Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Point to Point Control of the Hydrogen Mixer

We continue to build on the theoretical modelling of a liquid hydrogen (LH2) and gas hydrogen (GH2) mixer subsystem. The mixer described in this work is responsible for combining high pressure LH2 and GH2 to produce a hydrogen flow that meets certain thermodynamic properties. The desired properties are maintained by precise control of the LH2 and GH2 flows. The mixer is modelled as a general multi-flow lumped volume for single constituent fluids using density and internal energy as states. The set of nonlinear differential equations is modelled in the SIMULINK environment including a table look-up feature of the fluid thermodynamic properties. A small signal (linear) model is developed based on the nonlinear model and simulated as well. Pulse disturbances are introduced to the valve positions and the quality of the linear model is ascertained by comparing its behavior against the nonlinear model simulations. Valve control strategies that simulate an operator-in-the-loop scenario are then explored demonstrating the need for automatic feedback control. Finally, optimal single-output and multi-output Proportional/Integral controllers are designed based on the linear model and applied to the nonlinear model with excellent results to track simultaneous, constant setpoint changes in desired exit flow, exit temperature, and mixer pressure, as well as to reject unmeasureable but bounded additive step perturbations in the valve positions.

Barbieri, Enrique↗

Pointing Control System Design and Performance Evaluation for TPF Coronagraph

The Terrestrial Planet Finder (TPF) program aims to detect and characterize extra-solar Earth-like planets. The coronagraph telescope is one of the four mission concepts being studied. In order to reject the star flux and detect the planet flux in the visible light range, the coronagraph telescope must achieve a rejection ratio on the order of a billion to one. Dynamic jitter, introduced by environmental and on-board mechanical disturbances, degrades the optical performance, as characterized primarily by contrast ratio. The feasibility of using passive vibration isolation combined with active attitude and line-of- sight control systems to stabilize the spacecraft and the optical components to the requisite level is being studied. The telescope is also required to slew between targets. The slew mode control law must be designed to balance the need for efficient large-angle maneuvers while simultaneously avoiding the excitation of flexible modes in order to minimize settling time.

Liu, Kuo-Chia↗

Angle-of-Attack-Modulated Terminal Point Control for Neptune Aerocapture

An aerocapture guidance algorithm based on a calculus of variations approach is developed, using angle of attack as the primary control variable. Bank angle is used as a secondary control to alleviate angle of attack extremes and to control inclination. The guidance equations are derived in detail. The controller has very small onboard computational requirements and is robust to atmospheric and aerodynamic dispersions. The algorithm is applied to aerocapture at Neptune. Three versions of the controller are considered with varying angle of attack authority. The three versions of the controller are evaluated using Monte Carlo simulations with expected dispersions.

Queen, Eric M.↗

Extracellular matrix and cell shape: potential control points for inhibition of angiogenesis

Capillary endothelial (CE) cells require two extracellular signals in order to switch from quiescence to growth and back to differentiation during angiogenesis: soluble angiogenic factors and insoluble extracellular matrix (ECM) molecules. Soluble endothelial mitogens, such as basic fibroblast growth factor (FGF), act over large distances to trigger capillary growth, whereas ECM molecules act locally to modulate cell responsiveness to these soluble cues. Recent studies reveal that ECM molecules regulate CE cell growth and differentiation by modulating cell shape and by activating intracellular chemical signaling pathways inside the cell. Recognition of the importance of ECM and cell shape during capillary morphogenesis has led to the identification of a series of new angiogenesis inhibitors. Elucidation of the molecular mechanism of capillary regulation may result in development of even more potent angiogenesis modulators in the future.

Non-NASA Center↗

Precision Pointing Control to and Accurate Target Estimation of a Non-Cooperative Vehicle

In 2004, NASA began investigating a robotic servicing mission for the Hubble Space Telescope (HST). Such a mission would not only require estimates of the HST attitude and rates in order to achieve capture by the proposed Hubble Robotic Vehicle (HRV), but also precision control to achieve the desired rate and maintain the orientation to successfully dock with HST. To generalize the situation, HST is the target vehicle and HRV is the chaser. This work presents a nonlinear approach for estimating the body rates of a non-cooperative target vehicle, and coupling this estimation to a control scheme. Non-cooperative in this context relates to the target vehicle no longer having the ability to maintain attitude control or transmit attitude knowledge.

VanEepoel, John↗

A CCD tracker for closed-loop instrument pointing at Halley's comet

An optical tracker based on CCD technology has been developed for the closed-loop pointing of the narrow-angle imaging system of the proposed Halley's comet intercept mission at the comet nucleus. The target tracker, needed to assure the accurate pointing of science instruments as the nucleus rapidly passes the spacecraft, is a component of the pointing control system, which also includes a two-axis articulated instrument platform and high-resolution optical encoders to measure platform orientation relative to spacecraft structure. The device was designed on the basis of a CCD imaging array to calculate target centroid position based on the optical intensity of all pixels containing the image, and a processor to perform spacecraft attitude control, pointing control and target tracker control and data processing functions. The tracker has been configured to operate in both target acquisition and tracking modes. Preliminary simulation results and past experiments on similar trackers indicate that excellent tracking performance can be achieved, and a breadboard version of the tracker is currently being fabricated.

