Search NASA⌕ Search

SEARCH · Search NASA

Results for “Corrosion Mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Literature Review of Electromagnetic Pulse (EMP) and Geomagnetic Disturbance (GMD) Effects on Oil and Gas Pipeline Systems

This document summarizes the findings of a review of published literature regarding the potential impacts of electromagnetic pulse (EMP) and geomagnetic disturbance (GMD) phenomena on oil and gas pipeline systems. The impacts of telluric currents on pipelines and their associated cathodic protection systems has been well studied. The existing literature describes implications for corrosion protection system design and monitoring to mitigate these impacts. Effects of an EMP on pipelines is not a thoroughly explored subject. Most directly related articles only present theoretical models and approaches rather than specific analyses and in-field testing. Literature on SCADA components and EMP is similarly sparse and the existing articles show a variety of impacts to control system components that range from upset and damage to no effect. The limited research and the range of observed impacts for the research that has been published suggests the need for additional work on GMD and EMP and natural gas SCADA components.

02 PETROLEUM↗

Field Validation of Electrochemical Water Filtration System on Open Loop Cooling Towers at Automotive Plants

Open loop cooling towers play a pivotal role in rejecting heat for chilled water systems serving industrial processes, heating, ventilation, and air conditioning loads. Exposure to outside conditions can present certain operating challenges to system performance including scaling, corrosion, and biological growth. These issues are mitigated through the use of effective cooling tower water filtration and treatment systems to reduce contaminants—along with other total suspended solids (TSS) and total dissolved solids (TDS)—in the system. The U.S. Department of Energy’s Industrial Efficiency and Decarbonization Office is interested in an electrochemical-based filtration system with the ability to remove TSS particulate down to 1 micron. The removal of finer particulates reduces the need for blowdown and, in turn, makeup water use and chemical treatment in the cooling tower. Additionally, the removal process can reduce fouling at the condensers, resulting in better heat exchange and energy savings. Two Industrial Technology Validation program projects validated the electrochemical water filtration system at the Toyota Motor Manufacturing, Mississippi plant in Blue Springs, Mississippi, and the Nissan Canton Vehicle Assembly Plant in Canton, Mississippi. Researchers found that installation of both systems resulted in water and chemical treatment savings with minimal impact on energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold spray technology in nuclear energy applications: A review of recent advances

Cold spray technology is a promising solid-state, powder-based deposition methods for fabrication of coatings, near-net-shape manufacturing, and component repair. In recent years, this technology has been investigated for many applications in the nuclear energy sector. For example, it has been explored for the deposition of coatings of corrosion and oxidation materials on zirconium-alloys fuel claddings in light water reactors (LWR) for achieving more accident-tolerant fuel (ATF) cladding. Other examples of its use for nuclear energy applications include coatings for enhancements in wear resistance and heat transfer, near-net shape manufacturing of next-generation fuel claddings of oxide dispersion-strengthened (ODS) steels, and for mitigation and repair of potential chloride induced stress corrosion cracking in used fuel storage canister systems. This work reviews published literature on the application of cold spray process for nuclear energy applications, while pointing to gaps that have yet to be addressed.

36 MATERIALS SCIENCE↗

Diagnosing nuclear power plant pipe wall thinning due to flow accelerated corrosion using a passive, thermal non-destructive evaluation method: Feasibility assessment via numerical experiments

Flow accelerated corrosion (FAC) in nuclear power plant pipes is one of the leading causes of accidents, fatalities, damage and outages. Current FAC identification methods employ expensive sensing technology and are “active” methods, where the response of the piping system to an externally-generated thermal, mechanical or optical excitation must be measured. As a result, these techniques require a disruptive and time-consuming setup. Here we propose a method that utilizes pipe surface temperature measurements to passively monitor for FAC-induced pipe wall thinning without the need for expensive equipment or post-installation setup time. This diagnostic method utilizes a simulation data-driven diagnostic model to estimate the amount of thickness reduction in a pipe based on changes in measured steady-state pipe temperatures. In order to reduce the computational burden of generating large, simulation-based datasets, the behavior of the insulation of the pipe was modeled using a suitably calibrated heat transfer boundary parameter. Additionally, global sensitivity analysis was performed to determine system parameter(s), such as the temperature of water flowing inside the pipe, which significantly affect the steady state pipe wall temperature and could cause errors in diagnosis. Two diagnostic models, one using only the change in steady-state temperature as an indicator for FAC-induced pipe wall thinning and the other using water temperature as an additional diagnostic model input were evaluated for their ability to estimate thickness reductions in a pipe using simulated pipe wall temperature data. For the numerical experiments conducted in this work, both models estimated wall thickness with errors within 0.5 mm, indicating that the proposed technique can potentially be used as a low-cost, first-pass method for FAC monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Survey of baffle plate samples, specimen machining, and hydrogen measurements

