Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chromate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

High Contrast Internal and External Coronagraph Masks Produced by Various Techniques

Masks for high contrast internal and external coronagraphic imaging require a variety of masks depending on different architectures to suppress star light. Various fabrication technologies are required to address a wide range of needs including gradient amplitude transmission, tunable phase profiles, ultra-low reflectivity, precise small scale features, and low-chromaticity. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks, and lab-scale external occulter type masks by various techniques including electron beam, ion beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each. Further development is in progress to produce circular masks of various kinds for obscured aperture telescopes.

Phase Induced Amplitude Apodization Complex Mask C↗

Recent Space PV Concentrator Advances: More Robust, Lighter, and Easier to Track

Over the past three years, the authors have collaborated on several significant advances in space photovoltaic concentrator technology, including a far more robust Fresnel lens for sunlight concentration, improved color-mixing features for the lens to minimize chromatic aberration losses for next-generation 4-junction and 6-junction IMM cells, a new approach to suntracking requiring only one axis of rotation even in the presence of large beta angles (e.g., +/- 50 deg), a new waste heat radiator made of graphene, with 80-90% reduction in mass, and a new platform for deployment and support on orbit (SOLAROSA). These patent-pending advances are described in this paper.

concentrators↗

A Learning Model for L/M Specificity in Ganglion Cells

An unsupervised learning model for developing LM specific wiring at the ganglion cell level would support the research indicating LM specific wiring at the ganglion cell level (Reid and Shapley, 2002). Removing the contributions to the surround from cells of the same cone type improves the signal-to-noise ratio of the chromatic signals. The unsupervised learning model used is Hebbian associative learning, which strengthens the surround input connections according to the correlation of the output with the input. Since the surround units of the same cone type as the center are redundant with the center, their weights end up disappearing. This process can be thought of as a general mechanism for eliminating unnecessary cells in the nervous system.

Ahumada, Albert J.↗

Design of Off-Axis PIAACMC Mirrors

The Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) provides an efficient way to control diffraction propagation effects caused by the central obstruction/segmented mirrors of the telescope. PIAACMC can be optimized in a way that takes into account both chromatic diffraction effects caused by the telescope obstructed aperture and tip/tilt sensitivity of the coronagraph. As a result, unlike classic PIAA, the PIAACMC mirror shapes are often slightly asymmetric even for an on-axis configuration and require more care in calculating off-axis shapes when an off-axis configuration is preferred. A method to design off-axis PIAA mirror shapes given an on-axis mirror design is presented. The algorithm is based on geometrical ray tracing and is able to calculate off-axis PIAA mirror shapes for an arbitrary geometry of the input and output beams. The method is demonstrated using the third generation PIAACMC design for WFIRST-AFTA (Wide Field Infrared Survey Telescope-Astrophysics Focused Telescope Assets) telescope. Geometrical optics design issues related to the off-axis diffraction propagation effects are also discussed.

Exoplanets↗

Space Photovoltaic Concentrator Using Robust Fresnel Lenses, 4-Junction Cells, Graphene Radiators, and Articulating Receivers

At the 42nd PVSC, our team presented recent advances in our space photovoltaic concentrator technology. These advances include more robust Fresnel lenses for optical concentration, more thermally conductive graphene radiators for waste heat rejection, improved color-mixing lens technology to minimize chromatic aberration losses with 4-junction solar cells, and an articulating photovoltaic receiver enabling single-axis sun-tracking, while maintaining a sharp focal line despite large beta angles of incidence. In the past year, under a NASA Phase II SBIR program, our team has made much additional progress in the development of this new space photovoltaic concentrator technology, as described in this paper.

photovoltaic↗

A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

contrast sensitivity↗

Sensitivity of WFIRST Coronagraph Broadband Contrast Performance to DM Actuator Errors

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory (JPL), we have investigated the sensitivity of a Hybrid Lyot Coronagraph (HLC) broadband contrast performance to DM actuator errors and actuator limits. Considered case include drifts in actuator gains or actuator response curves, paired actuators, as well as the limits imposed by a neighboring-actuator rule. Actual data about the actuator drifts and the knowledge about the paired-actuators obtained in several DM characterization experiments conducted at JPL, as well as the neighboring-actuator rule implemented on the OMC testbed were used in simulations. We obtained good agreement between the model prediction and the testbed measurement in terms of static HLC contrast floor and contrast chromaticity.

