Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminated data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Multiple single event upsets in CMOS static rams

The occurrence of multiple upset errors during ground tests can contaminate the data and lead to error cross sections which are too high. In space, multiple errors may produce higher upsets than predicted and if they occur in single words they can defeat error detection and correction hardware. This investigation involves data which were taken during an experimental study of dose imprint effects in static memories. The results show that multiple errors occurred mainly for heavy ions with high linear energy transfers and with the majority of these in the soft upset sections of the dose-imprinted memory samples. The percentages of the total number of errors which were singles, doubles, and triplets, were determined as a function of LET, dose, and soft or hard section of the devices. The experimental observations are compared to the predictions of simple binomial statistics.

Stassinopoulos, E. G.↗

SeaWiFS technical report series. Volume 28: SeaWiFS algorithms, part 1

This document provides five brief reports that address several algorithm investigations sponsored by the Calibration and Validation Team (CVT) within the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project. This volume, therefore, has been designated as the first in a series of algorithm volumes. Chapter 1 describes the initial suite of masks, used to prevent further processing of contaminated radiometric data, and flags, which are employed to mark data whose quality (due to a variety of factors) may be suspect. In addition to providing the mask and flag algorithms, this chapter also describes the initial strategy for their implementation. Chapter 2 evaluates various strategies for the detection of clouds and ice in high latitude (polar and sub-polar regions) using Coastal Zone Color Scanner (CZCS) data. Chapter 3 presents an algorithm designed for detecting and masking coccolithosphore blooms in the open ocean. Chapter 4 outlines a proposed scheme for correcting the out-of-band response when SeaWiFS is in orbit. Chapter 5 gives a detailed description of the algorithm designed to apply sensor calibration data during the processing of level-1b data.

Hooker, Stanford B.↗

Clump Giants in the Hyades

The project is entitled 'Clump Giants in the Hyades.' This observation of one of the late-type Hyades giants (Gamma Tau) has implications for understanding the formation of late-type stellar coronae as a function of the evolutionary state of the star. The Hyades giants are interesting because they are all clump giants in the Helium burning phase, similar to the cool primary of Capella. The Hyades giants show significantly more magnetic activity than expected from their state of evolution (and slowed-down rotation). Thus these systems provide an important clue to dynamo action. The data were obtained by the satellite on 13 March 2001 for a total RGS exposure of 58220 seconds. These data were delivered to the PI on 7 August 2001. The data could not be reprocessed until SAS Version 5.3.3 which became available 7 June 2002. Although the guidelines for assessing background rates suggested that half the data were contaminated, it does not appear that the spectral region of the RGS was adversely affected by unusually high background. The spectra show strong lines of Fe XVII and XVIII, O VII and VIII, Ne IX and X, along with numerous weaker lines. The emission measure distribution is highly reminiscent of Capella; if anything, the emission measure distribution is steeper at 6 million K than for Capella. Gamma Tau is the second brightest of the Hyades clump giants. Pallavicini et al. have shown that the luminosity of the brightest Hyades giant (Theta Tau) is remarkably similar to its luminosity as measured by Einstein. Short-term variability is also modest. We are addressing the variability issue now for Gamma Tau. Initial results were reported at the 2003 Seattle AAS meeting. A paper is in preparation for submission to the Astrophysical Journal.

Mushotzky, Richard F.↗

Changes in the X-Ray Emission from the Magnetar Candidate 1E 2259+586 During its 2002 Outburst