This report outlines preliminary results on the survey and characterization of irradiated baffle plate, baffle former, and flux thimble tube specimens as part of the ongoing investigation into irradiation-induced embrittlement in austenitic stainless steels at ambient (room temperature) conditions. The specimens originated from commercial pressurized water reactor (PWR) components, covering displacement damage doses ranging from approximately 0.065 to 75 dpa. Initial scanning electron microscopy (SEM) surveys revealed that specimen surfaces exhibited fine machining marks and in-service-formed oxide layers on the side surfaces of the analyzed specimens. The oxide layers revealed specific features resembling localized "pitting-like" corrosion. An additional set of specimens representing in-service oxidation is being preserved for future microstructure analysis work. As believed, this will provide additional insights into long-term material degradation in PRWs. Specimen machining challenges emerged due to a complex failure of the electric discharge machining (EDM) system located in hot area. Despite partial restoration, issues persist with the EDM’s secondary power supply, necessitating the exploration of alternative EDM or computer numerical control (CNC) machining approaches to facilitate tensile specimen preparation. Currently, low speed saw cutting is in progress to prepare specimens for hydrogen measurements and general microstructure analysis. The near-term goals include completing tensile specimen machining for advanced mechanical testing and characterizing fracture mechanisms, and stress-corrosion cracking testing, ultimately aiming to identify and mitigate the ambient-condition intergranular cracking through targeted post-irradiation annealing strategies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Suppressing Universal Cathode Crossover in High‐Energy Lithium Metal Batteries via a Versatile Interlayer Design**

Abstract The universal cathode crossover such as chemical and oxygen has been significantly overlooked in lithium metal batteries using high‐energy cathodes which leads to severe capacity degradation and raises serious safety concerns. Herein, a versatile and thin (≈25 μm) interlayer composed of multifunctional active sites was developed to simultaneously regulate the Li deposition process and suppress the cathode crossover. The as‐induced dual‐gradient solid‐electrolyte interphase combined with abundant lithiophilic sites enable stable Li stripping/plating process even under high current density of 10 mA cm −2 . Moreover, X‐ray photoelectron spectroscopy and synchrotron X‐ray experiments revealed that N‐rich framework and CoZn dual active sites can effectively mitigate the undesired cathode crossover, hence significantly minimizing Li corrosion. Therefore, assembled lithium metal cells using various high‐energy cathode materials including LiNi 0.7 Mn 0.2 Co 0.1 O 2 , Li 1.2 Co 0.1 Mn 0.55 Ni 0.15 O 2 , and sulfur demonstrate significantly improved cycling stability with high cathode loading.

Xie, Chuyi↗

Suppressing Universal Cathode Crossover in High‐Energy Lithium Metal Batteries via a Versatile Interlayer Design**

Abstract The universal cathode crossover such as chemical and oxygen has been significantly overlooked in lithium metal batteries using high‐energy cathodes which leads to severe capacity degradation and raises serious safety concerns. Herein, a versatile and thin (≈25 μm) interlayer composed of multifunctional active sites was developed to simultaneously regulate the Li deposition process and suppress the cathode crossover. The as‐induced dual‐gradient solid‐electrolyte interphase combined with abundant lithiophilic sites enable stable Li stripping/plating process even under high current density of 10 mA cm −2 . Moreover, X‐ray photoelectron spectroscopy and synchrotron X‐ray experiments revealed that N‐rich framework and CoZn dual active sites can effectively mitigate the undesired cathode crossover, hence significantly minimizing Li corrosion. Therefore, assembled lithium metal cells using various high‐energy cathode materials including LiNi 0.7 Mn 0.2 Co 0.1 O 2 , Li 1.2 Co 0.1 Mn 0.55 Ni 0.15 O 2 , and sulfur demonstrate significantly improved cycling stability with high cathode loading.

25 ENERGY STORAGE↗

Highly reversible Zn metal anode enabled by sustainable hydroxyl chemistry

Rechargeable Zn metal batteries (RZMBs) may provide a more sustainable and lower-cost alternative to established battery technologies in meeting energy storage applications of the future. However, the most promising electrolytes for RZMBs are generally aqueous and require high concentrations of salt(s) to bring efficiencies toward commercially viable levels and mitigate water-originated parasitic reactions including hydrogen evolution and corrosion. Electrolytes based on nonaqueous solvents are promising for avoiding these issues, although full cell performance demonstrations with solvents other than water have been very limited. To address these challenges, we investigated MeOH as an alternative electrolyte solvent. These MeOH-based electrolytes exhibited exceptional Zn reversibility over a wide temperature range, with a Coulombic efficiency > 99.5% at 50% Zn utilization without cell short-circuit behavior for > 1,800 h. More important, this remarkable performance translates well to Zn || metal-free organic cathode full cells, supporting < 6% capacity decay after > 800 cycles at –40°C.

