Search NASA⌕ Search

SEARCH · Search NASA

Results for “Concentrated electrolytes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Steady state composition with low Fe(2+) concentrations for efficient O2 production by 'magma' electrolysis of lunar soils

Parameters are estimated for a hypothetical, well stirred, continuous-feed electrolytic cell that converts 20 percent of a lunar soil feedstock to O2 gas, 26 percent to Fe-Si metal, 13 percent to spinel, and 41 percent to slag. Advantages of a molten Fe-Si cathode for trapping metal on reduction, a relatively conductive steady-state composition in equilibrium with spinel (a proposed container material), and close electrodes (less than 1 cm cathode-anode distance) are discussed. To produce 1 ton of O2, about 6 MHW of energy are required for the electrolysis and IR heating within the melt, and another about 6 MHW may be introduced as waste heat through internal resistance of the electrodes. Thus, to produce 1 ton of O2 per 24 hours, about 0.5 MW of power delivered to the cell would be required.

Haskin, Larry A.↗

Water Treatment Systems for Long Spaceflights

Space exploration will require new life support systems to support the crew on journeys lasting from a few days to several weeks, or longer. These systems should also be designed to reduce the mass required to keep humans alive in space. Water accounts for about 80 percent of the daily mass intake required to keep a person alive. As a result, recycling water offers a high return on investment for space life support. Water recycling can also increase mission safety by providing an emergency supply of drinking water, where another supply is exhausted or contaminated. These technologies also increase safety by providing a lightweight backup to stored supplies, and they allow astronauts to meet daily drinking water requirements by recycling the water contained in their own urine. They also convert urine into concentrated brine that is biologically stable and nonthreatening, and can be safely stored onboard. This approach eliminates the need to have a dedicated vent to dump urine overboard. These needs are met by a system that provides a contaminant treatment pouch, referred to as a urine cell or contaminant cell, that converts urine or another liquid containing contaminants into a fortified drink, engineered to meet human hydration, electrolyte, and caloric requirements, using a variant of forward osmosis (FO) to draw water from a urine container into the concentrated fortified drink as part of a recycling stage. An activated carbon pretreatment removes most organic molecules. Salinity of the initial liquid mix (urine plus other) is synergistically used to enhance the precipitation of organic molecules so that activated carbon can remove most of the organics. A functional osmotic bag is then used to remove inorganic contaminants. If a contaminant is processed for which the saline content is different than optimal for precipitating organic molecules, the saline content of the liquid should be adjusted toward the optimal value for that contaminant. A first urine treatment method converts urine into a fortified sports drink, resembling Gatorade, using a first urine cell.

FLynn, Michael T.↗

Dehydration-induced drinking in humans

The human tendency to experience a delay in rehydration (involuntary dehydration) after fluid loss is considered. The two primary factors contributing to involuntary dehydration are probably upright posture, and extracellular fluid and electrolyte loss by sweating from exercise and heat exposure. First, as the plasma sodium and osmotic concentrations remain virtually unchanged for supine to upright postural changes, the major stimuli for drinking appear to be associated with the hypovolemia and increase in the renin-angiotension system. Second, voluntary drinking during the heat experiments was 146% greater than in cool experiments; drinking increased by 109% with prior dehydration as opposed to normal hydration conditions; and drinking was increased by 41% after exercise as compared with the resting condition. Finally, it is concluded that the rate of sweating and the rate of voluntary fluid intake are highly correlated, and that the dispogenic factors of plasma volume, osmolality, and plasma renin activity are unrelated to sweat rate, but are likely to induce drinking in humans.

