Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chemistry diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Effect of boronization on plasma-facing graphite surfaces and its correlation with the plasma behavior in NSTX-U

Boronization is a Plasma Facing Component (PFC) conditioning technique widely used in tokamak machines. The National Spherical Torus Experiment-Upgrade (NSTX-U) applied this conditioning, using a plasma glow with a deuterated Trimethyl-boron (d-TMB) and He mixture. The use of boronization during the campaign improved the plasma performance, allowing longer plasma discharges and H-mode access. The chemical state of an ATJ graphite sample, used as a proxy for the NSTX-U PFCs, was monitored in-situ using the Materials Analysis Particle Probe (MAPP) diagnostic and X-ray Photoelectron Spectroscopy (XPS). The XPS data showed a progressive rise (from + fluence increased. Filterscopes were used to measure the light emitted by oxygen impurities in the plasma near the surface of the PFC. An increase in the registered magnitude of the OII line, normalized to the Dγ intensity, was observed as the concentration of O on the ATJ surface increased. The plasma performance was found to be strongly correlated to oxygen impurity concentrations at the plasma edge and on the PFC surface, as measured by the discharge length and access to the H-mode regime. In this work, we present a quantitative analysis of the evolution of the chemistry of the ATJ surface, and the oxygen presence in the plasma-material interface, and report relevant plasma parameters observed during the same period of time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Investigation of Nanosecond and Subnanosecond Pulsed DBD in Atmospheric Air: Fast Imaging and Spectroscopy

Dielectric barrier discharge (DBD), as an easy and simple way of generation of non-thermal plasma, has found a number of applications in variuos fields. However, development of a homogeneous, or uniform, DBD that would operate at atmospheric pressure conditions in atmospheric air, would open a number of new applications in various fields from thin film coatings to plasma medicine. Unfortunately, at atmospheric pressure, a uniform DBD can be easily transformed into a filamentary dielectric DBD; therefore some serious issues arise, such as gas heating due to strong discharges in the random microdischarge channel and non-uniform energy distribution, which adversely affect applications. These issues traditionally are solved by the use of an appropriate working gas composition, an alternating current driving frequency, lowering of gas pressure, etc. The transitions between discharge modes in the same experimental conditions have been thoroughly investigated in nitrogen, rare gases and their mixtures with air and other gases. In many cases (for example, in plasma medicine), these methods, especially those related to gas composition and pressure, may not be applied in a convenient manner. Recent advances in pulsed power technology permitted application of much faster voltage rise times (including the subnanosecond range) and short (few nanoseconds) pulses, and revealed that uniform DBD can, in fact, be generated in atmospheric air. Such discharges are in the great interest for many applications, however to date there still little understanding of the mechanisms of their operation and characteristics. Currently, there is no adequate model of the uniform dielectric barrier discharge development in atmospheric air. Although extensive studies have been performed on understanding of the nature of the pulsed DBD uniformity, until now there is still little understanding of the mechanism of the DBD transition from the filamentary mode to uniform mode. One of the reasons for this is that development of streamers, and later – filaments, occurs on the sub-nanosecond and nanosecond time scales, and therefore requires imaging and other diagnostic techniques with corresponding speed of registration. Recently developed technologies allow such studies. Here we demonstrate that DBD uniformity strongly depends on applied electric field in the discharge gap. More specifically, the discharge uniformity may be achieved in the case when two conditions are satisfied: (1) stong overvoltage in the discharge gap (provided by fast rise times), when anode-directed streamers are formed, and (2) short pulse duration that prevents discharge overheating due to rising conductivity (current) which leads to formation of filaments. We show that by controlling the applied (global) electric field in ns-pulsed DBD, it is possible to control the uniformity of the discharge. In addition, this offers better control of the discharge chemistry due to local changes of electric fields and therefore electron energy distribution function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Battery aging mode identification across NMC compositions and designs using machine learning

A comprehensive understanding of lithium-ion battery (LiB) lifespan is the key to designing durable batteries and optimizing use protocols. Although battery lifetime prediction methods are flourishing, diagnosis of the root causes of aging and degradation have not yet been well developed nor studied for a broad mixture of designs and use cases. Here, we create a machine-learning (ML)-based framework that distinguishes aging modes using multiple electrochemical signatures recorded cycle-by-cycle. The predominant aging behaviors include a combination of loss of active materials in cathode (LAMPE) and a loss of Li inventory (LLI) in Li plating or solid electrolyte interphase (SEI) formation, manifested from 44 batteries representing two cathode chemistries, two electrode loadings, and five charging rates. Here, the aging mode classification accuracy is 86% using features within the first 50 cycles and increases to 88% beyond 225 cycles. The same features can quantify the percentage of end-of-life LAMPE with only 4.3% of error.