Stanton, R. H.↗

Microthruster-Based Control for Precision Pointing of Next-Generation Space Telescopes

The next generation of space telescopes, such as the Habitable Exoplanet Observatory mission concept (HabEx), are expected to have milli-arcsecond-level pointing requirements at the spacecraft level. The pointing performance of such telescopes tends to be driven by internal rather than external disturbances, in particular reaction wheel jitter. This paper considers an architecture that relies on microthrusters instead of reaction wheels for spacecraft fine pointing, focusing on the HabEx mission concept as a case study. The proposed implementation uses micro-Newton-class colloidal thrusters that were tested in orbit as part of the ST7 payload on the LISA Pathfinder mission to reach Technical Readiness Level (TRL) 7. Key characteristics of these thrusters and the associated system trade-offs are first discussed. The resulting pointing control loop design is then described. Its ability to meet applicable pointing requirements is shown using three-degree-of-freedom simulations, where relevant disturbances are modelled. The control system is shown to reduce the pointing error by several orders of magnitude in about two hours, starting from coarse reaction control system (RCS) handover conditions. Once settled, the system meets the steady-state milli-arcsecond-level performance requirements with significant margin. Overall, the results show that microthruster-based pointing control architectures offer a promising alternative to traditional reaction-wheel-based designs for space telescope applications.

Ziemer, John↗

Publication of topographic atlas and control network of Mars

To aid planetary studies and the planning of future Mars missions, the Topographic Atlas and Control Network for Mars will be submitted by the end of fiscal year 1992 for publication as a NASA Special Publication. It will consist of reduced versions of 108 1:2 million-scale photomosaics that show contour lines from topographic maps at the same scale, as well as precisely located control points. The control points are from the planetwide network, which is not only instrumental in the compilation of maps at various scales, but is also widely used in other research such as studies of Mars' gravity and atmosphere. An example, a combination of MC 8-NW and -SW, of the photomosaics to be included in the atlas is presented. Contour lines in the figure are at 1-km intervals. The final adjusted ground coordinates and elevations of the 77 control points shown are given in table form. The last column in the table lists the topographic datum (zero elevation) that can be used to compute the solid radius of the control point from the center of mass of Mars. The atlas will also include information such as the adjusted C-matrices of each image, descriptions of the methods used, and their accuracy, and guidelines for users.

Wu, Sherman S. C.↗

Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal imaging routines including different standard MRI sequences.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-11: Moving a GPU-OpenCL-Based Monte Carlo (MC) Dose Engine Towards Routine Clinical Use: Automatic Beam Commissioning and Efficient Source Sampling

Purpose: We have previously developed a GPU-OpenCL-based MC dose engine named goMC with built-in analytical linac beam model. To move goMC towards routine clinical use, we have developed an automatic beam-commissioning method, and an efficient source sampling strategy to facilitate dose calculations for real treatment plans. Methods: Our commissioning method is to automatically adjust the relative weights among the sub-sources, through an optimization process minimizing the discrepancies between calculated dose and measurements. Six models built for Varian Truebeam linac photon beams (6MV, 10MV, 15MV, 18MV, 6MVFFF, 10MVFFF) were commissioned using measurement data acquired at our institution. To facilitate dose calculations for real treatment plans, we employed inverse sampling method to efficiently incorporate MLC leaf-sequencing into source sampling. Specifically, instead of sampling source particles control-point by control-point and rejecting the particles blocked by MLC, we assigned a control-point index to each sampled source particle, according to MLC leaf-open duration of each control-point at the pixel where the particle intersects the iso-center plane. Results: Our auto-commissioning method decreased distance-to-agreement (DTA) of depth dose at build-up regions by 36.2% averagely, making it within 1mm. Lateral profiles were better matched for all beams, with biggest improvement found at 15MV for which root-mean-square difference was reduced from 1.44% to 0.50%. Maximum differences of output factors were reduced to less than 0.7% for all beams, with largest decrease being from1.70% to 0.37% found at 10FFF. Our new sampling strategy was tested on a Head&Neck VMAT patient case. Achieving clinically acceptable accuracy, the new strategy could reduce the required history number by a factor of ∼2.8 given a statistical uncertainty level and hence achieve a similar speed-up factor. Conclusion: Our studies have demonstrated the feasibility and effectiveness of our auto-commissioning approach and new efficient source sampling strategy, implying the potential of our GPU-based MC dose engine goMC for routine clinical use.

61 RADIATION PROTECTION AND DOSIMETRY↗