At least 163 records · Page 9

Fast image decompression for telebrowsing of images

Progressive image transmission (PIT) is often used to reduce the transmission time of an image telebrowsing system. A side effect of the PIT is the increase of computational complexity at the viewer's site. This effect is more serious in transform domain techniques than in other techniques. Recent attempts to reduce the side effect are futile as they create another side effect, namely, the discontinuous and unpleasant image build-up. Based on a practical assumption that image blocks to be inverse transformed are generally sparse, this paper presents a method to minimize both side effects simultaneously.

Miaou, Shaou-Gang↗

Organizing Compression of Hyperspectral Imagery to Allow Efficient Parallel Decompression

family of schemes has been devised for organizing the output of an algorithm for predictive data compression of hyperspectral imagery so as to allow efficient parallelization in both the compressor and decompressor. In these schemes, the compressor performs a number of iterations, during each of which a portion of the data is compressed via parallel threads operating on independent portions of the data. The general idea is that for each iteration it is predetermined how much compressed data will be produced from each thread.

Klimesh, Matthew A.↗

Using an Ultrasonic Instrument to Size Extravascular Bubbles

In an ongoing development project, microscopic bubbles in extravascular tissue in a human body will be detected by use of an enhanced version of the apparatus described in Ultrasonic Bubble- Sizing Instrument (MSC-22980), NASA Tech Briefs, Vol. 24, No. 10 (October 2000), page 62. To recapitulate: The physical basis of the instrument is the use of ultrasound to excite and measure the resonant behavior (oscillatory expansion and contraction) of bubbles. The resonant behavior is a function of the bubble diameter; the instrument exploits the diameter dependence of the resonance frequency and the general nonlinearity of the ultrasonic response of bubbles to detect bubbles and potentially measure their diameters. In the cited prior article, the application given most prominent mention was the measurement of gaseous emboli (essentially, gas bubbles in blood vessels) that cause decompression sickness and complications associated with cardiopulmonary surgery. According to the present proposal, the instrument capabilities would be extended to measure extravascular bubbles with diameters in the approximate range of 1 to 30 m. The proposed use of the instrument could contribute further to the understanding and prevention of decompression sickness: There is evidence that suggests that prebreathing oxygen greatly reduces the risk of decompression sickness by reducing the number of microscopic extravascular bubbles. By using the ultrasonic bubble-sizing instrument to detect and/or measure the sizes of such bubbles, it might be possible to predict the risk of decompression sickness. The instrument also has potential as a tool to guide the oxygen-prebreathing schedules of astronauts; high-altitude aviators; individuals who undertake high-altitude, low-opening (HALO) parachute jumps; and others at risk of decompression sickness. For example, an individual at serious risk of decompression sickness because of high concentrations of extravascular microscopic bubbles could be given a warning to continue to prebreathe oxygen until it was safe to decompress.

Magari, Patrick J.↗

Doppler indices of gas phase formation in hypobaric environments: Time-intensity analysis

A semi-quantitative method to analyze decompression data is described. It possesses the advantage that it allows a graded response to decompression rather than the dichotomous response generally employed. A generalized critical volume (C-V), or stoichiometric time-dependent equilibrium model is examined that relates the constant of the equation P sub i equals m P sub f plus b to variable tissue supersaturation and gas washout terms. The effects of the tissue ratio on gas phase formation indicate that a decreased ratio yields fewer individuals with Doppler detectable gas bubbles, but those individuals still present with Spencer Grade 3 or 4. This might indicate a local collapse of tissue saturation. The individuals with Grade 3 or 4 could be at risk for type 2 decompression sickness by transpulmonic arterialization. The primary regulator of the problems of decompression sickness is the reduction of local supersaturation, presumably governed by the presence and number of gas micronuclei. It is postulated that a reduction in these nuclei will favor a low incidence of decompression sickness in microgravity secondary to hypokinesia and adynamia.