Search NASA⌕ Search

SEARCH · Search NASA

Results for “CeC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

RECENT PROGRESS IN DYNAMIC PROCESS SIMULATION OF CRYOGENIC REFRIGERATORS

At the CEC 2005 a paper with the title 'Helium refrigerator design for pulsed heat load in Tokamaks' was presented. That paper highlighted the control requirements for cryogenic refrigerators to cope with the expected load variations of future nuclear fusion reactors. First dynamic computer simulations have been presented.In the mean time, the computer program is enhanced and a new series of process simulations are available. The new program considers not only the heat flows and the temperature variations within the heat exchangers, but also the variation of mass flows and pressure drops. The heat transfer numbers now are calculated in dependence of the flow speed and the gas properties. PI-controllers calculate the necessary position of specific valves for maintaining pressures, temperatures and the rotation speed of turbines.Still unsatisfactory is the fact, that changes in the process arrangement usually are attended by adjustments in the program code. It is the main objective of the next step of development a more flexible code which enables that any user defined process arrangements can be assembled by input data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PSO algorithm enhanced with Lozi Chaotic Map - Tuning experiment

In this paper it is investigated the effect of tuning of control parameters of the Lozi Chaotic Map employed as a chaotic pseudo-random number generator for the particle swarm optimization algorithm. Three different benchmark functions are selected from the IEEE CEC 2013 competition benchmark set. The Lozi map is extensively tuned and the performance of PSO is evaluated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extracting symplectic maps for space-charge dominated beams

Symplecticity of transfer maps is important for reliable evaluation of space-charge dominated beams in accelerators. Unfortunately, most simulation codes that include collective effects, such as space charge, do not use canonical phase-space variables and therefore are not symplectic in the presence of electromagnetic fields. In this paper, we present a numerical method to extract local linear symplectic transfer maps using particle tracking simulation code for space-charge dominated beams. We demonstrate this method for the photoinjector (113 MHz SRF gun) section of the Coherent electron Cooling (CeC) Proof of Principle (POP) experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

50-kW 1kV DC bus air-cooled inverter with 1.7 kV SiC MOSFETs and 3D-printed novel power module packaging structure for grid applications

The traditional heatsink design technologies for forced air-cooling and power semiconductors with low junction temperatures have constrained the converters to be designed with massive heatsinks. The low power losses of WBG device technology and higher junction temperature operation over a wide operating range of power have not been fully utilized with liquid-cooled systems. The other major limitation has also been the traditional power module packaging “stack” approach with baseplate. This paper presents a novel power stage design which involves 1.7 kV silicon carbide (SiC) MOSFETs, a heatsink design with Genetic Algorithm (GA) and built using 3D printing technology, and a novel integrated modular power module for high power density. The air-cooled module assembly has a SiC MOSFET phase leg module with split high-side and low-side switches and a gate driver with cross-talk and short circuit protection functions. The heatsink design was modeled using a co-simulation environment with finite element analysis software and GA in MATLAB and COMSOL. The proposed concepts were verified and validated through experiments at each stage of development. The power stage was evaluated at 800V, 900 V, and 1kV for 20 kHz switching frequency and 50-kW load. The experimental results show that the CEC efficiency is 98.4 %. In addition to the efficiency, a power density of 75 W/in 3 was also achieved.

Chinthavali, Madhu Sudhan↗

Use Conditions and Efficiency Measurements of DC Power Optimizers for Photovoltaic Systems

No consensus standard exists for estimating annual conversion efficiency of DC-DC converters or power optimizers in photovoltaic (PV) applications. The performance benefits of PV power electronics including per-panel DC-DC converters depend in large part on the operating conditions of the PV system, along with the performance characteristics of the power optimizer itself. This work presents acase study of three system configurations that take advantage of the capabilities of DC power optimizers. Measured conversion efficiencies of DC-DC converters are applied to these scenarios to determine the annual weighted operating efficiency. A simplified general method of reporting weighted efficiency is given, based on the California Energy Commission's CEC efficiency rating and severalinput / output voltage ratios. Efficiency measurements of commercial power optimizer products are presented using the new performance metric, along with a description of the limitations of the approach.

14 SOLAR ENERGY↗

CCM vs. CRM Design Optimization of a Boost-derived Parallel Active Power Decoupler for Microinverter Applications

Single-phase inverter or rectifier systems often make use of an auxiliary active power decoupler (APD) to balance the mismatch between steady DC power and fluctuating AC power. This paper deals with efficiency and size optimization of a parallel boost-type APD circuit for PV microinverter applications. Specifically, design of an eGaNFET-based, 400 W APD circuit, employing planar inductor and operating in either continuous conduction mode (CCM) or critical conduction mode (CRM) is considered. Available design variables including inductance value, inductor core geometry, capacitor voltage, switching frequency, and modulation scheme (CCM vs. CRM) are explored to identify Pareto-optimal configurations, which can achieve low California Energy Commission (CEC) efficiency drop while also reducing the footprint area of the inductor. The theoretical study predicts that the optimal CRM design can achieve 37% reduced inductor size, while operating with similar efficiency drop, compared to the optimal CCM design. Experimental results, obtained using two separate 40 V, 400 W hardware prototypes for CCM and CRM, are presented to verify the analyses.

