Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contact time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A transportronic solution to the problem of interorbital transportation

An all-electronic transportation system described by the term 'transportronics' is examined as a means of solving the current problem of the high cost of transporting material from low-Earth orbit (LEO) to geostationary orbit (GEO). In this transportation system, low cost electric energy at the surface of the Earth is efficiently converted into microwave power which is then efficiently formed into a narrow beam which is kept incident upon the orbital transfer vehicles (OTV's) by electronic tracking. The incident beam is efficiently captured and converted into DC power by a device which has a very high ratio of DC power output to its mass. Because the mass of the electric thruster is also low, the resulting acceleration is unprecedented for electric-propelled vehicles. However, the performance of the system in terms of transit times from LEO to GEO is penalized by the short time of contact between the beam and the vehicle in low-Earth orbits. This makes it necessary to place the Earth based transmitters and the vehicles in the equatorial plane thus introducing many geopolitical factors. Technically, however, such a system as described in the report may out-perform any other approach to transportation in the LEO to GEO regime. The report describes and analyzes all portions of the beamed microwave power transmission system in considerable detail. An economic analysis of the operating and capital costs is made with the aid of a reference system capable of placing about 130,000 kilograms of payload into GEO each year. More mature states of the system are then examined, to a level in which 60,000 metric tons per year could be placed into GEO.

Brown, William C.↗

Generic trending and analysis system

The Generic Trending and Analysis System (GTAS) is a generic spacecraft performance monitoring tool developed by NASA Code 511 and Loral Aerosys. It is designed to facilitate quick anomaly resolution and trend analysis. Traditionally, the job of off-line analysis has been performed using hardware and software systems developed for real-time spacecraft contacts; then, the systems were supplemented with a collection of tools developed by Flight Operations Team (FOT) members. Since the number of upcoming missions is increasing, NASA can no longer afford to operate in this manner. GTAS improves control center productivity and effectiveness because it provides a generic solution across multiple missions. Thus, GTAS eliminates the need for each individual mission to develop duplicate capabilities. It also allows for more sophisticated tools to be developed because it draws resources from several projects. In addition, the GTAS software system incorporates commercial off-the-shelf tools software (COTS) packages and reuses components of other NASA-developed systems wherever possible. GTAS has incorporated lessons learned from previous missions by involving the users early in the development process. GTAS users took a proactive role in requirements analysis, design, development, and testing. Because of user involvement, several special tools were designed and are now being developed. GTAS users expressed considerable interest in facilitating data collection for long term trending and analysis. As a result, GTAS provides easy access to large volumes of processed telemetry data directly in the control center. The GTAS archival and retrieval capabilities are supported by the integration of optical disk technology and a COTS relational database management system.

Keehan, Lori↗

Time-to-Passage Judgments under Violations of Various Constancy Assumptions

Time-to-passage (TTP) derivations typically assume constant translational velocities and consistent object orientation. In our first study, we examined the impact of acceleration, and observer roll and heading (relative to track vector) on TTP judgments. Judgments reflected an insensitivity to acceleration; roll did not affect performance, but the decoupling of observer heading and track vector did. Our second study examined the effect of multi-axis target rotation on TTP and time-to-contact judgments.

Kaiser, Mary K.↗

Formal Methods for Autonomic and Swarm-based Systems

Swarms of intelligent rovers and spacecraft are being considered for a number of future NASA missions. These missions will provide MSA scientist and explorers greater flexibility and the chance to gather more science than traditional single spacecraft missions. These swarms of spacecraft are intended to operate for large periods of time without contact with the Earth. To do this, they must be highly autonomous, have autonomic properties and utilize sophisticated artificial intelligence. The Autonomous Nano Technology Swarm (ANTS) mission is an example of one of the swarm type of missions NASA is considering. This mission will explore the asteroid belt using an insect colony analogy cataloging the mass, density, morphology, and chemical composition of the asteroids, including any anomalous concentrations of specific minerals. Verifying such a system would be a huge task. This paper discusses ongoing work to develop a formal method for verifying swarm and autonomic systems.

