Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIFFERENTIAL AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Superconducting gravity gradiometer and a test of inverse square law

The equivalence principle prohibits the distinction of gravity from acceleration by a local measurement. However, by making a differential measurement of acceleration over a baseline, platform accelerations can be cancelled and gravity gradients detected. In an in-line superconducting gravity gradiometer, this differencing is accomplished with two spring-mass accelerometers in which the proof masses are confined to motion in a single degree of freedom and are coupled together by superconducting circuits. Platform motions appear as common mode accelerations and are cancelled by adjusting the ratio of two persistent currents in the sensing circuit. The sensing circuit is connected to a commercial SQUID amplifier to sense changes in the persistent currents generated by differential accelerations, i.e., gravity gradients. A three-axis gravity gradiometer is formed by mounting six accelerometers on the faces of a precision cube, with the accelerometers on opposite faces of the cube forming one of three in-line gradiometers. A dedicated satellite mission for mapping the earth's gravity field is an important one. Additional scientific goals are a test of the inverse square law to a part in 10(exp 10) at 100 km, and a test of the Lense-Thirring effect by detecting the relativistic gravity magnetic terms in the gravity gradient tensor for the earth.

Moody, M. V.↗

A versatile low-temperature setup for the electrical characterization of single-molecule junctions

We present a modular high-vacuum setup for the electrical characterization of single molecules down to liquid helium temperatures. The experimental design is based on microfabricated mechanically controllable break junctions, which offer control over the distance of two electrodes via the bending of a flexible substrate. The actuator part of the setup is divided into two stages. The slow stage is based on a differential screw drive with a large bending range. An amplified piezoceramic actuator forms the fast stage of the setup, which can operate at bending speeds of up to 800 {mu}m/s. In our microfabricated break junctions this is translated into breaking speeds of several 10 nm/s, sufficient for the fast acquisition of large statistical datasets. The bandwidth of the measurement electronics has been optimized to enable fast dI/dV spectroscopy on molecular junctions with resistances up to 100 M{Omega}. The performance of the setup is demonstrated for a {pi}-conjugated oligo(phenylene-ethynylene)-dithiol molecule.

36 MATERIALS SCIENCE↗

Driving disk winds and heating hot coronae by MRI turbulence

We investigate the formation of hot coronae and vertical outflows in accretion disks by magnetorotational turbulence. We perform local three-dimensional magnetohydrodynamical (MHD) simulations with the vertical stratification by explicitly solving an energy equation with various effective ratios of specific heats, γ. Initially imposed weak vertical magnetic fields are effectively amplified by magnetorotational instability and winding caused by the differential rotation. In the isothermal case (γ = 1), the disk winds are driven mainly by the Poynting flux associated with the MHD turbulence and show quasi-periodic intermittency. In contrast, in the non-isothermal cases with γ ≥ 1.1, the regions above 1-2 scale heights from the midplane are effectively heated to form coronae with temperature ∼50 times the initial value, which are connected to the cooler midplane region through the pressure-balanced transition regions. As a result, the disk winds are driven mainly by the gas pressure, exhibiting more time-steady nature, although the nondimensional time-averaged mass loss rates are similar to that of the isothermal case. Sound-like waves are confined in the cool midplane region in these cases, and the amplitude of the density fluctuations is larger than that of the isothermal case.

79 ASTRONOMY AND ASTROPHYSICS↗

Resonant Control for Fermilab's PXIE RFQ

The RFQ for Fermilab's PXIE test program is designed to accelerate a < 10 mA H⁻ CW beam to 2.1 MeV. The RFQ has a four-vane design, with four modules brazed together for a total of 4.45 m in length. The RF power required is < 130 kW at 162.5 MHz. A 3 kHz limit on the maximum allowable frequency error is imposed by the RF amplifiers. This frequency constraint must be managed entirely through differential cooling of the RFQ's vanes and outer body and associated material expansion. Simulations indicate that the body and vane coolant temperature should be controlled to within 0.1 degrees C. We present the design of the cooling network and the resonant control algorithm for this structure, as well as results from initial operation.

