Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SU-E-J-100: The Combination of Deformable Image Registration and Regions-Of-Interest Mapping Technique to Accomplish Accurate Dose Calculation On Cone Beam Computed Tomography for Esophageal Cancer

Purpose: We introduce a new method combined with the deformable image registration (DIR) and regions-of-interest mapping (ROIM) technique to accurately calculate dose on daily CBCT for esophageal cancer. Methods: Patients suffered from esophageal cancer were enrolled in the study. Prescription was set to 66 Gy/30 F and 54 Gy/30 F to the primary tumor (PTV66) and subclinical disease (PTV54) . Planning CT (pCT) were segmented into 8 substructures in terms of their differences in physical density, such as gross target volume (GTV), venae cava superior (SVC), aorta, heart, spinal cord, lung, muscle and bones. The pCT and its substructures were transferred to the MIM software to readout their mean HU values. Afterwards, a deformable planning CT to daily KV-CBCT image registration method was then utilized to acquire a new structure set on CBCT. The newly generated structures on CBCT were then transferred back to the treatment planning system (TPS) and its HU information were overridden manually with mean HU values obtained from pCT. Finally, the treatment plan was projected onto the CBCT images with the same beam arrangements and monitor units (MUs) to accomplish dose calculation. Planning target volume (PTV) and organs at risk (OARs) from both of the pCT and CBCT were compared to evaluate the dose calculation accuracy. Results: It was found that the dose distribution in the CBCT showed little differences compared to the pCT, regardless of whether PTV or OARs were concerned. Specifically, dose variation in GTV, PTV54, PTV66, SVC, lung and heart were within 0.1%. The maximum dose variation was presented in the spinal cord, which was up to 2.7% dose difference. Conclusion: The proposed method combined with DIR and ROIM technique to accurately calculate dose distribution on CBCT for esophageal cancer is feasible.

60 APPLIED LIFE SCIENCES↗

SU-E-J-103: Propagation of Rectum and Bladder Contours for Tandem and Ring (T&R) HDR Treatment Using Deformable Image Registration

Purpose: To investigate the feasibility of using DIR to propagate the manually contoured rectum and bladder from the 1st insertion to the new CT images on subsequent insertions and evaluate the segmentation performance. Methods: Ten cervical cancer patients, who were treated by T&R brachytherapy in 3–4 insertions, were retrospectively collected. In each insertion, rectum and bladder were manually delineated on the planning CT by a physicist and verified by a radiation oncologist. Using VelocityAI (Velocity Medical Solutions, Atlanta, GA), a rigid registration was firstly employed to match the bony structures between the first insertion and each of the following insertions, then a multi-pass B-spine DIR was carried out to further map the sub volume that encompasses rectum and bladder. The resultant deformation fields propagated contours, and dice similarity coefficient (DSC) was used to quantitatively evaluate the agreement between the propagated contours and the manually-delineated organs. For the 3rd insertion, we also evaluated if the segmentation performance could be improved by propagating the contours from the most recent insertion, i.e., the 2nd insertion. Results: On average, the contour propagation took about 1 minute. The average and standard deviation of DSC over all insertions and patients was 0.67±0.10 (range: 0.44–0.81) for rectum, and 0.78±0.07 (range: 0.63–0.87) for bladder. For the 3rd insertion, propagating contours from the 2nd insertion could improve the segmentation performance in terms of DSC from 0.63±0.10 to 0.72±0.08 for rectum, and from 0.77±0.07 to 0.79±0.06 for bladder. A Wilcoxon signed rank test indicated that the improvement was statistically significant for rectum (p = 0.004). Conclusion: The preliminary results demonstrate that deformable image registration could efficiently and accurately propagate rectum and bladder contours between CT images in different T&R brachytherapy fractions. We are incorporating the propagated contours into our learning-based method to further segment these organs.