An outburst of more than 80 individual bursts, similar to those seen from Soft Gamma Repeaters (SGRs), was detected from the anomalous X-ray pulsar (AXP) 1E 2259+586 in 2002 June. Coincident with this burst activity were gross changes in the pulsed flux, persistent flux, energy spectrum, pulse profile, and spin-down of the underlying X-ray source. We present Rossi X-Ray Timing Explorer and X-Ray Multi-Mirror Mission observations of 1E 2259+586 that show the evolution of the aforementioned source parameters during and following this episode and identify recovery timescales for each. Specifically, we observe an X-ray flux increase (pulsed and phase-averaged) by more than an order of magnitude having two distinct components. The first component is linked to the burst activity and decays within approx. 2 days, during which the energy spectrum is considerably harder than during the quiescent state of the source. The second component decays over the year following the glitch according to a power law in time with an exponent -0.22 +/- 0.01. The pulsed fraction decreased initially to approx. 15% rms but recovered rapidly to the preoutburst level of approx. 23% within the first 3 days. The pulse profile changed significantly during the outburst and recovered almost fully within 2 months of the outburst. A glitch of size Delta(sib (nu)max) = (4.24 +/- 0.11) x 10(exp -6) was observed in 1E 2259+586, which preceded the observed burst activity. The glitch could not be well fitted with a simple partial exponential recovery. An exponential rise of approx. 20% of the frequency jump with a timescale of approx. 14 days results in a significantly better fit to the data; however, contamination from a systematic drift in the phase of the pulse profile cannot be excluded. A fraction of the glitch (approx. 19%) was recovered in a quasi-exponential manner having a recovery timescale of approx. 16 days. The long-term postglitch spin-down rate decreased in magnitude relative to the preglitch value. The changes in the source properties of 1E 2259+586 during its 2002 outburst are shown to be qualitatively similar to changes seen during or following burst activity in two SGRs, thus further solidifying the common nature of SGRs and AXP's as magnetars. The changes in persistent emission properties of 1E 2259+586 suggest that the star underwent a plastic deformation of the crust that simultaneously impacted the superfluid interior (crustal and possibly core superfluid) and the magnetosphere. Finally, the changes in persistent emission properties coincident with burst activity in 1E 2259+586 enabled us to infer previous burst-active episodes from this and other AXP's. The nondetection of these outbursts by all-sky gamma-ray instruments suggests that the number of active magnetar candidates in our Galaxy is larger than previously thought.

Woods, P. M.↗

NREPS Applications for Water Supply and Management in California and Tennessee

Management of water resources is a balancing act between temporally and spatially limited sources and competitive needs which can often exceed the supply. In order to manage water resources over a region such as the San Joaquin Valley or the Tennessee River Valley, it is pertinent to know the amount of water that has fallen in the watershed and where the water is going within it. Since rain gauge networks are typically sparsely spaced, it is typical that the majority of rainfall on the region may not be measured. To mitigate this under-sampling of rainfall, weather radar has long been employed to provide areal rainfall estimates. The Next-Generation Weather Radars (NEXRAD) make it possible to estimate rainfall over the majority of the conterminous United States. The NEXRAD Rainfall Estimation Processing System (NREPS) was developed specifically for the purpose of using weather radar to estimate rainfall for water resources management. The NREPS is tailored to meet customer needs on spatial and temporal scales relevant to the hydrologic or land-surface models of the end-user. It utilizes several techniques to mitigate artifacts in the NEXRAD data from contaminating the rainfall field. These techniques include clutter filtering, correction for occultation by topography as well as accounting for the vertical profile of reflectivity. This presentation will focus on improvements made to the NREPS system to map rainfall in the San Joaquin Valley for NASA s Water Supply and Management Project in California, but also ongoing rainfall mapping work in the Tennessee River watershed for the Tennessee Valley Authority and possible future applications in other areas of the continent.

Gatlin, P.↗

Background Noise Reduction Using Adaptive Noise Cancellation Determined by the Cross-Correlation

Background noise due to flow in wind tunnels contaminates desired data by decreasing the Signal-to-Noise Ratio. The use of Adaptive Noise Cancellation to remove background noise at measurement microphones is compromised when the reference sensor measures both background and desired noise. The technique proposed modifies the classical processing configuration based on the cross-correlation between the reference and primary microphone. Background noise attenuation is achieved using a cross-correlation sample width that encompasses only the background noise and a matched delay for the adaptive processing. A present limitation of the method is that a minimum time delay between the background noise and desired signal must exist in order for the correlated parts of the desired signal to be separated from the background noise in the crosscorrelation. A simulation yields primary signal recovery which can be predicted from the coherence of the background noise between the channels. Results are compared with two existing methods.

Spalt, Taylor B.↗

Components Refurbishment and Chemical Analysis Facility Hot Spot 1 Year 2 Annual Performance Monitoring Report

The Performance Monitoring Report presents the Year 2 operations, maintenance, and monitoring (OM&M) activities for the hydraulic containment system (HCS) Interim Measures (IM) at the Components Refurbishment and Chemical Analysis (CRCA) Facility located at John F. Kennedy Space Center (KSC), Florida. Year 2 operations extended from September 2020 to August 2021 and included: operation, maintenance and monitoring of the HCS; performance monitoring through collection of groundwater samples; and sub-slab gas and ambient air sampling. The existing hydrogeologic model was also updated. The system is performing as designed, and groundwater data demonstrate contaminant reduction.