43 PARTICLE ACCELERATORS↗

Scintillation counter and wire chamber front end modules for high energy physics experiments

This document describes two front-end modules developed for the proposed MIPP upgrade (P-960) experiment at Fermilab. The scintillation counter module was developed for the Plastic Ball detector time and charge measurements. The module has eight LEMO 00 input connectors terminated with 50 ohms and accepts negative photomultiplier signals in the range 0.25...1000 pC with the maximum input voltage of 4.0 V. Each input has a passive splitter with integration and differentiation times of {approx}20 ns. The integrated portion of the signal is digitized at 26.55 MHz by Analog Devices AD9229 12-bit pipelined 4-channel ADC. The differentiated signal is discriminated for time measurement and sent to one of the four TMC304 inputs. The 4-channel TMC304 chip allows high precision time measurement of rising and falling edges with {approx}100 ps resolution and has internal digital pipeline. The ADC data is also pipelined which allows deadtime-less operation with trigger decision times of {approx}4 {micro}s. The wire chamber module was developed for MIPP EMCal detector charge measurements. The 32-channel digitizer accepts differential analog signals from four 8-channel integrating wire amplifiers. The connection between wire amplifier and digitizer is provided via 26-wire twist-n-flat cable. The wire amplifier integrates input wire current and has sensitivity of 275 mV/pC and the noise level of {approx}0.013 pC. The digitizer uses the same 12-bit AD9229 ADC chip as the scintillator counter module. The wire amplifier has a built-in test pulser with a mask register to provide testing of the individual channels. Both modules are implemented as a 6Ux220 mm VME size board with 48-pin power connector. A custom europack (VME) 21-slot crate is developed for housing these front-end modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A program to evaluate a control system based on feedback of aerodynamic pressure differentials, part 1

The use of pressure differentials in a flight control system was evaluated. The pressure profile around the test surface was determined using two techniques: (1) windtunnel data (actual); and (2) NASA/Langley Single Element Airfoil Computer Program (theoretical). The system designed to evaluate the concept of using pressure differentials is composed of a sensor drive and power amplifiers, actuator, position potentiometer, and a control surface. The characteristics (both desired and actual) of the system and each individual component were analyzed. The desired characteristics of the system as a whole are given. The flight control system developed, the testing procedures and data reduction methods used, and theoretical frequency response analysis are described.

Hrabak, R. R.↗

$\mathrm{SageNet}$: Fast Neural Network Emulation of the Stiff-amplified Gravitational Waves from Inflation

Accurate modeling of the inflationary gravitational waves (GWs) requires time-consuming, iterative numerical integrations of differential equations to take into account their backreaction on the expansion history. To improve computational efficiency while preserving accuracy, we present the Stiff-amplified Gravitational-wave Emulator Network (SageNet), a deep learning framework designed to replace conventional numerical solvers (code available at https://github.com/YifangLuo/SageNet). SageNet employs a long short-term memory architecture to emulate the present-day energy density spectrum of the inflationary GWs with possible stiff amplification, Ω GW (f). Trained on a data set of 25,689 numerically generated solutions, SageNet allows accurate reconstructions of Ω GW (f) and generalizes well to a wide range of cosmological parameters; 90.9% of the test emulations with randomly distributed parameters exhibit errors of under 4%. In addition, SageNet demonstrates its ability to learn and reproduce the artificial, adaptive sampling patterns in numerical calculations, which implement denser sampling of frequencies around changes in spectral indices in Ω GW (f). The dual capability of learning both physical and artificial features of the numerical GW spectra establishes SageNet as a robust alternative to exact numerical methods. Finally, our benchmark tests show that SageNet reduces the computation time from tens of seconds to milliseconds, achieving a speedup of ∼10 4 times over standard CPU-based numerical solvers with the potential for further acceleration on GPU hardware. These capabilities make SageNet a powerful tool for accelerating Bayesian inference procedures for extended cosmological models. In a broad sense, the SageNet framework offers a fast, accurate, and generalizable solution to modeling cosmological observables whose theoretical predictions demand costly differential equation solvers.

