Search NASA⌕ Search

SEARCH · Search NASA

Results for “Charged Particle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Charged particle track reconstruction with SπRIT Time Projection Chamber

In this work, we present a software framework, SπRITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the SRIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlapping pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from 132 Sn + 124 Sn collision events with beam energy of 270 AMeV. Particle identification is established using < dE/dx >and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam-energy dependence of correlations between mean transverse momentum and anisotropic flow of charged particles in Au+Au collisions at RHIC

The correlation between the mean transverse momentum, [ p T ], and the squared anisotropic flow, $v^2_n$, on an event-by-event basis has been suggested to be influenced by the initial conditions in heavy-ion collisions. We present measurements of the variances and covariance of [ p T ] and $v^2_n$, along with their dimensionless ratio, for Au+Au collisions at various beam energies: $\sqrt{s_{NN}}$ = 14.6, 19.6, 27, 54.4, and 200 GeV. Our measurements reveal a distinct energy-dependent behavior in the variances and covariances. In addition, the dimensionless ratio displays a similar behavior across different beam energies. We compare our measurements with hydrodynamic models and similar measurements from Pb+Pb collisions at the Large Hadron Collider (LHC). These findings provide valuable insights into the beam energy dependence of the specific shear viscosity ( η/s ) and initial-state effects, allowing for differentiating between different initial-state models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Acceleration of Charged Particles and Formation of Power-law Energy Spectra in Nonrelativistic Magnetic Reconnection

Magnetic reconnection is a primary driver of particle acceleration processes in space and astrophysical plasmas. Understanding how particles are accelerated and the resulting particle energy spectra is among the central topics in reconnection studies. We review recent advances in addressing this problem in nonrelativistic reconnection that is relevant to space and solar plasmas and beyond. We focus on particle acceleration mechanisms, particle transport due to 3D reconnection physics, and their roles in forming power-law particle energy spectra. We conclude by pointing out the challenges in studying particle acceleration and transport in a large-scale reconnection layer and the relevant issues to be addressed in the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Response to “Comment on ‘Modification of Lie's transform perturbation theory for charged particle motion in a magnetic field’” [Phys. Plasmas 30 , 104701 (2023)]

Dr. Brizard's comment on my work is based on a conceived procedure that does not come from my work. The defense of his claim that the modification of the so-called standard Lie's transform theory is unnecessary is also unsupported. This response reveals in detail the inconsistency issues in the so-called standard Lie's transform theory by analyzing both its results and root causes. The problem in the so-called standard Lie's transform theory is beyond the issue to take into account the ordering difference between the guiding center motion and gyromotion. Here, the inconsistent commutation of derivative and limit causes another issue. In addition, the so-called standard Lie's transform formulation leads to an unnecessarily lengthy and tedious derivation process for a one or two page task under the singular (or renormalized) formalism described in my paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionization detail parameters and cluster dose: a mathematical model for selection of nanodosimetric quantities for use in treatment planning in charged particle radiotherapy

Abstract Objective . To propose a mathematical model for applying ionization detail (ID), the detailed spatial distribution of ionization along a particle track, to proton and ion beam radiotherapy treatment planning (RTP). Approach . Our model provides for selection of preferred ID parameters ( I p ) for RTP, that associate closest to biological effects. Cluster dose is proposed to bridge the large gap between nanoscopic I p and macroscopic RTP. Selection of I p is demonstrated using published cell survival measurements for protons through argon, comparing results for nineteen I p : N k , k = 2, 3, …, 10, the number of ionizations in clusters of k or more per particle, and F k , k = 1, 2, …, 10, the number of clusters of k or more per particle. We then describe application of the model to ID-based RTP and propose a path to clinical translation. Main results . The preferred I p were N 4 and F 5 for aerobic cells, N 5 and F 7 for hypoxic cells. Significant differences were found in cell survival for beams having the same LET or the preferred N k . Conversely, there was no significant difference for F 5 for aerobic cells and F 7 for hypoxic cells, regardless of ion beam atomic number or energy. Further, cells irradiated with the same cluster dose for these I p had the same cell survival. Based on these preliminary results and other compelling results in nanodosimetry, it is reasonable to assert that I p exist that are more closely associated with biological effects than current LET-based approaches and microdosimetric RBE-based models used in particle RTP. However, more biological variables such as cell line and cycle phase, as well as ion beam pulse structure and rate still need investigation. Significance . Our model provides a practical means to select preferred I p from radiobiological data, and to convert I p to the macroscopic cluster dose for particle RTP.

Engineering↗

Thin film charged particle detectors

Silicon tracking detectors have grown to cover larger surface areas up to hundreds of square meters, and are even taking over other sub-detectors, such as calorimeters. However, further improvements in tracking detector performance are more likely to arise from the ability to make a low mass detector comprised of a high ratio of active sensor to inactive materials, where dead materials include electrical services, cooling, mechanical supports, etc. In addition, the cost and time to build these detectors is currently large. Therefore, advancements in the fundamental technology of tracking detectors may need to look at a more transformative approach that enables extremely large area coverage with minimal dead material and is easier and faster to build. The advancement of thin film fabrication techniques has the potential to revolutionize the next-to-next generation of particle detector experiments. Some thin film deposition techniques have already been developed and widely used in the industry to make LED screens for TVs and monitors. If large area thin film detectors on the order of several square meters can be fabricated with similar performance as current silicon technologies, they could be used in future particle physics experiments. This paper aims to review the key fundamental performance criteria of existing silicon detectors and past research to use thin films and other semi-conductor materials as particle detectors in order to explore the important considerations and challenges to pursue thin film detectors.

Solid state detectors↗

Novel indium phosphide charged particle detector characterization with a 120 GeV proton beam

Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and radiation hardness. To explore the possibility, promising candidate materials were selected, and particle tracking detectors were fabricated. An indium phosphide detector with a metal-intrinsic-metal structure has been fabricated for particle tracking. The detector was tested using radioactive sources and a high energy proton beam at Fermi National Accelerator Laboratory. In addition to its simplistic design and fabrication process, the indium phosphide particle detector showed a very fast response time of hundreds of picoseconds for the 120 GeV protons, which are comparable to the ultra-fast silicon detectors. This fast-timing response is attributed to the high electron mobility of indium phosphide. Such material properties can be leveraged to build novel detectors with superlative performance.

47 OTHER INSTRUMENTATION↗