14 SOLAR ENERGY↗

Extraction of microbial proteome from soil: potential and limitations assessed through a model study

Proteomics is the study of functions and regulation of biological systems based on the analysis of the protein expression profile, and there is a general agreement that soil proteomics may be a tool for better soil management. Because of the ability of soils to stabilize extracellular proteins by various mechanisms, development of soil proteomics needs an assessment of the efficiency of protein extraction from various soil types. We evaluated the possibility of extraction of soil microbial proteome by inoculating Cupriavidus metallidurans CH34, which has a known proteome, into sterile sand, kaolinite, montmorillonite and a mixture of sand, kaolinite, montmorillonite, goethite and humic acids. One hour after inoculation, the viability of C. metallidurans was determined by the colony-forming units method (CFU), the amount of extracted proteins was determined by the Bradford method and the bacterial proteome was analysed by the two-dimensional gel electrophoresis technique (2D-GE). The bacterial number was 2.5 x 10{sup 6} CFU g{sup -1} of soil in all microcosms, whereas the total extracted protein content varied from 98.1 to 1268 {micro}g g{sup -1} in the various microcosms, but was undetectable in the inoculated montmorillonite. The number of protein spots from the bacterial culture and the inoculated microcosms varied between 317 and 591, with 54 variable spots among the pure culture and the microcosms. No protein spots were detected in the 2D-GE from the montmorillonite microcosm. The 2D-GE of artificial soil microcosms showed a protein pattern that was different from those of pure culture and sand and kaolinite microcosms. The results confirm the importance of clay-specific surface area and CEC in protein adsorption as montmorillonite alone had the largest sorptive capacity, and show that the artificial soil used also had a large sorptive capacity for microbial proteins. Globally, the results indicate that the extraction of proteins from soils is strongly influenced by the clay type and organic matter content, and that poor protein extraction efficiency may reduce the potential of soil proteomics.

54 ENVIRONMENTAL SCIENCES↗

HiPAS GridLAB-D

HiPAS GridLAB-D is the California Energy Commission (CEC) version of GridLAB-D.

Chassin, David P.↗

California Load Flexibility Research and Development Hub (CalFlexhub) v0.1

This repository will host the software, data models and documentation developed as part of the California Energy Commission (CEC) funded California Load Flexibility Research and Development Hub (CalFlexHub) project. The main objectives of CalFlexHub are: - Identify, develop, evaluate, demonstrate and deploy cost-effective, scalable, building load-flexible (LF) technologies that are consistent with building energy efficiency, appliance, and load management standards. - Create a portfolio of LF RDD&D technology projects across various building types and sizes including single-family-residential, multi-family, commercial buildings and integrated campuses. - Deploy LF technologies to demonstrate the ability for 99% of the state's customers to receive the load management standards price and marginal GHG signals.

Prakash, Anand Krishnan↗

HP-FLEX MPC v0.1.0

HP-FLEX MPC is control software developed by Lawrence Berkeley National Laboratory with support from the California Energy Commission (CEC) through EPIC-19-301. HP-FLEX aims to provide load flexibility for heat pumps (HPs) in response to dynamic grid signals (including Time-of-Use, Dynamic Pricing, and Critical Peak Pricing) while maintaining thermostat temperatures within user-specified bounds. The software includes a system-identification module, which models the dynamics of the building envelope with thermostat data, and a control module based on a model predictive controller (MPC) to make optimal decisions. HP-FLEX receives forecasts of outdoor air temperature, solar irradiation, and internal gain (if available), as well as trajectories of energy price, temperature lower and upper bounds over a prediction horizon. It then optimizes heating and cooling capacities to minimize energy cost and peak power (with a user-defined weight on peak power) over the prediction horizon, while maintaining room air temperature within the temperature constraints, and outputs the optimal thermostat setpoints.

Kim, Donghun↗

Guideline 36 Conformance Test v2.0

ASHRAE Guideline 36 provides guidance for how typical commercial building HVAC systems should be controlled to reduce energy costs and improve the indoor environmental quality for occupants. An industry-led effort is developing test scripts for how control manufacturers can test that the control logic in their control products follows Guideline 36. This software intends to support that effort in two ways. First, by providing a testbed for control manufacturers to run the test scripts against their own control products and compare their generated results to the expected results provided by the test scripts. Second, by providing a testbed that can be used during the development of test scripts to rapidly and repeatably verify they exercise Guideline 36 logic as desired and generate accurate expected results that control products can be compared to. An initial version of the software has already been developed and released open-source by a previous CEC-funded project that implemented the first use case (https://github.com/LBNL-ETA/guideline36_conformance_test/blob/master/LICENSE.txt), while this software disclosure will add the functionality of the second use case, as well as update the software where needed, all open-source. We intend to extend and contribute to the existing open-source software repository.