CRCA↗

Overview of the International Space Station’s Water and Cabin Air Quality: A Five-Year Status

Since the beginning of the International Space Station (ISS), water and air quality have been monitored to ensure crew health and verify the performance of the regenerative Environmental Control and Life Support (ECLS) systems. Over the last 25 years, the ISS has evolved greatly with significant changes to operations, crew complement sizes, visiting vehicles, payloads, and upgrades within the regenerative hardware, seen through Technology Demonstration integrations. In particular, better assessment and prevention of volatile organic releases from payloads and crew hygiene products, and implementation of advanced sorbents both on the air and water strings have been successful in reducing contaminant loads. Data on air and water quality for the last five years on ISS will be presented (nominal and contingency air grab samples, in-flight monitoring for air and water quality, and water samples from all segments of the ISS water system), including some notable events. The available data demonstrate the performance of existing ECLS systems and overall status of how the approach to air and water quality have evolved through the new ISS architecture baseline operations.

air quality↗

ABSTRACT: Design of Groundwater Monitoring Networks Considering Conceptual Model and Parametric Uncertainty

Uncertainty built into conceptual groundwater flow and transport models and associated parametric uncertainty should be appropriately included when such models are used to develop detection monitoring networks for contaminated sites. We compare alternative approaches of propagating such uncertainty from the flow and transport model into the network design. The focus is on detection monitoring networks where the primary objective is to intercept the contaminant before it reaches a boundary of interest (e.g., compliance boundary). Different uncertainty propagation approaches identify different well locations and different well combinations (networks) as having the highest detection efficiency. It is thus recommended that multiple uncertainty propagation approaches are considered. If several approaches yield consistent results in terms of identifying the best performing candidate wells and the best performing well network for detecting a contaminant plume, this would provide confidence in the suitability of the selected well locations.

54 ENVIRONMENTAL SCIENCES↗

Uranium Contamination in the 300 Area: Emergent Data and their Impact on the Source Term Conceptual Model

The primary objectives of this characterization activity were to: 1) determine the extent of uranium contamination in the sediments, 2) quantify the leachable (labile) concentration of uranium in the sediments, and 3) create a data set that could be used to correlate the present data to existing 300 Area data. In order to meet these objectives, sediments collected from wells 399-2-5 (C5708), 299-3-22 (C5706) and 299-4-14 (C5707) were analyzed for moisture content, 1:1 sediment:water extracts (which provide soil pH, electrical conductivity [EC], cation, and anion data), total carbon and inorganic carbon content, 8 M nitric acid extracts (which provide a measure of the total leachable sediment content of the contaminants), microwave-assisted digestion (which results in total digestion of the sediment), and carbonate leaches (which provide an assessment of the concentration of labile uranium present in the sediments). Additionally, pore waters present in select samples were extracted using ultracentrifugation. The mobility characteristics of uranium vary within the multiple subsurface zones that contain residual contaminant uranium. Principal subsurface zones include 1) the vadose zone, 2) a zone through which the water table rises and falls, 3) the aquifer, and 4) a zone where groundwater and river water interact beneath the river shoreline. Principal controls on mobilization include the form of the residual uranium (e.g., crystalline minerals, amorphous precipitates/coatings, sorbed onto sediment), the transporting medium (e.g., water infiltration from the land surface, groundwater), and the rate of exchange between the form and transporting medium. The bicarbonate content of aqueous media strongly influences the rate of exchange, with relatively higher content enhancing mobility. Groundwater has a higher bicarbonate content than river water or other freshwater sources, such as utility and potable water systems. The variety of processes affecting the mobility of uranium in the subsurface, along with the numerous potential compartments where residual contamination may be located, presents challenges for predicting uranium movement through environmental pathways. The processes responsible for the persistence of the plume may involve cycling of uranium between the aquifer and overlying zone through which the water table fluctuates. Contaminated groundwater is moved upward into the lower vadose zone, and when the water table subsequently falls, contaminated moisture is left behind. Some of the uranium in groundwater may become sorbed to sediment in that zone, to subsequently slowly release. Also, near the Columbia River in the zone of groundwater/river water interaction, where the bicarbonate content is lowered because of infiltrating river water, the tendency for uranium to adsorb onto sediment is enhanced, thus slowing dissipation via the groundwater pathway. Fluctuations in the Columbia River stage are the driving mechanism for the rise and fall of the water table beneath the 300 Area, and also for creating the dynamic hydraulic and geochemical environment found in the zone of interaction beneath the shoreline.