60 APPLIED LIFE SCIENCES↗

SU-E-J-106: The Use of Deformable Image Registration with Cone-Beam CT for a Better Evaluation of Cumulative Dose to Organs

Purpose: The knowledge of dose accumulation in the patient tissues in radiotherapy helps in determining the treatment outcomes. This project aims at providing a workflow to map cumulative doses that takes into account interfraction organ motion without the need for manual re-contouring. Methods: Five prostate cancer patients were studied. Each patient had a planning CT (pCT) and 5 to 13 CBCT scans. On each series, a physician contoured the prostate, rectum, bladder, seminal vesicles and the intestine. First, a deformable image registration (DIR) of the pCTs onto the daily CBCTs yielded registered CTs (rCT) . This rCT combined the accurate CT numbers of the pCT with the daily anatomy of the CBCT. Second, the original plans (220 cGy per fraction for 25 fractions) were copied on the rCT for dose re-calculation. Third, the DIR software Elastix was used to find the inverse transform from the rCT to the pCT. This transformation was then applied to the rCT dose grid to map the dose voxels back to their pCT location. Finally, the sum of these deformed dose grids for each patient was applied on the pCT to calculate the actual dose delivered to organs. Results: The discrepancy between the planned D98 and D2 and these indices re-calculated on the rCT, are, on average, of −1 ± 1 cGy and 1 ± 2 cGy per fraction, respectively. For fractions with large anatomical motion, the D98 discrepancy on the re-calculated dose grid mapped onto the pCT can raise to −17 ± 4 cGy. The obtained cumulative dose distributions illustrate the same behavior. Conclusion: This approach allowed the evaluation of cumulative doses to organs with the help of uncontoured daily CBCT scans. With this workflow, the easy evaluation of doses delivered for EBRT treatments could ultimately lead to a better follow-up of prostate cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-01: How Effective Is Abdominal Compression at Reducing Lung Motion? An Analysis Using Deformable Image Registration Within Different Sub-Regions of the Lung

Purpose: To investigate the effectiveness of employing abdominal compression (AC) in reducing motion for the target region and sub-regions of the lung as part of the planning process for radiation therapy. Methods: Fourteen patients with early lung cancer were scanned with 4DCT and it was determined that target motion exceeded our institutional limit of > 8 mm motion and received a repeat 4DCT with AC. For each 4DCT, deformable image registration (DIR) was used to map the max inhale to the max exhale phase to determine the deformation vector fields (DVF). DIR was performed with Morphons and Demons algorithms. The mean DVF was used to represent that sub-region for each patient. The magnitudes of the mean DVF were quantified for the target and 12 sub-regions in the AP, LR SI directions. The sub-regions were contoured on each lung as (add prefix R or L for lung): Upper-Anterior (UA), Upper-Posterior (UP), Mid-Anterior (MA), Mid-Posterior (MP), Lower-Anterior (LA) and Lower-Posterior (LP). Results: The min/max SI motion for the target on the uncompressed 4DCT was 8mm/24.5 mm. The magnitude of decrease in SI was greatest in the RLP region (3.7±4.0mm) followed by target region (3.3±2.2mm) and finally the LLP region (3.0±3.5mm). The magnitude of decrease in 3D vector followed the same trend; RLP (3.5±2.2mm) then GTV (3.5±2.6mm) then LLP (2.7±3.8mm). 79% of the cases had a SI decrease of >12.5%, 43% had a SI decrease of >25% and 21% had a SI decrease of >50% as compared to the motion on the uncompressed 4DCT. Conclusion: AC is useful in reducing motion with the largest decreases observed in the lower posterior regions of the lungs. However, it should be noted that AC will not greatly decrease motion for all cases as 21% of cases did not reduce SI motion more than 12.5% of initial motion.