Rouff, Christopher↗

Ditching Investigation of a 1/11-Scale Model of the Chance Vought F7U-3 Airplane, TED NO. NACA DE 360

An investigation was made of a 1/11-scale dynamically similar model of the Chance Vought F7U-3 airplane to study its behavior when ditched. The model was landed in calm water at the Langley tank no. 2 monorail. Various landing attitudes, speeds, and configurations were investigated. The behavior of the model was determined from visual observations, acceleration records, and motion-picture records of the ditchings. Data are presented in tabular form, sequence photographs, time-history acceleration curves, and plots of attitude change against time after contact. From the results of the investigation, it was concluded that the airplane should be ditched at the lowest speed and highest attitude consistent with adequate control. The aft part of the fuselage and the main landing-gear doors will probably be damaged. In a calm-water ditching under these conditions the airplane will probably skip slightly and then porpoise for the remainder of the run. Maximum longitudinal decelerations will be about 3 1/2g and maximum normal accelerations will be about 7g in a landing run of about 500 feet.

Fisher, Lloyd J.↗

The Effect of Sensory Noise Created by Compliant and Sway-Referenced Support Surfaces on Postural Stability

The purpose of the present experiment was to compare in normal human subjects the differential effects on postural stability of introducing somatosensory noise via compliant and/or sway-referenced support surfaces during quiet standing. The use of foam surfaces (two thicknesses: thin (0.95cm) and thick (7.62cm)) and sway-referenced support allowed comparison between two different types of destabilizing factors that increased ankle/foot somatosensory noise. Under some conditions neck extensions were used to increase sensory noise by deviating the vestibular system from its optimal orientation for balance control. The impact of these conditions on postural control was assessed through objective measures of instability. Thick foam and sway-referenced support conditions generated comparable instability in subjects, as measured by equilibrium score and minimum time-to-contact. However, simultaneous application of the conditions resulted in greater instability, suggesting a higher level of generated sensory noise and thus, different receptor types affected during each manipulation. Indeed, sway-referenced support generated greater anterior-posterior center-of-mass (COM) sway, while thick foam generated greater medio-lateral COM sway and velocity. Neck extension had minimal effect on postural stability until combined with simultaneous thick foam and sway-referenced support. Thin foam never generated enough sensory noise to affect postural stability even with noise added by sway-reference support or neck extension. These results provide an interesting window into the central integration of redundant sensory information and indicate the postural impact of sensory inputs is not solely based on their existence, but also their level of noise.

Forth, Katharine E.↗

Assessment of Composite Delamination Self-Healing Via Micro-Encapsulation

Composite skin/stringer flange debond specimens manufactured from composite prepreg containing interleaf layers with a polymer based healing agent encapsulated in thin walled spheres were tested. As a crack develops and grows in the base polymer, the spheres fracture releasing the healing agent. The agent reacts with catalyst and polymerizes healing the crack. In addition, through-thickness reinforcement, in the form of pultruded carbon z-pins were included near the flange tips to improve the resistance to debonding. Specimens were manufactured with 14 plies in the skin and 10 plies in the stiffener flange. Three-point bend tests were performed to measure the skin/stiffener debonding strength and the recovered strength after healing. The first three tests performed indicated no healing following unloading and reloading. Micrographs showed that delaminations could migrate to the top of the interleaf layer due to the asymmetric loading, and hence, bypass most of the embedded capsules. For two subsequent tests, specimens were clamped in reverse bending before reloading. In one case, healing was observed as evidenced by healing agent that leaked to the specimen edge forming a visible "scar". The residual strength measured upon reloading was 96% of the original strength indicating healing had occurred. Hence, self-healing is possible in fiber reinforced composite material under controlled conditions, i.e., given enough time and contact with pressure on the crack surfaces. The micro-encapsulation technique may prove more robust when capsule sizes can be produced that are small enough to be embedded in the matrix resin without the need for using an interleaf layer. However, in either configuration, the amount of healing that can occur may be limited to the volume of healing agent available relative to the crack volume that must be filled.