300 Area↗

Modeling correlation with flight data

The molecular contamination flow model (space 2 program) predicts the induced environment of the space shuttle orbiter/payload on orbit as well as the induced gas flow between the orbiter and payload surfaces. This computer program relates the input parameters which characterize the time dependent status of the orbiter/payload to the required output parameters. An application of the model to data from space transportation system flights 1, 2, and 3 shows that the model correlates well for direct flow and for return flux (STS-2/H2O). Correlation for return flux from other molecular sources/species appears to be within expectations but more analysis is required. The space 2 model seems to be an adequate predictive tool.

Ehlers, H. K. F.↗

Unclassified Source Term and Radionuclide Data for the Groundwater Flow and Contaminant Transport Model for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada, Revision 1

This report documents the evaluation of information and data available on the unclassified source term and radionuclide (RN) contamination for Central and Western Pahute Mesa (PM): Corrective Action Units (CAUs) 101 and 102. The Central and Western PM CAUs constitute two areas of the Nevada National Security Site (NNSS) used for underground nuclear testing (Figure 1-1). Eighty-five underground nuclear tests were conducted at the PM CAUs between 1965 and 1992 (NNSA/NFO, 2015b). Underground nuclear tests deposit radioactive elements in the subsurface, resulting in groundwater contamination in the vicinity of the underground test locations. At the PM CAUs, the testing resulted in more than 2.68 × 10 7 curies (Ci) of radioactivity (decay-corrected to September 30, 2012) remaining underground (Finnegan et al., 2016). Of the 85 underground nuclear tests conducted at the PM CAUs, three were shallow tests detonated within 200 meters (m) of the surface and referred to as the “near-surface tests”; the remaining 82 were detonated deeper than 200 m below ground surface (bgs) and are referred to as the “deep underground tests” in this document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ozone contamination in aircraft cabins: Results from GASP data and analyses

The global atmospheric sampling program pertaining to the problem of ozone contamination in commercial airplane cabins is described. Specifically, analyses of GASP data have: confirmed the occurrence of high ozone levels in aircraft cabins and documented the ratio of ozone inside and outside the cabins of two B747 airliners, including the effects of air conditioning modifications on that ratio; defined ambient ozone climatology at commercial airplane cruise altitudes, including tabulation of encounter frequency data which were not available before GASP; and outlined procedures for estimating the frequency of flights encountering high cabin ozone levels using climatological ambient ozone data, and verified these procedures against cabin measurements.

Holdeman, J. D.↗

Three Years of Multilevel Monitoring Data at the Riverton, Wyoming, Processing Site That Show Contaminant Increases After River Flooding Events and a Large Recharge Event

The tailings pile at the Riverton, Wyoming, Processing Site has been removed, but contaminant concentrations in the shallow aquifer increase after large recharge events. The Riverton site experienced flooding near the Little Wind River in early May 2016, February 2017, and June 2017. The May 2016 flooding was from a large rain event. The February 2017 flooding was due to an ice jam, and the June 2017 flooding was due to mountain snowmelt runoff. In addition, the site experienced high water tables in April and May 2017, as this was the second wettest spring in Riverton since records began in 1918. Past reports indicated the accumulation of solid-phase uranium and molybdenum in evaporites above the respective contaminant groundwater plumes. Given these data, multilevel monitoring wells were installed in 2015 to monitor seasonal changes in groundwater quality. Data from three years of groundwater monitoring are summarized in this report and compared with the flooding and large recharge events. The results indicate that evaporite-related constituents (especially sodium, sulfate, and chloride) present across the site in a silt layer can be released to the shallow sand and gravel aquifer during flooding and large recharge events. The solid-phase and water-phase data confirm that these evaporites are mainly sodium sulfate and sodium chloride salts with some calcite and gypsum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiscal Year 2010 Phased Construction Completion Report for EU Z2-32 in Zone 2, East Tennessee Technology Park, Oak Ridge, Tennessee