25 ENERGY STORAGE↗

Production of Medically Desirable Radioisotopes in the EIRENE Molten Salt Reactor

Radioisotopes play a vital role in nuclear medicine, enabling the performance of diagnostic procedures such as Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT), in addition to innovative targeted therapies for selectively delivering cytotoxic radiation doses to tumor cells while minimizing damage to healthy tissue [1]. Beta emitting radionuclides such as 90Y and 131I find wide use in radio-immunotherapy, with the radiopharmaceuticals 90Y-ibritumomab tiuxetan (Zevalin®) and 131I-tositumomab (Bexxar®) having received FDA approval for treatment of non-Hodgkin’s lymphoma through targeting the CD20 surface receptor, which is commonly expressed in many B cell non-Hodgkin’s lymphoma subtypes [2, 3]. 90Y has also been successfully applied for treatment of brain tumors [4, 5] and liver cancer [6]. The favorable chelation chemistry of 90Y enables its use with a variety of ligands for the development of radiopharmaceuticals suitable for targeting different carcinoma types [1].

42 - ENGINEERING↗

Effective Hamiltonians derived from equation-of-motion coupled-cluster wave functions: Theory and application to the Hubbard and Heisenberg Hamiltonians

Effective Hamiltonians, which are commonly used for fitting experimental observables, provide a coarse-grained representation of exact many-electron states obtained in quantum chemistry calculations; however, the mapping between the two is not trivial. In this contribution, we apply Bloch’s formalism to equation-of-motion coupled-cluster (EOM-CC) wave functions to rigorously derive effective Hamiltonians in the Bloch’s and des Cloizeaux’ forms. We report the key equations and illustrate the theory by application to systems with two or three unpaired electrons, which give rise to electronic states of covalent and ionic characters. We show that the Hubbard and Heisenberg Hamiltonians can be extracted directly from the so-obtained effective Hamiltonians. By establishing a quantitative connection between many-body states and simple models, the approach facilitates the analysis of the correlated wave functions. We propose a simple diagnostic for assessing the validity of the model space choice based on the overlaps between the target- and model-space states. Finally, artifacts affecting the quality of electronic structure calculations such as spin contamination are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Flashback and Flame-Holding in a Jet-in-Crossflow Mixing Configuration with Methane-Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence diagnostics techniques. The JICF burner has an optically accessible pre-mixing tube allowing the optical diagnostics. The testing was conducted for varied pre-mixer velocities (V) and equivalence ratio (ϕ) for 90%-100% (H2, by mole) H2/CH4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashback events were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to the lower momentum flux ratio which bends the jet sharply, closer toward the injection plane. The mean OH-PLIF images characterized the flame-holding behavior where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port. A Large Eddy Simulation (LES) with detailed chemistry combustion modeling approach was implemented along an OH* sub-mechanism, and it showed qualitative agreement with the integrated line-of-sight chemiluminescence results as well as the planar OH-PLIF measurements.

flame holding↗

Pursuing theranostics: a multimodal architecture approach

Theranostics is a field of nuclear medicine which uses the same targeting vector and chelating system for both a diagnostic and therapeutic radionuclide, allowing for uniformity in imaging and treatment.