Greenleaf, J. E.↗

Effect of KOH concentration on LEO cycle life of IPV nickel-hydrogen flight cells-update 2

An update of validation test results confirming the breakthrough in low earth orbit (LEO) cycle life of nickel-hydrogen cells containing 26 percent KOH electrolyte is presented. A breakthrough in the LEO cycle life of individual pressure vessel (IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent potassium hydroxide (KOH) electrolyte was about 40 000 LEO cycles compared to 3500 cycles for cells containing 31 percent KOH. This test was conducted at Hughes Aircraft Company under a NASA Lewis contract. The purpose was to investigate the effect of KOH concentration on cycle life. The cycle regime was a stressful accelerated LEO, which consisted of a 27.5 min charge followed by a 17.5 min discharge (2x normal rate). The depth of discharge (DOD) was 80 percent. The cell temperature was maintained at 23 C. The boiler plate test results are in the process of being validated using flight hardware and real time LEO test at the Naval Weapons Support Center (NWSC), Crane, Indiana under a NASA Lewis Contract. Six 48 Ah Hughes recirculation design IPV nickel-hydrogen flight battery cells are being evaluated. Three of the cells contain 26 percent KOH (test cells), and three contain 31 percent KOH (control cells). They are undergoing real time LEO cycle life testing. The cycle regime is a 90-min LEO orbit consisting of a 54-min charge followed by a 36-min discharge. The depth-of-discharge is 80 percent. The cell temperature is maintained at 10 C. The three 31 percent KOH cells failed (cycles 3729, 4165, and 11355). One of the 26 percent KOH cells failed at cycle 15314. The other two 26 percent KOH cells were cycled for over 16600 cycles during the continuing test.

Smithrick, John J.↗

Multiphysics Modeling of Electrode Dissolution under Hydrodynamic Conditions in Low Conductivity Water

Efficient plug-flow electrochemical reactors are characterized by their ability to effectively convert species with significant ionic strength and/or with the assistance of a well-behaved electrolyte. Because of the classic electroconductivity requirement, electrochemical reactors are not particularly attractive options for applications with low-conductivity conditions, especially for low-pressure feeds. However, these reactors can still find application in dedicated processes such as ultra-clean water conditioning and biological-coupled separation systems. Consequently, a multi-physics model was developed using COMSOL Multiphysics to characterize different reactor-design conditions based on the Tertiary Current Distribution which accounts for the effects of expected variations in electrolyte composition and ionic strength on the electrochemical process, as well as solution resistance and electrode kinetics. The modelling framework presented here employs single-phase laminar fluid flow, the Nernst-Planck equation, the water-based electroneutrality condition, and concentration-dependent overpotentials. This investigation particularly explores the electrolysis process of “anodic dissolution,” in which elemental species dissociate from the solid matrix of the electrode and enter the liquid phase of the electrolyte as soluble ions. The reactor configuration of interest has a rectangular parallel-electrode design and is operated galvanostatically. A series of parametric studies are carried out to inspect the response of the system when hydrodynamic, kinetic, and geometric conditions are changed. The parametric sweep resulted in variable effluent concentrations and system voltage, which reveal underlaying optimization patterns for electrode dissolution in low conductivity water.

Multiphysics↗

Waste Water Brine Purification through Electrodialysis Ion Exchange

Reutilizing resources onboard the International Space Station (ISS) and for future deep space missions are critical for mission longevity and sustainability. Waste water brine produced from water recovery systems contain chemical species that could be processed into a potential fertilizer for future plant systems.Fertilizer production can be achieved through a process called electrodialysis ion exchange. Waste water containing inorganic salt components are fed through a series of ion exchange membranes to produce fertilizer (a phosphate rich stream), electrolysis-grade water, and other useful commodities.A test bed was constructed to conduct controlled experiments and an experimental design procedure developed to determine the feasibility of the process. Conductivity and pH probes were utilized to determine the ion concentration in each of the product streams, along with ion chromatography (IC) to define the exact concentration of each ion in every stream throughout the experiment. This is crucial in order to convey the effectiveness of ion removal from the incoming waste water stream.The waste water and electrolyte streams were prepared in the lab prior to experimentation. Additionally, the ion exchange membrane configurations were developed and Opto 22 data analysis software incorporated to conduct measurements in real time.Ions successfully diffused across their respective membranes into the concentrate, acid, and base streams. This resulted in pure water, a phosphate rich stream, and a separate anion/hydrogen and cation/hydroxide stream.