25 ENERGY STORAGE↗

Understanding Weld Formation and Microstructure Evolution in Laser Welded Stainless Steels and Ti-6Al-4V

High energy density welding processes are used for many industrial applications, such as aerospace and defense, and certain joint configurations and welding situations render post-weld inspection techniques difficult. Due to the inability to confirm penetration, there is a continual industrial need to improve prediction capabilities to aid in parameter selection. It is also necessary to understand the microstructural evolution to modify phase fractions and mitigate weldability related concerns such as solidification cracking or reduced corrosion performance.

42 ENGINEERING↗

Microstructural and Oxidation Effects of Nb Additions to U3Si2

U3Si2 is a long term, accident-tolerant nuclear fuel candidate for light-water reactors because of its superior thermal conductivity and increased uranium density when compared to traditional uranium dioxide (UO2). While reducing internal thermal stresses and increasing efficiency, U3Si2 exhibits energetic oxidation during certain off-normal and accident scenarios, which include coolant or steam exposure. To mitigate this, Nb is investigated as an alloy constituent to enhance corrosion resistance and increase mechanical strength. The work presented investigates the response of Nb-alloyed U3Si2 to steam atmospheres. A thermogravimetric analysis is conducted in flowing steam to T > 1000 °C to assess oxidation resistance. The phase characterization of as-melted, thermally annealed and post-oxidation compositions with up to 12 vol% Nb by powder X-ray diffraction, scanning electron microscopy, and energy dispersive spectroscopy is reported.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗

Corrosion Control in Carbon Fiber Reinforced Plastic (CFRP) Composite-Aluminum Closure Panel Hem Joints

This project targeted the implementation of CFRP/Al closure panels as a drop-in replacement for all-aluminum closures used in automobile production today. The project focused on the development of corrosion fundamentals involving CFRP materials and the use of those materials in mixed-material joints. Numerous studies were completed to benchmark current materials and test mixed metal joints. Good correlation was found between outdoor exposures and laboratory cyclic corrosion testing. The insights from the corrosion testing fundamentals and benchmarking phases informed the development of low-cure adhesive and electrocoats and conductive primers for the CFRP. Adhesive and electrocoat materials were successfully developed meeting low-cure targets for bake (150C/10min). These materials were scaled-up and used to produce 5 prototype liftgates to further evaluate CFRP/Al joints in a full-scale part. The lower cure materials enabled mitigation of CTE mismatch and reduced the required bake temperature, resulting in reduced part distortion. Corrosion testing of the liftgates revealed unexpected increases in corrosion relative to the standard bake materials. While rigorous evaluation of the parts was not possible due to numerous complexities associated with prototype testing, the results provided significant insights into the material behavior of CFRP/Al joints. Key learnings from the project included a better understanding of the system complexity (interplay of substrate/primer conductivity, production of full-scale prototypes), advances in coating/adhesive design for low-cure applications involving CFRP, and advancement of corrosion test protocols for CFRP.

36 MATERIALS SCIENCE↗

TEAMER: Biofouling Analysis for Wave Energy Piston Design - Load Cell Data

Biofouling and corrosion are a major concern for all ocean-deployed components, especially when mechanical motion is involved. Triton has developed the concept of a biofouling mitigation seal as part of the piston sealing assembly for the Triton Wave Energy Converter (TSI-WEC). This mitigation seal has the purpose of preventing the formation of a biofilm on the inside of the piston cylinder. It is hypothesized that the prevention of a biofilm will reduce the amount of macro-biofouling that can occur in the piston assembly. The mitigation seal can also reduce the wear on the main dynamic seal, helping to maintain smooth operation and water-tightness. The cylinder is made from a thermoset composite epoxy, which is resistant to corrosion. However, no studies have researched the material's performance with biofouling. Triton placed two prototype Power Take-Off (PTO) assemblies in a PNNL biofouling tank, one with a biofouling mitigation seal and one without, allowing for an evaluation of seal effectiveness at the prevention of biofouling. In actual WEC operation, wave action would react against the piston, which would drive the linear actuator and electric generator, providing electrical power. In the test setup, this was reversed; a linear actuator was powered to drive the piston in a consistent motion within the cylinder. There are two assemblies: one has a biofouling mitigation seal, the other (control) does not. The following data encompasses a 4 month test period, with load cells being used to monitor piston friction force. Results from this testing will be used to improve seal design and material selection, mitigating risk of premature failure during open water testing and evaluation. This project is part of the TEAMER RFTS 3 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