Bender, Aidan A. [Nuclear Engineering Program, Uni↗

Desktop Audits: Overview, Case Studies, Guidance

The Energy Independence and Security Act (EISA) of 2007 requires that federal agencies audit 25% of their 3.1 billion square feet of covered facilities each year. Several newer, advanced options such as monitoring-based commissioning, fault detection and diagnostics, and energy management systems can help support data collection and analysis to be used for EISA compliance. The Federal Energy Management Program's (FEMP’s) Audit Decision Tree, Audit Definitions, and FEMP Guidance can be used by Agencies to determine the best approaches to evaluate their facilities. FEMP continues to develop additional resources to support agencies in meeting EISA compliance. This presentation gives an overview of desktop audits, including case studies and guidance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Editorial: Particulate Matter Emissions From Conventional and Reformulated Fuel Combustion: Advances in Experiments and Simulations

Particulate matter (PM or soot) emissions generated by combustion of conventional and reformulated fuels adversely impact the environment and human health (Bond et al., 2013; Landrigan et al., 2018; World Health Organization (WHO), 2016), generating public awareness and motivating efforts towards the mitigation of their harmful effects. Soot formation is one of the most complex phenomena in combustion, involving interactions between combustion chemistry, fluid mechanics, mass/heat transport, and particle dynamics, spanning different spatial and temporal scales. A fundamental understanding of soot formation process is thus necessary to achieve a strong reduction of PM emissions and design cleaner and more efficient combustion systems. This has motivated a longstanding and ongoing research activity aimed at improving our understanding of the physical and chemical processes involved in soot formation, well reviewed in these recent works (Wang and Chung, 2019; Michelsen et al., 2020; Martin et al., 2022). Despite the wide interest, the transition from gas-phase molecules to incipient soot particles is still elusive and the successive particle growth and oxidation processes are far from being fully understood, especially in conditions relevant to real-world applications. Recent advances in combustion PM emission diagnostic and computational capabilities helped in improving the predictability of fundamental chemical and aerosol models for practical applications, thus tackling some of the above-mentioned challenges. The aim of this research topic is to display the ongoing research efforts in addressing the existing gaps on particulate formation from various fuel sources and in conditions typical of practical combustion applications (e.g. flames, engines, pool fires), through both experimental and numerical approaches.

42 ENGINEERING↗

Measurements of Extinct Radionuclides in Filter Paper Samples

Radiochemical diagnostics rely on measurements of short-lived fission product isotopes. Once months to years have passed since isotope formation, the most useful short-lived signatures have decayed away and become extinct. Recent work at our lab has developed new methods to reconstruct the concentrations of extinct radionuclides using mass spectrometry to measure the stable daughter elements formed from radioactive decay. However, the applicability of these techniques to different types of samples has not been fully investigated.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

How Aqueous Solvation Impacts the Frequencies and Intensities of Infrared Absorption Bands in Flavin: The Quest for a Suitable Solvent Model

FTIR spectroscopy accompanied by quantum chemical simulations can reveal important information about molecular structure and intermolecular interactions in the condensed phase. Simulations typically account for the solvent either through cluster quantum mechanical (QM) models, polarizable continuum models (PCM), or hybrid quantum mechanical/molecular mechanical (QM/MM) models. Recently, we studied the effect of aqueous solvent interactions on the vibrational frequencies of lumiflavin, a minimal flavin model, using cluster QM and PCM models. Those models successfully reproduced the relative frequencies of four prominent stretching modes of flavin’s isoalloxazine ring in the diagnostic 1450–1750 cm−1 range but poorly reproduced the relative band intensities. Here, we extend our studies on this system and account for solvation through a series of increasingly sophisticated models. Only by combining elements of QM clusters, QM/MM, and PCM approaches do we obtain an improved agreement with the experiment. The study sheds light more generally on factors that can impact the computed frequencies and intensities of IR bands in solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WFOT: A Wave Function Overlap Tool between Single- and Multi-Reference Electronic Structure Methods for Spectroscopy Simulation

We report the development of a novel diagnostic tool, named wave function overlap tool (WFOT), designed to evaluate the overlap between wave functions computed at single-reference [i.e., time-dependent density functional theory or configuration interaction singles (CIS)] and multireference (i.e., CASSCF/CASPT2) electronic structure levels of theory. It relies on truncating the single- and multireference WFs to CIS-like expansions spanning the same configurational space and maximizing the molecular orbital overlap by means of a unitary transformation. To demonstrate the functionality of the tool, we calculate the transient spectrum of acetylacetone by evaluating excited state absorption signals with multireference quality on top of single-reference on-the-fly dynamics simulations. Semiautomatic spectra generation is facilitated by interfacing the tool with the COBRAMM package, which also allows one to use WFOT with several quantum chemistry codes such as Gaussian, NWChem, and OpenMolcas. Finally, other exciting possibilities for the utilization of the code beyond the simulation of transient absorption spectroscopy are eventually discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Analytical Methodology for Chloride Molten Salt Reactor Safeguards and Process Monitoring