Hancock, Matthew L.↗

Bioassay of body fluids, experiment M005

Preflight and postflight urine and plasma samples from the Gemini 7 and Gemini 9 crewmembers were analyzed. Electrolyte and water retention observed immediately postflight was consistent with the assumption that the Gauer-Henry atrial reflex was responsive to a change from the weightless to the unit-gravity environment. Immediately postflight, plasma 17-hydroxycorticosteroid concentrations were increased and plasma uric acid concentration was decreased. The increased excretion of 17-hydroxycorticosteroids immediately postflight probably was caused by the stress of entry. The postflight increase of plasma protein, and the slightly smaller increase of plasma electrolytes postflight, was consistent with an inflight water and electrolyte loss that resulted in postflight retention of water and electrolytes.

Dietlein, L. F.↗

Thermodynamic properties of gases dissolved in electrolyte solutions.

A method based on perturbation theory for mixtures is applied to the prediction of thermodynamic properties of gases dissolved in electrolyte solutions. The theory is compared with experimental data for the dependence of the solute activity coefficient on concentration, temperature, and pressure; calculations are included for partial molal enthalpy and volume of the dissolved gas. The theory is also compared with previous theories for salt effects and found to be superior. The calculations are best for salting-out systems. The qualitative feature of salting-in is predicted by the theory, but quantitative predictions are not satisfactory for such systems; this is attributed to approximations made in evaluating the perturbation terms.

Tiepel, E. W.↗

Electrochemical Characterization of InP and GaAs Based Structures for Space Solar Cell Applications.

In this paper the emphasis is on accurate majority carrier concentration EC-V profiling of structures based on Indium Phosphide and Gallium Arsenide, using a newly developed electrolyte based on Hydrogen Flouride, Acetic Acid, Phosphoric Acid, 1-phenyl-2-propanamine and Ammonia Diflouride. Some preliminary data on the use of this electrolyte for determining the energy distribution of surface and deep states of these structures, applicable to fabrication process optimization and radiation induced defects studies of solar cells, are also provided.

Faur, Maria↗

Carbon dioxide concentrator

Passed exhaled air through electrochemical cell containing alkali metal carbonate aqueous solution, and utilizes platinized electrodes causing reaction of oxygen at cathode with water in electrolyte, producing hydroxyl ions which react with carbon dioxide to form carbonate ions.

Williams, C. F.↗

Feasibility Testing of Silver Electrolysis for Disinfection of Spacecraft Potable Water Systems

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of introducing biocidal silver into potable water on exploration spacecraft. A proof-of-concept prototype of a silver electrolysis reactor was developed, and feasibility was demonstrated for imparting a target silver concentration into a spacecraft water system. Prototype testing showed that the primary initial concerns related to the technology - inefficiencies of electrolysis in low conductivity water, the potential formation of resistive oxides on the electrode surfaces, and the potential for release of electrolytically-generated silver particles to the effluent water - were not problematic over the duration of the feasibility testing. The testing also demonstrated advantages of the technology, including the ability to consistently deliver silver at targeted concentrations and the ability to directly correlate the silver concentration to measurements of water conductivity. On the other hand, the reliability of the system has not yet been demonstrated. During prototype testing, intermittent periods of poor reactor performance manifested as a decrease in voltage accompanied by a decrease in silver output. It was determined that the cause of this behavior was silver-based deposits on inter-electrode wetted surfaces forming a conductive “bridge” between electrodes. Ongoing testing and refinement of the prototype reactor design seek to elucidate the root cause the bridging phenomenon and identify associated mitigation strategies. Once resolved, long-term performance testing is planned as part of continued development of the electrolytic silver dosing system.