The Record of Decision for Soil, Buried Waste, and Subsurface Structure Actions in Zone 2, East Tennessee Technology Park, Oak Ridge, Tennessee (DOEIORJO 1-2161 &D2) (Zone 2 ROD) acknowledged that most of the 800 acres in Zone 2 were contaminated, but that sufficient data to confirm the levels of contamination were lacking. The Zone 2 ROD further specified that a sampling strategy for filling the data gaps would be developed. The Remedial Design Report/Remedial Action Work Plan for Zone 2 Soils, Slabs, and Subsurface Structures, East Tennessee Technology Park, Oak Ridge, Tennessee (DOEIORIO 1 -2224&D3) (RDRJRAWP) defined the sampling strategy as the Dynamic Verification Strategy (DVS), generally following the approach used for characterization of the Zone I exposure units (EUs). The Zone 2 ROD divided the Zone 2 area into seven geographic areas and 44 EUs. To facilitate the data quality objectives (DQOs) of the DVS process, the RDR/RAWP regrouped the 44 EUs into 12 DQO scoping EU groups. These groups facilitated the DQO process by placing similar facilities and their support facilities together, which allowed identification of data gaps. The EU groups were no longer pertinent after DQO planning was completed and characterization was conducted as areas became accessible. As the opportunity to complete characterization became available, the planned DVS program was completed for the EU addressed in this document (EU Z2-32). The purpose of this Phased Construction Completion Report (PCCR) is to address the following: (1) Document DVS characterization results for EU Z2-32. (2) Describe and document the risk evaluation and determine if the EU meets the Zone 2 ROD requirements for unrestricted industrial use to 10 ft bgs. (3) Identify additional areas not defined in the Zone 2 ROD that require remediation based on the DVS evaluation results. (4) Describe the remedial action performed in the K-1066-G Yard in EU Z2-32. Approximately 18.4 acres are included in the EU addressed in this PCCR. Based on results of the DVS evaluation, all 18.4 acres are recommended for unrestricted industrial use to 10 ft bgs. There are no Federal Facility Agreement Sites included in Appendix A of the Zone 2 ROD in EU Z2-32. The Zone 2 ROD requires land use controls to prevent disturbance of soils below 10 ft deep and to restrict future land use to industrial/commercial activities. In response to stakeholder comments, the U.S. Department of Energy agreed to re-evaluate the need for such land use restrictions. This document includes a screening evaluation to determine the likelihood of land use controls in EU Z2-32 being modified to: (1) eliminate the restriction on disturbance of soils below 10 ft bgs where data indicate the absence of residual contamination at any depth that would result in an unacceptable risk to the future industrial worker, and (2) permit alternative land uses that would be protective of future site occupants. Results of this screening evaluation indicate a high probability that restrictions on disturbing soil below 10 ft bgs could be safely eliminated for EU Z2-32. A qualitative screening evaluation considered the likelihood of unrestricted land use being protective of future site occupants. Based on this qualitative assessment, all 18.4 acres addressed in this PCCR were assigned a high probability for consideration of release for unrestricted land use. This document contains the main text (Sects. 1 through 13) and one appendix. The main text addresses the purpose for this PCCR as described above. Additional supporting detail (e.g., field work and data summaries, graphics) is provided in the EU Z2-32 technical memorandum (Appendix A). Historical and DVS analytical data used in this PCCR are provided on a compact disc accompanying this document and can be accessed through the Oak Ridge Environmental Information System.

