Search NASA⌕ Search

SEARCH · Search NASA

Results for “DCC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Long Term Stability Monitoring of Aqua MODIS Thermal Emissive Bands through Radiative Transfer Modeling

Moderate Resolution Imaging Spectroradiometer (MODIS) on Aqua has been in operation providing continuous global observations for science research and applications since 2002. The long-term stability of thermal emissive bands (TEBs) of Aqua MODIS was monitored through inter-comparisons with measurements by hyperspectral infrared sensors, such as AIRS on Aqua and IASI on MetOp satellite, or through long term vicarious monitoring over cold targets, such as Dome- C and deep convective clouds (DCC). In this paper, a radiative transfer modeling-based simulation model using Community Radiative Transfer Model (CRTM) is developed to perform the long-term monitoring of the stability of TEBs of Aqua MODIS. CRTM is a fast-radiative transfer model for calculations of radiances for satellite infrared radiometers and is able to output infrared radiance and brightness temperature at spectral bands of MODIS. Long term European Centre for Medium-Range Weather Forecasts (ECMWF) global atmospheric reanalysis data, such as temperature and humidity profiles, are used as inputs to the CRTM simulation. By confining the area of interest to be over low to middle latitude ocean, the long-term stabilities of selected Aqua MODIS TEBs are monitored through Observation–Background (O-B) brightness temperature (BT) bias between MODIS measurements and BT retrieval from CRTM simulation. The consistency and relative stability between Aqua MODIS and ECMWF reanalysis data for surface channels of MODIS are evaluated. In addition, the radiative transfer modeling with CRTM enables us to evaluate the impacts of long term variation of global CO2 distribution on the O-B BT biases for CO2 channels of Aqua MODIS through comparison of simulations with constant or long term variable CO2 as inputs. The O-B analysis with RTM show that Aqua MODIS surface channels are all radiometrically stable with yearly BT bias drift less than 0.004K/year for B20, B22, B23 and ~0.01K/year for B31 and B32. The CO2 absorption channels of Aqua MODIS, e.g. B33-B36, are stable with BT bias drift < 0.005K/year.

MODIS↗

Understanding the Possible Effect of Scan Mirror Contamination in the AIRS Instrument

AIRS has provided highly stable and accurate radiances since 2002. Stability at the 2 mK/yr has been demonstrated relative to the sea surface temperature (SST) in the 8-12 micron window channels. However, there is evidence of a larger trend in the shortwave channels: 8mK/yr when viewing clear ocean at about 300K, about 200 mK/yr when viewing 220K DCC at night in the tropical oceans, but a trend of less than 20 mK/yr for Dome C at 220K. Under these conditions, the 8-12 micron window channels show trends of less than 20 mK/yr. This study proposes that the trends in the shortwave channels are the result of a wavelength dependent contamination of the scan mirror and the on-board calibration (OBC) black body. Scattered light from nearby scenes is removed via linear regression. An experiment that assumes the OBC black body emissivity has slightly decreased is tested. The emissivity experiment results show similar stability drifts to 1231 cm-1 but not to other window channels. The emissivity decrease may explain some of the stability drift, but some other physical mechanism is likely as well.

Broberg, Steve↗

Evaluation of Spectral Band Adjustment Factors for Cross-Calibration of Visible Imagers