Technologies that enable near real-time isotopic analysis of advanced molten salt reactor (MSR) fuels are critically needed to safeguard these reactors, increase their operational efficiency, and enable their widespread deployment with confidence. We present a systematic approach to developing near real-time dissolution and chemical isolation of U, Pu, and major fission products from highly radioactive chloride molten salt samples. Chemical yields greater than 95% were observed for both uranium and the lanthanides. Interference reduction enabled the detection and quantification of key diagnostic isotopes (including 112Ag, 147Nd, and 153Sm) that were previously undetectable in the original sample. The results from this initial scoping study lay the foundation for the development of future automated systems that can enable cost-efficient, near-real time chemical separation and analysis of extremely highly radioactive molten salt samples.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

The Liquid Jet Endstation for Hard X-ray Scattering and Spectroscopy at the Linac Coherent Light Source

The ability to study chemical dynamics on ultrafast timescales has greatly advanced with the introduction of X-ray free electron lasers (XFELs) providing short pulses of intense X-rays tailored to probe atomic structure and electronic configuration. Fully exploiting the full potential of XFELs requires specialized experimental endstations along with the development of techniques and methods to successfully carry out experiments. The liquid jet endstation (LJE) at the Linac Coherent Light Source (LCLS) has been developed to study photochemistry and biochemistry in solution systems using a combination of X-ray solution scattering (XSS), X-ray absorption spectroscopy (XAS), and X-ray emission spectroscopy (XES). The pump–probe setup utilizes an optical laser to excite the sample, which is subsequently probed by a hard X-ray pulse to resolve structural and electronic dynamics at their intrinsic femtosecond timescales. The LJE ensures reliable sample delivery to the X-ray interaction point via various liquid jets, enabling rapid replenishment of thin samples with millimolar concentrations and low sample volumes at the 120 Hz repetition rate of the LCLS beam. This paper provides a detailed description of the LJE design and of the techniques it enables, with an emphasis on the diagnostics required for real-time monitoring of the liquid jet and on the spatiotemporal overlap methods used to optimize the signal. Additionally, various scientific examples are discussed, highlighting the versatility of the LJE.

EXAFS↗

Chelating Rare-Earth Metals (Ln 3+ ) and 225 Ac 3+ with the Dual-Size-Selective Macrocyclic Ligand Py 2 -Macrodipa

Radioisotopes of metallic elements, or radiometals, are widely employed in both therapeutic and diagnostic nuclear medicine. For this application, chelators that efficiently bind the radiometal of interest and form a stable metal–ligand complex with it are required. Toward the development of new chelators for nuclear medicine, we recently reported a novel class of 18-membered macrocyclic chelators that is characterized by their ability to form stable complexes with both large and small rare-earth metals (Ln 3+ ), a property referred to as dual size selectivity. A specific chelator in this class called py-macrodipa, which contains one pyridyl group within its macrocyclic core, was established as a promising candidate for 135 La 3+ , 213 Bi 3+ , and 44 Sc 3+ chelation. Building upon this prior work, here we report the synthesis and characterization of a new chelator called py 2 -macrodipa with two pyridyl units fused into the macrocyclic backbone. Its coordination chemistry with the Ln 3+ series was investigated by NMR spectroscopy, X-ray crystallography, density functional theory (DFT) calculations, analytical titrations, and transchelation assays. These studies reveal that py 2 -macrodipa retains the expected dual size selectivity and possesses an enhanced thermodynamic affinity for all Ln 3+ compared to py-macrodipa. By contrast, the kinetic stability of Ln 3+ complexes with py 2 -macrodipa is only improved for the light, large Ln 3+ ions. Based upon these observations, we further assessed the suitability of py 2 -macrodipa for use with 225 Ac 3+ , a large radiometal with valuable properties for targeted α therapy. Radiolabeling and stability studies revealed py 2 -macrodipa to efficiently incorporate 225 Ac 3+ and to form a complex that is inert in human serum over 3 weeks. Although py 2 -macrodipa does not surpass the state-of-the-art chelator macropa for 225 Ac 3+ chelation, it does provide another effective 225 Ac 3+ chelator. Furthermore, these studies shed light on the fundamental coordination chemistry of the Ln 3+ series and may inspire future chelator design efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlating the Morphological Changes to Electrochemical Performance During Carbon Corrosion in Polymer Electrolyte Fuel Cells

