Search NASASearch

SEARCH · Search NASA

Results for “DRY CELL BATTERY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

855 records · Page 9

NASA Battery Working Group - 2007-2008: Battery Task Summary Report

This presentation provides a summary of the 2007-2008 NASA Battery Working Group efforts completed in support of the NASA Engineering Safety Center (NESC). The effort covered a series of pro-active tasks that address the following: Binding Procurements -- guidelines related to requirements for the battery system that should be considered at the time of contract award Wet Life of Ni-H2 Batteries -- issues/strategies for effective storage and impact of long-term storage on performance and life Generic Guidelines for Lithium-ion Safety, Handling and Qualification -- Standardized approaches developed and risk assessments (1) Lithium-ion Performance Assessment -- survey of manufacturers and capabilities to meet mission needs. Guidelines document generated (2) Conditions Required for using Pouch Cells in Aerospace Missions -- focus on corrosion, thermal excursions and long-term performance issues. Document defining requirements to maintain performance and life (3) High Voltage Risk Assessment -- focus on safety and abuse tolerance of battery module assemblies. Recommendations of features required for safe implementation (4) Procedure for Determination of Safe Charge Rates -- evaluation of various cell chemistries and recommendation of safe operating regimes for specific cell designs

Manzo, Michelle

International Ultraviolet Explorer (IUE) Battery History and Performance

The "International Ultraviolet Explorer (IUE) Battery History and Performance" report provides the information on the cell/battery design, battery performance during the thirty eight (38) solar eclipse seasons and the end-of-life test data. It is noteworthy that IUE spacecraft was an in-house project and that the batteries were designed, fabricated and tested (Qualification and Acceptance) at the Goddard Space Flight Center. A detailed information is given on the cell and battery design criteria and the designs, on the Qualification and the Acceptance tests, and on the cell life cycling tests. The environmental, thermal, and vibration tests were performed on the batteries at the battery level as well as with the interface on the spacecraft. The telemetry data were acquired, analyzed, and trended for various parameters over the mission life. Rigorous and diligent battery management programs were developed and implemented from time to time to extend the mission life over eighteen plus years. Prior to the termination of spacecraft operation, special tests were conducted to check the battery switching operation, battery residual capacity, third electrode performance and battery impedance.

Rao, Gopalskrishna M.

Advanced nickel-hydrogen spacecraft battery development

Eagle-Picher currently has several advanced nickel-hydrogen (NiH2) cell component and battery designs under development including common pressure vessel (CPV), single pressure vessel (SPV), and dependent pressure vessel (DPV) designs. A CPV NiH2 battery, utilizing low-cost 64 mm (2.5 in.) cell diameter technology, has been designed and built for multiple smallsat programs, including the TUBSAT B spacecraft which is currently scheduled (24 Nov. 93) for launch aboard a Russian Proton rocket. An advanced 90 mm (3.5 in.) NiH2 cell design is currently being manufactured for the Space Station Freedom program. Prototype 254 mm (10 in.) diameter SPV batteries are currently under construction and initial boilerplate testing has shown excellent results. NiH2 cycle life testing is being continued at Eagle-Picher and IPV cells have currently completed more than 89,000 accelerated LEO cycles at 15% DOD, 49,000 real-time LEO cycles at 30 percent DOD, 37,800 cycles under a real-time LEO profile, 30 eclipse seasons in accelerated GEO, and 6 eclipse seasons in real-time GEO testing at 75 percent DOD maximum. Nickel-metal hydride battery development is continuing for both aerospace and electric vehicle applications. Eagle-Picher has also developed an extensive range of battery evaluation, test, and analysis (BETA) measurement and control equipment and software, based on Hewlett-Packard computerized data acquisition/control hardware.

Coates, Dwaine K.

Galileo Li/SO sub 2 battery modules program update

In order to meet the power needs of NASA's Galileo Probe, the Li/SO2 high rate D cells used in the battery modules have undergone some design changes, as upgrading of hardware quality requirements, and significant testing. A description of the design changes and the cell test data that are of a general nature is presented here. This data includes capacities, open circuit voltages, and internal resistance comparisons. A significant data base was built up over the years and continues to grow.

Smith, R. A.

Summary of LDEF battery analyses

Tests and analyses of NiCd, LiSO2, and LiCf batteries flown on the Long Duration Exposure Facility (LDEF) includes results from NASA, Aerospace, and commercial labs. The LiSO2 cells illustrate six-year degradation of internal components acceptable for space applications, with up to 85 percent battery capacity remaining on discharge of some returned cells. LiCf batteries completed their mission, but lost any remaining capacity due to internal degradation. Returned NiCd batteries tested an GSFC showed slight case distortion due to pressure build up, but were functioning as designed.