60 APPLIED LIFE SCIENCES↗

Technical Note: Multipurpose CT, ultrasound, and MRI breast phantom for use in radiotherapy and minimally invasive interventions

Purpose: To develop a multipurpose gel-based breast phantom consisting of a simulated tumor with realistic imaging properties in CT, ultrasound and MRI, or a postsurgical cavity on CT. Applications for the phantom include: deformable image registration (DIR) quality assurance (QA), autosegmentation validation, and localization testing and training for minimally invasive image-guided procedures such as those involving catheter or needle insertion. Methods: A thermoplastic mask of a typical breast patient lying supine was generated and then filled to make an array of phantoms. The background simulated breast tissue consisted of 32.4 g each of ballistic gelatin (BG) powder and Metamusil™ (MM) dissolved in 800 ml of water. Simulated tumors were added using the following recipe: 12 g of barium sulfate (1.4% v/v) plus 0.000 14 g copper sulfate plus 0.7 g of MM plus 7.2 g of BG all dissolved in 75 ml of water. The phantom was evaluated quantitatively in CT by comparing Hounsfield units (HUs) with actual breast tissue. For ultrasound and MRI, the phantoms were assessed based on subjective image quality and signal-difference to noise (SDNR) ratio, respectively. The stiffness of the phantom was evaluated based on ultrasound elastography measurements to yield an average Young’s modulus. In addition, subjective tactile assessment of phantom was performed under needle insertion. Results: The simulated breast tissue had a mean background value of 24 HU on CT imaging, which more closely resembles fibroglandular tissue (40 HU) as opposed to adipose (−100 HU). The tumor had a mean CT number of 45 HU, which yielded a qualitatively realistic image contrast relative to the background either as an intact tumor or postsurgical cavity. The tumor appeared qualitatively realistic on ultrasound images, exhibiting hypoechoic characteristics compared to background. On MRI, the tumor exhibited a SDNR of 3.7. The average Young’s modulus was computed to be 15.8 ± 0.7 kPa (1 SD). Conclusions: We have developed a process to efficiently and inexpensively produce multipurpose breast phantoms containing simulated tumors visible on CT, ultrasound, and MRI. The phantoms have been evaluated for image quality and elasticity and can serve as a medium for DIR QA, autosegmentation QA, and training for minimally invasive procedures.

60 APPLIED LIFE SCIENCES↗

SU-F-J-173: Online Replanning for Dose Painting Based On Changing ADC Map of Pancreas Cancer

Purpose: The introduction of MR-guided radiation therapy (RT), e.g., MR-Linac, would allow dose painting to adapt spatial RT response revealed from MRI data during the RT delivery. The purpose of this study is to investigate the use of an online replanning method to adapt dose painting from the MRI Apparent Diffusion Coefficient (ADC) map acquired during the delivery of RT for pancreatic cancers. Methods: Original dose painting plans were created based on multi-parametric simulation MRI including T1, T2 and ADC, using a treatment planning system (MONACO, Elekta) equipped with an online replanning algorithm (WSO, warm start optimization). Multiple GTVs, identified based on various ADC levels were prescribed to different doses ranging from 50–70 Gy with simultaneous integrated boost in 28 fractions. The MRI acquired after RT were used to mimic weekly MRI, on which the changing GTVs, pancreatic head and other organs-at-risk (OAR) (duodenum, stomach, small bowel) were delineated. The adaptive plan was generated by applying WSO algorithm starting from the deformed original plan based on the weekly MRI using a deformable image registration (DIR) software (ADMIRE, Elekta). The online replanning method takes <10 min. including DIR, target delineation, WSO execution and final dose calculation. Standard IGRT repositioning and full-blown reoptimization plans were also generated to compare with the adaptive plans. Results: The online replanning method significantly improved the multiple target coverages and OAR sparing for pancreatic cancers. For example, for a case with two GTVs with prescriptions of 60 and 70 Gy in pancreatic head, V100-GTV70 (the volume covered by 100% of prescription dose for GTV with 70 Gy)/V100-GTV60/V100-CTV50/V45-duodenum were (95.1/22.2/69.5/85.7), (95.0/97.0/98.6/34.3), and (95.0/98.1/100.0/38.7) for the IGRT, adaptive and reoptimization plans, respectively. Conclusion: The introduced online adaptive replanning method can effectively account for interfractional changes including tumor spatial response during MR-guided RT delivery, allowing precise delivery of dose painting. This study was partially supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-J-217: Accurate Dose Volume Parameters Calculation for Revealing Rectum Dose-Toxicity Effect Using Deformable Registration in Cervical Cancer Brachytherapy: A Pilot Study

