reflect the effects of uniform filling of the pulmonary capillary bed. Distributions of blood flow and ventilation throughout the lung were more uniform in space, but some unevenness remained, indicating the importance of nongravitational factors. A surprising finding was that airway closing volume was approximately the same in microgravity and in normal gravity, emphasizing the importance of mechanical properties of the airways in determining whether they close. Residual volume was unexpectedly reduced by 18% in microgravity, possibly because of uniform alveolar expansion. The findings indicate that pulmonary function is greatly altered in microgravity, but none of the changes observed so far will apparently limit long-term space flight. In addition, the data help to clarify how gravity affects pulmonary function in the normal gravity environment on Earth.

short duration↗

A Proposed Study Examining Individual Differences in Temporal Profiles of Cardiovascular Responses to Head Down Tilt During Fluid Loading

Susceptibility of healthy astronauts to orthostatic hypotension and presyncope is exacerbated upon return from spaceflight. The effect of altered gravity during space flight and planetary transition on human cardiovascular function is of critical importance to maintenance of astronaut health and safety. Hypovolemia, reduced plasma volume, is suspected to play an important role in cardiovascular deconditioning following exposure to spaceflight, which may lead to increased peripheral resistance, attenuated arterial baroreflex, and changes in cardiac function. A promising countermeasure for post-flight orthostatic intolerance is fluid loading used to restore lost plasma volume by giving crew salt tablets and water prior to re-entry. The main purpose of the proposed study is to define the temporal profile of cardiac responses to simulated 0-G conditions before and following a fluid loading countermeasure. 8 men and 8 women will be tested during 4 hour exposures at 6o head down tilt (HDT). Each subject will be given two exposures to HDT on separate days, one with and one without fluid loading (one liter of 0.9% saline solution). Stand tests (orthostatic stress) will be done before and after each HDT. Cardiac measures will be obtained with both impedance cardiography and echo ultrasound

Cowings, Patricia↗

Spacelab Life Sciences flight experiments: an integrated approach to the study of cardiovascular deconditioning and orthostatic hypotension

The microgravity environment of spaceflight produces rapid cardiovascular changes which are adaptive and appropriate in that setting, but are associated with significant deconditioning and orthostatic hypotension on return to Earth's gravity. The rapidity with which these space flight induced changes appear and disappear provides an ideal model for studying the underlying pathophysiological mechanisms of deconditioning and orthostatic hypotension, regardless of etiology. Since significant deconditioning is seen after flights of very short duration, muscle atrophy due to inactivity plays, at most, a small role. These changes in circulatory control associated with cephalad fluid shifts, rather than inactivity per se, are probably more important factors. In order to test this hypothesis in a systematic way, a multidisciplinary approach which defines and integrates inputs and responses from a wide variety of circulatory sub-systems is required. The cardiovascular experiments selected for Spacelab Life Sciences flights 1 and 2 provide such an approach. Both human and animal models will be utilized. Pre- and post-flight characterization of the payload crew includes determination of maximal exercise capacity (bicycle ergometry), orthostatic tolerance (lower body negative pressure), alpha and beta adrenergic sensitivity (isoproterenol and phenylephrine infusions), baroreflex sensitivity (ECG-gated, stepwise changes in carotid artery transmural pressure with a pneumatic neck collar), and responses to a 24 h period of 5 deg head-down tilt. Measurements of cardiac output (CO2 and C2H2 rebreathing), cardiac chamber dimensions (phased-array 2-dimensional echocardiography), direct central venous pressure, leg volume (Thornton sock), limb blood flow and venous compliance (occlusion plethysmography), blood and plasma volumes, renal plasma flow and glomerular filtration rates, and various hormonal levels including catecholamines and atrial natriuretic factor will also be obtained. The central venous catheter will be inserted immediately pre-launch and monitored with heart rate and blood pressure in-flight until cardiac output, respiratory gas exchange and quantitative 2D echocardiography measurements can be performed. In-flight hemodynamic measurements will be repeated at rest and during submaximal exercise daily and also during maximal exercise midway through the flight to document the timecourse and extent of cardiovascular changes in the payload crew. Parallel studies are planned for the animals. In addition to measurements of right atrial and aortic pressures and cardiac output, a dorsal micro-circulatory chamber will allow determinations of changes in capillary and venular architecture and function in six of the rats. The techniques and findings from many of the SLS-1 and 2 supporting studies have already yielded significant information about circulatory regulation in patients with both hypo- and hypertension. The flight experiments themselves will provide new data to test the validity of both animal and human models currently used for simulating the fluid shifts of a micro-gravity environment. The development of effective countermeasures, not only for short and long duration space travellers, but also for Earth-bound medical patients can then be physiologically based on experimental data rather than anecdote.

Non-NASA Center↗

Effect of prolonged space flight on cardiac function and dimensions

Echocardiographic studies were performed preflight 5 days before launch and on recovery day and 1, 2, 4, 11, 31 and 68 days postflight. From these echocardiograms measurements were made. From these primary measurements, left ventricular end-diastolic volume, end-systolic volume, stroke volume, and mass were derived using the accepted assumptions. Findings in the Scientist Pilot and Pilot resemble those seen in trained distance runners. Wall thickness measurements were normal in all three crewmembers preflight. Postflight basal studies were unchanged in the Commander on recovery day through 68 days postflight in both the Scientist Pilot and Pilot, however, the left ventricular end-diastolic volume, stroke volume, and mass were decreased slightly. Left ventricular function curves were constructed for the Commander and Pilot by plotting stroke volume versus end-diastolic volume. In both astronauts, preflight and postflight data fell on the same straight line demonstrating that no deterioration in cardiac function had occurred. These data indicate that the cardiovascular system adapts well to prolonged weightlessness and suggest that alterations in cardiac dimensions and function are unlikely to limit man's future in space.

Henry, W. L.↗

An evaluation of the effects of bed rest, sleep deprivation and discontinuance of training on the physical fitness of highly trained young men

This experiment was conducted to determine what physiological effects result when highly trained subjects are confined to bed, deprived of sleep, or allowed to discontinue training. Results indicated: (1) There was a moderate increase in strength variables due to the training in this experiment but the stress which the subjects received caused a negligible change in strength variables. (2) The training program resulted in highly significant changes in specific bicycle ergometer variables indicating good increases in cardiopulmonary fitness. Five days of bed rest or fifty hours of sleep deprivation caused comparable drastic decreases in cardiopulmonary fitness. Post stress the subjects reverted to a normal daily schedule and after two weeks they had recovered about half of what they lost. (3) Cardiac output remains relatively constant at a constant work load, but stroke volume increases with conditioning and decreases with deconditioning due to stress.

Olree, H. D.↗