Astronomy data modeling↗

Semianalytic theory of self-similar optical propagation and mode locking using a shape-adaptive model pulse

A semianalytic theory for the pulse dynamics in similariton amplifiers and lasers is presented, based on a model pulse with adaptive shape. By changing a single parameter, this test function can be continuously tweaked between a pure Gaussian and a pure parabolic profile and can even represent sech-like pulses, the shape of a soliton. This approach allows us to describe the pulse evolution in the self-similar and other regimes of optical propagation. Employing the method of moments, the evolution equations for the characteristic pulse parameters are derived from the governing nonlinear Schroedinger or Ginzburg-Landau equation. Due to its greatly reduced complexity, this description allows for extensive parameter optimization, and can aid intuitive understanding of the dynamics. As an application of this approach, we model a soliton-similariton laser and validate the results against numerical simulations. This constitutes a semianalytic model of the soliton-similariton laser. Due to the versatility of the model pulse, it can also prove useful in other application areas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of a Kelvin-Helmholtz Instability in a High-Energy-Density Plasma on the Omega Laser

A laser initiated experiment is described in which an unstable plasma shear layer is produced by driving a blast wave along a plastic surface with sinusoidal perturbations. In response to the vorticity deposited and the shear flow established by the blast wave, the interface rolls up into large vortices characteristic of the Kelvin-Helmholtz (KH) instability. The experiment used x ray radiography to capture the first well-resolved images of KH vortices in a high-energy-density plasma, and possibly the first images of transonic shocks generated by large-scale structures in a shear layer. The physical processes governing the evolution of a stratified fluid flow with a large velocity gradient (i.e., a shear flow) are of fundamental interest to a wide range of research areas including combustion, inertial confinement fusion (ICF), stellar supernovae, and geophysical fluid dynamics. Traditional experiments have used inclined tanks of fluid to initiate a flow, generally at low Reynolds numbers, or wind tunnels that combine two parallel gas flows at the end of a thin wedge, known as a splitter plate. The splitter plate experiments have explored flows with maximum shear velocities on the order of 10{sup 3} m/s and Reynolds numbers up to 10{sup 6}. Here we report the creation of a novel type of shear flow, achieved by confining a laser driven blast wave in a millimeter-sized shock tube, which produced shear velocities on the order of 10{sup 4} m/s and Reynolds numbers of 10{sup 6} in a plasma. This system enabled the first apparent observation of transonic shocklets, which are small, localized shocks believed to develop in response to a local supersonic flow occurring over a growing perturbation. These shocklets have been predicted previously in simulations, but have never to our knowledge been observed. These experiments are also the first to observe the growth of perturbations by the Kelvin-Helmholtz (KH) instability under high-energy-density (HED) conditions. In all flows having steep enough shear layers, small perturbations that initially develop on an interface are amplified by KH, driven by lift forces that result from differential flow across the perturbation. As the KH instability enters its non-linear regime the growth of the perturbation begins to saturate, at which point the interaction of secondary instabilities with the primary perturbation causes the flow to transition to a fully turbulent state. HED plasmas are created when an energy source, a multi-kilojoule laser in this case, creates pressures of order one Mbar or more. Such plasmas are compressible, actively ionizing, often involve strong shock waves, and have complex material properties. The one previous attempt to produce a shear flow under HED conditions was inconclusive and did not observe KH growth. The KH instability and shear flow effects in general are also of practical importance in a number of HED systems. They should be considered in multi-shock implosion schemes for direct drive capsules for inertial confinement fusion (ICF), since the KH instability may accelerate the growth of a turbulent mixing layer at the interface between the ablator and solid deuterium-tritium nuclear fuel. Some approaches to ICF (e.g., fast ignition) produce shear flows qualitatively similar to those discussed here. Some supernova explosion models also find that KH plays an important role. In addition, the experiments and simulations of HED and astrophysical systems have shown that structures driven by shear flow appear on the high-density spikes produced by the Rayleigh-Taylor (RT) and Richtmyer-Meshkov (RM) instabilities. Both RT and RM have important consequences for the evolution of ionized, compressible flows, including those found in ICF and astrophysical systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inductive Learning Approaches for Improving Pilot Awareness of Aircraft Faults