Statistical analysis and degradation pathway modeling of photovoltaic minimodules with varied packaging strategies

Degradation pathway models constructed using network structural equation modeling (netSEM) are used to study degradation modes and pathways active in photovoltaic (PV) system variants in exposure conditions of high humidity and temperature. This data-driven modeling technique enables the exploration of simultaneous pairwise and multiple regression relationships between variables in which several degradation modes are active in specific variants and exposure conditions. Durable and degrading variants are identified from the netSEM degradation mechanisms and pathways, along with potential ways to mitigate these pathways. A combination of domain knowledge and netSEM modeling shows that corrosion is the primary cause of the power loss in these glass/backsheet PV minimodules. We show successful implementation of netSEM to elucidate the relationships between variables in PV systems and predict a specific service lifetime. The results from pairwise relationships and multiple regression show consistency. This work presents a greater opportunity to be expanded to other materials systems.

electrical measurements↗

Investigation of Cold Spray as a Dry Storage Canister Repair and Mitigation Tool

The lack of a permanent spent nuclear fuel repository means utilities are faced with extending licenses for dry cask storage systems (DCSS) canisters far beyond their original 20-year license period. DCSS canisters are made from austenitic stainless steels (SSs) and fabricated using fusion welds. High heat input and melting associated with fabrication welds causes material around the weld to be susceptible to chloride-induced stress corrosion cracking (CISCC). The purpose of the work reported here is to investigate the use of cold spray for repair and mitigation of CISCC in DCSS canisters to ensure integrity far beyond their original license period. This report presents an analysis of cold spray for canister life extension, a summary of related efforts, relevant technology down selections, work accomplished, and future efforts relative to use of cold spray for repair and mitigation of CISCC in DCSS canisters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Materials for Energy-Water Systems: The Central Role of Water/Solid Interfaces in Adsorption, Reactivity, and Transport

The structure, chemistry, and charge of interfaces between materials and aqueous fluids play a central role in determining properties and performance of numerous water systems. Sensors, membranes, sorbents, and heterogeneous catalysts almost uniformly rely on specific interactions between their surfaces and components dissolved or suspended in the water-and often the water molecules themselves-to detect and mitigate contaminants. Deleterious processes in these systems such as fouling, scaling (inorganic deposits), and corrosion are also governed by interfacial phenomena. Despite the importance of these interfaces, much remains to be learned about their multiscale interactions. Developing a deeper understanding of the molecular- and mesoscale phenomena at water/solid interfaces will be essential to driving innovation to address grand challenges in supplying sufficient fit-for-purpose water in the future. In this Review, we examine the current state of knowledge surrounding adsorption, reactivity, and transport in several key classes of water/solid interfaces, drawing on a synergistic combination of theory, simulation, and experiments, and finally, provide an outlook for prioritizing strategic research directions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mitigation Methods for Piperazine Oxidation in Post-Combustion Carbon Capture

Piperazine is a promising second-generation solvent for amine scrubbing in post-combustion CO2 capture. However, the oxidative degradation of PZ can cause environmental problems and economic loss. This work presents the effects of two mitigation methods: carbon treating and N2 sparging, on the PZ oxidation in long-term operations. The species and their respective quantities adsorbed by the activated carbon were tested in a bench-scale device. The carbon was then tested in the High Temperature Oxidation Reactor (HTOR), where the solvent oxidizes at a reasonably fast rate. Pilot plant campaigns were also performed at the UT Austin SRP and the National Carbon Capture Center (NCCC) and the effects were verified. When dissolved Fe is removed by carbon treating or other methods, available soluble Fe in the system dissolves and replaces the dissolved Fe. Therefore, all available Fe and ligands need to be removed for the mitigation to be effective. The sources of soluble Fe include fly ash and the corrosion of stainless steel, and the ligands are degradation products. 8 All PZ degraded solvents have two absorbance peaks at 320 nm and 538 nm. The 320 nm peak is caused by dissolved metals, especially Fe, complexed by degradation products. The 320 nm peak is related to the amine degradation level and can be used as a simple and efficient method to estimate the amine degradation rate. The pilot plant data suggest that NO2 can oxidize PZ significantly, possibly through radical reactions. 0.01 mmol/kg-hr absorption of NO2 increased the PZ oxidation rate from 1.2 mmol/kg-hr to 2.5 mmol/kg-hr.

Yuying, Wu↗