Purpose: To study the feasibility of employing deformable registration methods for accurate rectum dose volume parameters calculation and their potentials in revealing rectum dose-toxicity between complication and non-complication cervical cancer patients with brachytherapy treatment. Method and Materials: Data from 60 patients treated with BT including planning images, treatment plans, and follow-up clinical exam were retrospectively collected. Among them, 12 patients complained about hematochezia were further examined with colonoscopy and scored as Grade 1–3 complication (CP). Meanwhile, another 12 non-complication (NCP) patients were selected as a reference group. To seek for potential gains in rectum toxicity prediction when fractional anatomical deformations are account for, the rectum dose volume parameters D0.1/1/2cc of the selected patients were retrospectively computed by three different approaches: the simple “worstcase scenario” (WS) addition method, an intensity-based deformable image registration (DIR) algorithm-Demons, and a more accurate, recent developed local topology preserved non-rigid point matching algorithm (TOP). Statistical significance of the differences between rectum doses of the CP group and the NCP group were tested by a two-tailed t-test and results were considered to be statistically significant if p < 0.05. Results: For the D0.1cc, no statistical differences are found between the CP and NCP group in all three methods. For the D1cc, dose difference is not detected by the WS method, however, statistical differences between the two groups are observed by both Demons and TOP, and more evident in TOP. For the D2cc, the CP and NCP cases are statistically significance of the difference for all three methods but more pronounced with TOP. Conclusion: In this study, we calculated the rectum D0.1/1/2cc by simple WS addition and two DIR methods and seek for gains in rectum toxicity prediction. The results favor the claim that accurate dose deformation and summation tend to be more sensitive in unveiling the dose-toxicity relationship. This work is supported in part by grant from VARIAN MEDICAL SYSTEMS INC, the National Natural Science Foundation of China (no 81428019 and no 81301940), the Guangdong Natural Science Foundation (2015A030313302)and the 2015 Pearl River S&T Nova Program of Guangzhou (201506010096).

60 APPLIED LIFE SCIENCES↗

SU-F-T-680: Radiobiological Analysis of the Impact of Daily Patient Deformation and Setup Variations Through the Use of the Cone Beam CT and Deformable Image Registration in Lung Cancer IMRT

Purpose: To estimate the dose distributions delivered to the patient in each treatment fraction using deformable image registration (DIR) and assess the radiobiological impact of the inter-fraction variations due to patient deformation and setup. Methods: The work is based on the cone beam CT (CBCT) images and treatment plans of two lung cancer patients. Both patients were treated with intensity modulated radiation therapy (IMRT) to 66Gy in 2Gy/fraction. The treatment plans were exported from the treatment planning system (TPS) to the Velocity AI where DIR was performed and the same deformation matrix was used for the deformation of the planned dose distribution and organ contours to each CBCT dataset. A radiobiological analysis was performed based on the radiobiological parameters of the involved organs at risk (OARs) and planning target volume (PTV). Using the complication free tumor control probability (P+) index, differences in P+ were observed between each CBCT as well as between CBCT and planning dose distributions. Results: The optimal CBCT P? values ranged from 91.6 % to 94.8 % for patient #1 and from 88.8 % to 90.6 % for patient #2. At the dose level of the clinical prescription, the CBCT P+ values ranged from 80.3% to 80.7% for patient #1 and from 80.7% to 81.0% for the patient #2. The planning CT P+ values were 81.0% and 80.7% for the two patients, respectively. These differences emphasize the significance of using the radiobiological analysis when assessing changes in the dose distribution due to the tumor motion and lung deformations. Conclusion: Daily setup variations yield to differences in the actual dose delivered versus the planned one. The observed differences were rather small when only looking at the dosimetric comparison of the dose distributions, however the radiobiology analysis was able to detect clinically relevant differences among the studied dose distributions.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-06: Fast GPU Framework for Four-Dimensional Monte Carlo in Adaptive Intensity Modulated Proton Therapy (IMPT) for Mobile Tumors

Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) treatment planning and verification using four-dimensional CT (4DCT) for adaptive IMPT for lung cancer patients. Methods: A validated GPU MC code, gPMC, has been linked to the patient database at our institution and employed to compute the dose-influence matrices (Dij) on the planning CT (pCT). The pCT is an average of the respiratory motion of the patient. The Dijs and patient structures were fed to the optimizer to calculate a treatment plan. To validate the plan against motion, a 4D dose distribution averaged over the possible starting phases is calculated using the 4DCT and a model of the time structure of the delivered spot map. The dose is accumulated using vector maps created by a GPU-accelerated deformable image registration program (DIR) from each phase of the 4DCT to the reference phase using the B-spline method. Calculation of the Dij matrices and the DIR are performed on a cluster, with each field and vector map calculated in parallel. Results: The Dij production takes ∼3.5s per beamlet for 10e6 protons, depending on the energy and the CT size. Generating a plan with 4D simulation of 1000 spots in 4 fields takes approximately 1h. To test the framework, IMPT plans for 10 lung cancer patients were generated for validation. Differences between the planned and the delivered dose of 19% in dose to some organs at risk and 1.4/21.1% in target mean dose/homogeneity with respect to the plan were observed, suggesting potential for improvement if adaptation is considered. Conclusion: A fast MC treatment planning framework has been developed that allows reliable plan design and verification for mobile targets and adaptation of treatment plans. This will significantly impact treatments for lung tumors, as 4D-MC dose calculations can now become part of planning strategies.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-06: Evaluation of Registration Accuracy for Cone-Beam CT Reconstruction Techniques

Purpose: Cone-beam (CB) computed tomography (CT) is used for image guidance during radiotherapy treatment delivery. Conventional Feldkamp and compressed sensing (CS) based CBCT recon-struction techniques are compared for image registration. This study is to evaluate the image registration accuracy of conventional and CS CBCT for head-and-neck (HN) patients. Methods: Ten HN patients with oropharyngeal tumors were retrospectively selected. Each HN patient had one planning CT (CTP) and three CBCTs were acquired during an adaptive radiotherapy proto-col. Each CBCT was reconstructed by both the conventional (CBCTCON) and compressed sens-ing (CBCTCS) methods. Two oncologists manually labeled 23 landmarks of normal tissue and implanted gold markers on both the CTP and CBCTCON. Subsequently, landmarks on CTp were propagated to CBCTs, using a b-spline-based deformable image registration (DIR) and rigid registration (RR). The errors of these registration methods between two CBCT methods were calcu-lated. Results: For DIR, the mean distance between the propagated and the labeled landmarks was 2.8 mm ± 0.52 for CBCTCS, and 3.5 mm ± 0.75 for CBCTCON. For RR, the mean distance between the propagated and the labeled landmarks was 6.8 mm ± 0.92 for CBCTCS, and 8.7 mm ± 0.95 CBCTCON. Conclusion: This study has demonstrated that CS CBCT is more accurate than conventional CBCT in image registration by both rigid and non-rigid methods. It is potentially suggested that CS CBCT is an improved image modality for image guided adaptive applications.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-12: Use of Cone Beam CT and Deformable Image Registration for Assessing Geometrical and Dosimetric Variations During Lung Radiotherapy

