Search NASASearch

SEARCH · Search NASA

Results for “DOSAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Low-intensity x-ray and gamma-ray imaging device

Low-dosage, low-power X-ray system can be made completely self-contained, allowing fluoroscopy and radiography to be carried out in field and remote locations. New device, known as "lixiscope," can be used with conventional X-ray machine turned down to low level, or, it can be operated with radioisotope source for hand-held portable applications. Originally developed for X-ray astronomy, lixiscope obtains high sensitivity by using intermediate stages of photoelectron conversion and electron amplification to generate image suitable for direct viewing or for recording on film.

Yin, L. I.

Provisional standards of radiation safety during flights

Radiation effects during space flights are discussed in the context of the sources and dangers of such radiation and the radiobiological prerequisites for establishing safe levels of radiation dosage. Standard safe levels of radiation during space flight are established.

Source record

Radiolysis, racemization and the origin of molecular asymmetry in the biosphere

An investigation has been undertaken to determine whether ionizing radiation might engender racemization of optically active amino acids, along with their usual radiolysis. As prototypes, crystalline Dand L-leucine, as well as aqueous solutions of their sodium salts were exposed to the radiation from a 3000 Ci Co-60 gamma-ray source. Gamma-ray doses which caused about 68% radiolysis of solid leucine left a residue which was about 5% racemized, while racemization proved even greater at lower doses for the dissolved sodium salts. In aqueous solution both percent degradation and percent racemization of the sodium salts were proportional to gamma-ray dosage within the range employed (1,000,000-27,000,000 rads). Implications of these observations for the origin of molecular asymmetry by the beta-decay parity violation mechanism are discussed.

Bonner, W. A.

Improvements to the single screw extruder

The extrusion on a single screw extruder is examined. The process is divided into several steps: the dosage of the materials to be conveyed; the modification of the shape of the feeding opening which influences the feeding process and consequently the throughput of the extruder; optimizing the shape of the feeding zone to meet the specific material requirements; and plasticizing and homogenizing.

Hiemenz, C.

CO2 laser annealing of 50-microns-thick silicon solar cells

A test program is conducted to determine thin solar cell annealing effects using a laser energy source. A CO2 continuous-wave laser was used in annealing experiments on 50 micrometers-thick silicon solar cells after proton irradiation. Test cells were irradiated to a fluence of 1.0 x 10 to the 12th power protons/sq cm with 1.9 MeV protons. After irradiation, those cells receiving full proton dosage were degraded by an average of 30% in output power. In annealing tests laser beam exposure times on the solar cell varied from 2 seconds to 16 seconds reaching cell temperatures of from 400 C to 500 C. Under those conditions annealing test results showed recovery in cell output power of from 33% to 90%.

Walker, F. E.

Proton-induced coloring of multicomponent glasses

The paper describes the coloring induced by 85-MeV protons in three Schott glasses representative of glass types used as focusing elements in the International Ultraviolet Explorer Fine Error Sensor. It is shown that the absorption (i.e., coloring) induced in each glass by the radiation can be resolved into three optical absorption bands in the near UV-visible range. It is also discussed how that absorption grows with increasing dosages of protons, thus providing the means to predict degradation in any of the three glasses for a particular fluence of proton radiation.

Bartusiak, M. F.

Dosimetric considerations in dental applications

The integration of the Lixiscope into dental procedures was studied and compared with conventional dental radiographic techniques. It was found that through the use of intraoral sealed sources in conjunction with microchannel plate technology, the Lixiscope gives increased diagnostic information with decreased radiation dosage.

Goble, J. C.

Method for analyzing radiation sensitivity of integrated circuits

A method for analyzing the radiation sensitivity of an integrated circuit is described to determine the components. The application of a narrow radiation beam to portions of the circuit is considered. The circuit is operated under normal bias conditions during the application of radiation in a dosage that is likely to cause malfunction of at least some transistors, while the circuit is monitored for failure of the irradiated transistor. When a radiation sensitive transistor is found, then the radiation beam is further narrowed and, using a fresh integrated circuit, a very narrow beam is applied to different parts of the transistor, such as its junctions, to locate the points of greatest sensitivity.

Gauthier, M. K.

The ulcerogenic effect of bile and bile acid in rats during immobilization stress

The effect of different concentrations of oxen bile and individual bile acids or their sodium salts on the gastric mucosa of rats was investigated in combination with immobilization stress. A statistically significant higher frequency of ulcers was only determined in the application of 10% oxen bile. Dosages on 10% sodium glycocholic acid demonstrated strong toxic damage with atonic dilation of the stomach and extensive mucosal bleeding.

Weisener, J.

Solar-Terrestrial Predictions Proceedings. Volume 2: Working Group Reports and Reviews

Accurate models are needed to support research in the following areas: spacecraft charging, radiation dosage, transionospheric radio propagation, long and short term solar activity, magnetospheric disturbances, ionospheric interactions, solar weather/climate effects, and geomagnetic applications such as electric power transmission and oil and gas pipeline problems.