Neural network flight controllers are able to accommodate a variety of aircraft control surface faults without detectable degradation of aircraft handling qualities. Under some faults, however, the effective flight envelope is reduced; this can lead to unexpected behavior if a pilot performs an action that exceeds the remaining control authority of the damaged aircraft. The goal of our work is to increase the pilot s situational awareness by informing him of the type of damage and resulting reduction in flight envelope. Our methodology integrates two inductive learning systems with novel visualization techniques. One learning system, the Inductive Monitoring System (IMS), learns to detect when a simulation includes faulty controls, while two others, Inductive Classification System (INCLASS) and multiple binary decision tree system (utilizing C4.5), determine the type of fault. In off-line training using only non-failure data, IMS constructs a characterization of nominal flight control performance based on control signals issued by the neural net flight controller. This characterization can be used to determine the degree of control augmentation required in the pitch, roll, and yaw command channels to counteract control surface failures. This derived information is typically sufficient to distinguish between the various control surface failures and is used to train both INCLASS and C4.5. Using data from failed control surface flight simulations, INCLASS and C4.5 independently discover and amplify features in IMS results that can be used to differentiate each distinct control surface failure situation. In real-time flight simulations, distinguishing features learned during training are used to classify control surface failures. Knowledge about the type of failure can be used by an additional automated system to alter its approach for planning tactical and strategic maneuvers. The knowledge can also be used directly to increase the pilot s situational awareness and inform manual maneuver decisions. Our multi-modal display of this information provides speech output to issue control surface failure warnings to a lesser-used communication channel and provides graphical displays with pilot-selectable !eve!s of details to issues additional information about the failure. We also describe a potential presentation for flight envelope reduction that can be viewed separately or integrated with an existing attitude indicator instrument. Preliminary results suggest that the inductive approach is capable of detecting that a control surface has failed and determining the type of fault. Furthermore, preliminary evaluations suggest that the interface discloses a concise summary of this information to the pilot.

Spikovska, Lilly↗

Investigation into the Origin of the RF Phase Noise for the LISA Laser Transmitter

The Laser Interferometer Space Antenna (LISA) mission is a collaborative consortium led by the European Space Agency (ESA)in cooperation with the National Aeronautics and Space Administration (NASA). LISA’s goal is to capture gravitational wave events, such as spacetime distortions caused by massive orbiting bodies. Multiple low noise, single frequency master oscillator power amplifier (MOPA) lasers with a polarization-maintaining Yb-fiber amplifier will serve as the light sources for the LISA observatory. The NASA Goddard Space Flight Center (GSFC)is currently developing the laser transmitters for this project. The LISA lasers will carry radio frequency (RF)sidebands for exchanging reference RF clock information between spacecrafts. Excess phase noise, especially carrier-sideband differential phase noise added to the modulation side band by the phase modulator and the fiber amplifier, becomes a concern. In the gravitational wave frequency ranges, leading sources of this RF “differential” phase noise can be both intrinsic and extrinsic. Examples of intrinsic sources include thermal load on the active fiber, thermo-mechanical induced birefringence, and nonlinearities in the various passive and active fibers. Extrinsic sources can include external temperature fluctuations and infrasonic mechanical strain or vibrations. These noise spectra usually include both white and pink (1/f) thermal noise contributions. This work investigates the physical origins and impact of these sources of RF phase noise, and their characteristic spectra and management will be discussed.

Laser Interferometer Space Antenna↗

Sense amplifier with transistor threshold compensation

One embodiment provides, in a sense amplifier for an electronic memory array in which a selected memory cell drives a developing voltage differential according to a logic state of the memory cell, a method to store the logic state. The method includes poising source voltages of first and second transistors at levels offset, respectively, by threshold voltages of the first and second transistors. The method also includes applying the voltage differential between a gate of the first transistor and a gate of the second transistor, the first and second transistors configured to oppose each other in a cross-coupled inverter stage of the sense amplifier.

Sinangil, Mahmut E.↗

Fabrication and evaluation of large-area ultrasoft X-ray detectors suitable for spacecraft application

The modifications to the Houston/MSC design of the gas proportional counter flight electronics system are discussed. The following modifications are described: charge amplifier bandwidth improvements, power converter redesign, serial data output buffer, second differentiator, and risetime discriminator. In addition, the redesign of the stellar aspect camera is discussed along with developments in thin film fabrication.