The CERES EBAF dataset provides TOA SW and LW fluxes for long-term monitoring of the Earth’s energy balance and to validate climate models. The EBAF products, based on the Terra and Aqua CERES instrument observed radiances, rely on coincident measurements from the onboard MODIS imagers to determine cloud properties that are used in the angular distribution model scene selection required to convert the CERES observed radiances into flux values. Once the Terra and Aqua orbits start drifting outside of their 15-minute window, the CERES project will rely solely on the NOAA-20 CERES observations. A seamless transition of fluxes and clouds can only occur if the analogous MODIS and VIIRS channels are properly inter-calibrated. The visible band (0.65 µm) in MODIS (band 1) and VIIRS (M5 or I1) is critical for retrieving the cloud mask and optical depth. The spectral response functions (SRF) of these bands differ noticeably and will require scene dependent spectral band adjustment factors (SBAF) for proper radiometric scaling between them. Fortunately, the VIIRS I1 and M5 bands are calibrated using the same solar diffuser as a reference, which implies that band reflectance differences must be due to the spectral disparity. The coincident I1 and M5 TOA reflectance measurements provide the optimal opportunity to validate SBAFs over many surface and cloud conditions. The CERES project maintains SCIAMACHY, GOME-2, Hyperion, and radiative transfer model-based scene-stratified hyper-spectral reflectance measurements that can be convolved with sensor pair SRFs to compute the corresponding SBAF. This study will evaluate the SCIAMACHY, GOME-2, Hyperion, and RTM based SBAFs over tropical ocean targets used in SNO inter-calibration of MODIS and VIIRS, including clear-sky ocean, deep convective clouds (DCC), and liquid cloud targets in terms of their applicability to absolute intercomparison of visible imagers. The large SCIAMACHY and GOME-2 footprints and the lack of Hyperion cloudy scenes will impact the resulting SBAFs and necessitates the need for future CLARREO hyper-spectral reflectances to decrease SBAF uncertainties Preliminary results indicate that the SCIAMACHY and GOME-2 based SBAFs for the VIIRS I1 and M5 band pairs may differ by 1.5% for some ATO scene types. Because most of the modern GEOs visible band SRFs encompass the VIIRS I1 band SRF, these evaluations are critical to ensure that the MODIS, VIIRS, and GEO clouds and fluxes are consistent. SBAFs for Libya-4, Dome-C and other Earth invariant target will also be evaluated.

D. R. Doelling↗

Rapid Model Import Tool (RMIT) User Guide

The NASA Rapid Model Import Tool (RMIT) is designed to import 3D models built in commercially available Computer Aided Design (CAD) and Digital Content Creation (DCC) development software such as; Catia, Creo, 3DS Max, Maya, etc. Upon import, RMIT processes the models to reduce file size and exports the results in a format compatible with Augmented Reality (AR) and Virtual Reality (VR) development software applications. RMIT intends to make CAD models directly accessible to engineers from local AR/VR compatible laptops and desktops.

Joseluis Chavez↗

Observation of Deep Convective Cloud-Top Height and Vertical Temperature Structure of Hurricane Using Hyperspectral Infrared Sounder and its Single-Field-View Retrieval Products

Hurricanes, severe tropical cyclones (TC), or typhoons are significant natural disasters that often result in substantial loss of life and property damage. Numerous studies have indicated that changes in TC intensity are closely linked to deep convective clouds (DCC), with stronger TCs typically exhibiting higher cloud top heights (CTH) compared to weaker TCs. The CTH can help determine if a tropical depression is at the onset of rapid intensification based on case studies. Therefore, accurate determination of TC CTH will be greatly helpful for monitoring TC development and studying TC dynamics. One traditional and most common method to derive CHT from satellite observations is using the thermal brightness temperature in atmospheric channels to match the sounding temperature profile. However, it was found that thermally derived CTH has a lower bias of approximately 1 km, and this bias tends to worsen for the tallest clouds. A new method using the hyperspectral infrared sounder will be presented. From the measurements of Cross-track Infrared Sounder (CrIS) on S-NPP and J-1, along with radiative transfer simulations, we identified the inverted-V spectral feature in the ozone (O3) band (near 9.6 μm) corresponding to high clouds. The depth of the inverted-V can be used to estimate the CTH. Since the depth is computed using the peak absorption O3 channel and the nearby most transparent O3 channel in this O3 band, the uncertainties associated with cloud emissivity and scattering by cloud particles in the traditional method can be ignored. From several hurricane case studies, we found that the CHT derived using this method can accurately capture the structure of the cloud tops in the eyewall, spiral rainbands, and surrounding regions. For example, Hurricane Dorian on September 2, 2019, showed a nicely outward-sloping and circular shape eye cloud in the early morning, but the circular shape of the eyewall cloud became distorted in the afternoon. For various hurricanes we examined, the distribution of CHT for the eyewall clouds differed significantly. To better study the thermodynamic structure of hurricane clouds, this research will analyze the vertical temperature profiles from a new single Field of View (SFOV) Sounder Atmospheric Products (SiFSAP), derived using CrIS and the Advanced Technology Microwave Sounder (ATMS) onboard SNPP and JPSS-1. SiFSAP has a spatial resolution of 15 km at nadir, which surpasses most global weather and climate models and other current operational sounding products. The combined use of ATMS and CrIS allows for retrievals near hurricane eyewalls and spiral rainbands. Wind fields from NASA’s Modern-Era Retrospective Analysis for Research and Applications Version-2 (MERRA-2) and ERA5 will be used to characterize transport, and comparisons between the model temperature and water vapor profiles with the corresponding SiFSAP products will also be provided.

SiFSAP↗

Dynamic chemistry of anion recognition

In the past 40 years, anion recognition by synthetic receptors has grown into a rich and vibrant research topic, developing into a distinct branch of Supramolecular Chemistry. Traditional anion receptors comprise organic scaffolds functionalized with complementary binding groups that are assembled by multistep organic synthesis. Recently, a new approach to anion receptors has emerged, in which the host is dynamically self-assembled in the presence of the anionic guest, via reversible bond formation between functional building units. While coordination bonds were initially employed for the self-assembly of the anion hosts, more recent studies demonstrated that reversible covalent bonds can serve the same purpose. In both cases, due to their labile connections, the molecular constituents have the ability to assemble, dissociate, and recombine continuously, thereby creating a dynamic combinatorial library (DCL) of receptors. The anionic guests, through specific molecular recognition, may then amplify (express) the formation of a particular structure among all possible combinations (real or virtual) by shifting the equilibria involved towards the most optimal receptor. This approach is not limited to solution self-assembly, but is equally applicable to crystallization, where the fittest anion-binding crystal may be selected. Finally, the pros and cons of employing dynamic combinatorial chemistry (DCC) vs molecular design for developing anion receptors, and the implications of both approaches to selective anion separations, will be discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed Cooperative Control of Hybrid AC/DC Microgrid

This paper presents a distributed cooperative control-based (DCC) power management algorithm for a hybrid AC/DC microgrid. The proposed algorithm for a hybrid microgrid system controls the power flow through the interface converter between the AC and DC microgrids. This algorithm allows power sharing between the distributed generators in the microgrid according to their power ratings. Moreover, it enables the fixed scheduled power delivery through the interface converters in both directions at different operating conditions while maintaining voltage regulation and improving the frequency profile.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OSU High Temperature Test Facility Design Technical Report, Revision 2

The HTTF is an integral test facility, which has been designed to model the behavior of interest for a MHTGR during the Depressurized Conduction Cooldown (DCC) event. It also has the potential to conduct limited explorations into the progression of the Pressurized Conduction Cooldown (PCC) event and phenomena during normal operations. The facility is scaled 1:4 by height and 1:64 by volume. A scaling report has been developed and provides further detail into the scaling analysis for the HTTF. The maximum core power for the facility is approximately 2.2MW. The core region will be of a modular design to allow for both the prismatic block core and the pebble bed core designs to be tested. However, only the prismatic block design is discussed in this report. The HTTF consists of the following systems: A primary system consisting of the reactor pressure vessel (RPV), the circulator, cross over ducts and primary piping. The core internals sit inside the RPV and provide support for the core and core heaters. The purpose of the primary system is to maintain the pressure boundary, remove heat from the core through convection, conduction and radiation, and provide heat to the core through a series of electrical heaters. A secondary system consisting of a steam generator, feed water system and main steam system. The purpose of the secondary system is to remove heat from the primary system during heat up, cool down and normal operations. A reactor cavity simulation system consisting of a cavity tank, gas conditioning system and a series of break valves. Note that the prototypical MHTGR sits inside of a cavity. In the event of a break the helium will blowdown into this cavity. At the HTTF, the cavity is modeled as a separate tank, the reactor cavity simulation tank (RCST) and is connected to the RPV through break valves—hot-leg, cold-leg, upper break, and lower break. A reactor cavity cooling system (RCCS) consisting of a series of water cooled panels and the water supply system for these panels. The HTTF RCCS is not a scaled prototypical RCCS system for the MHTGR. It is provided in the HTTF in order to set the boundary condition for radiation heat transfer from the RPV. Various auxiliary systems including the city water supply system, the electrical power supply and distribution system, the chilled water system and the instrument air system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Instrumentation Plan for the OSU High Temperature Test Facility, Revision 4