O'Brien, T. Kevin↗

Earthly Considerations on Mars

When it came time to contact my research subjects on the Orbiter and Lander projects, I made it clear that I wasn't interested in finger pointing and I wasn't looking to blame anyone for failures. I explained that I was studying the strategic design of each project, i. e., the grouping, linking and alignment of the project. I wanted to look at the political environment to see how the goals and interests of stakeholders affected the outcomes, and I wanted to understand the working culture of each project.

Shaw, Robert J.↗

Concept for an On-orbit Capture and Orientation Module for Potential Mars Sample Return

An orbiting sample Capture and Orient Module (COM) architecture for a Capture, Contain, and Return System (CCRS) payload concept for an Earth Return Orbiter (ERO) was developed to enable on-orbit capture, orientation, and transfer of a Mars sample container into a containment vessel for potential Mars Sample Return (MSR). The module is composed of a capture mechanism for containing the Orbiting Sample (OS), a capture cone to capture and contain the OS, an orientation mechanism to orient the OS, an External Transfer Mechanism (ETM) to cage the OS during capture and assemble it into the containment vessel, a capture trigger to trigger capture mechanism and ETM closure during OS capture, and a sensing system to inspect the OS and confirm capture and orientation. Statistical modeling and simulations of the OS during capture were performed to analyze the time to contact and perturbations to the spacecraft at first contact. A half-scale functional prototype of the module was developed to demonstrate end-to-end operation.

Younse, Paulo↗

Low resistivity contacts to YBa2Cu3O(7-x) superconductors

Silver, gold, platinum, and palladium metals were investigated as electroding materials for the YBa2Cu3O(7-x) superconductors. Painting, embedding, and melting techniques were used to apply the electrodes. Contact resistivities were determined by: (1) type of electrode; (2) firing conditions; and (3) application method. Electrodes fired for long times exhibited lower contact resistivities than those fired for short times. Low-resistivity contacts were found for silver and gold electrodes. Silver, which made good ohmic contact to the YBa2Cu3O(7-x) superconductor with low contact resistivities was found to be the best electroding material among the materials evaluated in this investigation.

Hsi, Chi-Shiung↗

Real time monitoring of COVID-19 intervention effectiveness through contact tracing data

Communities worldwide have used vaccines and facemasks to mitigate the COVID-19 pandemic. When an individual opts to vaccinate or wear a mask, they may lower their own risk of becoming infected as well as the risk that they pose to others while infected. The first benefit–reducing susceptibility–has been established across multiple studies, while the second–reducing infectivity–is less well understood. Using a new statistical method, we estimate the efficacy of vaccines and facemasks at reducing both types of risks from contact tracing data collected in an urban setting. We find that vaccination reduced the risk of onward transmission by 40.7% [95% CI 25.8–53.2%] during the Delta wave and 31.0% [95% CI 19.4–40.9%] during the Omicron wave and that mask wearing reduced the risk of infection by 64.2% [95% CI 5.8–77.3%] during the Omicron wave. By harnessing commonly-collected contact tracing data, the approach can broadly provide timely and actionable estimates of intervention efficacy against a rapidly evolving pathogen.

60 APPLIED LIFE SCIENCES↗

Vapor detection and vapor pressure measurements of fentanyl and fentanyl hydrochloride salt at ambient temperatures