Johnson, Chris

Multikilowatt hydrogen-nickel oxide battery system

The potential of the H2-NiO battery for terrestrial applications was assessed. A multicell design approach that differs significantly from the aerospace individual pressure vessel was used. A number of experimental 100-Ah cells were built to evaluate the new design concepts and components. The experimental cells provided the input needed for a multicell battery design. It is found that new multicell H2-NiO battery has a number of potential advantages for aerospace applications such as the manned space station. The advantages are discussed, and a design concept is presented for a multikilowatt battery in a lightweight pressure vessel.

Dunlop, J. D.

Battery Fault Detection with Saturating Transformers

A battery monitoring system utilizes a plurality of transformers interconnected with a battery having a plurality of battery cells. Windings of the transformers are driven with an excitation waveform whereupon signals are responsively detected, which indicate a health of the battery. In one embodiment, excitation windings and sense windings are separately provided for the plurality of transformers such that the excitation waveform is applied to the excitation windings and the signals are detected on the sense windings. In one embodiment, the number of sense windings and/or excitation windings is varied to permit location of underperforming battery cells utilizing a peak voltage detector.

Davies, Francis J.

20V, 40 Ah Lithium Ion Polymer Battery for the Spacesuit

Objective: Consider a new battery design for EMU. Results: a) Electrovaya s aerospace cell production line is improving, but must further improve to achieve acceptable reliability; b) Completed functional, vibration, and thermal cycling of LIB; c) So far, electrical safety tests have produced good results; d) Completed functional, vibration, thermal cycling, power quality and EMI of LIB Charger; e) Completed CDR on 9/23/04; and f) Manufacturing Readiness Review for flight cell/battery production scheduled for Dec 04.

Darcy, Eric

Bipolar Nickel-Metal Hydride Battery Development Project

This paper reviews the development of the Electro Energy, Inc.'s bipolar nickel metal hydride battery. The advantages of the design are that each cell is individually sealed, and that there are no external cell terminals, no electrode current collectors, it is compatible with plastic bonded electrodes, adaptable to heat transfer fins, scalable to large area, capacity and high voltage. The design will allow for automated flexible manufacturing, improved energy and power density and lower cost. The development and testing of the battery's component are described. Graphic presentation of the results of many of the tests are included.

Cole, John H.

Summary of NASA Aerospace Flight Battery Systems Program activities

A summary of NASA Aerospace Flight Battery Systems Program Activities is presented. The NASA Aerospace Flight Battery Systems Program represents a unified NASA wide effort with the overall objective of providing NASA with the policy and posture which will increase the safety, performance, and reliability of space power systems. The specific objectives of the program are to: enhance cell/battery safety and reliability; maintain current battery technology; increase fundamental understanding of primary and secondary cells; provide a means to bring forth advanced technology for flight use; assist flight programs in minimizing battery technology related flight risks; and ensure that safe, reliable batteries are available for NASA's future missions.

Manzo, Michelle

Non-magnetic battery case Patent

Nonmagnetic hermetically sealed battery case made of epoxy resin and woven glass tape for use with electrochemical cells in spacecraft

Hennigan, T. J.

Battery Control Boards for Li-Ion Batteries on Mars Exploration Rovers

Rechargeable Lithium-ion batteries have been operating successfully on both Spirit and Opportunity rovers for the last two years, which includes six months of Assembly Launch and Test Operations (ATLO), seven months of cruise and about eleven months of surface operations. The Battery Control Boards designed and fabricated in-house would protect cells against overcharge and over-discharge and provide cell balance. Their performance has thus far been quite satisfactory. The ground data o the mission simulation battery project little capacity loss of less than 3% during cruise and 180 sols. Batteries are poised to extend the mission beyond six months, if not a couple of years.

Ewell, R.

A high reliability battery management system

Over a period of some 5 years Canadian Astronautics Limited (CAL) has developed a system to autonomously manage, and thus prolong the life of, secondary storage batteries. During the development, the system was aimed at the space vehicle application using nickel cadmium batteries, but is expected to be able to enhance the life and performance of any rechargeable electrochemical couple. The system handles the cells of a battery individually and thus avoids the problems of over, and under, drive that inevitably occur in a battery of cells managed by an averaging system. This individual handling also allow cells to be totally bypassed in the event of failure, thus avoiding the losses associated with low capacity, partial short circuit, and the catastrophe of open circuit. The system has an optional capability of managing redundant batteries simultaneously, adding the advantage of on line reconditioning of one battery, while the other maintains the energy storage capability of the overall system. As developed, the system contains a dedicated, redundant, microprocessor, but the capability exists to have this computing capability time shared, or remote, and operating through a data link. As adjuncts to the basic management system CAL has developed high efficiency, polyphase, power regulators for charge and discharge power conditioning.

Moody, M. H.

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY