Search NASA⌕ Search

SEARCH · Search NASA

Results for “DRY HEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

COMBLE-ISLAS water isotopes in precipitation (COMBLEISLASISO)

During the measurement period, precipitation was sampled on daily to sub-daily basis with a sampling kit consiting of a clear plastic box (60x40x40 cm) mounted to a ground structure. Daily sampling lasted from 22 Feb to 24 Mar 2020. At a fixed time of day (10 UTC), samples were collected and the sampling box cleaned for the next sample. Additionally, during intense observations periods (IOPs) announced by ISLAS, ARMS scientists increased sampling frequency to sub-daily sampling. During the campaign period, 2 IOPs were conducted, with in total 12 samples taken. IOP1 lasted from 27 Feb 10 to 02 Mar 2020, and IOP2 lasted from 12 Mar to 14 Mar 2020. Solid precipitation in the box was then melted, transferred to an 8 ml glass vial, sealed and shipped to FARLAB (University of Bergen, Norway) for stable water isotope analysis. Measured stable isotope composition of precipitation samples will be related to conditions at other sampling locations, and at the evaporation site to inform about conservation of water isotope quantities. In the period from 22 Feb to 24 Mar, 23 daily samples were collected at 10 UTC for stable water isotope analysis. During the entire sampling period, a high variability of precipitation phase was encountered. Most samples were recovered in the form of graupel/snow (12 samples), as rain (7 samples), and the remaining samples fell as graupel, snow, rain or frozen rain. Precipitation amounts varied between <1 mm (26 Feb) and 140 mm (25 Feb) within the sampling box. Furthermore, higher-resolution sampling was conducted during 2 intense observation periods (IOPs). During IOP1, lasting from 27 Feb 10 UTC to 02 Mar 10 UTC, 7 samples were collected, all of them as solid phase precipitation. IOP2 lasted from 12 Mar 10 UTC to 14 Mar 09 UTC, and 5 samples (all as graupel/snow) were collected. Samples were processed according to FARLAB standard measurement procedures. In short, samples were transferred to 1.5 ml glass vials with rubber/PTFE septa (part #548-0907, VWR, USA). An autosampler (A0325, Picarro Inc) transferred ca. 2&micro;l per injection into a high-precision vapourizer (A0211, Picarro Inc, USA) heated to 110&deg;C. After blending with dry N2 (< 5 ppm H2O) the gas mixture was directed into the measurement cavity of a Cavity-Ring Down Spectrometer (L2140-i, Picarro Inc) for about 7 min with a typical water concentration of 20 000 ppm. Memory effects were reduced by two times measuring a vapour mixture at a mixing ratio of 50 000 ppm, obtained from 2 injections of 2 &micro;l for 5 min at the beginning of each new sample vial. Thereafter, another 6 injections of 2 &micro;l per sample were measured individually as described above, and averages of the last 5 injections were used for further processing. Three standards were measured at the beginning and end of each batch, including a drift standard DI2 (&delta;D: -50.72&plusmn;0.73 permil, &delta;18O: -7.63&plusmn;0.10 permil), and for calibration the laboratory standards GLW (&delta;D: -307.79&plusmn;0.75 permil, &delta;18O: -40.02&plusmn;0.07 permil) and EVAP2 (&delta;D: 9.52&plusmn;0.65 permil, &delta;18O: 1.81&plusmn;0.13 permil). A detailed calibration report is included with the final uploaded data set.

54 ENVIRONMENTAL SCIENCES↗

CISCC Countermeasures for Spent Fuel Canisters in Concrete Casks

Aging management of spent fuel is an important issue worldwide. Chloride-induced stress corrosion cracking (CISCC) of welded canisters is particularly important for concrete casks, where it occurs in response to a combination of environmental, material, and residual stress factors. In this paper, we introduce a countermeasure to prevent the occurrence of CISCC by adjusting the flow rate of the cooling air into the concrete cask so that the canister surface temperature does not decrease below 100°C, which is a conservative deliquesce temperature threshold for CISCC occurrence. The flow adjustment device was installed in a cask model, and two tests were conducted under the heat rate conditions corresponding to those of an actual canister. In the first test, the device was operated under a condition where the canister surface temperature was below 100°C to verify whether it could increase the canister surface temperature to above 100°C. In the second test, the heat rate was decreased from a state where the canister surface temperature was above 100°C, to verify whether the device could maintain the canister surface temperature above 100°C. Good results were obtained in both cases. However, in the case of a low decay heat rate of spent fuel after extended dry storage, the temperature of the canister surface may decrease below 100°C even if no air supply is provided. Therefore, in this case, it may be necessary to take measures such as blocking air outlets.