Sidick, Erkin↗

Wavefront Control Performance Modeling with WFIRST Shaped Pupil Coronagraph Testbed

NASA’s WFIRST mission includes a coronagraph instrument (CGI) for direct imaging of exoplanets. Significant improvement in CGI model fidelity has been made recently, alongside a testbed high contrast demonstration in a simulated dynamic environment at JPL. We present our modeling method and results of comparisons to testbed’s high order wavefront correction performance for the shaped pupil coronagraph. Agreement between model prediction and testbed result at better than a factor of 2 has been consistently achieved in raw contrast (contrast floor, chromaticity, and convergence), and with that comes good agreement in contrast sensitivity to wavefront perturbations and mask lateral shear.

Zhou, Hanying↗

Keck Segment Surface Artifacts: Impacts on Segment Phasing and Image Quality

We show that the segments of the Keck telescopes su er from small but signi cant surface artifacts that limit segment phasing accuracy. Both the segment surface artifacts themselves and the limits they place on segment phasing have important implications for adaptive optics, high contrast imaging, and seeing limited observations. These surface artifacts are likely by-products of the segment polishing, most likely the Ion Beam Figuring (IBF) process that constitutes the nal step of the segment surface guring. The surface artifacts di ract a signi cant amount of light out past 3.5 arcseconds and generate chromatic e ects that limit segment phasing accuracy. We present on-sky measurements of the di racted intensity. Segment surface roughness measurements are also presented, which show that surface roughness is not the source of the problem. These results have direct relevance to segment manufacturing for the Thirty Meter Telescope (TMT) and other segmented mirror telescopes.

Brock, Neal↗

WFIRST Coronagraph: Digging Dark-Holes with Partially Corrected Pupil Phase

The WFIRST coronagraph employs two sequential deformable mirrors to compensate for phase and amplitude errors in the coronagraph optical system. In such a system the actuators of the deformable mirrors would be used for two purposes: To flatten the overall wavefront errors at a system pupil, and to create "dark-holes". The actuators have limited stroke ranges. Therefore, if the pupil phase errors are relatively large, flattening them completely could use up a significant portion of the actuator stroke, sometimes leaving insufficient stroke for creating the dark-holes. We have investigated the impact of partially-corrected pupil phase errors on a Hybrid Lyot Coronagraph (HLC) broadband contrast performance. The predicted broadband contrast floor and the contrast chromaticity agree well with those measured on the HLC testbed.

Poberezhskiy, Ilya↗

Modeling the Uptake of Hydrogen Chloride onto Interior Spacecraft Materials

Hydrogen chloride (HCl) is a major combustion product from the pyrolysis of polyvinyl chloride (PVC) insulated electrical wires, a common spacecraft fire safety concern. Models at two different scales were developed to predict HCl uptake on anodized, chromate conversion coated (Iridite), and bare aluminum surfaces, as well as on Nomex fabric: a macroscopic one-step global surface reaction model where all the active sites are on the exterior surface, and a pore model where the interior active sites deeper into the oxide layer can also be accessed by HCl. Experiments were performed to calibrate kinetic and diffusion constants in the models. A cast acrylic test cell was used to measure the differences between the inlet and outlet concentration of HCl after inserting a sample rod of the test material. For the materials with a thin (< 200 µm) or no oxide layer, the macroscopic surface reaction model adequately predicts the experimental measurements. For the anodized aluminum with a thicker oxide layer, the pore model provided a better match to experimental results. The results will be discussed with respect to the spacecraft fire safety project (Saffire).

modeling↗

The Late-time Afterglow Evolution of Long Gamma-Ray Bursts GRB 160625B and GRB 160509A