Blum, David [Lawrence Berkeley National Laboratory↗

Reproductive and leaf litterfall fluxes in forest ecosystem sites globally (1950-2022)

Forest allocation of net primary productivity (NPP) to reproduction is poorly quantified globally, despite its critical role in forest regeneration and a well-supported trade-off with allocation to growth. Although field measurements of total NPP are rare, our work finds that a proxy for reproductive carbon allocation constructed from leaf (L) and reproductive (R) litterfall fluxes, R/(R+L), is strongly correlated with R/NPP, facilitating analysis across a wide range of sites where biometric estimates of NPP are not available (R² = 0.85; Hanbury-Brown et al., 2022, Ward et al., in prep). To investigate relationships between ecosystem-scale reproductive allocation (RA) and climate, soil fertility, and stand age gradients, we conducted a literature search and synthesized 824 observations of annual average leaf and reproductive litterfall fluxes across forest sites globally. The zip file includes 1) a folder Data/ containing the litterfall data ("GlobalForestRA_data.csv") and metadata ("GlobalForestRA_metadata.doc") files. The data file includes geographic coordinates, long-term mean annual temperature and precipitation (1970-2000, extracted from WorldClim2.1), leaf and reproductive litterfall fluxes, sampling interval and protocols, forest characteristics (dominant leaf morphology, information pertaining to forest age and successional stage, and disturbance history) and soil properties (% sand, %silt, %clay, total phosphorus (P), nitrogen (N), cation exchange capacity (CEC) and pH) extracted from SoilGrids250 and from on-site measurements, where available. The metadata file contains information about each variable reported in the data file, including data sources, processing methods, and all references. The Data folder contains two additional files used to create Figure 1; these are described in greater detail in the README.2) R scripts GloalForestRA_analysis.r and GlobalForestRA_SI.r and a folder /Functions used to produce results, figures, and tables in the manuscript Ward et al. (in press)3) a README file describing how the data and R scripts can be used to reproduce statistical results, figures, and tables found in the manuscript. Ward et al. (in press)This repository can also be found at: https://github.com/r-ward/Global_Analysis_ForestRA.Ward, R.E., Zhang-Zheng, H. Aernethy, K., Adu-Bredu, S., Arroyo, L., Bailey, A. et al. (in press). Forest age rivals climate to explain reproductive allocation patterns in forest ecosystems globally. Ecology Letters. Hanbury-Brown, A.R., Ward, R.E. & Kueppers, L.M. (2022). Forest regeneration within Earth system models: current process representations and ways forward. New Phytol., 235, 20–40.Ward et al. (2025), Forest age rivals climate to explain reproductive allocation patterns in forest ecosystems globally, in prep.

54 ENVIRONMENTAL SCIENCES↗

Development of an ERL for Coherent Electron Cooling at the Electron-Ion Collider

The Electron-Ion Collider (EIC) is currently under development of to be built at Brookhaven National Lab and requires cooling during collisions in order to preserve the quality of the hadron beam despite degradation due to intra-beam scattering and beam-beam effect. An Energy Recovery Linac (ERL) is being designed to deliver the necessary electron beam for the Coherent electron Cooling (CeC) of the hadron beam, with an electron bunch charge of 1 nC and an average current of 100 mA; two modes of operation are being developed for 150 and 55 MeV electrons, corresponding to 275 and 100 GeV protons. The injector of this SHC-ERL is shared with the Precooler ERL, which cools lower energy proton beams via bunched-beam cooling, as used in Low Energy RHIC electron Cooling (LEReC). This paper reviews the current state of the design.

Accelerator Physics↗

Design of a Microbunched Electron Cooler Energy Recovery Linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55 MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1 nC, an average current of 100 mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Accelerator Physics↗

The ERL-based Design of Electron-Hadron Collider eRHIC

Recent developments of the ERL-based design of future high-luminosity electron-hadron collider eRHIC focused on balancing technological risks present in the design versus the design cost. As a result a lower risk design has been adopted at moderate cost increase. The modifications include a change of the main linac RF frequency, reduced number of SRF cavity types and modified electron spin transport using a spin rotator. A luminosity-staged approach is being explored with a Nominal design ($L \sim 10^{33} {\rm cm}^2 {\rm s}^{-1}$) that employs reduced electron current and could possibly be based on classical electron cooling, and then with the Ultimate design ($L \gt 10^{34} {\rm cm}^{-2} {\rm s}^{-1}$) that uses higher electron current and an innovative cooling technique (CeC). The paper describes the recent design modifications, and presents the full status of the eRHIC ERL-based design.

43 PARTICLE ACCELERATORS↗

DESIGN AND OPTIMIZATION OF AN ERL FOR COOLING EIC HADRON BEAMS

The baseline scheme for hadron beam cooling in the Electron Ion Collider (EIC) calls for Coherent electron Cooling (CeC) of the hadrons with non-magnetized electrons at high energy (150 MeV electrons) and additional cooling via conventional bunched beam cooling using a precooler system. The electron beam parameters for these concepts are at or beyond the current state of the art, with electron bunch charges on the order of 1 nC and average currents on the order of 100 mA and requiring an Energy Recovery Linac (ERL) to produce such beams. Using specifications provided by BNL and JLab, physicists and engineers at Xelera Research are working on a complete design of an ERL system capable of cooling EIC hadrons.

Gulliford, C.↗