Takeda, Hirofumi↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Three influential factors on colloidal nanoparticle deposition for heat conduction enhancement in 3D chip stacks

Thermal management is one of the major challenges facing the development of three-dimensional (3D) chip stacks. Recently, experimental studies have shown that neck-based thermal structure (NTS) between chip layers formed by drying of colloidal suspension in cavity filled with micro-size particles can improve the vertical heat conduction threefold. However, a deep understanding of the mechanisms of neck formation and its influence on heat conduction is still lacking. In this paper, we numerically study the effects of three parameters, i.e., initial nanoparticle concentration, drying temperature and chip surface wettability on neck formation between filler particles and on the resulting heat conduction of the NTS. With increasing nanoparticle concentration, the size and number of necks increase, resulting in an increased effective thermal conductivity (ETC) of NTS. The drying temperature is found to have only little influence on the ETC of resultant NTS, while the neck size and spatial distribution become more uniform at higher drying temperature. When reducing the wettability of the top and bottom surfaces of the cavity, the necks shrink in size until completing evacuating at the top and bottom layers, while the size of the necks between filler particles in the middle height of the cavity expands slowly. In consequence, the ETC of NTS drops at an increasing rate. Being able to reveal the underlying multiple mechanisms of two-phase flow, phase change and heat transport, the current numerical study suggests optimal values for the deposition process, with initial nanoparticle concentration over 0.8%, a drying temperature of 60°C and a uniform contact angle of 30° for practical production of NTS.

3D chip stacks↗

A Novel Steam Condenser with Loop Thermosyphons and Film-Forming Agents for Improved Heat Transfer Efficiency and Durability

In this DOE/NETL BAA program, Advanced Cooling Technologies, Inc. (ACT), with Suez Water Technologies & Solutions (Suez), developed film-forming amine coatings applied to condenser surfaces that incorporated loop thermosyphons to enhance steam surface condenser performance and efficiency for coal-fired power plants. The condensation phenomenon resulting from these coatings promotes efficient dropwise condensation without additional thermal resistance through the use of film-forming amines (FFA). The loop thermosyphon technology was being developed to supplant current pumped cooling water systems to reduce operations and maintenance issues, reduce energy use, and promote high thermal performance. Both of ACT’s advanced coating and loop thermosyphon technologies were developed for application to wet cooling and indirect dry cooling systems. Internal steam condensation and subsequent heat dissipation complete the thermodynamic power cycle used by power plant cooling systems. The successful 3-year project period delved into understanding the experimental performance gain using film-forming amines applied to flat and tubular condenser surfaces under realistic operating conditions. The performance gain was used to create a technoeconomic analysis to more clearly understand the market value for power plants using FFA coatings to achieve dropwise condensation on condenser surfaces. A tall (50 ft.) loop thermosyphon was designed, fabricated, and tested to optimize the performance characteristics by tuning the working fluid charge and determining the temperature drop across the loop at different heat loads. Commercialization opportunities were explored to transition the loop thermosyphon work into the building HVAC market.

20 FOSSIL-FUELED POWER PLANTS↗

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Integrate Power Conversion Unit with MAGNET to Enable Integrated Microreactor Heat Transfer System Testing

Idaho National Laboratory obtained a closed, Brayton-cycle, power conversion unit (PCU) from Sandia National Laboratories. This PCU began as a commercially available, 30 kWe, C30, gas turbine from Capstone. The C30 was modified to use heat from an electric heater in a closed-loop system pressurized with nitrogen or dry air. INL has modified the unit further to integrate it with MAGNET and use heat from a microreactor test article.