This instrumentation plan describes the instrumentation requirements and design for the Oregon State University (OSU) High Temperature Test Facility (HTTF). This report outlines HTTF instrumentation design specifications, data acquisition and control system (DACS) design specifications as well as a brief description of the instrumentation to be used in the HTTF. The HTTF is an integral test facility, which has been designed to model the behavior of interest for a Very High Temperature Gas Reactor (VHTR) during the Depressurized Conduction Cooldown (DCC) event. It also has the potential to conduct limited explorations into the progression of the Pressurized Conduction Cooldown (PCC) event and phenomena during normal operations. The facility is scaled 1:4 by height and 1:64 by volume. The maximum core power for the facility is approximately 2.2MW. The core region is of a modular design to allow for both the prismatic block core and the pebble bed core designs to be tested. However, only the prismatic block design is discussed in this report. A correctly scaled integral facility modeling the VHTR that can be used to examine the thermal hydraulic system behavior of the design basis and beyond design basis transients is of significant value. The experimental results obtained in such a program could be used to validate analytical tools and methods being proposed for use with the VHTR. Therefore, it is of importance that the HTTF be instrumented in such a way that the required data is collected to meet its overall goals of phenomena examination and code validation. In addition to the instrumentation used to collect data to achieve the overall goals of the HTTF test program, there is instrumentation in the HTTF, which is primarily used to ensure the safe operation of the test facility. This type of instrumentation shall be termed “Control Instrumentation” and is discussed in this report. This report discusses the DACS, which is a personal computer controlled system that is used to control both the collection and storage of the test matrix and control system data as well as electrical and mechanical operation of the test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF)

HTTF at Oregon State University (OSU) Reference: General Atomics? modular high-temperature gas-cooled reactor Helium cooled, electrically heated Prismatic graphite blocks in the core and reflectors Alumina ceramic blocks are used to simulate the core and top and bottom reflectors One-fourth scale in length and diameter Most of the coolant channels in the core are full scale Lower pressure compared to the prototype reactor Over 500 instruments Designed primarily to investigate depressurized conduction cooldown (DCC) transients

97 MATHEMATICS AND COMPUTING↗

RELAP5-3D Simulation of PG-27 Test at the HTTF Facility

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a quarter scaled integral-effect test facility designed to examine the transient phenomena occurring in a Modular Hight Temperature Gas-cooled Reactor (MHTGR). It is specifically designed to handle the pressurized and depressurized conduction cooldown (PCC and DCC) events. The PCC event is an accident scenario in which there is a loss of forced convection of the coolant through the system. However, the pressure boundary remains intact. This study focuses on the Reactor Excursions and Leak Analysis Program (RELAP)5-3D simulation of the PG-27 test (PCC phenomena) and the sensitivity of those simulations from the material properties and primary helium mass flow rate standpoint. The aim is to capture a reasonable one-dimensional picture of a three dimensional phenomena. The simulation will help in the code assessment and in understanding the various unknown parameters involved. The presented results will demonstrate the code is able to capture the detailed one-dimensional physics accurately. However, input parameters to the code (i.e., the primary mass flow rate, refractory material thermal conductivity, and heat capacity at elevated temperatures) impact the fuel temperature the most. This work will discuss the sensitivity of simulations to the identified input parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Revisions to US EPA Superfund Risk and Dose Assessment Models and Guidance - 13403

The U.S. Environmental Protection Agency (EPA) Superfund program's six Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) internet based calculators for risk and dose assessment at Superfund sites are being revised to reflect better science, revisions to existing exposure scenarios and new scenarios, and changes to match up more closely with the EPA chemical regional screening level calculator. A revised version of the 1999 guidance document that provides an overview for the Superfund risk assessment process at radioactively contaminated sites, 'Radiation Risk Assessment At CERCLA Sites: Q and A', is being completed that will reflect Superfund recommended guidance and other technical documents issued over the past 13 years. EPA is also issuing a series of fact sheets in the document 'Superfund Radiation Risk Assessment: A Community Tool-kit'. This presentation would go over those changes that are expected to be finished by this spring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Superfund Update: Revisions to Risk and Dose Assessment Tools - 17302

The U.S. Environmental Protection Agency (EPA) Superfund remedial program is finishing up a significant number of revisions to its guidance for the risk assessment process at radioactively contaminated Superfund sites. The six Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) internet based calculators for risk and dose assessment at Superfund sites are being revised to reflect better science, revisions to existing exposure scenarios and new scenarios, and changes to match up more closely with the EPA chemical regional screening level calculator. A comprehensive set of revisions to the PRG calculator was finished in November 2014. Additional revisions to the other 5 calculators were made in. A set of further revisions are expected to be finalized prior to December 2016 and will be discussed in this abstract. There are several additional revisions that may be finished prior to WM 2017 and will be presented if finished or discussed in more general terms if still underway. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