Silver↗

Effect of dietary sodium on fluid/electrolyte regulation during bed rest

BACKGROUND: A negative fluid balance during bed rest (BR) is accompanied by decreased plasma volume (PV) which contributes to cardiovascular deconditioning. HYPOTHESIS: We hypothesized that increasing dietary sodium while controlling fluid intake would increase plasma osmolality (POSM), stimulate fluid conserving hormones, and reduce fluid/electrolyte (F/E) losses during BR; conversely, decreasing dietary sodium would decrease POSM, suppress fluid conserving hormones, and increase F/E losses. METHODS: We controlled fluid intake (30 ml x kg(-1) x d(-1)) in 17 men who consumed either a 4.0 +/- 0.06 g x d(-1) (174 mmol x d(-1)) (CONT; n = 6), 1.0 +/- 0.02 g x d(-1) (43 mmol x d(-1)) (LS; n = 6), or 10.0 +/- 0.04 g x d(-1) (430 mmol x d(-1)) (HS; n = 5) sodium diet before, during, and after 21 d of 6 degrees head-down BR. PV, total body water, urine volume and osmolality, POSM, and F/E controlling hormone concentrations were measured. RESULTS: In HS subjects, plasma renin activity (-92%), plasma/urinary aldosterone (-59%; -64%), and PV (-15.0%; 6.0 ml x kg(-1); p < 0.05) decreased while plasma atrial natriuretic peptide (+34%) and urine antidiuretic hormone (+24%) increased during BR (p < 0.05) compared with CONT. In LS, plasma renin activity (+166%), plasma aldosterone (+167%), plasma antidiuretic hormone (+19%), and urinary aldosterone (+335%) increased with no change in PV compared with CONT (p < 0.05). Total body water did not change in any of the subjects. CONCLUSIONS: Contrary to our hypothesis, increasing dietary sodium while controlling fluid intake during BR resulted in a greater loss of PV compared with the CONT subjects. Reducing dietary sodium while controlling fluid intake did not alter the PV response during BR compared with CONT subjects.

Clinical Trial↗

Neural mechanisms by which gravitational stimuli and stress affect the secretion of renin and other hormones

The present goal is to determine by the production of discrete lesions the parts of the hypothalamus and brainstem that are involved in serotonin-mediated increases in renin secretion. A variety of stimuli which act in different ways to increase renin stimuli were developed and standardized. The experiments with p-chloroamphetamine (PCA) demonstrated that there is a serotonergic pathway which projects from the dorsal raphe nuclei to the paraventricular nuclei and the vetromedial nuclei of the hypothalamus; that projection from paraventricular nuclei to the brainstem and spinal cord may be oxytocinergic; and that the pathway from the spinal cord to the renin secreting cells is sympathetic. The demonstration that paraventicular lesions lower circulating renin substrate is important because it raises the possibility that substrate secretion is under neural control, either via the pituitary or by direct neural pathways. The discovery that lesions of the ventromedial nuclei appear to abolish the increase in renin secretion produced by many different stimuli without affecting the concentration of renin substrate in the plasma makes the position of the hypothalamus in the regulation of fluid and electrolyte balance more prominent than previously suspected.

Ganong, William F.↗

Electrochemical characterization of p(+)n and n(+)p diffused InP structures

The relatively well documented and widely used electrolytes for characterization and processing of Si and GaAs-related materials and structures by electrochemical methods are of little or no use with InP because the electrolytes presently used either dissolve the surface preferentially at the defect areas or form residual oxides and introduce a large density of surface states. Using an electrolyte which was newly developed for anodic dissolution of InP, and was named the 'FAP' electrolyte, accurate characterization of InP related structures including nature and density of surface states, defect density, and net majority carrier concentration, all as functions of depth was performed. A step-by-step optimization of n(+)p and p(+)n InP structures made by thermal diffusion was done using the electrochemical techniques, and resulted in high performance homojunction InP structures.