42 - ENGINEERING↗

The Melting Behavior of Hydrogen Direct Reduced Iron in Molten Steel and Slag: An Integrated Computational and Experimental Study

Direct reduced iron (DRI) and hot briquetted iron (HBI) are essential feedstocks for tramp element control in the electric arc furnace (EAF). Due to greenhouse gas (GHG) concerns related to CO2 emissions, hydrogen as a substitute for natural gas and a reductant in DRI production is being widely explored to reduce GHG emissions in ironmaking. This study examines the melting behavior of hydrogen DRI (H-DRI) pellets in the EAF containing low-carbon (0.1 wt.%) molten steel and molten slag. A computational heat transfer model was developed to predict the melting behavior of H-DRI pellets. To validate the model, a set of experimental laboratory simulations was conducted by immersing H-DRI in a molten steel bath and slag. The temperature history at the center of the pellet during melting and the shell thickness at different melting stages were utilized to validate the model. The simulation results agree with the experimental measurements of steel balls and H-DRI in different metallic molten steel and slag baths.

Materials Science↗

Thermodynamic Analysis of Thermo-vacuum Clothes Drying Operation

Clothes drying accounts for a significant amount of energy consumed in residential and commercial sectors. A thermal vacuum clothes drying technology (TVCD) is proposed as an advanced clothes dryer which can significantly reduce the energy requirements by expediting the drying process. In the conventional convective clothes dryer, hot dry air is introduced into the drum which gets in direct contact to dry the clothes. This process is energy inefficient since the significant amount of heat and the water carried out with the exhaust stream are wasted. In contrast to the conventional convective drying technique, the drying mechanism of TVCD is through nucleate boiling at low temperature due to reduced vessel pressure. The process is not only efficient but also reduces the required time for drying. The objective of this paper is to develop a comprehensive thermodynamic model to predict the transient drying process of TVCD. The three-stage system model including the detail analysis of individual components is capable of simulating the variation of the water content in the textile under various operational conditions. The preliminary results show that the drying time of 3 lb textile from 70% to 2.5% in TVCD is approximately four times less than the time required in the conventional clothes dryer. Parametric studies are carried out to understand the effect of operation conditions and component geometry on the system performance. Energy consumption of the system is also analyzed.

Yang, Cheng-Min↗

Powdermet CRADA for VELOCITI Voucher (CRADA Final Report)

NLR shall develop a model of an electric thermal energy storage (ETES) system in the System Advisor Model (SAM) framework that uses a salt and particle slurry developed by PowderMet as the thermal energy storage medium. The ETES shall consist of a recuperated sCO 2 Brayton cycle using 2-tank indirect thermal energy storage and an electric heater for heat input. The salt slurry uses chloride salt and operates at a maximum temperature of 500-720°C. The ETES uses dry air cooling. The salt slurry will be modeled as a sensible heat storage medium and as a latent heat storage medium. NLR will use the model to do parametric analysis of the factors affecting the performance (ex., round trip efficiency) of the ETES system. NLR will work with PowderMet to estimate the costs of system components and total system costs, with the levelized cost of electricity (LCOE) as the primary cost metric.

14 SOLAR ENERGY↗

Engineering metal-oxide interface by depositing ZrO 2 overcoating on Ni/Al 2 O 3 for dry reforming of methane

Zirconium oxide (ZrO 2 ) was deposited onto Ni/Al 2 O 3 catalyst as overcoating by atomic layer deposition (ALD) for dry reforming of methane (DRM). High-temperature heating during H-2-reduction could transform the ALD-prepared ZrO 2 thin film to tetragonal phase and crack the encapsulating layer on Ni sites, which constructed a beneficial Ni-ZrO x interface. Here, interfacial surface oxygen vacancies on ZrO 2 overcoating were induced by the partial reduction of ZrO 2 surface during high-temperature H 2 reduction, with the assistance of Ni. During DRM, the interfacial oxygen vacancies enhanced CO 2 activation by dissociating CO 2 and releasing active O, thereby limiting carbon formation. For DRM at 700 °C and 800 °C, Ni/Al 2 O 3 with 5 cycles of ZrO 2 ALD overcoating enhanced both activity and stability significantly. For a 100-h DRM test at 600 °C, no deactivation was observed for the Ni/Al 2 O 3 catalyst with 10 cycles of ZrO 2 ALD overcoating, as compared to 59% relative activity loss of Ni/Al 2 O 3 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Universal correlation for falling film evaporation on a horizontal plain tube