Bowyer, S.↗

An 8-b 1.3-MHz successive-approximation A/D converter

A new successive-approximation A/D converter is described. It combines a string of equal-valued polysilicon resistors and a set of ratioed capacitors in a unique circuit configuration so that a high sampling rate is achieved. The comparator is realized by a chopper-stabilized amplifier to reduce the effect of the offset voltages of MOS amplifiers. The converter performs an 8-b monotonic conversion with a differential nonlinearity less than 1 LSB in 770 nsec. The die area is 3750 sq mil. This new conversion technique can also be utilized in a pipelined A/D converter (Temes, 1985) and enables it to achieve high speed.

Hadidi, KH.↗

A monolithic Si bolometer array for the Caltech Submillimeter Observatory

We are developing a submillimeter continuum camera for the Caltech Submillimeter Observatory (CSO) located on Mauna Kea. The camera will employ a monolithic Si bolometer array which was developed by Moseley et al. at the NASA Goddard Space Flight Center (GSFC). The camera will be cooled to a temperature of about 300 mK in a He-3 cryostat, and will operate primarily at wavelengths of 350 and 450 micrometers. We plan to use a bolometer array with 1x24 directly illuminated pixels, each pixel of dimension 1x2 sq mm, which is about half of the F/4 beam size at these wavelengths. Each pixel is 10 to 12 micrometers thick and is supported only by four thin Si legs formed by wet chemical etch. The pixels are doped n-type by phosphorus implantation, compensated by boron implantation. Signals from the bolometer pixels are first amplified by cryogenically cooled FET's. The signals are further amplified by room-temperature amplifiers and then separately digitized by 16 bit A/D converters with differential inputs. The outputs of the A/D converters are fed into a digital signal processing board via fiber-optic cables. The electronics and data acquisition system were designed by the Goddard group. We will report the status of this effort.

Wang, Ning↗

Effects of high glucose on mesenchymal stem cell proliferation and differentiation

High glucose (HG) concentrations impair cellular functions and induce apoptosis. Exposition of mesenchymal stem cells (MSC) to HG was reported to reduce colony forming activity and induce premature senescence. We characterized the effects of HG on human MSC in vitro using telomerase-immortalized MSC (hMSC-TERT) and primary MSC (hMSC). HG (25 mM) enhanced hMSC-TERT proliferation in long-term studies in contrast to hMSC where proliferation was unchanged. Thioredoxin-interacting protein, which is involved in apoptosis regulation, was stimulated by glucose in hMSC-TERT. However, apoptosis was not influenced by HG in both cell types. MSC treatment with HG favored osteogenic differentiation. MSC are resistant to HG toxicity, depending on the stemness of MSC. Proliferation and osteogenic differentiation are stimulated by HG. Effects of HG on the transient amplifying compartment of MSC may differ from those in mature cells. Further research is needed to unravel the molecular mechanisms of HG resistance of MSC.

60 APPLIED LIFE SCIENCES↗

Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices

Here, we present the design and implementation of a measurement system that enables parallel drive and detection of small currents and voltages at numerous electrical contacts to a multi-terminal electrical device. This system, which we term a feedback lock-in, combines digital control-loop feedback with software-defined lock-in measurements to dynamically source currents and measure small, pre-amplified potentials. The effective input impedance of each current/voltage probe can be set via software, permitting any given contact to behave as an open-circuit voltage lead or as a virtually grounded current source/sink. This enables programmatic switching of measurement configurations and permits measurement of currents at multiple drain contacts without the use of current preamplifiers. Our 32-channel implementation relies on commercially available digital input/output boards, home-built voltage preamplifiers, and custom open-source software. With our feedback lock-in, we demonstrate differential measurement sensitivity comparable to a widely used commercially available lock-in amplifier and perform efficient multi-terminal electrical transport measurements on twisted bilayer graphene and SrTiO 3 quantum point contacts. The feedback lock-in also enables a new style of measurement using multiple current probes, which we demonstrate on a ballistic graphene device.

47 OTHER INSTRUMENTATION↗