Wilt, David M.↗

Effects of varying oxygen partial pressure on molten silicon-ceramic substrate interactions

The silicon sessile drop contact angle was measured on hot pressed silicon nitride, silicon nitride coated on hot pressed silicon nitride, silicon carbon coated on graphite, and on Sialon to determine the degree to which silicon wets these substances. The post-sessile drop experiment samples were sectioned and photomicrographs were taken of the silicon-substrate interface to observe the degree of surface dissolution and degradation. Of these materials, silicon did not form a true sessile drop on the SiC on graphite due to infiltration of the silicon through the SiC coating, nor on the Sialon due to the formation of a more-or-less rigid coating on the liquid silicon. The most wetting was obtained on the coated Si3N4 with a value of 42 deg. The oxygen concentrations in a silicon ribbon furnace and in a sessile drop furnace were measured using the protable thoria-yttria solid solution electrolyte oxygen sensor. Oxygen partial pressures of 10 to the minus 7 power atm and 10 to the minus 8 power atm were obtained at the two facilities. These measurements are believed to represent nonequilibrium conditions.

Ownby, D. P.↗

12-crown-4 ether-assisted enhancement of ionic conductivity and interfacial kinetics in polyethylene oxide electrolytes

The electrical and electrochemical properties of thin films of polyethylene oxide electrolytes with and without 12-crown-4 ether (12Cr4) are studied as a function of temperature and in the frequency regime from 100 kHz to 0.1 Hz. These measurements were made on electrolytes containing LiCF3SO3, LiBF4, or LiClO4 salts. At a given temperature, the bulk conductivity for a particular salt depends on the 12Cr4 concentration, reaching a maximum for a ratio of 12Cr4 to Li of 0.003.

Nagasubramanian, G.↗

In Vivo Model to Test Implanted Biosensors for Blood pH

Biosensors for monitoring physiologic data continuously through telemetry are available for heart rate, respiration, and temperature but not for blood pH or ions affected by hydrogen ion concentration. A telemetric biosensor for monitoring blood pH on-line could be used to identify and manage problems in fluid and electrolyte metabolism, cardiac and respiratory function during space flight and the acid-base status of patients without the need for venipuncture in patients on Earth. Critical to the development of biosensors is a method for evaluating their performance after implantation. Mature rats, prepared with jugular, cannulas for repeated blood samples, were exposed to a gas mixture containing high levels of carbon dioxide (7%) in a closed environment to induce mild respiratory acidosis. Serial blood gas and pH measurements in venous blood were compared with electrical responses from sensors implanted in the subcutaneous tissue. Animals became slightly tachypneic after exposure to excess CO2, but remained alert and active. After 5 minutes, basal blood pH decreased from 7.404 +/- 0.013 to 7.289 +/- 0.010 (p less than 0.001)and PC02 increased from 45 +/- 6 to 65 +/- 4 mm. Hg (p les than 0.001). Thereafter pH and blood gas parameters remained stable. Implanted sensors showed a decrease in millivolts (mV) which paralleled the change in pH and averaged 5-6 mV per 0.1 unit pH. Implanted sensors remained sensitive to modest changes in tissue pH for one week. A system for inducing acidosis in rats was developed to test the in vivo performance of pH biosensors. The system provides a method which is sensitive, rapid and reproducible in the same and different animals with full recovery, for testing the performance of sensors implanted in subcutaneous tissues.

Arnaud, Sara B.↗

Solid state potentiometric gaseous oxide sensor

A solid state electrochemical cell (10a) for measuring the concentration of a component of a gas mixture (12) includes first semiconductor electrode (14) and second semiconductor electrode (16) formed from first and second semiconductor materials, respectively. The materials are selected so as to undergo a change in resistivity upon contacting a gas component, such as CO or NO. An electrolyte (18) is provided in contact with the first and second semiconductor electrodes. A reference cell can be included in contact with the electrolyte. Preferably, a voltage response of the first semiconductor electrode is opposite in slope direction to that of the second semiconductor electrode to produce a voltage response equal to the sum of the absolute values of the control system uses measured pollutant concentrations to direct adjustment of engine combustion conditions.

Wachsman, Eric D.↗