Falling film evaporators are widely used in many industrial sectors, such as desalination, refrigeration & air-conditioning, and chemical processes. The heat transfer correlations suitable for wider operating conditions and various refrigerants are useful for designing falling film evaporators. Although many researchers developed the correlation for their own experimental data, there is a limited universal correlation for falling film evaporators. In addition, the dry-out effects were not considered in the available universal correlations. Here, therefore, this study proposes a new correlation for falling film evaporation on a single horizontal plain tube, which includes nucleate boiling, film evaporation, and dry-out effects. The proposed correlation covers a wider range of operating conditions (Heat flux is of 2.5–168kWm -2 , and film Reynolds number is up to 3500), various refrigerants (R134a, R245fa, R1234ze(E), R123, R32, R410A, R290, and R600a), and the large number of experimental data (1101 data in total). The proposed correlation is validated against the available standard correlation with regard to mean absolute deviation (MAD) and R 2 values. The MAD of the new correlation is about 10%, respectively, which is the lowest among other correlations. Similarly, the R 2 showed a value of 0.92, which is the highest compared to the existing correlations. A simplified correlation is also proposed.

42 ENGINEERING↗

Global scale assessment of urban precipitation anomalies

Urbanization has accelerated dramatically across the world over the past decades. Urban influence on surface temperatures is now being considered as a correction term in climatological datasets. Although prior research has investigated urban influences on precipitation for specific cities or selected thunderstorm cases, a comprehensive examination of urban precipitation anomalies on a global scale remains limited. This research is a global analysis of urban precipitation anomalies for over one thousand cities worldwide. We find that more than 60% of the global cities and their downwind regions are receiving more precipitation than the surrounding rural areas. Moreover, the magnitude of these urban wet islands has nearly doubled in the past 20 y. Urban precipitation anomalies exhibit variations across different continents and climates, with cities in Africa, for example, exhibiting the largest urban annual and extreme precipitation anomalies. Cities are more prone to substantial urban precipitation anomalies under warm and humid climates compared to cold and dry climates. Cities with larger populations, pronounced urban heat island effects, and higher aerosol loads also show noticeable precipitation enhancements. This research maps global urban rainfall hotspots, establishing a foundation for the consideration of urban rainfall corrections in climatology datasets. This advancement holds promise for projecting extreme precipitation and fostering the development of more resilient cities in the future.

Science & Technology - Other Topics↗

Development of Mockups and Instrumentation for Spent Fuel Drying Tests

The purpose of this report is to provide updates on the experimental components, methodology, and instrumentation under development for use in advanced studies of realistic drying operations conducted on surrogate spent nuclear fuel. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. Water remaining in canisters upon completion of drying procedures can lead to cladding corrosion, embrittlement, and breaching, as well as fuel degradation. Additional information is needed on the drying process efficacy to help evaluate the potential impacts of water retention on extended longterm dry storage. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates additional, well-designed investigations. Smaller-scale tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report describes the implementation of moisture monitoring equipment on a pressurized, submersible system employing a single waterproof, electrically heated spent fuel rod simulator as a demonstration of analytical capabilities during a drying process. A mass spectrometer with specially designed inlets was used to monitor moisture and other gases at 150 kPa to 800 kPa for a test simulating a forced helium dehydration procedure and below 1 torr for tests mimicking a vacuum drying process. The dew point data from the mass spectrometer was found to be in good agreement with a solid-state moisture probe. A distinct advantage of the mass spectrometer system was the capability to directly sample from the hightemperature (>200 °C) head space expected in a prototypic scale experiment where a solid-state moisture probe would suffer considerable loss of accuracy or fail altogether. The operational and analytical experiences gained from this test series are poised to support an expansion to assembly-scale tests at prototypic length. These assemblies are designed to feature prototypic assembly hardware, advanced diagnostics for in situ internal rod pressure monitoring, and failed fuel rod simulators with engineered cladding defects to challenge the drying system with waterlogged fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Planar-Cavity Receiver Reactor for Solar Thermochemical Dry-Reforming