Purpose: To assess the value of cone beam CT (CBCT) combined with deformable image registration in estimating the accuracy of the delivered treatment and the suitability of the applied target margins. Methods: Two patients with lung tumor were selected. Using their CT images intensity modulated radiation therapy (IMRT) treatment plans were developed to deliver 66Gy to the 95% of the PTV in 2Gy fractions. Using the Velocity AI software, the planning CT of each patient was registered with the fractional CBCT images that were obtained through the course of the treatment. After a CT to CBCT deformable image registration (DIR), the same fractional deformation matrix was used for the deformation of the planned dose distributions, as well as of all the contoured volumes, to each CBCT dataset. The dosimetric differences between the planning target volume (PTV) and various organs at risk (OARs) were recorded and compared. Results: CBCT data such as CTV volume change and PTV coverage was analyzed. There was a moderate relationship between volume changes and contouring method (automatic contouring using the DIR transformation vs. manual contouring on each CBCT) for patient #1 (r = 0.49), and a strong relationship for patient #2 (r = 0.83). The average PTV volume coverage from all the CBCT datasets was 91.2% for patient #1 and 95.6% for patient #2. Conclusion: Daily setup variations, tumor volume motion and lung deformation due to breathing yield differences in the actual delivered dose distributions versus the planned ones. The results presented indicate that these differences are apparent even with the use of daily IGRT. In certain fractions, the margins used seem to be insufficient to ensure acceptable lung tumor coverage. The observed differences notably depend on the tumor volume size and location. A larger cohort of patient is under investigation to verify those findings.

60 APPLIED LIFE SCIENCES↗

WE-AB-202-05: Validation of Lung Stress Maps for CT-Ventilation Imaging

Purpose: To date, lung CT-ventilation imaging has been based on quantification of local breathing-induced changes in Hounsfield Units (HU) or volume. This work investigates the use of a stress map resulting from a biomechanical deformable image registration (DIR) algorithm as a metric of the ventilation function. Method: Eight lung cancer patients presenting different kinds of ventilation defects were retrospectively analyzed. Additionally, to the 4DCT acquired for radiotherapy planning, five of them had PET and three had SPECT imaging following inhalation of Ga-68 and Tc-99m, respectively. For each patient, the inhale phase of the 4DCT was registered to the exhale phase using Morfeus, a biomechanical DIR algorithm based on the determination of boundary conditions on the lung surfaces and vessel tree. To take into account the heterogeneity of the tissue stiffness in the stress map estimation, each tetrahedral element of the finite-element model was assigned a Young’s modulus ranging from 60kPa to 12MPa, as a function of the HU in the inhale CT. The node displacements and element stresses resulting from the numerical simulation were used to generate three CT-ventilation maps based on: (i) volume changes (Jacobian determinant), (ii) changes in HU, (iii) the maximum principal stress. The voxel-wise correlation between each CT-ventilation map and the PET or SPECT V image was computed in a lung mask. Results: For patients with PET, the mean (min-max) Spearman correlation coefficients r were: 0.33 (0.19–0.45), 0.36 (0.16–0.51) and 0.42 (0.21–0.59) considering the Jacobian, changes in HU and maximum principal stress, respectively. For patients with SPECT V, the mean r were: 0.12 (−0.12–0.43), 0.29 (0.22–0.45) and 0.33 (0.25–0.39). Conclusion: The maximum principal stress maps showed a stronger correlation with the ventilation images than the previously proposed Jacobian or change in HU maps. This metric thus appears promising for CT-ventilation imaging. This work was funded in part by NIH P01CA059827.

60 APPLIED LIFE SCIENCES↗

Sci-Fri AM: MRI and Diagnostic Imaging - 02: Quality Improvement: Diagnostic Reference Levels for Interior Health CT exams – L-Spine, Chest/Abdomen/pelvis, Abdomen/Pelvis, Head

Diagnostic Reference Levels are used to optimize patient dose and image quality in the clinical setting. It is assumed that the majority of exams are of diagnostic quality, or the radiologists would request protocol adjustments. By investigating the dose indicator distributions from all scanners, the upper DRL can be set to the 75th percentile of the distribution and a lower DRL can be set to the 10th percentile. Scanners using doses consistently outside the upper/lower DRL range can be adjusted accordingly. 11 CT scanners, all contributing to the American College of Radiology Dose Index Registry (ACR DIR) were used in this study. Dose indicator data were compiled from the ACR DIR data and local DRLs established. Scanners with median doses outside the upper/lower DRL were followed-up with. Using effective dose and exam volumes, collective dose was determined before and after protocol adjustments to evaluate the effect of this quality improvement effort. The quality initiative is complete for L-spine and Chest/Abdomen/Pelvis exams and only initial surveys were completed for Head and Abdomen/Pelvis examsg. Median Scanner Dose reductions were 8.8 and 4.9 % for L-spine and Chest/Abdomen/Pelvis exams, respectively, resulting with collective dose reductions of 0.7 and 3.2 person•Sv/yr. Follow-up is ongoing for Abdomen/Pelvis and Head exams.