There is a need for non-contact, real-time vapor detection of drugs to combat illicit transportation and help curb the opioid epidemic. The low-volatility of drugs, like fentanyl, makes room temperature vapor detection of illicit drugs challenging, but feasible by atmospheric flow tube-mass spectrometry (AFT-MS). AFT-MS is a non-contact vapor detection approach capable of ultra-trace detection of drugs, including fentanyl and its analogs at low parts-per-quadrillion (ppqv) levels. The determination of vapor pressure values of fentanyl is necessary to understand potential vapor concentrations that may be available for detection. In this paper, vapor pressures of fentanyl free base and fentanyl hydrochloride salt (a common form of the illicit drug) were measured as a function of temperature at or near ambient conditions using the transpiration (gas saturation) method and AFT-MS. Based on our measurements, the vapor pressure of fentanyl at 25 °C is 9.0 × 10-14 atm (90 ppqv), and the vapor pressure of fentanyl hydrochloride at 25 °C is 1.8 x 10-17 atm (0.018 ppqv). We also demonstrate non-contact, real-time vapor detection of fentanyl. Preconcentration of vapors can further extend the detection capabilities. The collection, desorption, and detection of fentanyl vapors at ambient conditions was demonstrated for sampling times of seconds to an hour resulting in increased signal. AFT-MS is a viable detection method of fentanyl and other drugs for screening of packages and cargo.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗

Shock and contact interaction with a simple cubic array of particles

Shock-particle interaction is a fundamental pillar of multiphase compressible flows that has been studied at length for many decades. However, little attention has been paid to the interaction of particles with a contact interface that follows a shock in shock tube experiments and applications relating to blast waves. Presently, the phenomenon is studied at the microscale via particle resolved simulations of shock contact systems interacting with a structured array of particles as well as isolated particles. Simulations are conducted at particle volume fractions of 0%, 5%, 10%, 20%, and 40% at three contact Mach numbers. Additionally, the diaphragm position is varied, which controls the timing of the shock arrival time in relation to the contact arrival time. The modification to the drag on these stationary particles by the contact is analyzed and compared to the compressible Maxey–Riley–Gatignol model, which is adequate for the single particle cases but does not account for fluid mediated particle–particle interactions.

Mechanics↗

Non-Contact Vapor Detection of Illicit Drugs via Atmospheric Flow Tube-Mass Spectrometry

Real-time, non-contact detection of illicit drugs is a desirable goal for the interdiction of these controlled substances, but the relatively low vapor pressures of such species present a challenge for trace vapor detection technologies. The introduction of atmospheric flow tube-mass spectrometry (AFT-MS), which has previously been demonstrated to detect gas-phase analytes at low parts-per-quadrillion levels for explosives and organophosphorus compounds, also enables the potential for non-contact drug detection. With AFT-MS, direct vapor detection of cocaine and methamphetamine from ~5 µg residues at room temperature is demonstrated herein. Furthermore, thermal desorption of low- to sub-picogram levels of cocaine, methamphetamine, fentanyl, and heroin is observed via AFT-MS using a carrier flow rate of several L/min of air. These low levels can permit non-contact sampling through collection of vapor, effectively preconcentrating the analyte before desorption and analysis. Quantitative evaluation of the thermal desorption approach has yielded limits of detection (LODs) on order of 10 fg for cocaine and fentanyl, 100 fg for methamphetamine, and 1.6 pg for heroin. The LOD for heroin was lowered to 200 fg by using tributyl phosphate as a dopant to form a proton-bound heterodimer with heroin. When used with AFT-MS, the intentional formation of specific drug-dopant adducts has the potential to enhance detection limits and selectivity of additional drug species. Species that are prone to form adducts present a challenge to analysis, but that difficulty can be overcome by the intentional addition of a dopant. Molecules unlikely to form adducts will remain essentially unimpacted, but the adduct-forming species will interact with the dopant to compress the analyte signal into a single peak. This approach would be valuable in the application of non-contact screening for illicit substances via vapor collection followed by thermal desorption for analysis.

methamphetamine, cocaine, heroin, fentanyl, atmosp↗

Method and Apparatus for Monitoring of Daily Activity in Terms of Ground Reaction Forces