Concentrating solar thermal (CST) systems can be leveraged to provide not only heat for power generation, but also for energy storage and thermochemical fuel production. Such solar thermochemical processes have been studied conceptually, from solar thermochemical hydrogen production (STCH) and thermochemical energy storage (TCES), to gasification, reforming, and fuel upgrading by various means. The solar receiver and reactor are critical components in the conversion of solar energy into chemical energy in the form of 'solar fuels'. For effective conversion of solar energy within a coupled solar receiver-reactor, extremely high temperatures are required, thereby demanding a high solar concentration ratio (CR) for efficient operation. This creates a design challenge for the receiver-reactor, as many thermochemical processes involve gas or gas-solid systems that are limited by low heat transfer coefficients. A unique receiver design is proposed that has the potential to incorporate various high-temperature thermochemical processes such as TCES-assisted power generation, methane reforming, or STCH processes. Modeling this receiver and its potential applications requires a full three-dimensional model that accurately captures the interconnected effects of receiver geometry, spatial solar irradiance, complex radiation, reaction kinetics, fluid dynamics, and heat transfer. In this paper we analyze a CST system integrated with this unique planar-cavity receiver-reactor design using the developed model. The model presented in this paper showed where improved thermal management was needed to achieve suitable receiver performance when a dry-methane reforming process is implemented.

14 SOLAR ENERGY↗

Dry and warm conditions in Australia exacerbated by aerosol reduction in China

A substantial decline in anthropogenic aerosols in China has been observed since the initiation of clean air actions in 2013. This study reveals a linkage between aerosol reductions in China and drier and warmer conditions in Australia. Aerosol decline in China trigger alterations in temperature and pressure gradients between the two hemispheres, leading to intensified outflow from Asia towards the South Indian Ocean, strengthening the Southern Indian Subtropical High and its related Southern Trade Winds. Consequently, this atmospheric pattern results in a moisture divergence over Australia. The reduction in surface moisture further results in more surface energy being converted into sensible heat instead of evaporating as latent heat, warming the near-surface air. The intensified dry and warm climate conditions further cause the increase in wildfire risks during fire seasons in Australia. Our study illuminates the potential impact of distant aerosols on precipitation and temperature variations in Australia, offering valuable insights for drought and wildfire risk mitigation in Australia.

aerosol-cloud interaction↗

Coupled chemical–CFD modeling of unsealed dry storage of advanced test reactor spent fuel

We report given the current lack of long-term disposal for spent nuclear fuel storage in the United States, the current inventory of advanced test reactor (ATR) fuel at Idaho National Laboratory (INL) is expected to be stored in a dry storage facility for an extended storage period. As part of an effort to understand the conditions during a 50-year period, a three-dimensional computational fluid dynamics (CFD) of the unsealed canisters packed with spent fuel in the storage facility was constructed, this CFD model is coupled with radiolytic chemical reactions associated with water vapor and other species. The coupled model is simulated over a range of sensitivity parameters for the fuel decay heat, relative humidity, and oxyhydroxide film thickness for undried and fully-dried fuel. The most important parameter was the initial fuel decay heat. Over the range of cases, the hydrogen and nitric acid concentrations are low enough no significant impact is expected.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fewer Troughs, Not More Ridges, Have Led to a Drying Trend in the Western United States

High-amplitude ridges can enforce heat-trapping systems that persist through an entire season, contributing to drought events. However, the impacts of day-to-day weather system changes at the meso- and synoptic-scale are also important, albeit less well studied. Here, we identify five weather types (WTs) from 500-hPa geopotential height anomalies. These categories include WT4, which represents ridges and associated dry and warm anomalies, and WT3, which characterizes troughs and associated wetter- and colder-than-normal conditions and is the largest contributor to precipitation in the western U.S. While no discernable trend is evident for WT4 conditions, WT3 conditions have undergone a distinctive decrease in frequency at both annual and seasonal scales, thus a general drying trend across the west during this time period may be more significantly associated with fewer troughs rather than more ridges. Attribution analysis reveals that this decrease in wetter and colder weather is a likely result of anthropogenic forcing.

54 ENVIRONMENTAL SCIENCES↗