We present post-jet-break Hubble Space Telescope, Very Large Array, and Chandra observations of the afterglow of the long γ-ray bursts GRB 160625B (between 69 and 209 days) and GRB 160509A (between 35 and 80 days). We calculate the post-jet-break decline rates of the light curves and find the afterglow of GRB 160625B is inconsistent with a simple t−3/4 steepening over the break, expected from the geometric effect of the jet edge entering our line of sight. However, the favored optical post-break decline (fv alpha t-1.96+-0.07) is also inconsistent with the fν alpha t−p decline (where p ≈ 2.3 from the pre-break light curve), which is expected from exponential lateral expansion of the jet; perhaps suggesting lateral expansion that only affects a fraction of the jet. The post break decline of GRB 160509A is consistent with both the t−3/4 steepening and with fν alpha t−p. We also use BOXFIT to fit afterglow models to both light curves and find both to be energetically consistent with a millisecond magnetar central engine, but the magnetar parameters need to be extreme (i.e., E ~ 3 × 1052 erg). Finally, the late-time radio light curves of both afterglows are not reproduced well by BOXFIT and are inconsistent with predictions from the standard jet model; instead, both are well represented by a single power-law decline (roughly fν alpha t−1) with no breaks. This requires a highly chromatic jet break (tj, radio > 10 x tj, optical) and possibly a two-component jet for both bursts.

Gamma-ray bursts↗

Mapping Temperate Forest Phenology Using Tower, UAV, and Ground-Based Sensors

Phenology is a distinct marker of the impacts of climate change on ecosystems. Accordingly, monitoring the spatiotemporal patterns of vegetation phenology is important to understand the changing Earth system. A wide range of sensors have been used to monitor vegetation phenology, including digital cameras with different viewing geometries mounted on various types of platforms. Sensor perspective, view-angle, and resolution can potentially impact estimates of phenology. We compared three different methods of remotely sensing vegetation phenology—an unoccupied aerial vehicle (UAV)-based, downward-facing RGB camera, a below-canopy, upward-facing hemispherical camera with blue (B), green (G), and near-infrared (NIR) bands, and a tower-based RGB PhenoCam, positioned at an oblique angle to the canopy—to estimate spring phenological transition towards canopy closure in a mixed-species temperate forest in central Virginia, USA. Our study had two objectives: (1) to compare the above- and below-canopy inference of canopy greenness (using green chromatic coordinate and normalized difference vegetation index) and canopy structural attributes (leaf area and gap fraction) by matching below-canopy hemispherical photos with high spatial resolution (0.03 m) UAV imagery, to find the appropriate spatial coverage and resolution for comparison; (2) to compare how UAV, ground-based, and tower-based imagery performed in estimating the timing of the spring phenological transition. We found that a spatial buffer of 20 m radius for UAV imagery is most closely comparable to below-canopy imagery in this system. Sensors and platforms agree within +/− 5 days of when canopy greenness stabilizes from the spring phenophase into the growing season. We show that pairing UAV imagery with tower-based observation platforms and plot-based observations for phenological studies (e.g., long-term monitoring, existing research networks, and permanent plots) has the potential to scale plot-based forest structural measures via UAV imagery, constrain uncertainty estimates around phenophases, and more robustly assess site heterogeneity.

Jeff W. Atkins↗

Combined Experimental and Modeling Study of the Interactions of Acid Gas with Common Spacecraft Surfaces for Fire Safety Applications