A mechanistic understanding of carbon corrosion in polymer electrolyte fuel cells (PEFCs) is required to design durable catalyst layers. Uncontrolled startup and shutdown of PEFCs cause electrochemical oxidation of carbon, which leads to several degradation phenomena, such as loss in electrochemical surface area (ECSA), pore structure collapse or increase in mass transport resistance. In this study, the chronology of morphological changes in the cathode catalyst layer due to carbon corrosion was identified and correlated with electrochemical performance degradation. PEFCs were subjected to the Department of Energy carbon corrosion accelerated stress test (AST) protocol. The study revealed two phases: in the initial phase (~500 AST cycles), amorphous carbon in contact with Pt nanoparticles oxidized fast. Rapid carbon loss and catalyst layer thinning occurred, but pore structure did not change significantly. Pt nanoparticles detached from the support and ECSA decreased drastically. In the second phase (~1500 AST cycles), carbon corrosion slowed down, but severe pore structure collapse was observed. Porosity and pore connectivity within the cathode catalyst layer decreased considerably. Electrochemical diagnostics corroborated this finding by showing significantly higher O2 mass transport resistance. Lastly, no significant change was observed in the concentration of oxides on the carbon surface after AST. But overall water management in the cathode catalyst layer deteriorated as the pore structure collapsed. This study provides an in-depth understanding of morphological changes during PEFC carbon corrosion AST protocol and motivates novel material design strategies to enable durable PEFCs.

catalyst layers↗

Time and space resolved diagnostics for plasma thermal-chemical instability of fuel oxidation in nanosecond plasma discharges

Here, an instability in a nanosecond pulsed dielectric barrier discharge plasma occurring in methane–oxygen–argon mixtures is experimentally observed and measured by 1D time-resolved in situ electric field measurements. This instability, which seems to be created by the positive feedback between plasma kinetics and plasma-assisted low temperature fuel oxidation, is studied using electric field induced second harmonic generation and direct ICCD imaging. The rapid formation of streamers from an originally uniform discharge appears to be caused by the chemical kinetics of plasma-assisted low temperature methane oxidation, which may be resulting in a new type of plasma instability: a thermal-chemical instability. The results also revealed that the occurrence of this possible thermal-chemical instability in a reactive flow drastically changes the plasma properties by forming multiple secondary discharges and possibly leads to micron-sized non-uniform electric distributions. Single shot uncalibrated measurements of the electric field of the micron sized streamers appears to show much greater strengths than the average electric field. Furthermore, one-dimensional data analysis shows the positive feedback loop between the streamers and the low temperature plasma assisted oxidation chemistry in the plasma thermal-chemical instability. The present finding advances the understanding plasma instability growth and provides a new way to control plasma uniformity in plasma-assisted combustion and plasma fuel reforming.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and synthesis of astatinated benzothiazole compounds for their potential use in Targeted Alpha Therapy (TAT) strategies to treat Alzheimer's disease-associated amyloid plaques

Alzheimer's disease (AD) is a terminal neurodegenerative disease characterized by the buildup of amyloid fibrils, amorphous aggregates and tauopathies. Several treatment modalities, which rely on various biological processes to reduce disease burden, have been largely ineffective at treating Alzheimer's disease. Targeted alpha therapy (TAT) has demonstrated positive results in the treatment of cancer. Benzothiazole derivatives have been successfully shown to target these plaques and are used in several imaging applications. One such derivative, Flutemetamol (Vizamyl TM ) is an FDA approved diagnostic tool for PET imaging of AD-associated plaques. We report the radiolabeling of benzothiazole derivatives with 211 At, a 7.2 h alpha emitting radionuclide, using a copper catalyzed reaction with a boronic acid precursor molecule. In conclusion, our final compound [ 211 At]3'-At-PIB-OMe had a radiochemical yield of 55% and was found to be stable for at least 3 h in phosphate buffered saline.

62 RADIOLOGY AND NUCLEAR MEDICINE↗