Richard F Donnelly

Relative toxicity testing of spacecraft materials. 1: Spacecraft materials

In chamber thermodegradation procedures were used to access the lethality to rats of the pyrolysis/combustion products of three foams, an adhesive backed metallic tape and RTV silicone rubber adhesive sealant used in spacecraft construction. The role of carbon monoxide in the overall pyrolysate toxicity was also investigated. Post exposure observation of the rats, histological evaluation of selected organs, carbon monoxide concentration in the chamber atmosphere during exposure and the percent carboxyhemoglobin in the animals expiring in the chamber are discussed. Thermogravimetric analysis and dosage response results are given. The lethal effect of the RTV silicon appears to be due to physical obstruction of the respiratory system by particulate matter from pyrolysis.

Lawrence, W. H.

Skylab: Cytogenetic studies of blood (experiment mill)

Preflight and postflight chromosomal analyses of space flight crews are presented. Special attention is given to findings suggestive of exposure to ionizing radiation. Information was obtained by study of persons receiving an external body source, such as, therapeutic dosage or those accidentally exposed. Others receiving radiation exposure from an internal source, such as the decay of radioisotopes administered for diagnosis or treatment, were also analyzed.

Lockhart, L. H.

Dispersion model studies for Space Shuttle environmental effects activities

The NASA/MSFC REED computer code was developed for predicting concentrations, dosage, and deposition downwind from rocket vehicle launches. The calculation procedures and results of nine studies using the code are presented. Topics include plume expansion, hydrazine concentrations, and hazard calculations for postulated fuel spills.

Source record

A new CT collimator for producing two simultaneous overlapping slices from one scan

A new CT collimator is developed which is capable of producing two simultaneous successive overlapping images from a single scan. The collimator represents a modification of the standard EMI 5005 collimator achieved by alternately masking one end or portions of both ends of the X-ray detectors at a 13-mm beamwidth so that a set of 540 filtered projections is obtained for each scan which can be separated into two sets of interleaved projections corresponding to views 3 mm apart. Tests have demonstrated that the quality of the images produced from these two projections almost equals the quality of those produced by the standard collimator from two separate scans. The new collimator may thus be used to achieve a speed improvement in the generation of overlapping sections as well as a reduction in X-ray dosage.

Kwoh, Y. S.

Secondary Electron Emission Yields

The secondary electron emission (SEE) characteristics for a variety of spacecraft materials were determined under UHV conditions using a commercial double pass CMA which permits sequential Auger electron electron spectroscopic analysis of the surface. The transparent conductive coating indium tin oxide (ITO) was examined on Kapton and borosilicate glass and indium oxide on FED Teflon. The total SEE coefficient ranges from 2.5 to 2.6 on as-received surfaces and from 1.5 to 1.6 on Ar(+) sputtered surfaces with 5 nm removed. A cylindrical sample carousel provides normal incidence of the primary beam as well as a multiple Faraday cup measurement of the approximately nA beam currents. Total and true secondary yields are obtained from target current measurements with biasing of the carousel. A primary beam pulsed mode to reduce electron beam dosage and minimize charging of insulating coatings was applied to Mg/F2 coated solar cell covers. Electron beam effects on ITO were found quite important at the current densities necessary to do Auger studies.

Krainsky, I.

Reeds computer code

The REEDS (rocket exhaust effluent diffusion single layer) computer code is used for the estimation of certain rocket exhaust effluent concentrations and dosages and their distributions near the Earth's surface following a rocket launch event. Output from REEDS is used in producing near real time air quality and environmental assessments of the effects of certain potentially harmful effluents, namely HCl, Al2O3, CO, and NO.

Bjork, C.

Oxygen impurity effects at metal/silicide interfaces - Formation of silicon oxide and suboxides in the Ni/Si system

The effect of implanted oxygen impurities on the Ni/Ni2Si interface is investigated using X-ray photoelectron spectroscopy, He-4(+) backscattering and O(d, alpha)-16 N-14 nuclear reactions. Oxygen dosages corresponding to concentrations of 1, 2, and 3 atomic percent were implanted into Ni films evaporated on Si substrates. The oxygen, nickel, and silicon core lines were monitored as a function of time during in situ growth of the Ni silicide to determine the chemical nature of the diffusion barrier which forms in the presence of oxygen impurities. Analysis of the Ni, Si, and O core levels demonstrates that the formation of SiO2 is responsible for the Ni diffusion barrier rather than Ni oxide or mixed oxides, such as Ni2SiO4. It is determined that 2.2 x 10 to the 16th O/qu cm is sufficient to prevent Ni diffusion under UHV annealing conditions.

Grunthaner, P. J.

Electron beam induced damage in ITO coated Kapton

Data for the stability of thin conductive indium tin oxide films on 0.003 inch thick Kapton substrates during exposure of the surface to electron beams are reported. The electron beam energy was 3 keV and the diameter was about 0.8 mm. Thermal effects and surface modifications are considered. For primary current greater than 0.6 microamperes, an obvious dark discoloration with diameter approximately that of the beam was produced. The structure of the discolored region was studied with the scanning electron microscope, and the findings are stated. Surface modifications were explored by AES, obtaining spectra and secondary emission coefficient as a function of time for different beam intensities. In all cases beam exposure results in a decrease of the secondary yield but because of thermal effects this change, as well as composition changes, cannot be directly interpreted in terms of electron beam dosage.

Krainsky, I.