A fire in a spacecraft poses detrimental consequences and risks mission success in addition to crew safety. This is compounded during long-duration missions when the crew has limited options to recover from a fire. A common spacecraft fire concern is the smoldering of wire insulation, typically made from Polyvinyl chloride (PVC) or Polytetrafluoroethylene (PTFE). This creates acid gases such as Hydrogen Chloride (HCl), Hydrogen Fluoride (HF) and Hydrogen Cyanide (HCN). These poisonous gases are hazardous to the crew. They also interact with common surfaces within the spacecraft more than dominant combustion products such as CO2 and H2O. This makes them more difficult to track for potential fire detection techniques, or for postfire clean-up. It is imperative to be able to understand and predict the fate of these poisonous species in a microgravity environment in order to design a safe vehicle. HCl interacts with a number of materials inside a spacecraft. Primary among these materials is aluminum, which is abundantly used due to its strong and light weight nature. Aluminum has a natural oxide layer that protects it from corrosion but is typically treated to enhance this oxide layer. Among these treatments is a chromate conversion coating (CCC), which provides a thin enough protective oxide layer to still conduct electricity, and a traditional anodized material that has a thicker oxide layer that does not conduct electricity. Nomex is another common material found inside a spacecraft. It is a flame-resistant woven polymer that is related to nylon. This commercially available material is used for cargo storage bags and as a fire barrier. Physics-based models were developed to predict the uptake of HCl by these materials. The ultimate objective of these models is to predict the fate of HCl within the spacecraft so that sensors can be placed in meaningful locations in future missions based on the model predictions. To support these modeling efforts, experiments were performed in a cast acrylic test cell that measured the difference between the inlet and outlet concentration of HCl after inserting a sample rod of the test material. Different uptake capacities were realized for each type of sample tested. A computational fluid dynamics model (CFD) model of the reactor was then constructed that used a one-step global reaction rate with calibratable reaction (or kinetic) constants. These constants were calibrated to match the HCl uptake on the CCC aluminum samples, and the same kinetic constants were then tested for the stock and anodized aluminum samples. Model predictions matched the experimental data for the stock aluminum, and to a much lesser extent, the anodized aluminum. The model was additionally validated at different flow rates, sample surface areas, and inlet concentrations, and showed good agreement for all stock and CCC samples. The model did not accurately predict the HCl uptake in the anodized samples compared to the other two types of aluminum. Adjusting the kinetic constants and transport properties did little to improve the prediction. X-Ray Photoelectron Spectroscopy (XPS) was used to determine that the oxide layer thickness of anodized aluminum is approximately 5,000 nm, compared to 250 nm for CCC and 50 nm for stock. XPS also revealed presence of chlorine further down in the aluminum oxide layer in anodized samples than CCC and stock samples after the samples were saturated with HCl, indicating that accounting for diffusion of HCl into the oxide layer is important for accurate prediction of HCl uptake onto anodized aluminum. Consequently, a multi-scale model was developed and tested. First, a single pore inside the anodized aluminum oxide layer was modeled and is referred to as the pore-scale model. In this model, HCl diffused through the pore and reacted with the aluminum oxide pore wall to create aluminum chloride. The sample was then saturated when the mass transfer resistance through the growing aluminum chloride layer became too large for the HCl to reach the aluminum oxide wall and continue the reaction. This pore-scale model was coupled to the reactor-scale model using a concentration-dependent diffusion coefficient, resulting in much more accurate predictions (approximately half the sum square error of the aforementioned reactor-scale model that produced good agreement for stock and CCC) for a variety of operating conditions. The amount of water vapor or relative humidity (RH) in the flow during a reactor experiment was determined to influence HCl uptake. Experiments were performed to understand the interaction of gaseous HCl with aluminum surfaces in the presence of water vapor. The results show that increasing levels of RH increased the capacity of aluminum to adsorb HCl but decreased the capacity of Nomex to uptake HCl. A series of tests were performed on individual aluminum samples after they had been saturated with a fixed concentration of HCl in dry air conditions with the goal of determining how their HCl uptake capacity changes after various treatments with water relative to the original saturation tests. HCl-saturated aluminum samples subjected to a second dry air flow at the same HCl concentration as the original test had an uptake of 23.5% of the original sample with no treatment in between. Saturated aluminum samples subjected to an air flow with a RH of 90% in between tests had an uptake of 35.6% of the original. Saturated aluminum samples submerged in distilled water for 12 hours in between tests had an uptake of 82.2% of the original sample. Previously saturated aluminum tested with HCl and a 50% RH air flow resulted in similar uptake characteristics in multiple repeated tests. The experiments show the profound effect water vapor has on HCl uptake onto aluminum surfaces. In the samples subjected to water vapor or liquid water, capillary condensation and capillary diffusion alters the transport of HCl significantly. A model was proposed that developed a relationship between RH and the coefficient of HCl diffusion in aluminum chloride. This produced an “S-shaped” curve with diffusion coefficient as a function of RH, with 45% RH represented as the point where the diffusion coefficient is halfway between no water saturation and 100% water saturation in the aluminum chloride product layer. No difference in uptake characteristics for the experiment or model were realized between 50% and 62% RH. The results from the large-scale microgravity experiment, Saffire, are discussed as they pertain to the fate of HCl throughout a spacecraft. HCl was released, both as a standalone event, and in concurrence with the burning of a structured cloth. These events only produced a small response in the far field HCl sensor, while a PMMA burn that did not produce HCl had a significantly greater response. A ground-based large-scale facility was constructed to flow acid gas at the scale and configuration realized in the Saffire experiments. A CFD model of this duct was constructed to test kinetic parameters developed in this work at a larger scale and different geometric configuration and to predict the results of the large-scale facility. The models developed in this work were used to interpret the results of the microgravity tests and lead the discussion on what further experiments and models are needed in order to predict the fate of acid gas in a spacecraft environment. To summarize, the major contributions of this work are as follows: the capacity to uptake HCl, with and without the presence of water vapor, was measured for a variety of real spacecraft surfaces. Several different models (single reactor-scale, multiscale, spacecraft-scale) were developed and with the aid of modeling, the rate of uptake for those surfaces was also predicted and validated. The kinetic parameters determined from the small-scale reactor experiments and models were used to predict large-scale and microgravity tests. Conclusions from this research will be used in the design of spacecraft vehicles and large-scale microgravity fire safety experiments. The models built by this work will aid designers in sensor placement and could be used to predict acid gas transport from fires in partial gravity, as would be seen in Lunar and Martian habitats.