60 APPLIED LIFE SCIENCES↗

Dataset for "Evaluating Deep Learning Approaches for Predictions in Unmonitored Basins with Continental-scale Stream Temperature Models" Willard et al. (2024)

This data release provides all data and code used in the paper " "Evaluating Deep Learning Approaches for Predictions in Unmonitored Basins with Continental-scale Stream Temperature Models" Willard et al. (2024)" to model stream temperature, evaluate, and assess results. The associated manuscript explores current open questions in prediction in ungauged and unmonitored basins concerning top-down versus bottom-up approaches, tradeoffs between data available and input requirements, and the appropriate representation of catchment attributes as inputs to deep learning models. Modeling was done primarily with long short-term memory (LSTM) models, and stream site coverage spans 1362 locations across the conterminous United States. The data is organized into these items items:Code repository and data for the paper " "Evaluating Deep Learning Approaches for Predictions in Unmonitored Basins with Continental-scale Stream Temperature Models" Willard et al. (2024)".Code: stream_temp_ml_regionalization.zip contains the code repositoryData to run the code: - data_dir.zip -- contains all files that should be moved to the "DATA_DIR" variable defined in the "set_env_vars.sh" script in the code repository- metadata_dir.zip -- contains all files that should be moved to the "METADATA_DIR" variable defined in the "set_env_vars.sh" script in the code repository- error_analysis_attribute_and_groundwater_dir.zip - workflows for the extended error analysis by stream attribute and groundwater influenceData produced by the code and used in the paper:- outputs_dir.zip - contains model output and results (outputs_dir/results), model weights (outputs_dir/models), and all other outputs used for the paper including feature importances.To cite this code, please use the following BibTeX or MLA entries:bibtex:@misc{willard2024streamdata, author = {Jared Willard and Fabio Ciulla and Helen Weierbach and Vipin Kumar and Charuleka Varadharajan}, title = {Dataset for "Evaluating Deep Learning Approaches for Predictions in Unmonitored Basins with Continental-scale Stream Temperature Models"}, year = {2024}, doi = {10.15485/2448016}, publisher = {ESS-DIVE Repository}, url = {https://doi.org/10.15485/2448016}}MLA: Willard, Jared, et al. Dataset for "Evaluating Deep Learning Approaches for Predictions in Unmonitored Basins with Continental-scale Stream Temperature Models". 2024. ESS-DIVE Repository, doi:10.15485/2448016.

54 ENVIRONMENTAL SCIENCES↗

Dataset for "Machine Learning Ensembles Can Enhance Hydrologic Predictions and Uncertainty Quantification" Willard et al. (2025).