54 ENVIRONMENTAL SCIENCES↗

Fiscal Year 2008 Phased Construction Completion Report for EU Z2-33 in Zone 2, East Tennessee Technology Park, Oak Ridge, Tennessee

The Record of Decision for Soil, Buried Waste, and Subsurface Structure Actions in Zone 2, East Tennessee Technology Park, Oak Ridge, Tennessee (DOE/OR/01-2161&D2) (Zone 2 ROD) acknowledged that most of the 800 acres in Zone 2 were contaminated, but that sufficient data to confirm the levels of contamination were lacking. The Zone 2 ROD further specified that a sampling strategy for filling the data gaps would be developed. The Remedial Design Report/Remedial Action Work Plan for Zone 2 Soils, Slabs, and Subsurface Structures, East Tennessee Technology Park, Oak Ridge, Tennessee (DOE/OR/01-2224&D3) (Zone 2 RDR/RAWP) defined the sampling strategy as the Dynamic Verification Strategy (DVS), generally following the approach used for characterization of the Zone 1 exposure units (EUs). The Zone 2 ROD divided the Zone 2 area into seven geographic areas and 44 EUs. To facilitate the data quality objectives (DQOs) of the DVS process, the Zone 2 RDR/RAWP regrouped the 44 EUs into 12 DQO scoping EU groups. These groups facilitated the DQO process by placing similar facilities and their support facilities together and allowing identification of data gaps. The EU groups were no longer pertinent after DQO planning was completed and characterization was conducted as areas became accessible. As the opportunity to complete characterization became available, the planned DVS program and remedial actions (RAs) were completed for EU Z2-33. Remedial action was also performed at two additional areas in adjacent EU Z2-42 because of their close proximity and similar nature to a small surface soil RA in EU Z2-33. Remedial actions for building slabs performed in EU Z2-33 during fiscal year (FY) 2007 were reported in the Fiscal Year 2007 Phased Construction Completion Report for the Zone 2 Soils, Slabs, and Subsurface Structures at East Tennessee Technology Park, Oak Ridge, Tennessee (DOE/OR/01-2723&D1). Recommended RAs for EU Z2-42 were described in the Fiscal Year 2006 Phased Construction Completion Report for the Zone 2 Soils, Slabs, and Subsurface Structures at East Tennessee Technology Park, Oak Ridge, Tennessee (DOE/OR/01-2317&D2). Remedial actions performed in the Balance of Site (BOS) Laboratory Area of EU Z2-33 and two small areas in EU Z2-42 are described in Sects. 5 through 10 of this Phased Construction Completion Report (PCCR). The purpose of this PCCR is to address the following: (1) Document DVS characterization results for EU Z2-33; (2) Describe and document the risk evaluation and determine if the EU meets the Zone 2 ROD requirements for unrestricted industrial use to 10 ft bgs; (3) Identify additional areas not defined in the Zone 2 ROD that require remediation based on the DVS evaluation results; and (4) Describe RAs performed in the EU Z2-33 BOS Laboratory Area and two small areas in EU Z2-42. Approximately 18 acres in EU Z2-33 are addressed in this PCCR. Based on the results of the DVS evaluation and RAs performed, all 18 acres are recommended for unrestricted industrial use to 10 ft bgs. Three Federal Facility Agreement sites are addressed and recommended for no further action within this acreage, including: (1) K-1004-L Recirculating Cooling Water Lines Leak Sites; (2) K-1044 Heavy Equipment Repair Shop; and (3) K-1015-A Laundry Pit. Remedial actions for EU Z2-33 were developed in response to DVS characterization results described in the EU Z2-33 Technical Memorandum (Appendix A) and to support reindustrialization of the East Tennessee Technology Park as a commercial industrial park. Remediation criteria were designed for the protection of a future industrial worker who normally would not have the potential for exposure to soil below 10ft bgs. Accordingly, the Zone 2 ROD required land use controls to prevent disturbance of soils below 10 ft deep and to restrict future land use to industrial/commercial activities. In response to stakeholder comments, the U.S. Department of Energy agreed to re-evaluate the need for such land use restrictions. This document includes a screening evaluation to determine the likelihood of land use controls in EU Z2-33 being modified to: (1) eliminate the restriction on disturbance of soils below 10 ft bgs where data indicate the absence of residual contamination at any depth that would result in an unacceptable risk to the future industrial worker, and (2) permit alternative land uses that would be protective of future site occupants. Results of this screening evaluation indicate a low probability that restrictions on disturbing soil below 10 ft bgs could be safely eliminated for EU Z2-33. A qualitative screening evaluation considered the likelihood of unrestricted land use being protective of future site occupants. Based on this qualitative assessment, all 18 acres addressed in this PCCR were assigned a low probability for consideration of release for unrestricted land use.

54 ENVIRONMENTAL SCIENCES↗