fire safety↗

Linking Strategic Astrophysics Missions, Technology Gaps, and Technology Maturation Investments

The National Aeronautics and Space Administration’s (NASA) Astrophysics Division (APD) funds the development of cutting-edge technologies through multiple programs to enable its strategic missions to achieve ambitious and groundbreaking science goals. These technology development efforts are managed by the Cosmic Origins (COR), Exoplanet Exploration (ExE), and Physics of the Cosmos (PhysCOS) programs. The 2020 Astronomy and Astrophysics Decadal Survey, “Pathways to Discovery in Astronomy and Astrophysics for the 2020s,” (Astro2020) recommended a pan-chromatic set of missions, including three Great Observatories (GO) and three Probe-class missions that could collect unprecedented data over the coming decades. We show the correlation between these strategic missions and the current Astrophysics technology gaps, as well as recent and current technology maturation projects funded to help close these technology gaps. We also cover how these investments advanced their Technology Readiness Levels (TRLs) [1] and where they have been infused into missions and projects.

SAT↗

Clock Synchronization Characterization of the Washington DC Metropolitan Area Quantum Network (DC-QNet)

Quantum networking protocols relying on interference and precise time-of-flight measurements require high-precision clock synchronization. This study describes the design, implementation, and characterization of two optical time transfer methods in a metropolitan-scale quantum networking research testbed. With active electronic stabilization, sub-picosecond time deviation (TDEV) was achieved at integration times between 1 s and 10 5 s over 53 km of deployed fiber. Over the same integration periods, 10-picosecond level TDEV was observed using the White Rabbit-Precision Time Protocol (WR-PTP) over 128 km. Measurement methods are described to understand the sources of environmental fluctuations on clock synchronization towards the development of in-situ compensation methods. Path delay gradients, chromatic dispersion, polarization drift, and optical power variations all contributed to clock synchronization errors. The results from this study will inform future work in the development of link noise management methods essential for enabling experimental research in developing practical quantum networking protocols.

PIKTime↗

Picosecond Clock Synchronization Across A 7-Node Metropolitan Scale Quantum Network

Quantum networking protocols relying on interference and precise time-of-flight measurements require high precision clock synchronization. This study describes the design, implementation, and characterization of two optical time transfer methods in a metropolitan-scale quantum networking research testbed. The first technique called active electronic stabilization (ELSTAB), was able to achieve sub-picosecond time deviation (TDEV) at integration times between 1 s and 105s over multiple different fiber lengths of both underground and aerial deployed fiber. The second technique, White Rabbit-Precision Time Protocol (WR-PTP), was able to achieve 10-picosecond TDEV’s over similar fiber lengths at comparable integration times. Environmental fluctuations affected the stability of clock synchronization over deployed fiber. These fluctuations resulted in path delay gradients, chromatic dispersion, polarization drift, and optical power variations. The results from this study will inform future work in the development of compensation methods essential for enabling experimental research in developing practical quantum networking protocols.

synchronization↗