This data release provides all data and code used in the paper " "Machine Learning Ensembles Can Enhance Hydrologic Predictions and Uncertainty Quantifications" Willard et al. (2025)" to model stream temperature, evaluate, and assess results. The associated manuscript explores the effect of different ensemble construction techniques across different common machine learning (ML) architectures for predictions in unmonitored basins. Modeling was done using long short-term memory (LSTM), gated recurrent unit (GRU), temporal convolution network (TCN), and extreme gradient boosting (XGBoost) models, and stream site coverage spans 1362 locations across the conterminous United States. The ensemble construction techniques investigated include ensemble by random weight initialization, differing hyperparameters, different random subsets of training data, different subselections of input features, different architectures, and Monte Carlo Dropout. The data is organized into these items items:Code repository and data for the paper " "Machine Learning Ensembles Can Enhance Hydrologic Predictions and Uncertainty Quantifications" Willard et al. (2025).Code: stream_temp_ml_regionalization.zip contains the code repositoryData to run the code:- data_dir.zip -- contains all files that should be moved to the "DATA_DIR" variable defined in the "set_env_vars.sh" script in the code repository- metadata_dir.zip -- contains all files that should be moved to the "METADATA_DIR" variable defined in the "set_env_vars.sh" script in the code repositoryData produced by the code and used in the paper:- outputs_dir.zip - contains model output and results (outputs_dir/results), model weights (outputs_dir/models), and all other outputs used for the paper including feature importances.To cite this code, please use the following BibTeX or MLA entries:bibtex:@misc{willard2025streamensembles,author = {Jared Willard and Charuleka Varadharajan},title = {Dataset for "Machine Learning Ensembles Can Enhance Hydrologic Predictions and Uncertainty Quantification"},year = {2024},doi = {10.15485/2527393},publisher = {ESS-DIVE Repository},url = {https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2527393}}MLA: Willard, Jared, et al. Dataset for "Machine Learning Ensembles Can Enhance Hydrologic Predictions and Uncertainty Quantification". 2025. ESS-DIVE Repository, doi:10.15485/2448016.

54 ENVIRONMENTAL SCIENCES↗

Approach to Startup Inventory for Viable Commercial Power Plant

Summary • FPP realization within the next 10-15 years will require dedicated efforts to improve DIR, burn fraction, fueling efficiency, and/or processing times. • Modest improvements from either the fuel cycle side or plasma physics side should be possible with considered allocation of R&D funding. • Current gaps in particular include blanket extraction at scale, improved efficiency in isotope separation and detritiation, and maximizing DIR efficiency. • Total costs for FPP construction and commissioning depend heavily on site regulation, so decreases in required SI and OI can lead to large decreases in capital outlay. • Some subsystems in the fuel cycle are required from a environmental management perspective but are both energetically expensive and time consuming, particularly water detritiation. • Low inventories but high capital and operational costs mean a centralized water detritiation plant could greatly improve likelihood of deployment of multiple FPPs on the same time scale.

MALONE, COLLIN↗

Global Energetics of Solar Flares. V. Energy Closure in Flares and Coronal Mass Ejections

In this study we synthesize the results of four previous studies on the global energetics of solar flares and associated coronal mass ejections (CMEs), which include magnetic, thermal, nonthermal, and CME energies in 399 solar M- and X-class flare events observed during the first 3.5 yr of the Solar Dynamics Observatory (SDO) mission. Our findings are as follows. (1) The sum of the mean nonthermal energy of flare-accelerated particles (E{sub nt}), the energy of direct heating (E{sub dir}), and the energy in CMEs (E{sub CME}), which are the primary energy dissipation processes in a flare, is found to have a ratio of (E{sub nt}+E{sub dir}+E{sub CME})/E{sub mag}=0.87±0.18, compared with the dissipated magnetic free energy E{sub mag}, which confirms energy closure within the measurement uncertainties and corroborates the magnetic origin of flares and CMEs. (2) The energy partition of the dissipated magnetic free energy is: 0.51 ± 0.17 in nonthermal energy of ⩾6 keV electrons, 0.17 ± 0.17 in nonthermal ⩾1 MeV ions, 0.07 ± 0.14 in CMEs, and 0.07 ± 0.17 in direct heating. (3) The thermal energy is almost always less than the nonthermal energy, which is consistent with the thick-target model. (4) The bolometric luminosity in white-light flares is comparable to the thermal energy in soft X-rays (SXR). (5) Solar energetic particle events carry a fraction ≈0.03 of the CME energy, which is consistent with CME-driven shock acceleration. (6) The warm-target model predicts a lower limit of the low-energy cutoff at e{sub c}≈6 keV, based on the mean peak temperature of the differential emission measure of T {sub e} = 8.6 MK during flares. This work represents the first statistical study that establishes energy closure in solar flare/CME events.

79 ASTRONOMY AND ASTROPHYSICS↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