A device to record and analyze habitual daily activity in terms of the history of gait-related musculoskeletal loading is disclosed. The device consists of a pressure-sensing insole placed into the shoe or embedded in a shoe sole, which detects contact of the foot with the ground. The sensor is coupled to a portable battery-powered digital data logger clipped to the shoe or worn around the ankle or waist. During the course of normal daily activity, the system maintains a record of time-of-occurrence of all non-spurious foot-down and lift-off events. Off line, these data are filtered and converted to a history of foot-ground contact times, from which measures of cumulative musculoskeletal loading, average walking- and running-specific gait speed, total time spent walking and running, total number of walking steps and running steps, and total gait-related energy expenditure are estimated from empirical regressions of various gait parameters to the contact time reciprocal. Data are available as cumulative values or as daily averages by menu selection. The data provided by this device are useful for assessment of musculoskeletal and cardiovascular health and risk factors associated with habitual patterns of daily activity.

Whalen, Robert T.↗

Sudden-Discharge Cycling Characteristics and Millisecond Dynamic Behaviors of a HTS Stainless-Steel Insulated Double-Pancake Coil With Thin Copper Plates

We have tested an intermediate-sized HTS stainless-steel (co-wound) insulated double pancake coil (~132 turns per coil) and discovered dynamic effects during sudden discharge on both millisecond and second scales. For soft break, the power supply is turned off suddenly but the shunt resistor (164 milliohm) is still connected; for hard break, a high voltage contactor is used to suddenly open the circuit so that the leads are completely open. Hard break is dangerous to traditionally insulated LTS magnets, but the SS-insulated HTS DPC retained integrity over ¡80 charge-discharge cycles. Voltage decay curves for soft and hard breaks are studied on short and long timescales. On long timescales, we observe the expected exponential decay and measure the time constant to calculate contact resistance. On short timescales, we observe highly dynamic effects: a hyper-exponential decay suggesting that the inductance or contact resistance is suddenly changing with time, likely an indication of the RL circuit forming. Moreover, peak voltage immediately (ms) after the sudden discharge were collected and compared. It is found that the peak voltage in soft-discharge is proportional to the applied current, while the those in hard-break has a unique pattern and tends to stay flat even though the applied current increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implications of privacy needs and interpersonal distancing mechanisms for space station design

Isolation, confinement, and the characteristics of microgravity will accentuate the need for privacy in the proposed NASA space station, yet limit the mechanism available for achieving it. This study proposes a quantitative model for understanding privacy, interpersonal distancing, and performance, and discusses the practical implications for Space Station design. A review of the relevant literature provided the basis for a database, definitions of physical and psychological distancing, loneliness, and crowding, and a quantitative model of situational privacy. The model defines situational privacy (the match between environment and task), and focuses on interpersonal contact along visual, auditory, olfactory, and tactile dimensions. It involves summing across pairs of crew members, contact dimensions, and time, yet also permits separate analyses of subsets of crew members and contact dimensions. The study concludes that performance will benefit when the type and level of contact afforded by the environment align with that required by the task. The key to achieving this is to design a flexible, definable, and redefinable interior environment that provides occupants with a wide array of options to meet their needs for solitude, limited social interaction, and open group activity. The report presents 49 recommendations in five categories to promote a wide range of privacy options despite the space station's volumetric limitations.

Harrison, Albert A.↗

Surface settling in partially filled containers upon step reduction in gravity

A large literature exists concerning the equilibrium configurations of free liquid/gas surfaces in reduced gravity environments. Such conditions generally yield surfaces of constant curvature meeting the container wall at a particular (contact) angle. The time required to reach and stabilize about this configuration is less studied for the case of sudden changes in gravity level, e.g. from normal- to low-gravity, as can occur in many drop tower experiments. The particular interest here was to determine the total reorientation time for such surfaces in cylinders (mainly), as a function primarily of contact angle and kinematic viscosity, in order to aid in the development of drop tower experiment design. A large parametric range of tests were performed and, based on an accompanying scale analysis, the complete data set was correlated. The results of other investigations are included for comparison.

Weislogel, Marl M.↗