US EPA superfund radiation risk assessment update: new, revised, and upcoming tools - 15350

The U.S. EPA Superfund remedial program is finishing up a significant number of revisions to its guidance for the risk assessment process at radioactively contaminated Superfund sites. The six Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) internet based calculators for risk and dose assessment at Superfund sites are being revised to reflect better science, revisions to existing exposure scenarios and new scenarios, and changes to match up more closely with the EPA chemical regional screening level calculator. A comprehensive set of revisions to the PRG calculator will be finished in November 2014. A revised version of the 1999 guidance document that provides an overview for the Superfund risk assessment process at radioactively contaminated sites, 'Radiation Risk Assessment At CERCLA Sites: Q and A' was issued on June 13, 2014 reflects Superfund recommended guidance and other technical documents issued over the past 15 years. Also on June 13, 2014 EPA issued a new tool-kit comprised of 22 fact sheets that was developed to help the general public understand more about EPA's risk assessment process used at radioactively contaminated Superfund sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

US EPA Superfund Radiation Risk Assessment Update: New, Revised, and Upcoming Tools - 16308

The U.S. Environmental Protection Agency (EPA) Superfund remedial program is finishing up a significant number of revisions to its guidance for the risk assessment process at radioactively contaminated Superfund sites. The six Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) internet based calculators for risk and dose assessment at Superfund sites are being revised to reflect better science, revisions to existing exposure scenarios and new scenarios, and changes to match up more closely with the EPA chemical regional screening level calculator. A comprehensive set of revisions to the PRG calculator was finished in November 2014. Additional revisions to the other 5 calculators were made in 2015 and are discussed in this paper. Further revisions are expected prior to WM and will be presented if finished or discussed in more general terms if still underway. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using EPA's Risk Assessment Tools for Superfund When Addressing Removal Actions and Late-Phase Response to Terrorist Attacks - 18228

EPA's Office of Superfund Remediation and Technology Innovation (OSRTI) has three internet based calculators, or risk assessment models, for developing risk based Preliminary Remediation Goals (PRGs) for radioactively contaminated CERCLA sites. These PRG calculators are EPA's recommended methodology for developing risk-based concentrations for remedial actions for soil and water (PRG), inside buildings (BPRG), and outside hard surfaces (SPRG). EPA has three equivalent calculators for dose assessment, which are the Dose Compliance Concentration (DCC) calculator for soil and water, inside buildings (BDCC), and outside hard surfaces (SDCC). The three PRG calculators also include default PRG tables provided for each of the calculators showing concentrations corresponding to 1 x 10-6 when the calculators are run using all of their default parameters. This presentation will provide information on how users may employ these tools beyond their original intended uses in the remedial program, to develop risk based cleanup levels during the late-phase portion of an actual response after a Radiological Dispersal Device (RDD) or Improvised Nuclear Device (IND) terrorist attack or a major accident at a Nuclear Power Plant (NPP), or a simulation during an exercise of an RDD/IND/NPP event, they may want to run the calculator using more site-specific data. This presentation will provide information on how users may employ these tools beyond their original intended uses in the remedial program, and focus on some of the more conservative default parameters that are likely candidates for replacement by site-specific information. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

US EPA Superfund Radiation Risk Assessment Update: Superfund Update: Revisions to Risk and Dose Assessment Tools - 18232

The U.S. Environmental Protection Agency (EPA) Superfund remedial program is finishing up a significant number of revisions to its guidance for the risk assessment process at radioactively contaminated Superfund sites. The six Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) internet based calculators for risk and dose assessment at Superfund sites are being revised to reflect better science, revisions to existing exposure scenarios and new scenarios, and changes to match up more closely with the EPA chemical regional screening level calculator. A comprehensive set of revisions to the PRG calculator was finished in November 2014. Additional revisions to the other 5 calculators were made in 2015. A set of further revisions are expected to be finalized prior to December 2016 and will be discussed in this abstract. There are several additional revisions that may be finished prior to WM 2017 and will be presented if finished or discussed in more general terms if still underway. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